| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC | ₹15.1 L Quoted ₹15.6 L | L1 | Accepted-AOC Negotiated the Lowest rate Quoted tenderer accepted |
| 2 | L2₹15.9 LRejected-AOC | ₹15.9 L | L2 | Rejected-AOC Rate quoted Higher than L1 Bidder |
| 3 | L3₹16.2 LRejected-AOC | ₹16.2 L | L3 | Rejected-AOC Rate quoted Higher than L1 Bidder |
| Sl No | Description | Qty | Unit | ANNAI ELECTRICALS L3 | BHARATHI ENGINEERING AND ELECTRICAL CONTRACTORS L2 | KARTHIKEYAN ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End). | 54 | Pts | 2,814 ₹1.5 L | 2,750 ₹1.5 L | 2,686 ₹1.5 L |
| 2.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End. | 8 | Pts | 2,272 ₹18,176 | 2,229 ₹17,832 | 2,186 ₹17,488 |
| 3.00 | Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End. | 4 | Pts | 3,471 ₹13,884 | 3,405 ₹13,620 | 3,339 ₹13,356 |
| 4.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End) (For Street Light Point). | 5 | Pts | 3,072 ₹15,360 | 3,014 ₹15,070 | 2,955 ₹14,775 |
| 5.00 | Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. | 9 | Nos | 3,938 ₹35,442 | 3,863 ₹34,767 | 3,788 ₹34,092 |
| 6.00 | Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. | 6 | Nos | 1,784 ₹10,704 | 1,750 ₹10,500 | 1,716 ₹10,296 |
| 7.00 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. | 22 | Nos | 1,132 ₹24,904 | 1,110 ₹24,420 | 1,089 ₹23,958 |
| 8.00 | Supply and fixing of Twin Box type 4'20W LED fitting (Higher End) complete with TW round block on wall or ceiling with PVC unsheathed Copper leads from the terminals to the fittings with 2 Nos 20W LED tubes. | 22 | Nos | 1,473 ₹32,406 | 1,445 ₹31,790 | 1,417 ₹31,174 |
| 9.00 | Supply and fixing of 9 W LED lamp (Higher End) with Battern Holder. | 4 | Nos | 334 ₹1,336 | 328 ₹1,312 | 321 ₹1,284 |
| 10.00 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting. | 5 | Nos | 6,455 ₹32,275 | 6,332 ₹31,660 | 6,209 ₹31,045 |
Tender Value
₹15.1 L
EMD Value
₹15,100
Closing Date
4 Feb 2026, 3:00 pmClosed
Superintending Engineer
Office of Superintending Engineer PWD Buildings construction and maintenance circle Madurai
Providing internal and external electrification to the State Tax Office building at Kodaikanal in Dindigul District
2026_PWD_644493_1
46SE/Bldgs C and M Circle Madurai 2025-26-1 dated 13.01.2026
Open Tender
Electrical Works
90 days
Kodaikanal, Dindigul District
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹15,100
29 May 2026
20 Jan 2026
4 Feb 2026
20 Jan 2026
4 Feb 2026
20 Jan 2026
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End).
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End.
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End) (For Street Light Point).
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.
Supply and fixing of Twin Box type 4'20W LED fitting (Higher End) complete with TW round block on wall or ceiling with PVC unsheathed Copper leads from the terminals to the fittings with 2 Nos 20W LED tubes.
Supply and fixing of 9 W LED lamp (Higher End) with Battern Holder.
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting.
Supply and fixing of 300mm (12inch) sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
Supply and fixing of louvers shuters arrangements for 300mm (12inch) sweep (light duty) AC exhasut fan.
Supply and fixing of 375 mm (15") sweep (light duty) AC exhaust fan complete without provision of holes in the wall.
Supply and fixing of louvers shutters arrangements for 375 mm (15") sweep light duty AC Exhaust fan.
Supply and fixing of 2000W Room Heater converter (Havells/Eq) with necessary connection complete.
Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 3 nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) inflush with wall with connections. Higher End.
Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 32A DP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. [The MCB and metal enclosure should be of Higher End]
Supply and Fixing of AC/DC 76mm buzzer/call bell suitable for 230volts 50C/s single phase AC Supply on suitable TW round block with 1 module GI flush mounting box 1 module combined plastic cover plate and 1 module modular type bell push swtch with indicator complete.(Higher End)
Supply and fixing of 32A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. [The MCB and metal enclosure should be of Higher End]
Supply and fixing of 5 kVA Single Phase In & Single Phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1hour backup along with Powder coated MS Rack and interlink cables with following specifications: 1. Output Voltage Range : 208V/220V/230V/240V AC 2. Voltage THD (Linear Load) : ≤2% 3. Voltage THD (Non-Linear Load) : ≤4% 4. Current THD : < 10% 5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode
6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (AC mode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action 7. Waveform : Pure sinewave 8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - <4ms) 9. Efficiency : 85% to 92% 10. Noise Level : less than 50dBA @ 1meter (with fan speed control) 11. Warranty : Two years on Electronics & one year on battery. UPS and Battery make should be approved by the departmental officers before used on work.
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal door cover flush type fitted with busbars and neutral links with seperate 4 way provision for accomodating one No 4 pole incoming MCB and another seperate 4 way provision for accomodating one No 4 pole RCD (totally 8 ways in one segment) and seperate provision for sub incomers in 3 segments and seperate provision for single phase outgoing MCBs in 3 Segments (totally 12 Nos) with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush wall with Earth connection only i) 32A FP MCB-1 No ii) 32A DP RCBO with 30mA sensitivity except AC type-3 Nos, iii) 6 to 20A SP MCB-12 Nos.
Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 3 nos. 32A 3P MCB , 15 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and run of 2 of 1.5 sqmm PVC insulated SC unsheathed FRLS Cu.Conductor of 1100V Grade in rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour. (For UPS wiring)
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion.
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed portion.
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed portion.
Supply and Run of 4 of 10 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade on 7/20 GI wire for service connection mains.
Supply and Run of 4 of 10 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in 32mm dia GI pipe (class B ) suitably bent at both ends with necessary angle iron upright and end support for service connection mains.
Supply and laying of 3 ½ x 25 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.(For Genset)
Supply and clamping of 3 1/2 x 25 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
Supply and fixing of brass cable gland for 3 1/2 x 25 sq.mm PVC armoured LTUG cable, with earth connection.
Supply and providing cable end termination of 3 ½ x 25 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Earthing as per PWD standard with an earth electrode of 2Mtr Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps/ supports on wall/ floor/ground for earth connection.
Supply and fixing of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1No. neutral link, copper earth flat of size 1" x 1/4" with interconnection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63Amp 30MA Four Pole RCD/RCCB (HigherEnd) with suitable necessary connection with earth connection complete.
Supply and fixing of 3 Phase 63A aerial fuse unit for 3 Nos 63A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps.
Supply, Testing Commissioning and Handing over of 15 kVA Diesel Generator set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications of 0.8 P.F. Three phase 415V/ 420 volts, 50Hz, 1500 RPM CPCB Approved capacity developing 20.9 HP with acoustic enclosure water cooled clock wise rotating feed pump with 12KW/ 15KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and vibration fitting and accessories and standard control panel as detailed below including transporting & unloading charges. (A) Engine: Water cooled diesel engine suitable for Generator application conforming CPCBIV+ norms and IS standards with a shaft out put o 20.9 HP at 1500 RPM under NTP conditions.
The Engine shall comprise the following standard fitting flexible coupling fly wheel, air cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc. (B)12 Volt Electronic starting Equipment: Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length (C) Engine Instrument Panel / Mounted: Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechnical) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous at full load.
D)ALTERNATOR: 15kVA/12kW Capacity 0 brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to CPCB IV+ Norms. E) STANDARD CONTROL PANEL : The standard control panel (cubical) should be vermin proo and dust proof best quality sheet steel of 16 SWG CRCA MS sheet and floor mounted with suitable hinged glass doors and enamel painted. The panel should be microprocessor based complete with suitable Square/ Rectangular copper bus bars with internal connections and with necessary cables and other accessories and with tapings for the incoming supply from the alternator and for the outgoing supply to the load and incorporating Suitable MCCB and HRC fuses, Set of control fuses, etc. with following facilities. 1. UNDER / OVER LIMIT i. High coolant Temperature ii. Low lube oil pressure iii. Over speed iv. Start fail v. Emergency stop vi. Over load
2. FAULT INDICATIONS: i. LLOP - Low Lub. oil pressure ii. HWT - High water temperature iii. OL - Over load iv. E.STOP - Emergency stop v. DG - Gen set ON vi. LOAD - ON 3.Metering & Protective relaying: i) Multi function Digital panel meter with the functions of Ammeter , Voltmeter, Frequency Meter, Power factor meter, KW meter, KWHrI Meter .- INO 2) Current transformers of suitable ratio. - Set of 3Nos. 3 Earth fault relay - INo
Fuel tank can be easily removed for cleaning or any maintenance. G.Exhaust Gas Recirculation system arrangements as per CPCB IV+ norms as amended H.BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generaor set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment. l) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof Acoustic canopy conforming CPCBIV+ norms floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather condtions and compliance to IS standards.
Erection of acoustic enclosure suitable for 15KVA Diesel generator complete with all accessories as above and suitable supports etc. as approved by competent authority to suit updated CPCB norms. J) Erection of generator set with proper alignment over the existing foundation. K)Supply of manuals for operation & maintenance of DG set with warranty card etc. L) CEIG approval: Preparation of site plan physical layout, electrical line schematic Diagram 10 sets, getting drawing approval from CEIG preparation of complection report rectification report etc., arranging CEIG inspection and obtaining CEIG safety certificate, payment of CEIG inspection fees if necessary and preparation of one set of approval Drawing and copy of safety certificate in a neat frame work.
M)TESTING AND COMMISSIONING After the installation of DG set on its foundation, the DG set should be tested and commissioned with first charging of lubrication oil to its level, first charging of battery and run the set for eight hours on full load test complete. The Genset engine and alternator make should be approved by department officials before used on work.
ERECTION OF GENSET: Providing suitable concrete foundation with Plain cement concrete 1:2:4 using 20mm jelly for wearing coat including laying, compacting, finishing and curing etc., complete as per standard specifications as directed by the departmental officers suitable for 15kVA Genset and suitable for State tax office at Kodaikanal Site condition.
Supply and fixing of 63 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and run of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in existing Concealed PVC rigid pipe.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
formkodaisto.pdf
Tender Documents • 1.36 MB
BOQ_772344.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid