Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹4.7 L+₹12,502.10 (2.71%)Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L2 | STANDARD CAPACITORS L1 |
|---|---|---|---|---|---|
| 1.01 | REPAIR/RENOVATION OF APFC Panel 100 kVAr: 01 No. Dismantling of defective capacitor units from the APFC panel after suitably discharging the left-over charge on capacitors to ensure safety of the working persons along with dismantling of APFC relay, indications lights, meters, A/M switches, MCBs including dismantling of terminations and existing hardware and rusted parts and various other items requiring change in the panel as required at site | 1 | Job | 12,500 ₹14,750 | 9,500 ₹11,210 Lowest |
| 1.02 | Replacement of defective Heavy Duty Capacitor units of various capacities with new capacitor units, rated at 440 V, 3 phase, 50 Hz system complete with terminal cover, cable end entry, mounting structure and hardware etc. Make:- Standard | 100 | KVAR | 36,000 ₹42,480 Lowest | 44,500 ₹52,510 |
| 1.03 | Banking of capacitors of various capacities with multistrand copper wires & lugs /aluminium bus bars and mounting arrangement for parallel connection to form suitable rating capacitor bank | 100 | KVAR | 9,000 ₹10,620 Lowest | 14,500 ₹17,110 |
| 1.04 | Replacement of defective APFC relay, with new microprocessor based APFC Relay having digital display of power factor and other parameters to sense power factor through control CT and give phased impulses to contactor coils for switching ON-OFF required number of capacitors as per requirement to achieve target power factor. Make :- Standard. | 1 | No. | 22,700 ₹26,786 Lowest | 23,000 ₹27,140 |
| 1.05 | Programming of APFC relay for target power factor including setting of various parameters and keeping updated indications of the efficiency of electrical power usage, and improving it for reducing the power losses and avoid penalties from utility companies. | 1 | Job | 12,500 ₹14,750 | 8,500 ₹10,030 Lowest |
| 1.06 | Replacement of defective capacitor duty contactors suitable for 25 KVAr capacitor with new capacitor duty contactor. Make :- Standard. | 4 | Nos. | 19,920 ₹23,505.6 Lowest | 21,600 ₹25,488 |
| 1.07 | Replacement of defective capacitor duty contactors suitable for 15 KVAr capacitor with new capacitor duty contactor. Make :- Standard. | 3 | Nos. | 11,760 ₹13,876.8 | 10,500 ₹12,390 Lowest |
| 1.08 | Replacement of defective capacitor duty contactors suitable for 10 KVAr capacitor with new capacitor duty contactor. Make :- Standard. | 3 | Nos. | 8,850 ₹10,443 | 8,400 ₹9,912 Lowest |
| 1.09 | Replacement of defective triple pole MCB of 32 A capacity with new MCB for operation and safety of individual capacitor bank. Make :- Standard. | 1 | No. | 1,150 ₹1,357 Lowest | 1,320 ₹1,557.6 |
| 1.10 | Replacement of Ammeter 0-500A ammeters with CT and selector switch for replacement of defective meters. Make :- AE/Standard. | 2 | Set | 8,000 ₹9,440 | 6,400 ₹7,552 Lowest |
Tender Value
Refer Docs
EMD Value
₹9,400
Closing Date
30 Jan 2026, 11:00 amClosed
Office of the Ex. Eng. (E and M) M-2
Pocket-A, Dilshad Garden, Delhi-110095
Repair/Renovation of Standard make APFC panel with allied electrical work at W-II Ranney well Wazirabad Road near Nanaksar Gurudwara.
2026_DJB_285639_4
NIT No. 25 (25-26)
Open Tender
Miscellaneous Works
Works
30 days
W-II Ranney well Wazirabad Road near Nanaksar Guru
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Ac No. 50448339804
₹9,400
2 Feb 2026
24 Jan 2026
30 Jan 2026
24 Jan 2026
30 Jan 2026
24 Jan 2026
REPAIR/RENOVATION OF APFC Panel 100 kVAr: 01 No. Dismantling of defective capacitor units from the APFC panel after suitably discharging the left-over charge on capacitors to ensure safety of the working persons along with dismantling of APFC relay, indications lights, meters, A/M switches, MCBs including dismantling of terminations and existing hardware and rusted parts and various other items requiring change in the panel as required at site
Replacement of defective Heavy Duty Capacitor units of various capacities with new capacitor units, rated at 440 V, 3 phase, 50 Hz system complete with terminal cover, cable end entry, mounting structure and hardware etc. Make:- Standard
Banking of capacitors of various capacities with multistrand copper wires & lugs /aluminium bus bars and mounting arrangement for parallel connection to form suitable rating capacitor bank
Replacement of defective APFC relay, with new microprocessor based APFC Relay having digital display of power factor and other parameters to sense power factor through control CT and give phased impulses to contactor coils for switching ON-OFF required number of capacitors as per requirement to achieve target power factor. Make :- Standard.
Programming of APFC relay for target power factor including setting of various parameters and keeping updated indications of the efficiency of electrical power usage, and improving it for reducing the power losses and avoid penalties from utility companies.
Replacement of defective capacitor duty contactors suitable for 25 KVAr capacitor with new capacitor duty contactor. Make :- Standard.
Replacement of defective capacitor duty contactors suitable for 15 KVAr capacitor with new capacitor duty contactor. Make :- Standard.
Replacement of defective capacitor duty contactors suitable for 10 KVAr capacitor with new capacitor duty contactor. Make :- Standard.
Replacement of defective triple pole MCB of 32 A capacity with new MCB for operation and safety of individual capacitor bank. Make :- Standard.
Replacement of defective/burnt out LED indication lights of various colours with new indication lights. Make :- Standard.
Power wiring with 10 sq. mm multistrand copper wires for connection between capacitors and bus bar using copper lugs and necessary hardware etc. as required at site.
Installation of all above components in the existing capacitor banks with suitable fabrication work to accommodate new items in the existing enclosure / structure for alignment of components and ease of termination, complete with hardware on the mounting structure and termination of existing cables with lugs, tapes etc. complete with earthing of the capacitor banks, touching the rusted parts of the panel structure with paint for protection from moisture etc. as required at site
Servicing of APFC panels including complete dusting of the panel, cleaning of contact points, Decarbonising of joints, alignment of doors, checking of all nuts & bolts, control circuit and power circuit wiring dressing and renovation of control and power terminations etc. as required at site
Testing & Commissioning of complete APFC Panel installation including following: 01. Meggering of complete capacitor installation using 500V megger. 02. Continuity test for checking continuity of all circuits to ensure that all circuits are properly wired. 03. Checking function and efficiency of various components of APFC panel.
Monitoring of Power Factor during warranty period including checking of efficiency of capacitors and other equipment to ensure that APFC panel is working to its highest capacity for achieving target power factor.
REPAIR RENOVATION OF LT STARTER PANEL. Dismantling of defective components from the LT panel after suitably checking live parts to ensure safety of the working persons along with dismantling of Timer, Contactors, MCCB, single phase preventor, MCBs including dismantling of terminations and existing hardware, rusted parts and various other items requiring change in the panel as required at site.
Supply of triple pole Contactor model MNX -95 of L&T make or equivalent item of Schneider, Havells make to replace defective Contactor in the LT panel.
Supply of triple pole Contactor model MNX -70 of L&T make or equivalent item of Schneider, Havells make to replace defective Contactor in the LT panel.
Supply of Over Load Relay. Make - L&T/GIC
Supply of Timer to replace defective Timer in the LT panel. Make - CIC
Supply of Single-Phase Preventer (PSR) to replace defective Single-Phase Preventer in the LT panel. Make - GIC
Supply of LED indication lights of various colours to replace defective/burnt out lights make -standard
Painting of the panel including treatment with electrical solution for removal of rust etc. rubbing for clearing rusted particles, applying the coat of primer & thereafter spray painting with matching paint shade to ensure uniformly.
Control wiring with 1.5 sq mm for connection between contactor and timer & Bus bar with copper lugs and necessary hardware etc. as required at site.
Power wiring with 16 sq mm for connection between Contactor and MCCB & bus bar with copper lugs and necessary hardware etc. as required at site.
Servicing of LT panel including complete dusting of the panel, cleaning of contact points, Decarbonising of joints, alignment of doors, checking of all nuts & bolts control circuit and power circuit wiring dressing and renovation of control and power terminations with lugs tapes etc. as required at site
Fixing of all above components in the LT panel with suitable fabrication work to accommodate new items in the existing feeders for alignment of components and ease of termination complete with hardware etc. as required at site
Testing & commissioning of LT Stater Panel as per required parameters including following :- i. Continuity and earth test, ii Programming of Electronic Motor Protection Relay. ii. Meggering of all equipment's for phase to phase and phase to earth. iii. Checking of tightness of all nut and bolts. iv. Monitoring of power factor
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
BOQ_377991.xls
BOQ • 0.27 MB
NIT.pdf
Tender Documents • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .