Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-Finance | L1 | Accepted-Finance Rate quoted is lowest | |
| 2 | L2₹8.4 L+₹2.4 L (40.1%)Accepted-Finance | L2 | Accepted-Finance Rate quoted is second lowest | |
| 3 | L3₹8.5 L+₹2.4 L (40.3%)Accepted-Finance | L3 | Accepted-Finance Rate quoted is 3rd lowest | |
| 4 | L4₹8.6 L+₹2.6 L (43.3%)Accepted-Finance | L4 | Accepted-Finance Rate quoted is second highest | |
| 5 | L5₹8.6 L+₹2.6 L (43.4%)Accepted-Finance | L5 | Accepted-Finance Rate quoted is highest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
18 Jan 2021, 4:00 pmClosed
Superintending Engineer
SE ETC Sultanpur 400KV S/S Campus Payagipur Sultanpur
CONSTRUCTION OF 132KV KHAJURAHAT TSS BAY FOR RAILWAY ALONG WITH EXTENSION OF 132KV MAIN AND TRANSFER BUS AT 132KV SUBSTATION BIKAPUR UNDER ETD, AYODHYA.
2021_UPTCL_544200_1
S.T. T.No. 106/ETCS/2020-21
Open Tender
Electrical Works
Item Wise
60 days
Sultanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE ETC Sultanpur
₹10,000
Yes
29 Jan 2021
7 Jan 2021
19 Jan 2021
7 Jan 2021
18 Jan 2021
7 Jan 2021
7 Jan 2021 - 18 Jan 2021
Amount
PART - A - Work (Erection of 132/33KV Transformr Bays (HT & LT) Erection of following equipments including shifting of material from store to site including proper fixing with other relevent jobs to complete the work in proper way as per UPPTCL Norms: -
145KV SF6 Circuit Breaker
145KV Current Transformer
145KV C.T. Junction Box
145KV P.T. Junction Box
145KV Bus Isolator
145KV Line Isolator
145KV Post Insulators
120KV Surge Arrester
132KV Feeder Control & Relay Protection Panel as per technical specification for SAS
Laying of following 1.1KV unarmoured copper control cable in cable trenches with other relevent jobs to complete the work in proper way as per UPPTCL Norms: -
Termintion of following 1.1KV unarmoured copper control cable along with proper ferulling, with other relevent jobs to complete the work in proper way as per UPPTCL Norms: -
132KV Bay Control Cable including cost of cable glands, lugs & ferrules complete and both end as per site and panel requirement
Erection of Lattice type main and auxiliary structures
Providing and Laying of Earth-mat with 40mm MS Rod after digging pit of 750mm depth accordance to the whole length of Earth-mat as per standard practice. (including digging pit and painting as per UPPTCL norms) [NOTE: - There should be atleast 7 meter span between parallel bars of cris-cross (squire shape) base in 132KV Side while 4 meter span of parallel bars of cris-cross (squire shape) base in 33KV side. Proper solid and smooth welding of Bars on joints (There should be overlapping of at least 150mm at joints) and crossings. There should be vertical bar of 03 meter length on outer bars with the gap of 14 meter in 132KV side while it should be with the gap of 12 meter in the 33KV side.]
Earthing of structures and equipments:
Providing, Laying and Earthing of 50mmx6mm MS flat for structures and equipments as per standard practice (including digging pit and painting as per UPPTCL
0.2 class accuracy ABT energy meters (Main + Check) including cable laying of CT and PT along with terminations of cables at both ends in a proper way.
Stringing of following Bus with specified ACSR conductors, tension fittings, suspension fittings & PG clamps to complete the work satisfactory as per technical specification (including cost of hoisting insulators, cutting of conductors and shifting of materials from store to site):
132KV Main Bus with Double ACSR Moose conductor.
132KV Transfer Bus with ACSR Moose conductor
132KV Jack Bus for 132KV Khajurhat Bay with ACSR Panther Conductor
Bay wise interconnection (jumpering) of equipments with specified conductors and Clamps along with Spacers:
132KV Khajurhat bay including Line side jumpering
PART - B - Supply Supply of various Items required for erection of structures and equipments and stringing work along with earthing of the equipment and structures for extension of 132KV Main and Transfer Bus along with construction of 132KV Khajurhat TSS Bay at 132KV S/S, Bikapur
132KV Bolted type Tension fitting for Single ACSR Panther Conductor suitable for Porcelain Disc Insulator with hardware set as per technical specification.
132KV Bolted type Suspension fitting for Single ACSR Panther Conductor Suitable for Porcelain Disc with hardware set as per technical specification.
132KV Bolted type Tension fitting for Single ACSR Moose Conductor suitable for Porcelain Disc Insulator with hardware set as per technical specification.
4 Bolted Type PG Clamp suitable for ACSR Moose to ACSR Moose Conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG Clamp suitable for ACSR Moose to ACSR Panther Conductor Complete with HDG nut bolt & washer as per technical specification.
3 Bolted Type PG Clamp suitable for ACSR Panther to ACSR Panther Conductor Complete with HDG nut bolt & washer as per technical specification.
Spacer for Twin ACSR Moose with 250mm space
Bus Post Clamp suitable for Twin Panther conductor complete with hot dip galvanized nut, bolts & washer as per technical specification.
132KV Isolator Clamp for Twin ACSR Moose conductor with nut, bolts and washer as per technical specification.
132KV Isolator Clamp for Twin ACSR Panther conductor with nut, bolts and washer as per technical specification.
132KV Breaker Clamp for Twin ACSR Panther conductor with nut, bolts and washer as per technical specification.
132KV CT Clamp for Twin ACSR Panther conductor with nut, bolts and washer as per technical specification.
132KV PT Clamp for Twin ACSR Moose conductor with nut, bolts and washer as per technical specification.
132KV PT Clamp for Twin ACSR Panther conductor with nut, bolts and washer as per technical specification.
120KV LA Clamp for Twin ACSR Panther conductor with nut, bolts and washer as per technical specification.
MAYA DEVI CONSTRUCTION
M/S JAI SHREE ENTERPRISES
Gupta Elect and Engg Works
Meena Elect & Engg. Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .