Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.5 L+₹1.3 L (4.24%)Rejected-AOC | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹31.9 L+₹1.7 L (5.52%)Rejected-AOC | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹32.1 L+₹1.8 L (6.02%)Rejected-AOC | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹32.5 L+₹2.2 L (7.41%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
31 Aug 2022, 6:00 pmClosed
GARRISON ENGINEER BRICHGUNJ PORT BLAIR
GARRISON ENGINEER BRICHGUNJ PORT BLAIR-744103
PROVN OF LBW WORKS AND SPECIAL REPAIR WORKS UNDER AGE BR II AT BRICHGUNJ MIL STN PORT BLAIR
2022_MES_544903_1
8253A
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER BRICHGUNJ PORT BLAIR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER BRICHGUNJ PORT BLAIR
₹62,000
Yes
21 Sept 2022
12 Aug 2022
2 Sept 2022
12 Aug 2022
31 Aug 2022
26 Aug 2022
12 Aug 2022 - 26 Aug 2022
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil all as specified.
Returning filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick with excavated soil all as specified
Removal of excavated material to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 M above the starting point.
M&L cement concrete (1:3:6) C-2 40mm graded aggregate as in foundation filling in and for mass concrete all as directed
Demolition of precast concrete block walling, built in cement mortar including all quoins, arches, pillars, etc
M&L for precast cement concrete solid block masonry with solid blocks using PCC 1:3:6, type Cl (using 20mm graded stone aggregate), exc. 10cm in width, set in CM 1:6 complete all as specified
S&F MS steel work in tubular, trusses including purlins, special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade 240 all as specified.
S&F MS works as in wind ties for roof including securing bolts etc complete all as specified.
M&L for plates of plain or chequered, square cut or notched of steel welded to steel structure for base plate etc.complete all as specified
M&L for prepainted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified.
M&L for prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified.
Applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces over 10cm width or girth all as specified.
M&L rendering 10 mm thick on fair faces of concrete/block masonry surfaces in cement mortar 1:6 and finished even and smooth without using extra cement all as specified.
M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer including putty with smooth finish on walls all as specified.
M&L for two coats of weather coat (Exterior) all guard emulsion, any colour/tined to new wall surfaces over a coat of primer including necessary preparation of wall surfaces all as specified and directed.
M&L for hard core of guage n.exc.63mm using broken stone aggregate spread, levelled, watered and rammed to a true surface all as specified.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-1 ( using 20 mm graded crushed stone aggregate ) as in plinth protction etc complete all as specified and as directed.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc 400 Sqm incl removing upto and distance n.exc. 50m complete all as specified and as directed'
Rough excavation not exceeding 1.5 metre deep and getting out, in any type of soil all as specified.
M&L for 100mm thick plain cement concrete 1:3:6 type C-2 ( using 40 mm graded stone aggregate ) as in floor finished even and fair, to receive floor finish complete all as specified and as directed'
Material and labour for Machine pressed precast concrete interlocking paver block with grey cement and no pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, over and including 50mm consolidated thick sand cushioning including watering and consolidation for base/ bed all as specified a complete all as specified and as directed
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings.
M & L for water proofing treatment with the following specifications including taking down existing roof treatment including cement screed/plaster of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and as per manufacturers instructions:- (i) Rendering 10mm thick in CM 1:4 on fair faces of brick or concrete wall surfaces finished smooth and even mixed with water proofing compound @ 3% by weight of cement or as per manufacturers instructions complete all as specified and as directed by Engineer - in -Charge. (Note:- Water proofing compound shall be measured and paid separately) (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying Aquashield membrane weighing 3to 4Kg/sqm, with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iii) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane.
S&F as in repairs aluminium anodised snap grid frame work (size of grid 605x605mm) with 35x25x1.5mm main tee and 25x25x1.4mm, cross tee and wall angle for false ceiling and suspended with 6mm dia GI wire, hooked to roof with needful adjustement up to 1200mm long by means of ceiling cleats made out of GI Flat 40 X 3mm 60mm long and expansion holdfasteners 12.5mm dia 40mm long, including dismantling celing board of any description and any type fixed to the aluminium frame work with screws or nails etc complete all as specified and as directed by Engineer -in-Charge.
Fixing only in repairs Eco board 600 X 600 X 4mm thick decorative type fixed to the aluminium frame work with screws or nails etc including two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engineer -in-Charge. Note :- Eco Boards obtained from item No.5 to be re-used
S&F Eco board 600 X 600 X 4mm thick decorative type fixed to the aluminium frame work with screws or nails etc including two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engineer -in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
S & F coloured joint free non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match over and including screed bed in cement mortar 1:4, 15 mm thick, all as specified and directed.
S & F coloured glazed ceramic tiles 300mm x 200mm x 5.5mm to 6mm thick on vertical surfaces such as skirting & dados etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces etc including backing coat of 10mm thick CM 1:3 all as specified and directed.
M & L for machine cut kota stone slab 20 to 25mm thick in treads of steps in stair laid and jointed with white cement slurry mixed with pigments to match the shade of the slab including rubbing and to get mirror polishing laid over and including 20mm thick cement screed bed in cement mortar 1:4, complete all as directed
M & L for machine cut kota stone slab 20 to 25mm thick in rise/steps, skirting, dado and pillar laid and jointed with white cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing overand including 10mm thick rendering cement t mortar 1:3, complete all as directed
M & L for granite slab 20 mm thick as in cooking platforms, bedded 15mm thick ,in cement mortor 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and as directed by Engineer-in-charge
Material & labour for designer coloured chequred cement concrete tiles of size 20cm x 20cm x 25mm with jointed and pointed in neat cement slurry with grey cement and pigment to match the shade over and including screed bed 20mm in CM (1:4) all as specified and directed.
Taking down cement plaster of any description from wall/ceiling including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement.
M&L rendering 5mm thick in CM 1:4 with using water proofing compound over 10mm thick in CM 1:6 on external surfaces of block masontry even and smooth eithout using extra cement.(WPC shall be added in only 5mm thick top layer of plaster @ 2% of cement content) (Note:- WPC shall ne measured and paid seperately.)
Supply only integral water proofing compound.
M&L for rendering 5 mm thick in CM 1:3 finished even and smooth without using extra cement on ceiling including cement slurry 3 kg/sqm all as specified and directed.
M & L for two coats of OBD over a coat of primer on newly plastered surfaces of walls including nesessary preparation of surfaces all as specified and directed.
M & L for two coats of OBD over a coat of primer on newly plastered surfaces of ceiling including nesessary preparation of surfaces all as specified and directed.
M & L for preparing old decorated surfaces of ceiling and applying two coats of OBD over a coat of primer all as specified and directed.
M & L for two coats of OBD over a coat of primer on old plastered surfaces of walls including nesessary preparation of surfaces all as specified and directed.
M&L for two coats of weather coat (Exterior) all guard emulsion, any colour/tined over a coat of primer.including complete removal of old treated wall surfaces complete all as specified and as directed by Engineer -in-Charge.
M&L for preparation of old steel surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Taking down chowkats or frames with shutters area n.exc 1.5 Sqm each(without taking off shutters from the frame) all as specified and as directed
All as per Item No.46 above but are exc 1.5 Sqm but n.exc 4.00 Sqm
S & F Aluminium anodised (minimum anodisation is 15 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangement etc, complete with standard aluminium sections, all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply only 12 mm thick Prelaminatd particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed to aluminium frames complete all as specified and as directed by Engineer -in-Charge.
Supply only 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
Supply only 4mm thick figured glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
Supply only aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of apeture 1.4mm fixed with aluminium wire staples etc.complete all as specified and as directed by Engineer-in-charge.
S&F solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing in SSR complete all as specified and directed by Engineer -in-Charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC `C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing in SSR complete all as specified and directed by Engineer -in-Charge.
S&F in repairs 75mm Size Butt hinges type C-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and as directed by Engineer-in-charge.
S&F in repairs 100mm Size Butt hinges type B-21 , extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and as directed by Engineer-in-charge.
S & F in repairs 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-charge.
S & F in repairs 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-charge.
S & F in repairs 100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-charge.
S&F in repairs Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S & F in repairs 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in-charge.
S & F in repairs100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in repairs 140mm long door stopper of aluminium alloy body and tounge, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed by Engineer -in-Charge.
Taking up or down 20mm dia bore steel tubing galvanised and connections complete all as specified and directed.
Taking up or down 15mm dia bore steel tubing galvanised and connections complete all as specified and directed.
Supply and laying 20mm external dia UPVC pipes SDR11 including Plain UPVC fittings SDR11 mean fittings which do not have any metal component and is jointed with CPVC solvent cement only (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End plugs, etc) & Special fittings include CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, etc), Unions, Ball valves, Flange and tank adaptor as on walls/ceiling/floors complete all as specified and as directed by Engineer-in-charge.
Supply and laying 25mm external dia UPVC pipes SDR11 including Plain UPVC fittings SDR11 mean fittings which do not have any metal component and is jointed with CPVC solvent cement only (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End plugs, etc) & Special fittings include CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor, etc), Unions, Ball valves, Flange and tank adaptor as on walls/ceiling/floors complete all as specified and as directed by Engineer-in-charge.
S&F in repair 20mm dia Gun metal globe or gate valve with iron wheel head, screwed both end for iron pipe complete all as specified and as directed by Engineer-in-charge.
S&F for 25mm dia ball brass valves, high pressure, with polythen float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed by Engineer-in-charge.
S & F PVC flushing cistern 10 litres capacity syphonic action type, low level, white with inlet, ball valve, float, handle and flush pipe, etc complete all as specified and directed.
S&F in repairs Brass Chromium plated shower rose 125mm size, with swivel joint, fixing to steel pipe or union, complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs Bib tap cast copper alloy chromium plated, 15 mm dia with crutch or butter-fly handle, screwed down, screwed for iron pipe or for brass ferrule etc all as specified and directed.
S & F in repairs angular stop cock, cast copper alloy chromium plated, 15 mm dia screwed down high pressure, screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-Charge.
All as per Serial Item No 73 above but fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs fancy type, Pillar taps , cast copper alloy , with capstan heads , chromium plated , screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm and fixed in repairs, all as specified.
S & F in repairs sink with drainage board, made up of stainless steel, 1mm thick for kitchen or laboratory with plug washers and waste fittings, including bedding in cement mortar 1:3 into dwarf wall or cantilever brackets and connecting union to pipe, over all size 915mm x 460mm, bowl size 410 x 330 x 160mm etc, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair vitreous china wash hand basin white flat back size 630x450mm incl brackets, PTMT coupling, 32 mm GI pipe waste pipe complete all as specified.
S&F in repairs brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in repairs stainless steel gratings 125mm dia, complete all as specified and as directed by Engineer-in-Charge
S&F PVC connection both end brass union 15 mm dia & check nuts of length 450 mm long.
S & F in repairs vitreous china squatting pan, Orissa pattern size 630X450 mm white with integral foot rest (excluding flushing cistern) including 'P' or 'S' trap etc complete all as directed.
Disconnecting of existing tank of capacity 500 ltr and setting aside or lowering if required for repairs cleaning etc and refixing in position hoisting and connecting , complete all as specified and as directed by Engineer -in-Charge.
S & F rotational moulded polythelene water storage tanks Triple Layers ISI marked (cylindrical vertical with closed top) of 500 Ltrs capacity with tank cover (top), hoisted and fixed in position, including taking down existing with all connections complete all as specified and as directed by Engineer -in-Charge.
Dismantling of CI drain pipes,50-100 mm dia jointed in cement mortar including all fittings joints etc complete all as specified and directed.
M&L for PVC (SWR) pipes 110mm bore double socketed in any length with rubber ring joints, fixed to wall incl testing of pipe etc complete all as specified and directed by Engr-in-Charge
M&L for PVC (SWR) pipes 75mm bore double socketed in any length with rubber ring joints, fixed to wall incl testing of pipe etc complete all as specified and directed by Engr-in-Charge
M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm outer dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed.
Supply and fix PVC (SWR) bends 110mm bore with oval access doors all as specified and directed.
Supply and fix PVC (SWR) bends 75mm bore with oval access doors all as specified and directed.
Supply and fix PVC (SWR) junction single, (Single T) 110mm bore, equal or unequal with oval access doors all as specified and directed.
Supply and fix PVC (SWR) junction single, (Single T) 75mm bore, equal or unequal with oval access doors all as specified and directed.
Supply and fix PVC (SWR) branch piece, single (single Y) equal or unequal 110mm bore, equal or unequal with oval access doors all as specified and directed.
Supply and fix PVC (SWR) branch piece, single (single Y) equal or unequal 75 mm bore, equal or unequal with oval access doors all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) all as specified and directed.
M&L for PCC 1:3:6, type C2, (Using 40 mm graded stone aggregate), 100mm thick as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed.
M&L for removing loose and broken concrete by chiselling /picking etc upto a depth of 10 to 20 mm from floor/roof slab/chajjas and similar structural members cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles including necessary scaffolding etc and removal of debris to a distance not exceeding 50m, complete all as specified and as directed by Engineer -in-Charge.
M&L for application of high build polymer modified cement mortar (1:2.5) mixed with 3 kg SBR per bag of cement in ceiling surfaces 10 to 20mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR (1 Ltr SBR + 1 Ltr) water + 3 kg cement), complete all as specified and as directed by Engineer -in-Charge.
Materials and labour for removing loose and broken concrete by chiselling /picking etc upto a depth of 50 to 100 mm from columns, beams and similar structural members cutting edges cleaning the dismantled portion with wire brushes etc to remove dust, dirt and other foreig
Materials and labour for applying one coat of anti corrossive primer @ 0.25 Lit/Sqm for the steel area to exposed old and new reinforcement to the full circumfrance and length of bars to form unbroken 40 Micron thick film all as specified and directed by Engr-in-Charge.
Materials and labour for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufactures instruction to old concrete surfaces all as specified and directed by Engr-in-Charge to surfaces of columns, beams and similar structural members all as specified
Use and waste off fair finished flat Form work to RCC columns, posts and similar items including edges all as specified and directed by Engr-in-Charge.
Materials and labour for non shrink, cementitous micro concrete mixed with 12.5 graded stone aggregate using Renderoc RG or equivalent as approved by GE (18 Kg Aggregate : 25 Kg Renderoc RG) respectively (as per manufatures instruction) laid in average thickness 50 to 100 mm in situ completee all as specified and directed
Materials and labour for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified. Make : Concure WB white of Fosroc or equivalent as approved by GE.
Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engineer -in-Charge.
Use and waste of Form work to flat surfaces of RCC fins, fascia ,chjjas and similar items including edges, for fair finished surfaces complete all as specified and as directed by Engineer -in-Charge.
M & L for RCC M-30 (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts,complete all as specified and as directed by Engineer -in-Charge.
M & L for RCC M-30 (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer -in-Charge.
Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M & L For Point wiring complete with proper colour coading using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked and including PVC conduit with ISI marked with all accessories in wall/celling/floor/roof etc, sunk pressed steel not less than 2 mm thick, 50 mm deep terminal boxes with 3mm thick ISI marked plastic laminated sheet top cover fastended with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts Multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
One light Point controlled by one switch.
Supply and fix Switch piano, flush button, single pole, ISI marked, one way 5 Amps 240 volts .complete all as specified and as dircted by Engineer-in-Charge
Supply and fix switch socket outlet 3 & 2 pin (mult pin) 5 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed by Engineer-in-Charge
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed Engineer-in-Charge
Supply and fix energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
Supply and fix in repair metal enclosure distribution board SPN, 4 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, complete all as as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, all as specified and as directed.
Supply and fix MCB SPN 240 volts, 5 to 32 Amps, all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
M & L for point wiring complete with single core multi stranded Copper conductor FRLS cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit suitable size including Tee junction bends etc concealed in wall/fixed on ceiling and PVC switch board hylam sheet of 3mm thick including M.S. sunken boards of suitable size for housing switched sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuty. including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in brick wall. complete all as specified and as directed by Engineer-in-Charge
One light point/Exhaust fan point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No.118 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuty conductor, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge Make:-Anchor/Havells/Bajaj
Supply and fix bell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge.
Taking down and refixing ceiling fan and connecting up including provision of cable from ceililng rose or connector to fan complete all as specified and as directed.
Taking down and refixing old serviceable exhaust fan and connecting up including provinding of cable from ceiling rose/connector to fan complete all as specified and as directed.
Supply and fix Recess mounted LED Ultra slim 15 w Round type with in die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge
S&F 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Supply & fix in repair LED holder type non dimmable bulb 10 watt complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal enclosures Loadline distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB as incomming complete all as specified and as directed including taking down old MCB DBs complete.
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed.
M & L for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated insheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6.0 sqmmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty UG cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 3.5 Core 25 sq mm
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 Core 10 sq mm.
Supply and lay cable protection pipe of HDPE double wall corrugated (DWC) including couplers,bends etc of size 50mm OD and ID 38 mm confirming to IS 14930 -II and ISI Marked all specifed and directed
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including sperading and punning down including watering consolidation complete all as specified and directed.
Supplying and laying unreinforced precast cement concrete cable cover Class LV, Type I, flat, size 250mm x 150mmx40mm in trenches for cable protection embossed with Electric on the top surface complete all as specified and directed
USR Transport
P Babu
Bismi Builders & Enterprises
ANITA VARMA ENTERPRISES
M/s Kamal Electrical
M/s Saina Enterprises
DEEPAK AGENCIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .