Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-Finance | ₹37.3 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹39.1 LRejected-Finance 165 RATAN LAL STREET AONLA AONLA BAREILLY UTTAR PRADESH 243301 UDYAM UP 15 0029702 | BAREILLY | UTTAR PRADESH | 243301 | ₹39.1 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹39.5 LRejected-Finance 1010 NANDANPURA BABINA CANTT DIST JHANSI 284401 | BABINA CANTT | JHANSI | UTTAR PRADESH | 284401 | ₹39.5 L | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹41.6 LRejected-Finance NEW PUMP HOUSE ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | ₹41.6 L | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹42.2 LRejected-Finance 630 MAIN ROAD BABINA CANTT 284401 TESIL DISTT JHANSI UP | BABINA CANTT | JHANSI | UP | 284401 | ₹42.2 L | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | m/s gupta trading L1 | N K ENTERPRISES L4 | M/S Ritu Tandon L6 | DEVENDRA ENTERPRISES L7 | M/S M S Constructions L3 | RAVI TRADERS L2 | R.P ASSOCIATES L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Taking down ceiling fan fan of any sweep, removing blade, cleaning the fan completely of dust and dirt , greasing and cleaning blades and fan with cerosene oil and checking of aligment of shaft ,oiling and Re- hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook rubber pad, nut bolts and washers etc, complete all as specified and directed by Engr-in-Charge. Note:
(a) Rewinding of ceiling fan could not be done , u/s ceiling fan to be declared BER as per policy.
(b) Ball bearing should be paid separately. | 2,000 | Each Job | 25 ₹50,000 | 50 ₹1 L | 30 ₹60,000 | 40 ₹80,000 | 50 ₹1 L | 120 ₹2.4 L | 55 ₹1.1 L |
| 2.00 | Taking down carefully the Exhaust fans/wall mounted fans /Air circulating fans of any capacity/sweep after disconnecting the eletric supply from any site and opening fans for repairs/over houling including removing dust and greasing and cleaning blades and fan with cerosene oil and checking of aligment of shaft , oiling including re-assembling ,nut bolt checking and connecting/refixing of fans in its original position burn out fan shall be kept seprately for rewinding complete all as specified and directed.
Note: Rewinding and replacment of defective parts shall be measured and paid separately. | 300 | Each Job | 30 ₹9,000 | 50 ₹15,000 | 30 ₹9,000 | 40 ₹12,000 | 50 ₹15,000 | 100 ₹30,000 | 55 ₹16,500 |
| 3.00 | Material and labour for Rewinding of exhaust fan of size up to 250/300mm with suitable gauge copper winding wire (supper enamelled) including all insulating material after necessary heat varnishing testing etc. complete all as specified and directed.Note for item No 03 to 07.
(a) Repairing /rewinding of Exhaust fans/Aircirculatinf fans shall be carried out in AGE E/M yard babina in present of JE E/M.
(b) Contractor shall detail the staff to collect defective fans from concern JE E/M , check the fan after opening it, and intimate the defects in the fan to JE E/M before carrying out the repairs. (c) The bearing of fan should be of NBC/SKF make only. No other make will be accepted. (d) Contractor will be provided by sticker of each repairing fan with date and name of frmns. (e) Contractor shall est. workshop for repairs/winding work,rent and allied charges will be applied as per tender norms | 500 | Each Job | 200 ₹1 L | 475 ₹2.4 L | 550 ₹2.8 L | 300 ₹1.5 L | 600 ₹3 L | 900 ₹4.5 L | 400 ₹2 L |
| 4.00 | All as per Ser item No 03 above but exhaust fan of size up to 380/450mm complete all as specified and directed. | 180 | Each Job | 300 ₹54,000 | 600 ₹1.1 L | 600 ₹1.1 L | 600 ₹1.1 L | 700 ₹1.3 L | 1,150 ₹2.1 L | 450 ₹81,000 |
| 5.00 | All as per Ser item No 03 above but wall mounted fan of size up to 300 mm sweep complete all as specified and directed. | 20 | Each Job | 250 ₹5,000 | 250 ₹5,000 | 300 ₹6,000 | 400 ₹8,000 | 400 ₹8,000 | 600 ₹12,000 | 300 ₹6,000 |
| 6.00 | All as per Ser item No 03 above but wall mounted fan of size up to 450 mm sweep complete all as specified and directed. | 20 | Each Job | 300 ₹6,000 | 550 ₹11,000 | 550 ₹11,000 | 520 ₹10,400 | 520 ₹10,400 | 600 ₹12,000 | 350 ₹7,000 |
| 7.00 | All as per Ser item No 03 above but industrial air circulator fan of size up to 600mm sweep complete all as specified and directed. | 15 | Each Job | 500 ₹7,500 | 600 ₹9,000 | 650 ₹9,750 | 750 ₹11,250 | 1,100 ₹16,500 | 900 ₹13,500 | 600 ₹9,000 |
| 8.00 | M & L for painting of Ceiling fan complete, in situ with synthetic enamel paint by spraying including filling, cavties with filler one coat after cleaning all dust including MES Nos are entered in all ceiling in site only, complete all as specified and directed. | 1,000 | Each Job | 20 ₹20,000 | 5 ₹5,000 | 10 ₹10,000 | 10 ₹10,000 | 25 ₹25,000 | 40 ₹40,000 | 15 ₹15,000 |
| 9.00 | M & L for painting of Exhaust fan complete, in situ with synthetic enamel paint by spraying including filling, cavties with filler one coat after cleaning all dust including MES Nos are entered in all motars in site only, complete all as specified and directed. | 1,000 | Each Job | 20 ₹20,000 | 5 ₹5,000 | 10 ₹10,000 | 10 ₹10,000 | 25 ₹25,000 | 40 ₹40,000 | 15 ₹15,000 |
| 10.00Taking out and replacement of following accessories from ceiling fans taking down vide item No 01.00 here in before complete all as specified and directed. | ||||||||||
Updated dates
Tender Value
₹39.9 L
EMD Value
₹79,800
Closing Date
4 May 2026, 6:00 pmClosed
GE Babina
GE Babina PIN-284401
REPAIR /REPLACEMENT OF OLD UNSV CEILING FAN, EXHAUST FAN, AIR VENTILATOR AND CONNECTED ITEM AT BABINA CANTT UNDER GE BABINA.
2026_MES_759964_1
8485/E8
Open Tender
Electrical and Maintenance Works
270 days
GE Babina
As per tender documents
8 documents required · 8 mandatory
₹500
GE Babina
₹79,800
Yes
8 Jun 2026
10 Apr 2026
6 May 2026
10 Apr 2026
4 May 2026
27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Taking down ceiling fan fan of any sweep, removing blade, cleaning the fan completely of dust and dirt , greasing and cleaning blades and fan with cerosene oil and checking of aligment of shaft ,oiling and Re- hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook rubber pad, nut bolts and washers etc, complete all as specified and directed by Engr-in-Charge. Note:
(a) Rewinding of ceiling fan could not be done , u/s ceiling fan to be declared BER as per policy.
(b) Ball bearing should be paid separately. | - | Each Job | - | - | |
Taking down carefully the Exhaust fans/wall mounted fans /Air circulating fans of any capacity/sweep after disconnecting the eletric supply from any site and opening fans for repairs/over houling including removing dust and greasing and cleaning blades and fan with cerosene oil and checking of aligment of shaft , oiling including re-assembling ,nut bolt checking and connecting/refixing of fans in its original position burn out fan shall be kept seprately for rewinding complete all as specified and directed.
Note: Rewinding and replacment of defective parts shall be measured and paid separately. | - | Each Job | - | - | |
Material and labour for Rewinding of exhaust fan of size up to 250/300mm with suitable gauge copper winding wire (supper enamelled) including all insulating material after necessary heat varnishing testing etc. complete all as specified and directed.Note for item No 03 to 07.
(a) Repairing /rewinding of Exhaust fans/Aircirculatinf fans shall be carried out in AGE E/M yard babina in present of JE E/M.
(b) Contractor shall detail the staff to collect defective fans from concern JE E/M , check the fan after opening it, and intimate the defects in the fan to JE E/M before carrying out the repairs. (c) The bearing of fan should be of NBC/SKF make only. No other make will be accepted. (d) Contractor will be provided by sticker of each repairing fan with date and name of frmns. (e) Contractor shall est. workshop for repairs/winding work,rent and allied charges will be applied as per tender norms | - | Each Job | - | - | |
All as per Ser item No 03 above but exhaust fan of size up to 380/450mm complete all as specified and directed. | - | Each Job | - | - | |
All as per Ser item No 03 above but wall mounted fan of size up to 300 mm sweep complete all as specified and directed. | - | Each Job | - | - | |
All as per Ser item No 03 above but wall mounted fan of size up to 450 mm sweep complete all as specified and directed. | - | Each Job | - | - | |
All as per Ser item No 03 above but industrial air circulator fan of size up to 600mm sweep complete all as specified and directed. | - | Each Job | - | - | |
M & L for painting of Ceiling fan complete, in situ with synthetic enamel paint by spraying including filling, cavties with filler one coat after cleaning all dust including MES Nos are entered in all ceiling in site only, complete all as specified and directed. | - | Each Job | - | - | |
M & L for painting of Exhaust fan complete, in situ with synthetic enamel paint by spraying including filling, cavties with filler one coat after cleaning all dust including MES Nos are entered in all motars in site only, complete all as specified and directed. | - | Each Job | - | - | |
Taking out and replacement of following accessories from ceiling fans taking down vide item No 01.00 here in before complete all as specified and directed. | - | - | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
8485Tenderdoc.pdf
Tender Documents • 1.30 MB
BOQ_851241.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid