Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC HOUSE NO 138 B HILL VIEW LANE NO 03 INDRA NAGAR SRINAGAR 190004 J K | SRINAGAR | JAMMU AND KASHMIR | 190004 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹21.5 L+₹39,283 (1.86%)Rejected-Finance BANPURA BATWARA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹22.0 L+₹85,895 (4.06%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹45,500
Closing Date
12 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS PIN-914133 C/o 56 APO
CONSTR OF WEIGH BRIDGE AT 221 COY ASC SUP TYPE G SRINAGAR BB CANTT UNDER GE 864 EWS
2021_MES_442523_1
CWEK-22/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 864 EWS
Class E Category a i
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹45,500
Yes
HQ 133 WORKS ENGRS
20 Aug 2021
13 May 2021
14 Jun 2021
13 May 2021
12 Jun 2021
29 May 2021
13 May 2021 - 20 May 2021
22 May 2021
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas not exceeding 1.5 metre deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in soft/loose soil, complete all as specified and as directed .
Excavating in trenches, not exceeding 1.50 metre wide and exceeding 1.50m not exceeding 3.00m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and getting out in soft/loose soil, complete all as specified and as directed .
Returning filling in soil including spreding leveling watering and well ramming in layers not exceeding 25 cm each, complete all as specified and as directed .
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at level not exceeding 1.5 above the starting points, complete all as specified and as directed .
Material and labour for broken stone hard core of gauge not.exceeding 63mm, deposited, spread and leveled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material and labour for reinforced cement concrete (design mix) M-25 (using 20mm graded mechanically crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roof, landings, balconies, deck slabs, and the like, complete all as specified and as directed.
Material and labour for reinforced cement concrete (design mix) M-25 (using 20mm graded mechanically crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, basement slabs, under reamed piles, bases for columns and mass concrete complete all as specified and as directed.
Material and labour for reinforced cement concrete (design mix) M-25 (using 20mm graded mechanically crushed stone aggregate) in beams, cantilevers, lintels over 1.50m span, complete all as specified and directed.
Material and labour for reinforced cement concrete (design mix) M-25 (using 20mm graded mechanically crushed stone aggregate) as in columns, pillars, posts, etc. complete all as specified and as directed
Material and labour for reinforced cement concrete (design mix) M-25 (using 20mm graded mechanically crushed stone aggregate) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness, above top of footing; including attached pilasters and buttresses complete all as specified and as directed.
Use and waste of formwork to sides and soffits of roof beams, cantilever, bressummers ,lintels , shelves including supports and similar work for rough finished flat surfaces of concrete, complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slab, floor slab and similar work not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces of concrete, complete all as specified and as directed.
Form work to edges of RCC roof slab, floor slab and similar work exceeding 100mm but not exceeding 200mm thick for rough finished surfaces of concrete , complete all as specified and as directed .
Use and waste of form work to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of form work to sides of columns, pillars, posts, struts, piers and stanchions, etc. for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttrresses etc vertical or to batter, complete all as specified and as directed.
Supplying & Fixing for Pre-painted galvalume aluminuim zinc coating GI based corrugated steel sheet 0.50mm thick, conforming to IS-15961 of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws, complete, all as specified and as directed .
Material and labour for brick work with subclass ‘B` old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified and as directed.
Moorum filling under floor including spreading, levelling, watering and well ramming in layers not exceeding 15 cm thick complete all as specified and as directed.
Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed.
Supply and fixing for aluminium alloy anodized (powder-coated) door frame and shutters with hollow aluminium anodized sections as specified including aluminium alloy anodized snap type beads, dish type door handles, glazed clip joint cleats, rubber gasket, dead lock 4 levers, two numbers of aluminium alloy anodized tower bolts to each leaf etc. including fixing frame to wall/RCC members with rawl plugs complete. Sections of doors shall be aluminium hollow sections as follows: - (a) Door Frame single groove 101.6mmx44.45mmx2.15mm thick (b) Shutter top 47.62mmx44.45mmx1.95mm thick. (c) Shutter bottom 114.30mmx44.45mmx2.15mm thick (d) Shutter vertical 85mmx44.45mmx1.80mm thick (e) Shutter middle 83.5mmx44.45mmx2.40mm thick (f) Gauging clip weighing not less than 0.097kg/metre (g) 5.5mm thick tinted glass . (Note : 1. The rates shall be inclusive of provision of and fixing of rubber packing/gasket and tinted Glass )
Supply and fixing for aluminium alloy anodized (powder-coated) window frame with double shutters open able type, with aluminium sections as per of “Jindal” section numbers for casement windows with double shutters including aluminium alloy anodized snap type beads, handles, aluminium anodized barrel tower bolts and glazing clip, joint cleats, rubber gaskets etc., complete all as specified for series-B “ Jindal” section numbers for casement (a)Frame of section 101.6mmx44.45mmx2.10mm thick and section for shutter 47.62x44.45x1.95 mm thick (b) Mullion 53mmx52mmx 2mm thick not less than 1.065 kg/mtr. (c) Glazing clip weighing 0.259kg/mtr. (d) Windows shall be provided with 02 Nos. of tower bolt for single leaf and 03 Nos. of tower bolts for double leaf. Tower bolts shall be aluminium alloy anodized weighing 0.302kg/mtr. Handles shall be aluminium anodized ‘D’ type handle of size 98mm and thickness 2.37mm weighing 0.875kg/mtr and one no per each open able leaf shall be provided. (g) 4.00mm thick tinted glass . (Note : 1. The rates shall be inclusive of provision of and fixing of rubber packing/gasket and tinted Glass )
Supply and fixing roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (web, tee, angle, channel or flat sections) including distance pieces, cleats etc fixed in position,conforming to Fe-410(Gde 250), complete all as specified and as directed.
Supply and fixing mild steel, rolled sections(channel, angle or tee sections) fixed independently cut to ordinary length as in post or struts in fencing,ladder etc. including cutting tops to shape as required , drilling holes, notching for wire etc. including flat iron fillets with nuts and bolts for securing chain link fencing including all necessary drilling, bolting or riveting etc conforming to Fe-410(Gde 250), complete all as specified and as directed.
Material and Labour for TMT steel bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete, all as specified and as directed.
Material and Labour for TMT steel bars, 8mm dia and over , cut to length, bent to shape required including cranking, binding spirally for hooping or column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as in stirrups, spacer, binders, etc complete all as specified and directed.
Supply and fixing aluminium (Die cast) body door closer, hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 60 to 80 kg complete all as specified and as directed.
Material and labour for 18mm thick granite (of any type) work (table rubbed and polished and moulding) in platforms, steps, jambs, pillar, dado/skirting, floor over and including 20mm thick in cement mortar (1:3) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite, complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate), 50mm thick over and including 75mm thick PCC 1:3:6 type C-1, as in plinth protection/PCC path and paving, laid in panels of area not exceeding 2.00 sqm with 6mm wide joints filled with mastic (using bitumen and sand mixture applied hot in the ratio of 1:3 by weight) formed at the end of each panel and change in direction of plinth protection/PCC Path and paving and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as levelling course, finished even and fair to receive floor finishes, complete all as specified and directed.
Material and labour for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in sub base to floor, complete all as specified and as directed
Material and labour for 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate) as in sub base to floor/ hard standing, complete all as specified.
Material and Labour for Premium quality, vitrified ceramic tiles, Dark shade (Square/rectangular) , area of each tiles exceeding 0.18 sqm and not exceeding 0.36 sqm 8-10 mm thick as in floor over and including cement screed bed 15mm thick in cement mortar (1:4) base set and jointed in neat cement slurry @ 3.00 kg/Square metre and pointed in white or coloured cement to match the surface complete, all as specified and as directed.
Material and labour for Premium quality, vitrified ceramic tiles of same description and length as of floor tile but 150 mm height on vertical surfaces of walls including 10mm thick rough finished plaster in cement mortar (1:3) set jointed in neat cement slurry and pointed in coloured cement to match ,complete all as specified and as directed.
Material and labour for 10mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and Labour for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with WPC @2% by weight of cement or as per manufacturer’s instructions, finished even and fair, complete all as specified and as directed. (Note : WPC shall be measured and paid separately)
Supply only integral water proofing compound, complete all as specified and as directed.
Material and labour for 20mm thick boarding, hardwood IInd class, planed one side with butt joints, fixed with nails in any situation (except flooring and skirting) complete all as specified and as directed.
Material and labour for 6mm thick (5 ply) plywood, commercial type, grade BWR, type BB, fixed with nails to timber frame work in ceiling complete all as specified and as directed.
Material and labour for 2nd class hardwood clean sawn in scantlings, in any position in framed work, complete all as specified and directed
Material and labour for prepration of new plastered surface and applying two coats of oil bound distemper with hand roller, over a coat of primer complete all as specified and as directed.
Material and labour for two coat of cement base paint over a coat of alkaline resistant primer on newly plastered surface including preparation of surface of wall complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth, complete all as specified and as directed.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke (FRLS) , 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 19 mm dia with accessories, concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke (FRLS) , 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan any type/bell point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately .
Description all as per Srl item No.46 here in before but for socket outlet point 5 Amp on same board.
Description all as per Srl item No.46 here in before but for socket outlet point 5 Amp on Independent board complete, all as specified and as directed.
All as per the description of Serial Item No 46 above, but with 2.50 Sq mm un-sheathed multistranded cable for one socket outlet 15 Amps independent including continuous copper earth wire, PVC insulated of 2.50 Sq mm size complete, all as specified and as directed .
Supply and fixing switch piano 5/6 Amps, flush type, single pole, one way, 240 volt , AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing switch piano 15/16 Amps, flush type one way 240 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing socket outlet 5 pin 5/6 amps, 240 volt. flush type, AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing socket outlet 2 in 1, 6 pin 6 /16 Amp and multi pin flush type, 240 volt, AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing blanking plate, ISI Marked, complete all as specified and as directed.
Supply and fixing the ceiling rose, three terminal ISI marked surface backlit, complete all as specified and as directed.
Supply and fixing LED Security light luminaire 25 watt LED, ENDURA CITYLINER PLATINIUM, pressure die- cast aluminium housing, heat resistant glass, IP 66 protection with minimum 30 Nos of LEDs luminaire incl lamp (25 watt LED) complete with all accessories internally pre wired and including connecting with 3 core copper conductor flexible cable from terminal box to the ceiling rose or connector of the light point, complete all as specified and as directed.
Supply and fixing indoor decorative 18/20 watt LED tube light luminarie, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver , AC 220-240 Volts, 50Hz including lamp ( Lamp type LED tube light 1x 18/20 Watt) and connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete, all as specified and as directed.
Supply and fixing bracket for security light made up of 1.50m long GI pipe, 32mm dia, light grade, bent at required length to an angle of 120 degree and fixed to wall with two clamps made of 20x 3 mm mild steel flat iron 15cm long, 4 Nos 8mm dia bolts with nuts complete all as specified and as directed.
Supply and fixing MCB ( made from moulded self-extinguishing thermostat plastic) single pole, 240 volts, 50Hz , breaking capacity 10KA, C curve, 6 to 32 Amps, ISI marked, complete all as specified and as directed.
Supply and fixing MCB ( made from moulded self-extinguishing thermostat plastic) single pole neutral , 240 volts, 50Hz , breaking capacity 10KA, C curve, 32Amps, ISI marked complete all as specified and as directed.
Supply , insatallation, testing of SPN distibution board 08 way,double door , IP 43 , as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles, concealed on the wall surface, complete, all as specified and as directed.
Earthing complete with galvanised earth plate electrode 600mm x 600mmx 6mm thick buried directly in ground vertically ( earth pit of depth not less than 2.25m below ground level ) with top edge of the earth plate not less than 1.5m below normal ground level, connecting with 4.00 mm galvanized steel wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron and earth wire protected by galvanized steel pipe 15mm dia (light grade) including provn of concrete pit in PCC 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate), 40mm thick RCC cover slab 1:2:4 tpye B1 reinforced with XPM ( weight not less than 4kg/sqm ) and frame made of angle iron of section 40x40x6mm with lugs, 02 Nos handle of 6mm dia mild steel bar made to shape, 20mm dia GI pipe (light grade) for watering perforated at bottom 1.75m long placed on top edge of earth plate, charcoal and salt filling in alternate layer, test point made out of phopsphorus/ Bronze with fixing arrangement , funnel wire mesh and earth work in soft/loose soil, returning filling, removal of surplus soil all as shown in electrical plate No.3 of SSR Part-I and connection to earth test point complete, all as specified including testing on completion. Note : Item of earthing include cost of 7.5m long GI earth wire 4mm dia, ,earth work in soft/ loose soil, returning filling and removal, GI protection pipe, GI watering pipe, funnel, wire wesh, RCC cover, etc .
Earthing complete with galvanised earth plate electrode 600mm x 600mmx 6mm thick buried directly in ground vertically ( earth pit of depth not less than 2.25m below ground level ) with top edge of the earth plate not less than 1.5m below normal ground level, connected to equipment by using GI strips of size 32x6mm as earthing lead by means of bolts,nuts,checknut and washers of galvanised iron protected by galvanized steel pipe 40mm dia (light grade) including provn of concrete pit in PCC 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate), 40mm thick RCC cover slab 1:2:4 tpye B1 reinforced with XPM ( weight not less than 4kg/sqm ) and frame made of angle iron of section 40x40x6mm with lugs, 02 Nos handle of 6mm dia mild steel bar made to shape, 20mm dia GI pipe (light grade) for watering perforated at bottom 1.75m long placed on top edge of earth plate, charcoal and salt filling in alternate layer, test point made out of phopsphorus/ Bronze with fixing arrangement , funnel wire mesh and earth work in soft/loose soil, returning filling, removal of surplus soil all as shown in electrical plate No.5 of SSR Part-I and connection to earth test point complete, all as specified including testing on completion. Note : Item of earthing include cost of 7.5m long GI earth strip 32x6mm, ,earth work in soft/ loose soil, returning filling and removal, GI protection pipe, GI watering pipe, funnel, wire wesh, RCC cover, etc .
Supply and laying in trenches XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 2.0 core, complete, all as specified and as directed.
Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in hard/dense soil, complete all as specified and as directed .
Material and Labour for Fine and dry sand cushioning for underground cable by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including tretching the cable, complete all as specified and as directed . Note - Punned thickness of sand layer shall be measured and paid to contractor.
Material and labour for sub class 'B' brick of standard size laid dry width wise across the cable in trenches for protection of cable complete all as specified.
Supplying and fixing light grade GI tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut bolt or passing under floor complete, all as specified and as directed.
Material and labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation, filling and mass concrete including finishing the exposed surface of concrete without using extra cement, complete all as specified and directed.
Supply, installation, commissioning and testing of fully electronics pit less type weigh bridge of size 9.00m x 3.00m and having weighing capacity upto 40 tonne suitable for truck/ tank, hopper weighing and tensile testing.The plateform Deck shall have fabricated side beam constructed from electroless nickle plate, protection IP -68 class, heat treated tool steel with cup and steel ball mounted mechanism for self storing and self centering and welded module made of RS joint and 10 mm thick MS plate with weld anti skid strips mounted on 6 Nos OIML standerd double ended shear beam type load cell of capacity 30 ton each, including of Calibar Microproccessor based Digital indicator with RS-232 port to weigh 30 to 40 Ton having least count of 5.00 kg with in built inteligent terminal with computer system and laser printer process to print store weigh data like address Tare Gross and Net Weigh along with list print data wise, vehicle wise, metatial wise and supplier details incl GI pipes for load cell wiring from platform to cabin 230 volt single phase supply and complete electric system suitable for in and incl battery 12 Volt of suitable Ah and battery juction box suitable to connected load cells as per manufacture instructions, complete all as specified and directed..Make of Battery: Exide/Amron A) The system should have following performance specification:- Excitation voltage: 10VDC, Maximum voltage: 15VDC, Nominal output: 2.0 mVA, Non linearity: less than or equal to 0.025% on FSO (full scale output), Hysterisis : less than or equal to 0.01% FSO, Non repeatability : less than or equal to 0.01% FSO,creep: less than or equal to 0.03% FSO, Safe overload : 150% , Ultimate overload of Rated O/p : 300%, Allowable side load :50%, Side load discrimination: 300:1, Temp compensated Range: (-) 10 - 60 degree ,Temp effect on output: 0.0015% on FSO.
B) The system should have following performance specification:- Excitation Voltage: 10VDC, Maximum 15VDC, Nominal output: 2.0 mVA, Non linearity: less than or equal to 0.025% on FSO (full scale output), Hysterisis : less than or equal to 0.01% FSO, Non repeatability : less than or equal to 0.01% FSO,creep: less than or equal to 0.03% FSO, Safe overload : 150% , Ultimate overload of Rated O/p : 300%, Allowable side load :50%, Side load discrimination: 300:1, Temp compensated Range: (-) 10 - 60 degree ,Temp effect on output: 0.0015% on FSO C)The system should have following technical specification:- Processor: 8051 Micro controller, Processor Clock: 18 Mhz, Power supply: SMPS power supply, Input Voltage: 90 to 270 Volts AC at 50 Hz, Protection (a) 2.5 fuse for input AC mains(b) Input line filter for EMI & RH suppression(c) Spike suppressor for input transient (d) Opto-isolation of signals and For high immunity from electrical noise, Power Consumption : 10 VA (approx), Converter resolution : Sigma Delta Type with 24 bit, Clock: 2MHz, Conversion Speed: 18 Sample per Second, Load cell excitation: 6V DC with current capacity to drive upto 8 load cells of 350 ohm input resistance, Input Signal: 1 Microvolt to 3 Microvolt per division of weight (Unit Weight) , Display: 6 Digit seven segment RED LED display of 25 mm height., Serial port: Isolated RS -232 serial port is provided for computer interfacing or driving remote display, Enviornment: Operating Temperature0 degree to 55 degree, Humidity upto 95% RH non condensing
D) The weigh bridge should has good side force and shock resistance.The full mounted hardware are provided with load cells and transient voltage protection is provided for protection agaist lightening and line voltage faults. Note: The quoted rates shall be inclusive of i) Expences for the verification and stamping from weight from state authrized weight & measurement deptt. ii) Operation training from the authorized rep of manufacturer for 2 persons. iii) Supervision for installation & commissioning at site by supervisor / Engineer of manufacturer. iv) GI pipe for load cells wiring from platform to cabin as per manufacturer instructions and necessary test weight at the time of installation/ testing of weigh bridge. v) Earthing and point wiring required shall be measured and paid for separately in the respective item
M/S SUHEEL CONSTRUCTIONS
NAJAR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .