Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.8 LAccepted-AOC HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹19.7 L+₹54,010 (2.82%)Rejected-Finance EAST DIGHI TANK OLD LIC COMPOUND GAYA BIHAR 823001 | GAYA | BIHAR | 823001 | 2 | Rejected-Finance NOT BEING LOWEST. | |
| 3 | 3₹28.8 L+₹9.7 L (50.6%)Rejected-Finance SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | 3 | Rejected-Finance NOT BEING LOWEST. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Jan 2020, 6:00 pmClosed
Garrison Engineer Gaya
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar 823001
Repair/ Maint of refrigeration, air conditioning and allied works at Mil Stn Gaya
2019_MES_306505_1
8041/GE/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE GAYA
₹60,000
Yes
23 Jan 2020
14 Dec 2019
10 Jan 2020
14 Dec 2019
9 Jan 2020
28 Dec 2019
Amount
S&F in replacement of heating element 1.5 KW of any type (Trangular/Threaded/ Cup type) for geyser 25 ltr capacity complete all as directed at site (work will be executed at site where geysers installed.).Make-Bajaj/Roxy/Havells
S&F in replacement of heating element 2 KW of any type (Trangular/Threaded/ Cup type) for geyser 50 ltr capacity complete all as directed at site (work will be executed at site where geysers installed.).Make-Bajaj/Roxy/Havells
S&F in replacement of heating element 3 KW of any type (Trangular/Threaded/ Cup type) for geyser 200/300 ltr capacity complete all as directed at site (work will be executed at site where geysers installed.).Make-Bajaj/Roxy/Havells
S&F in replacement of indicating lamp round/flat type as per existing suitable for 25/35/50 ltr capacity geysers complete all as directed at site.Make-Bajaj/Roxy/Havells
S&F in repair fusible plug for any size of geyser.
S&F for replacement of unserviceable thermostatic 60-80*C ISI marked for 25/50 ltr capacity geysers complete all as directed at site.Make-Bajaj/Roxy/Havells
S&F in replacement of safety valve dead weight type (ISI marked) best quality size 15mm suitable for 25/35/50 ltr capacity geysers complete all as directed at site.
Taking down and opening of geysers 25/50 ltr capacity for examining inner shell of copper and repairing the same by brazing at the point of leakage and testing complete on completion including refixing the geyser after repair.
S&F in replacement of flexible connection pipe heavy duty braided hose PVC Pipe 600mm Long (15mm Dia) of superior quality as per existing pattern with brass union & washer fitted at both end suitable to 15mm GI pipe line complete.
S&F in replacement of rubber gasket for apparatus plate assembly
S&F in replacement of non return valve of 15mm dia of brass good quality as approved by Engr-In-Charge.
M & L for taking down and spray painting to geyser of 25 & 50 ltr capacity at site where installed and painting with synthetic enemal paint including filling of cavities with approved filler complete and refixing in position after drying.
M&L for replacement of plug top 15/16 Amp ISI marked.Make-Bajaj/Roxy/Havells/Anchor
S&F replacement of thermal cut-out suitable for 25/35/50 litre Geyser system of ISI marked.Make-Bajaj/Roxy/Havells
M&L replacement of socket outlet 2 in 1 , 5 Pin 5 & 15 Amps, 230 Volts AC circuit complete all as specified and directed.Make-Anchor/havells
M&L replacement of Switch piano flush type single pole, one way 15 Amps 230 Volts AC circuit complete all as specified & directed.Make-Anchor/havells
M&L replacement of Switch socket combination 2 in 1 ,3 pin 5 &15 Amps, 230 Volts AC circuit complete all as specified and directed.Make-Anchor/havells
S&F replacement of metallic top 25 Amp capacity complete all as specified. Make: Havelles/Anchor/ Standard.
S&F replacement of Hot Water Heater 25 Ltr ,230Volts including fixing on wall through proper nut, bolt ,fastner etc with and including wire connected to top plug complete all as specified and directed. Make-Bajaj/Havells .(Old Hot Water Heater Should be deposited to MES store yard)
Recharging of freon gas only after rectification of leakage for refrigerator 310/285/180/165 ltrs capacity upto required level including testing complete all as specified and directed by Engr-in-Charge. Note-The quantity of gas should be measured and paid separately.
Recharging of freon gas only after rectification of leakage for water cooler of any size complete all as specified and directed by Engr-in-Charge. Note-The quantity of gas should be measured and paid separately.
Recharging of freon gas only after rectification of leakage for window/split type AC 1/1.5/2 ton capacity after cooler of any size and capacity. Note-The quantity of gas should be measured and paid separately.
Taking out old burnt out compressure (sealed unit) for Refrigerator 170/210/285/310 ltr capacity and replaced with new one compressure as per existing make including charging of gas upto required level and testing complete all as specified and directed by Engr-in-Charge. Note-The quantity of gas should be measured and paid separately.
M&L for replacement of copper tube of size 6mm dia complete as specified and directed by Engr-in-Charge.
M&L for replacement of starting relay box type for refrigerator complete as specified and directed by Engr-in-Charge.
M&L for replacement of thermostat switch for refrigerator of any size make- Danfoss or equivalent
M&L for replacement of Bulb secrew/pin type for refrigerator complelte all as specified and directed by Engineer-in-charge.
M&L for replacement for door gasket with magnetic strip for refrigerator 310/285/165 ltrs capacity all as specified.
M&L for replacement of freezer chest including front cover with spring or clamp complete including fixing to refrigerator all as specified for 310/285/165 ltrs capacity as per sample.
Taking out old burnt out compressure (sealed unit) complete from window/split type and replaced with new one compressure including charging of gas upto required level for 1.5 Ton capacity and testing complete all as specified and directed by Engineer-in-charge .Make-Kirloskor/Godrej/Blue Star Note-The charging of gas should be measured and paid separately.
M&L for replacement of thermostat switch as per sample suitable for window/split AC 1.5/2 Ton capacity complete all as specified and directed by Engineer -in-charge
M&l for replacement of starting relay box type as per sample suitable for window AC 1.5/2 Ton capacity complete all as specified and directed by Engineer -in-charge
M&L for replacement for running capacitor suitable for window/split AC 1.5/2 Ton capacity as per same complete all as specified and directed by Engineer-in-charge.
M&L for starting capacitor 60-80 MFD suitable for window/split AC 1.5/2 Ton capacity complete all as specified and directed by Engineer-in-charge .
M&L for rewinding fan motor window AC 1.5/2 Ton capacity complete all as specified and directed by Engineer-in-charge
M&L for rewinding of condensor fan motor of split AC 1.5/2 Ton capacity complete all as specified and directed by Engineer-in-charge
M&L for rewinding of eveporator fan motor of split AC 1.5/2 Ton capacity complete all as specified and directed by Engineer-in-charge
M&L for replacement of condenser coil by brazing and filling suitbale for window/split AC 1.5/2 Ton complete all as specified and directed by Engineer-in-charge.
M&L for replacement of evaporator coil by brazing and filling suitbale for window/split AC 1.5/2 Ton complete all as specified and directed by Engineer-in-charge.
M&L for replacement of electronic control kit for starting & running as per sample suitbale for split AC 1.5/2 Ton complete all as specified and directed by Engineer-in-charge.
Taking out old burnt out compressure (sealed unit) complete from water cooler of any size/capacity and replaced with new one compressure as per existing make including charging of gas upto required level and testing complete all as specified and directed by Engineer-in-cahrge. Note-The quantity of gas should be measured and paid separately.
M&L for rewinding blower motor of water cooler of any size capacity complete all as specified and directed by Engineer-in-charge
M&L for replacement of starting cum over load relay type with cover complete as per sample.
M&l replacement of running capacitor 20-30 MFD for water cooler.
M&L for replacement of starting capacitor 40-60 MFD suitable for water cooler.
S&F replacement of Voltage stabaliser copper winding (100%) for automatic operation single phase naturally cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabalised at 230 V with accuracy of +/- 2.5% and of capacity 1 KVA with high Voltage Cut off Protection complete. Make: V-Guard/Sen &pandit/Voltas (Old Stabaliser Should be deposited to MES store yard)
S&F replacement of Wall mounted Voltage stabiliser copper winding (100%) for automatic operation single phase naturally cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilised at 230 V with accuracy of +/- 2.5% and of capacity 4 KVA with high Voltage Cut off Protection completed.Make: V-Guard/Sen &pandit/Voltas (Old Stabaliser Should be deposited to MES store yard)
S&F replacement of Wall mounted Voltage stabiliser copper winding (100%) for automatic operation single phase naturally cooled indoor type & designed for input variation between 160 V to 250 V with output voltage stabilised at 230 V with accuracy of +/- 2.5% and of capacity 5KVA with high Voltage Cut off Protection completed.Make: V-Guard/Sen &pandit/Voltas (Old Stabaliser Should be deposited to MES store yard)
Supply only for charging of Freon gas in refrigerator, water coolar, Air condition Split type or window type, deep freezer of any capacity.
M&L Painting all expose surface including blades of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after scrapping cleaning all old paint etc including writing MES No complete all as directed at site.
M&L Painting all expose surface including blades of exhaust fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after scrapping cleaning all old paint etc including writing MES No complete all as directed at site.
Taking down carefully servicable/ unservicable ceiling fans/exhaust fans for day to day maint at site and re-fixing the same after greasing and replacing the unservicable spare parts. Note:- Spare parts shall be measured and paid separately under relevant item.
Supply only bush suitable for ceiling fan of any make, type & size. Make : NBC/SKF/Tata
Supply only ball bearing suitable for ceiling fan of any make, type & size. Make : NBC/SKF/Tata
Supply only condensor 2.5 Mfd oil filled metalic body. Make: unversal/EPCOS/USHA
Supply only condensor 3.15 Mfd oil filled metalic body. Make: unversal/EPCOS/USHA
Supply only condensor 4 Mfd oil filled metalic body. Make: unversal/EPCOS/USHA
Supply only flexible wire size 23/.0076 Make - Anchor/Havells/Plaza
M&L for re-winding the damaged burnt winding by taking out from ceiling fan armature of 1200 mm sweep , cleaning the slot and, rewinding with super enamelled copper wire of same grade and duly heating & varnishing including greasing/oiling and commissioning/ testing up to the entire satisfaction of Engr-in-Charge .
M&L for re-winding the damaged burnt winding by taking out from ceiling fan armature of 1400 mm sweep , cleaning the slot and, rewinding with super enamelled copper wire of same grade and duly heating & varnishing including greasing/oiling and commissioning/ testing up to the entire satisfaction of Engr-in-Charge .
M&L for re-winding the damaged burnt winding by taking out from exhaust fan armature of 300/350/400 mm sweep , cleaning the slot and, rewinding with super enamelled copper wire of same grade and duly heating & varnishing including greasing/oiling and commissioning/ testing up to the entire satisfaction of Engr-in-Charge .
S&F replacement of Plastic Exhaust fan 200mm sweep ,Energy saving fans ,230V AC ,50 HZ Completed. Make-Havells/Usha/Bajaj.
S&F replacement of ceiling fan 1200mm sweep ,Energy saving fans ,230V AC ,50 HZ complete. Make-Havells/Usha/Bajaj.(Old Ceiling Fan Should be deposited to MES store yard)
S&F replacement of steel body Exhaust fan 300mm sweep ,Energy saving fans ,230V AC ,50 HZ Completed. Make-Havells/Usha/Bajaj.
Taking out and Opening of solar water heater for examining inner shell and repairing the same ,replacement Heating element , Cut-out, Thermal state and testing complete on completion including refixing after repair.
Taking out old burnt out compressure (sealed unit) complete from window/split type and replaced with new one compressure including charging of gas upto required level for 2 Ton capacity and testing complete all as specified and directed by Engineer-in-charge .Make-Kirloskor/Godrej/Blue Star Note-The charging of gas should be measured and paid separately.
Supply and Laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10sqmm nominal cross section 2 core complete.
M&L Writing MES No and MES in black paint on Ceiling fan at site complete all as directed by engr-in-charge.
M&L Writing MES No and MES in black paint on Exhaust fan at site complete all as directed by engr-in-charge.
M&L Writing MES No and MES in black paint on splitAC/Window AC/Water cooler/ Desert Cooler/Refrigerator at site complete all as directed by engr-in-charge.
M&L Writing MES No and MES in black paint on Geyger at site complete all as directed by engr-in-charge.
S&F replacement of Hot Water Heater Digital type 25 Ltr ,230Volts including fixing on wall through proper nut, bolt ,fastner etc with and including wire connected to top plug complete all as specified and directed. Make-Bajaj/Havells .(Old Hot Water Heater Should be deposited to MES store yard) Note:-Attendance of contractor obtaining completion certifcate (Applicable for sch"A" Item No- 1 to 73) (i) Either contractor or his rep shall attend office of the AGE(E/M) on each Working day between 9.30AM and 10AM and shall receive complaint slip.All this complaints shall be rectified /completed by the contractor within a day.(24 hours) (ii) It will be responsibility of the contractor to obtain completion certificate from the User and handing over the same to the Engr-in-Charge .These completion certificate( dully signed by User/Engr-in- Charge and contractor )shal be kept in the MES record .(with Engr-in-Charge) (iii) In Case of any absence noticed in deploying labours or if retification is not carried out within 24 hours ,Recovery will be affected from the contractor Payment at the rate of double the qoated for each day of delay in BOQ. (iv) A Complaint register to this effect (receipt of dated and timed complaints and dated and time d desposal thereof ) shall be maintained by JE and countersigned by Engr-in-Charge.
M/s Vinay Kumar
M/S ABHAY KUMAR AND BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .