Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹96.8 L+₹7.0 L (7.78%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance other than L1 | |
| 3 | L3₹96.8 L+₹7.1 L (7.86%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance other than L1 | |
| 4 | L4₹1.0 Cr+₹14.2 L (15.8%)Rejected-Finance 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L4 | Rejected-Finance other than L1 | |
| 5 | L5₹1.1 Cr+₹16.3 L (18.1%)Rejected-Finance H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L5 | Rejected-Finance other than L1 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
12 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NEW DELHI
HQ CWE NEW DELHI
ADDN ALTN AND SPL REPAIR OF BLDG No P137 AND P138 02 BLOCKS 24 QTRS OF OR MD ACCN AT 180 OR MAHIPALPUR UNDER GE SOUTH DELHI CANTT10
2024_MES_668988_1
CWE/ND-26/2024-25
Open Tender
Civil Works
Item Rate
180 days
NEW DELHI
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
GE South Delhi Cantt
₹2.0 L
Yes
28 Nov 2024
31 Aug 2024
14 Oct 2024
31 Aug 2024
12 Oct 2024
28 Sept 2024
Amount
Cutting of vegetable plant (girth not exceeding 300mm) from roof, terrace, chajjas etc digging out the roots and making good the surface in PCC 1:2:4 type B1 with surfaces finished to match complete including scaffolding etc, complete all as specified and directed by engineer-in-charge.
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar, complete all as specified and directed by engineer-in-charge.
Demolition of mud in roof, any thickness, including plastering and leeping upto two storey bldg including necessary scaffolding arrangement complete (whether full thickness removed or only a part there of) and removing rubbish from cantonment area or as directed, complete all as specified and directed by engineer-in-charge.
M&L for cutting out craks to V-section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete all as specified and directed by engineer-in-charge.
M&L for roof treatment in following stages, complete all as specified and directed by engineer-in-charge. (i) Preparation of concrete surfaces by wire brush and cleaned top surfaces of cement concrete . (ii) PCC type B-0, 1:2:4 (12.5mm gradded aggregate) to maintain slop with average thick of 40mm as in roof. (iii) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 Kg per sqm including cleaning surfaces (iv) APP polymeric water proofing membrane minimum 3 mm thick and wieghing not less than 3.0 Kg per Sqm , black finish reinforced with non woven polyester matt with a thermo fasable finish laid over bitumen primer @ 0.5Kg/Sqm by torching application with a propane or a butrane gas torch with an overlap of 100mm at the sides and 150mm at the ends, as per manufacturers instructiions incl preparation of surface (Manufacturer as approved by GE).
Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed by engineer-in-charge. Makes- JOHNSON, ROCOTILES, THERMATECK
M&L for cement concrete type B1 - 1:2:4 (using 20mm graded stone aggregate) in roof kerbs or mud stop rounded or chamfered on edge etc., complete all as specified and directed by engineer-in-charge.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required, complete all as specified and directed by engineer-in-charge.
S&F 110 mm dia Cast iron pipes Type 'B', single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and directed by engineer-in-charge.
S&F 75 mm dia Cast iron pipes Type 'B', single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and directed by engineer-in-charge.
S&F 75mm Cast iron bends type ‘B’ (any radius), complete all as specified and directed by engineer-in-charge.
S&F 100mm Cast iron bends type ‘B’ (any radius), complete all as specified and directed by engineer-in-charge.
S&F for 75mm cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and directed by engineer-in-charge.
M&L in repair for 75mm Cast iron Nahani trap/floor trap with grating including jointing of waste pipe and fixed in cement concrete type B-1, 1:2:4, complete all as specified and directed by engineer-in-charge.
S&F in repairs 125mm x 100mm salt glazed stone ware gully traps square & round mouthered trap 'P' including case iron grating and fixed, including necessary excavation and earthwork, concrete in bed, surrounds, kerbs etc., and jointing to drains in CM 1:1, complete all as specified and directed by engineer-in-charge.
Taking down rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories, complete all as specified and directed by engineer-in-charge.
S&F 110 mm UPVC pipes Type 'A', single socketed, in any length with rubber ring joints, laid in trenches or in floor or fixed to walls, complete all as specified and directed by engineer-in-charge.
S&F 110mm UPVC (SWR) Bends/Tee type ‘A’ (any radius), complete all as specified and directed by engineer-in-charge.
S&F holder bat clamps 100mm bore out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed by engineer-in-charge.
Demolition of reinforced cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed by engineer-in-charge.
M&L for RCC M-25 using 20mm graded aggregate slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M&L for RCC M-25 using 20mm graded aggregate as in columns and parapet wall , pillars, piers, posts and struts, etc complete all as specified.
Formwork, rough finished conc surfaces to slabs, sides of parapet wall and soffits of floor or roof beams, haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M & L for 10mm dia & over, mild steel TMT bars, cut to length, bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, quality of steel conforming to deformed or twisted bars Fe-410-W (Gde-E-250)
All as per item no 25 above, but 5mm dia and over up to and incl 10mm dia as in stirrups
M&L for chipping of spelled and loose concrete and cleaning rust from reinforcement by sand blasting, scrubbing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as anti rust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adhesive on complete exposed surfaces of concrete and provide gunniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :2 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by weight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs, chajjas, fins, facias, parapets, columns and beams etc complete including necessary scaffolding , shuttering necessary chased to brick work or RCC members at any height upto full height of buildings including removing of small trees shrubs etc complete all as specified and directed. (Note: Steel mesh to be welded with the existing reinforcement. The cost of welded mesh is deemed to be included in the unit rate quoted.)
Taking down cement or cement lime plaster, any description, on brick or stone walls, concrete surface etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by engineer-in-charge.
M&L rendeing 15 mm thick on stone masonary surface other then fair faces surfaces in CM 1:4 finished even and smooth without using extra cement including necessary scaffolding, formwork, safety precautions for multi storey bldgs, complete all as specified & directed.
M&L rendeing 10mm thick on stone masonary surface other then fair faces surfaces in CM 1:6 finished even and smooth without using extra cement including necessary scaffolding, formwork, safety precautions for multi storey bldgs, complete all as specified & directed.
M&L rendeing 5mm thick on ceiling surfaces in CM 1:3 finished even and smooth without using extra cementincluding necessary scaffolding, formwork, safety precautions for multi storey bldgs, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of wall and applying 3 mm thick wall care putty on whole surfaces to achieve smooth, even and uniform surface including grinding with sand paper and levelling of surface and applying two coat of oil bound distemper over a coat of primer of same manufacturer on white or tinted over existing prepared putty base surface, complete all as specified and directed by engineer-in-charge. Note :- (a) All work shall be done mechanically through authorised applicator only (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 Days from start date of the said finishing work. (c) The contractor shall provide application testing and certification of finishes by paint manufacturing firm/their authorised applicator. (d) Cost of all above aspects shall be deemed to be included in quoted rate of the contractor.
M&L for preparation of newly plasered surfaces of walls and applying two coat of super quality weather proof exterior emulsion paint over and including one coat of primer from the same manufacturer on external wall / ceiling surfaces including a coat of 3mm thick wall care putty to achieve smooth surface, complete all as specified and directed by engineer-in-charge. Note :- (a) All work shall be done mechanically through authorised applicator only (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 Days from start date of the said finishing work. (c) The contractor shall provide application testing and certification of finishes by paint manufacturing firm/their authorised applicator. (d) Cost of all above aspects shall be deemed to be included in quoted rate of the contractor.
M&L for preparation of newly plasered surfaces of ceiling and applying three coat of white wash, complete all as specified and directed by engineer-in-charge.
M&L for complete removal of existing treatment from internal surfaces of wall by electrically operated grinder, washing and filling of holes with filler material and applying 3 mm thick wall care putty in two layers on whole wall surface including grinding with sand paper and levelling the surface and than applying two coat of oil bound distemper over a coat of primer of same manufacturer on white or tinted surface over existing prepared putty based surface, complete all as specified and directed by engineer-in-charge. Note :- (a) All work shall be done mechanically through authorised applicator only (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 Days from start date of the said finishing work. (c) The contractor shall provide application testing and certification of finishes by paint manufacturing firm/their authorised applicator. (d) Cost of all above aspects shall be deemed to be included in quoted rate of the contractor.
M&L for preparation of old surfaces of wall and applying two coats of white wash, complete all as specified and directed by engineer-in-charge.
M&L for preparation of old surface of ceiling and applying one coats of white wash, complete all as specified and directed by engineer-in-charge.
M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cms width or girth and apply two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed by engineer-in-charge.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cms width or girth and apply one coat of synthetic enamel paint, complete all as specified and directed by engineer-in-charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cms width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by engineer-in-charge.
M&L for preparation of old steel surfaces of any description not otherwise described over 10 cms width or girth and apply one coat of synthetic enamel paint, complete all as specified and directed by engineer-in-charge.
M&L for expose the first joint of masonry structure at ground level horizontally. The plaster must be knocked off at least 50 cm beyond the visibly penetrated area. Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. Drilling Holes: Drilling holes 10mm diameter in masonary structure along the side of the joint at 45° angle so as to cross the brick/block at the intervals spacing if 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge. Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Install Packer injection packers 9.8mm diameter, 10cm long in the holes and tighten. Fix the packer securely using Sikadur 31. Note: Cutting of Packers: Cut the packers after completion of grouting without damaging structural elements.
M&L for injecting of a 3 part, very low viscous, elastic polyacrylic injection resin Injection 306 with a versatile and adjustable reaction time having Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperatrure and execution requirement between 8-50 mins, pH – 9-10, Tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. The holes should be drilled until a depth of approx 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump Injection-306 at >20 bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas. If voids in masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout. When movement stops or Injection-306 appears at the next packer move to the next packer and inject. If the dampness is heavy, inject similarly at next joint line, complete all as specified & directed.
M&L for providing and injecting chemical chlorpyrifos emulsifiable for post constructional anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes, complete all as specified and directed by engineer-in-charge.
M&L for anti termite treatment of soil under existing floors using chemical chlorpyrifog emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floors, complete all as specified and directed by engineer-in-charge.
Demolition of cement concrete/terrazzo flooring in floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed by engineer-in-charge.
M&L for light shade ceramic tiles 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by engineer-in-charge.
M&L for light shade ceramic tiles 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm, as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by engineer-in-charge.
Demolition floor tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by engineer-in-charge.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by engineer-in-charge.
Dismantling wall tiles of any description or thickness in wall, aprons etc laid bedded and pointed in any mortar, complete all as specified and directed by engineer-in-charge.
M&L for joint free glazed ceramic coloured tiles in vertical surface 450x300x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed by engineer-in-charge.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6, complete all as specified and directed by engineer-in-charge.
M&L for backing coat/ plaster 10 mm thick on fair faces of brick work in CM 1:4 surfaces to receive tiles, complete all as specified and directed by engineer-in-charge.
Dismantling stone slabs and tiles of any discription or thickness in floors, aprons etc, laid bedded and pointed in any mortar, complete all as specified and directed by engineer-in-charge.
M&L for granite (of any type) work, 20 mm thk (table rubbed and polished) in steps,jambs,pillars, window-cills, cooking platforms and like in 20mm thick screed bed cement screed bed 1:6 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by engineer-in-charge.
M&L for machine cut pre-polished kota stone slab flooring 18-20mm thick over 20mm thick cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, complete all as specified and directed by engineer-in-charge.
M&L for pre-polished kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, complete all as specified and directed by engineer-in-charge.
M&L for udaipur green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
Demolition of brick work built in cement mortar or cement lime mortar, complete all as specified and directed.
M&L brick work with sub class `B' bricks straight or curved on plan exc. 6mtr mean radius built in cement mortor 1:6, complete all as specified and directed by engineer-in-charge.
M&L brick work with sub class 'B' bricks strainght or curved on plan to any radius in half thick in CM 1:4 brick wall built in cement mortor, complete all as specified and directed by engineer-in-charge.
Taking up or down steel tubing and connections including cleaning for re-fixing, 15 mm bore of pipe, complete all as specified and directed by engineer-in-charge.
All as per item no -63- here in before but 20 mm bore of pipe, complete all as specified and directed by engineer-in-charge.
S&F 15 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid floors or concealed, complete all as specified and directed by engineer-in-charge.
All as per item no -65- here in before but 20 mm bore of pipe, complete all as specified and directed by engineer-in-charge.
Re-fixing old steel tubing, bore of pipe in 20mm and connections including connections in new or old position (walls, ceiling, floors, etc) complete all as specified
Re-fixing old steel tubing, bore of pipe in 15mm and connections including connections in new or old position (walls, ceiling, floors, etc) complete all as specified
Cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and directed by engineer-in-charge.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres, complete all as specified and directed by engineer-in-charge.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks of white colour (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed by engineer-in-charge.
S&F ball brass valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball ascrewed for iron pipe of 20mm bore and fixed, complete all as specified and directed by engineer-in-charge.
S&F in repairs gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore, complete all as specified and directed by engineer-in-charge.
S&F PVC connections 450mm long with brass unions at both ends suitable for 15mm bore pipe, complete all as specified and directed by engineer-in-charge.
S&F in repair 15 mm angle valve/ stop valves, cast copper alloy , chromium palted, fancy type screwed down high pressure with crutch and butter fly handles , screwed with iron pipes or for union, complete all as specified and directed by engineer-in-charge.
M & L Stop valves, cast copper alloybut fancy type, chromium plated with long shank and cup (concealed type) , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in repairs bib tap (quarter turn), brass chromium plated fancy type, long body with flange screwed down, screwed for iron pipe 15 mm bore, complete all as specified and directed by engineer-in-charge.
S&F mixing valve 15 mm dia, CP brass fancy including joints to steel pipe or unions for centre hole wash hand basin for mixing hot and cold water, including fittings, complete all as specified and directed by engineer-in-charge.
S&F in repairs chromium plated grating with 100mm dia of approved make includingh fixing with 1:4 CM to floor/ nahni trap etc., complete all as specified and directed by engineer-in-charge
S&F in repairs grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms) etc., complete all as specified and directed by engineer-in-charge.
S&F in repairs brass chromium plated overhead shower rose 125mm dia, with revolving joint and shower rod to fixed to 15mm bore pipe, complete all as specified and directed by engineer-in-charge.
S&F brass chromium plated tubular towel rail, 20mm dia, 'D' type 60cm long between flanges of brass CP, complete all as specified and directed by engineer-in-charge.
S&F in repair stainless steel sinks without drainage board made of stainless steel 01mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed by engineer-in-charge.
S&F brass chromium plated health faucet alongwith 1.00 to 1.50 meter good quality SS flexible connection pipe suitable for 15mm bore pipe, complete all as specified and directed by engineer-in-charge.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) , white fixed in repair,including sheet cover of closed pattern with flat bottom and mild steel chromium plated or aluminiumised hinging device, complete all as specified and directed by engineer-in-charge.
S&F in repair, PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level, complete all as specified and directed by engineer-in-charge.
S&F in repair vitreous china wash basin, white, angle back, size 400 x 400mm, including necessary waste pipe and coupling, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed by engineer-in-charge.
S&F 6mm thick glass corner shelf fancy type with railing and fittings complete of size 25cm x 25cm of best quality (as per sample approved by Engr-in-charge), complete all as specified and directed by engineer-in-charge.
S&F brass chromium plated soap dish 150mmx150mm, of any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed by engineer-in-charge.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames), complete all as specified and directed by engineer-in-charge.
All as per item no - 91- here in before but exceeding 1.50 sqm and not exc. 4.00 sqm each, complete all as specified and directed by engineer-in-charge.
Taking down shutter of any descreption exc. 1.00 sqm but not exc. 2.00 sqm each, complete all as specified and directed by engineer-in-charge.
S&F pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed by engineer-in-charge.
S&F factory made solid PVC chowkhat/ door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet and edges will be painted to match with printed PVC sheet reinforced with 19mm x 19mm MS square tube of 19 gauge including rubber gasket, PVC fastners, screws, brackets, and shown on drawing as per SSR part-II (2020), complete all as specified and directed by engineer-in-charge.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick wood grain printed moulded prelam PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified and directed by engineer-in-charge.
S&F 35 mm thick Factory made IInd class hardwood plain,framed paneled shutters (any numbe of panels) with lock rail and panel of 9mm BWP commercial ply with commercial veneering on both faces size of rail and stile as per IS-1003 (part) Kiln seasoned and chemically pressure treated, complete all as specified and directed by engineer-in-charge.
S&F 35 mm thick factory made IInd class hard wood glazed and Skelton shutters (three panels) open rebated and prepared to receive glass/ gauge etc. divided into squares edges of framing plain, chamfered or rounded mitered and rebated sash bar any number with cut or mitered beads for securing glass/ gauge etc. size of members of shutters, complete all as specified and directed by engineer-in-charge.
S&F stainless steel butt hinges, size 100 mm complete, complete all as specified and directed by engineer-in-charge.
S&F stainless steel barrel tower bolts, 150 mm long, complete all as specified and directed by engineer-in-charge.
S&F stainless steel handles, 150 mm long, complete all as specified and directed by engineer-in-charge.
S&F stainless steel sliding door bolts 250mm long with hasp, staple (bolt type) fixing clips of sheet cast, fixing bolts, complete all as specified and directed by engineer-in-charge.
S&F in repair stainless steel wire cloth, 0.63mm nominal dia or wire and sqm average width or aperature 1.40mm, fixed with tinned tacks or galvanised wire staples to doors/steel windows, complete all as specified and directed by engineer-in-charge.
S&F stainless steel wire cloth, 0.63mm nominal dia or wire and sqm average width or aperture 1.40mm, fixed with tinned tacks or galvanized wire staples to doors/steel windows, complete all as specified and directed.
S&F in repair stainless steel barrel tower bolts, 150 mm long, complete all as specified and directed by engineer-in-charge.
S&F in repair stainless steel handles, 150 mm long, complete all as specified and directed by engineer-in-charge.
S&F in repair stainless steel sliding door bolts 250mm long with hasp, staple (bolt type) fixing clips of sheet cast, fixing bolts, complete all as specified and directed by engineer-in-charge.
M&L powder coated aluminium anodised three way track sliding windows of frame size 92 mm x 31.75 mm x 1.5mm thickness (section no. 20831 of JINDAL) and of shutter size 40 mm x 18 (with 9.00 mm interlocking legs) x 1.45 mm thick (section no. 20737 of JINDAL) section (two shutter glazed, covering half of span of opening each & one shutter sketlon covering half of span of opening ) incl provn for making windows air tight, including 95mm aluminium handle with spring lock , stainless steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.4mm and fixed with steel wire stapples 5mm thick plain glass including necessary fitting/ fixture/ aluminium snap beads, complete all as specified and directed by engineer-in-charge. (Note Measurement shall be taken clear opening ie out to out of window frame as a whole including all fittings and fixtures and no extra shall be paid separately.
S&F fabricated aluminum window with powder coated anodized aluminum frame of section 63.5mm x 38.10mm x1.5mm thick, shutter with section 47.62mm x 44.45mm x 1.5mm thick including aluminum anodized “D “ handle, hinges, peg stays, tower bolts, etc including jointing cleats for fixing builder's hardware fittings & stainless steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples including necessary fittings/fixture /aluminum snap beads, complete all as specified and directed by engineer-in-charge.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed by engineer-in-charge.
M&L for 18mm thick wood plastic composites (WPC) board, fixed with screws as in cupboard/ wardrobe/ almirah shutter including all necessary fittings and fixtures like nickle plated clip hinges, knobs etc complete all as specified and directed. Note: (a) Pattern & design of WPC board to be decided by GE. (b) Items like cupboard knobs, and CP plate clip hinges deemed to be included in the quoted rate.
S&F in repair drapery curtain rods, stainless steel 25 mm dia of approved quality with decorative wooden finish and two number brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod including 8 Nos (min) match up rings etc., complete all as specified and directed by engineer-in-charge.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, welded or forged into spikes, framed guard bars, window frames, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work fixed in position including holdfasts or screws confirming to Fe.290.Gde-E-165, complete all as specified and directed by engineer-in-charge.
M&L for welding in repairs exc 2.5 cm but not exc. 5.0 cm in length thickness of metal be welded exc 6mm but n.exc 9mm, complete all as specified and directed by engineer-in-charge.
S&F MS stainless steel peg set of five fixing with wall, complete all as specified and directed by engineer-in-charge.
S&F in repair kitchen plate rack with four shelves made out of stainless steel sheet 1 mm thick overall size 750mm x 750mm x 250mm, complete all as specified and directed by engineer-in-charge.
Demolition of cement concrete (un reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed by engineer-in-charge.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection, 75 mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight, complete all as specified and directed by engineer-in-charge.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base, complete all as specified and directed by engineer-in-charge.
M&L for 60mm thickness machine pressed pre-cast concrete interlocking paver block any size and shape confirming to IS 15658-2006, M-30 grade with grey cement and no pigment, laid over 40mm thick sand cushion and including joints filled with sand, complete all as specified and directed.
Taking down carefully the old U/S Copper point wiring (light, fan, socket or power) complete Fitting such as switch, ceiling roses,pendants,socket, regulators , all type light Fitting, security light Ding Dong Bell , etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqm nominal area PVC insulated FRLSH 1100 Volts grade electrical cable in and including concealed PVC conduit medium grade and Modular sunken pressed steel terminal box 2 mm thick required size including modular plate and modular flush box in different module with all accessories including 1.5 Sqm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and directed by Engr-in Charge Note :- The rate is inclusive cutting/chasing and making good disturbed surface with CM 1:3 and same surface finishs with the adjoining surface of disturbed area with OBD/Colour wash/white wash complete.
One light /fan/Bell point/security light controlled by one way switch
One 3 pin socket outlet 5 amps on same board
One 3 pin socket outlet 5 amps point independent board with cable 1.5 Sqmm for main current and 1.5 sqmm as earth wire as power point complete all as specified and directed
One 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point complete all as specified and directed.
One 3 pin socket outlet, 15 amps on independent board with cable 4 Sqmm for main current and 4 sqmm as earth wire as power point complete all as specified and directed.
One light point controlled by two 2-way switch 230 volts complete all as specified and directed.
S & F Switch Modular type switch, 6 A 1- way SP switch complete all as specified and directed by Engineer in Charge
S & F modular type 2/3 pin combined shuttered type 6A socket,complete all as specified and directed by Engineer in Charge
S & F Switch Modular type switch, 6 A 2- way SP switch complete all as specified and directed by Engineer in Charge
S & F Switch Modular type switch, 16 A 1- way SP switch complete all as specifiedand directed by Engineer in Charge
S & F modular type 2/3 pin combined shuttered type 16 A socket, complete all as specified and directed by Engineer in Charge
S & F ceiling rose complete all as specified in IS 732:2019 and directed by Engineer in Charge
S&F electric bell ding dong AC, 230 volts single phase complete all as specified and directed.
S&F Bell push modular type 1M 5/6 Amp complete all as specified and directed.
S & F AC modular box with mcb 20 Amps complete all as specified and directed by Engineer in Charge
S & F 20 Watt surface / wall mounted LED batten capable of delivering minimum 2000 lumen having PC diffuser luminius efficincy not less thn 115 lumen/Watt CRI>80% PF>0.9,CCT 6500K indeoendent isolated SPMS based constant current electronic LED driver with THD < 10% surge protection and other safety tests as per IS 15885( Part-2/Sec-13) : 2012 polycarbonate diffuser housed in power coated white extruded aluminium channel housing , white coloured ABS end caps IP 20 protection input voltage range 140-270V input fequency 50-60Hz including electrical connection with 3 core flexible Cooper Cunductor cable of Appropriate size from ceiling rose to the fixture complete all as specified and directed by Engineer in Charge
Refixing of old serviciable LED batten 4 Feet of any capacity retrived from item no 01 here in before including electrical connection with suitable size of flexible wire as required complete all as specified and directed by Engr-in-Charge.
S & F 10 Watt surface / wall mounted mirror LED batten capable of delivering minimum 1150 lumen having PC diffuser luminius efficincy not less thn 115 lumen/Watt CRI>80%, PF>0.9,CCT 6500K indeoendent isolated SPMS based constant current electronic LED driver with THD < 10% surge protection nd other safety tests as per IS 15885( Part-2/Sec-13) : 2012 polycarbonate diffuser housed in power coated white extruded aluminium channel housing , white coloured ABS end caps IP 20 protection input voltage range 140-270V input fequency 50-60Hz including electrical connection with 3 core flexible Cooper Cunductor cable of Appropriate size from ceiling rose to the fixture complete all as specified and directed by Engineer in Charge
S& F10 Watt Bulk Head capable delivering 1150 lumen having luminius efficiency not less than 115 lumen/watt starting time <.5 s CRI>80%, PF>0.9,IP-65, CCT 6500K input voltage range 140-270V input fequency 50-60Hz complete all as specified and directed by Engineer in Charge
S&F inverter LED lamp 12 Watt rechargeable for home, cool daylight, Base complete all as specified and directed
S& F 06 Watt surface mounted round shape LED downlighter capable delivering 1200 lumen having luminius efficiency not less than 115 lumen/watt starting time <.5 s CRI>80%, PF>0.9,CCT 6500K input voltage range 140-270V input fequency 50-60Hz anb B22 socket complete all as specified and directed by Engineer in Charge
Refixing of old serviciable Down lighter of any capacity retrived from item no 01 here in before including electrical connection with suitable size of flexible wire as required complete all as specified and directed by Engr-in-Charge.
S & F of Decorative wall light mounting suitable for LED Lamp upto 15 Watt complete with all connections all as specified and directed.
S & F 45 Watt security light high efficiency long life LED module with LENS type LED package mounted on MCPCB, Fixture should have minimum efficiency at system level >=110 lumens/Watt, integral SMPS based constant current electronic LED driver with THD<10% surge voltage protection of > 5.0 KV, CRI>80, PF>0.95,CCT 4000-6500K and other safety tests as per IS:15885( part-2/sec-13),IP 66 protection high efficiency polycarbonate cover with integrated lens housed in pressure die cast aluminim alloy heat sink for effective thermal management strudiness excellent corrosion resistance separate optical and control gear compartment & Top opening for easy maintanance suitable for side entry wall mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible copper cunductor cable of appropriate size and 1.5m long bracket having 40mm diameter light grade GI pipe including GI clamp nuts bolts & washers with two coats of synthetic enemal paint over a coat of oxide primer complete all as specified and directed by Engineer in Charge
S&F BLDC (Brushless DIrect Current) Ceiling fan, 1200 mm with Remote control, not less than 350 RPM, not less than Air delivery 220 CFM with service value 6.00 BEE, 5 Star , voltage 230V, high air follow with silence operation, having full copper winding & ribbed blade 3 Nos A/M blades. The BLDC motor fan shall have 100% rust free blade including taking down old ceiling fan and depositing to MES store yard complete all as specified and directed
S&F in replacement of VTPN 6 Way double door mettalic DB for fixing MCCB 4 Pole up to 250 Amps as incommer suitable for flush / surface mounting having 250 A copper busbar fully shrouded neutral bar earth bar wire sey & cable ties for cable management pre fiited sheet etc. complete all as specified and directed by Engineer in Charge
S&F in replacement of MCCB 4 pole,160 Amps, 415 Volts with 16 KA including electrical connection with incomer with appropriate size of aluminium lugs and insulation packing complete all as specified and directed.
Supply and fix in replacement of SPN 12 Way double door mettalic DB suitable for flush / surface mounting having 200 A copper busbar fully shrouded neutral bar earth bar wire set & cable ties for cable management pre fiited sheet etc.complete all as specified and directed by Engineer in Charge
M&L in replacement MCB SPN 'C' curve 63 Amps 240 Volts , 10 KA complete all as specified and directed.
M&L in replacement MCB SP 'C' curve 06 to 32 Amps 240 Volts 10 KA complete all as specified and directed.
M&L in replacement MCB SP 'C' curve 63 Amps 240 Volts 10 KA complete all as specified and directed
S &F in replacement for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing as directed by Engr-in-Charge.
M & L Earth continuity conductor or main earthing lead fixed on wall/ceiling in batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed on poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire.
Taking down unserviceable Submain wiring of any size complete and making good disturbed surface complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 10 Sqmm, 450/1100 Volts grade on & including PVC Conduit 25 mm medium grade complete with conduit accessories and copper cable 10 sqmm continuous earth wire complete all as specified and directed. (Two runs of cable with 01 earth wire shall be measured as one length) Note:- the rate is inclusive of taking down old submain wiring, making good the disturbed surface and same surface finishes with the adjoining surface of disturbed area ie with OBD/colour wash/white wash and wall putty where ever required.
Taking down of water storage heater 25 Ltr and keeping in safe custody and refixing it back after completion of point wiring including all necessary connection complete all as specified and directed at site.
Taking down and re-fixing single phase static energy meter in meter box in and including its connection complete and mounting on existing wall surface including necessary connections of incoming and out going cables. as specified and directed by Engr-in-charge.
S&F in replacement Sheet metal enclosure of size 350 x300 x 150 mm suitable for mounting Single phase electric meter fabricated from 2mm thick CRCA sheet with anti corrosive dust and vermin proof including taking down meter and refix after completion of wiring work including connection with 6 Sqmm wire from DB to Meter . Note:- The meter cover shall have a fully transparent window. The window shall be of transparent, high grade UV stabilized engineering plastic for easy reading of all the displayed values/parameters and observation of operation indicator. The window shall preferably be an integral part of meter cover all as specified and directed.
Taking down of exhaust fan of any size and keeping in safe custody and refixing it back after completion of point wiring complete all as specified and directed at site.
M & L for excavation of existing LT cable of any size and taking it out from the floor/protection pipe and including incomer electrical connection of in 4P MCCB of VTPN with suitable size of thimble complete with retirning filling and make good of excavated surface / floor complete all as specified and directed by Engr-in Charge
S&F 16 A, 30MA Earth leakage circuit breaker 1P+N C16 ELCB complete with two way sheet Metal Enclosure Distribution board for geyser complete all as specified and as directed.
Taking down unserviceable UG Cable of any size complete and making good disturbed surface complete all as specified and directed.
Supply & fixing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and as directed by Engineer In Charge.
Excavating in trenches n. exc 1.5 mm wise and n.exc 1.5 m in depth for laying under ground cable n.exc 10 sq m on plan and n.exc 1.5 m in depth and getting out in soft/loose soil/ Hard standing complete all as specified and as directed by Engineer In Charge.
Returning and filling including spreading, levelling, watering and well ramming inlayers n.exc 25cm thick in hard/dense soil/Soft loose soil/ Hard standing complete all as specified and as directed by Engineer In Charge.
Removing excavated material (soil) to a distance n.exc 50 m where directed at a lever not exc 1.5m above the starting point complete all as specified and as directed by Engineer In Charge.
M&L for sand filling under floors or in foundatins includng watering and consolidation/trenches below and around under ground cables for cushioning of calbes etc complete all as specified and directed.
Supply and laying Bricks common burnt clay building bricks sub class A designation 75, size 230mmx115mmx75mm complete all as specified and directed.
Supply and laying High density polyethylene(HDPE) pipes of pressure rating 6kgf/sq.cm (IS marked) and laid in trenches/under roads/ in drains/fixed to poles/walls of size 50 mm Dia complete all as specified and directed.
A R construction (BID ID -3129462)
M/S Chhavi Constructions Co (BID ID -3136599)
A N BUILDERS (BID ID -3129262)
P R Constructions (BID ID -3136929)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .