Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance OLD NO 5 NEW NO 7 LAKSHMI GARDENS 3RD FLOOR 4TH STREET RANGARAJAPURAM SRINAGAR COLONY SAIDAPET CHENNAI 600015 | CHENNAI | CHENNAI | TAMIL NADU | 600015 | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹12.7 L (11.3%)Admitted-Finance ERODE 638012 | ERODE | ERODE | TAMIL NADU | 638012 | ₹1.3 Cr+₹12.7 L (11.3%) | L2 | Admitted-Finance |
| 3 | L3₹1.3 Cr+₹15.7 L (13.9%)Admitted-Finance | ₹1.3 Cr+₹15.7 L (13.9%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Not meeting the Qualification Criteria. Hence, not qualified |
| Sl No | Description | Qty | Unit | CREATORS ENGINEERS AND INTERIORS PVT LTD L1 | ESVEE CONSTRUCTIONS L3 | P Subramani and Co L2 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORKS | ||||||
| 2.00 | Dismantling existing aluminum partition with door / door and refixing the same at different location as per the direction of the engineer in charge. The rate includes labour charge for additional alteration and repairs, replacing the damaged parts, altering the existing design etc., whereverrequired etc. | 92 | Sqm | 970 ₹89,240 | 1,500 ₹1,38,000 | 700 ₹64,400 Lowest |
| 3.00 | Demolishing cement concrete including disposal of material within 50m lead 1 : 3 : 6 or richer mix. | 39 | Cum | 1,900 ₹74,100 | 1,500 ₹58,500 Lowest | 2,700 ₹1,05,300 |
| 4.00 | Brick work with Fly ash concrete blocks of class designation M100 in foundation and plinth in Cement mortar 1:4(1cement :4 coarse sand / M sand) | 114 | Cum | 9,100 ₹10,37,400 | 8,500 ₹9,69,000 Lowest | 10,000 ₹11,40,000 |
| 5.00 | Add Extra for brick work with Fly ash concrete blocks in superstructure above plinth level up to floor V level | 114 | Cum | 400 ₹45,600 | 250 ₹28,500 | 100 ₹11,400 Lowest |
| 6.00 | Providing and applying cement based putty M/s Birla or equivalent of upto 2 mm thickness over plastered surface to prepare the surface even and smooth etc complete. | 590 | Sqm | 225 ₹1,32,750 | 150 ₹88,500 Lowest | 170 ₹1,00,300 |
| 7.00 | 12 mm cement plaster of mix : 1:4 (1 Cement : 4 Fine sand / coarse sand / M sand) | 590 | Sqm | 475 ₹2,80,250 | 425 ₹2,50,750 Lowest | 425 ₹2,50,750 Lowest |
| 8.00 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand / M sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1200x600 mm. | 526 | Sqm | 1,875 ₹9,86,250 | 1,575 ₹8,28,450 Lowest | 1,700 ₹8,94,200 |
| 9.00 | Add extra for providing spacers of 3mm thick for laying ceramic/vitrified tile flooring and grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout with cerafil (Epoxy germ proof joint grout) or equivalent mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Instead of ordinary pointing for the tile various size.
For tiles above 60x60cm. | 526 | Sqm | 350 ₹1,84,100 | 300 ₹1,57,800 | 175 ₹92,050 Lowest |
| 10.00 | Providing and laying polished Vitrified glossy wall tiles Pattern type of Kajaria make as approved by Engineer in charge of size 1200x800x10mm (Model-Travertino Gold- Dark shade) and 1200x800x10mm tk (Model- Avorio Ivory-Light shade) at Wash basin & Urinal wall tile and neatly laid over in cement mortar 1:3 (Cement 1, M-Sand 3 ) 20mm thick with self adhesive of Cerabond. | 13 | Sqm | 2,600 ₹33,800 | 1,750 ₹22,750 Lowest | 2,500 ₹32,500 |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
13 Dec 2023, 3:00 pmClosed
Executive Engineer (Civil)
Office of the Executive Engineer (Civil), Engineering unit, Administrative Building 3rd Floor, IIT Madras, Chennai-600036
Creation of Archive facility at Stilt floor in NAC I building Civil, Electrical,Precision AHU FCUs, CCTV, Fire Alarm etc
2023_IITM_175386_1
21/2023-24/Composite
Open Tender
Civil Works
Item Rate
120 days
IIT Madras, Chennai-36
As mentioned in the tender documents
2 documents required · 2 mandatory
₹0
₹2.2 L
Through Google Meet
21 Dec 2023
22 Nov 2023
14 Dec 2023
22 Nov 2023
13 Dec 2023
30 Nov 2023
22 Nov 2023 - 28 Nov 2023
28 Nov 2023
Amount
CIVIL WORKS
Dismantling existing aluminum partition with door / door and refixing the same at different location as per the direction of the engineer in charge. The rate includes labour charge for additional alteration and repairs, replacing the damaged parts, altering the existing design etc., whereverrequired etc.
Demolishing cement concrete including disposal of material within 50m lead 1 : 3 : 6 or richer mix.
Brick work with Fly ash concrete blocks of class designation M100 in foundation and plinth in Cement mortar 1:4(1cement :4 coarse sand / M sand)
Add Extra for brick work with Fly ash concrete blocks in superstructure above plinth level up to floor V level
Providing and applying cement based putty M/s Birla or equivalent of upto 2 mm thickness over plastered surface to prepare the surface even and smooth etc complete.
12 mm cement plaster of mix : 1:4 (1 Cement : 4 Fine sand / coarse sand / M sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand / M sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1200x600 mm.
Add extra for providing spacers of 3mm thick for laying ceramic/vitrified tile flooring and grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout with cerafil (Epoxy germ proof joint grout) or equivalent mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Instead of ordinary pointing for the tile various size. For tiles above 60x60cm.
Providing and laying polished Vitrified glossy wall tiles Pattern type of Kajaria make as approved by Engineer in charge of size 1200x800x10mm (Model-Travertino Gold- Dark shade) and 1200x800x10mm tk (Model- Avorio Ivory-Light shade) at Wash basin & Urinal wall tile and neatly laid over in cement mortar 1:3 (Cement 1, M-Sand 3 ) 20mm thick with self adhesive of Cerabond.
Providing and fixing 18mm thick mirror polished, machine cut Granite for kitchen platforms, vanity counters, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1 : 4 (1 cement : 4 coarse sand / M sand) Granite black. Area of each slab above 0.50 sqm
Extra for providing edge moulding to 18mm thick stone counters, vanities etc., including machine polishing to edge to give high glass finish etc., complete as per design approved by Engineer - in – charge Granite work
Providing and fixing ISI marked flush door shutters decorative type, core of block board construction with frame of First class hard wood and well matched commercial ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30mm thick including ISI marked Stainless steel butt hinges with necessary screws.(Shakthi / Kutty / Western India) Non decorative type.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Second class teak wood.
Polishing the wooden surface using approved quality & make French polish /varnish including wood filler, thinner, colour pigmnt etc., and such other required materials, Two or more coats to give an even shade. (Asian / Sheenlac or Equivalent). For Door / Window /wall panelling /Furniture table / Class Room table etc.
Providing centering shuttering and form work for RCC works for all applicable RCC items in this schedule using best quality of film coated plywood / MS Sheets centering and shuttering materials, for required heights and sizes in all floors and all levels including charges for demoulding agent, removal of form work etc complete at all levels.
Providing and laying in position of RCC of grade M35 Concrete for walls and floors, columns, beams and slabs excluding cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc complete at all levels as per the direction of Engineer in charge. (minimum cement content 380 kg/cum + fly ash as per IS 456).
Supplying cutting bending and fabricating and placing in position as directed steel (SAIL, TISCO or RINL) reinforcement for RCC works in all floors, using MS or High Strength Deformed bars/RTS and MS binding wire 18 gauge etc complete at all levels. Fe 500D grade
Interior painting: (two or more coats over a primer coat including complete scraping, other surface preparation like removal of loose paint residuals, damaged plastering, repairs to plaster, white cement based (JK / Birla) touch up putty / primer and making good the wall surface etc) Applying interior paint of approved colour, make, brand and product at the approved rate of surface coverage of painting as per Annexure A.1.3. The interior paint shall be applied over dry surface after complete scraping and removal of all loose or defective paint or powdery residue using mechanical methods with Zero dust vaccum technology followed with sealing the surface with a coat of approved interior primer before application of top coat of exterior paint. The contractor shall also carryout necessary surface preparation including removal of loose plastering, patch plastering, crack filling, micro-concreting, application of damp proof coating and making good the wall surface etc wherever required before applying primer coat. The contractor should ensure complete covering of floors using tarpaulin / plastic sheet while taking up the work. The work shall be executed as per the detailed specifications and special conditions mentioned in the Annexure 1. The rate quoted shall be inclusive of charges towards all labour, material, transport, scaffolding, safety arrangements, Personal Protective Equipments (PPE), tools and plants etc.
Interior painting: (One or more coats excluding complete scraping and primer but including other surface preparation like removal of loose paint residuals, damaged plastering, high pressure jet washing, repairs to plaster, white cement based (JK / Birla) touch up putty / primer and making good the wall surface etc). Applying interior paint of approved colour, make, brand and product at the approved rate of surface coverage of painting as per Annexure A.1.3. The interior paint shall be applied over dry surface after removal of all loose or defective paint or powdery residue using mechanical methods with Zero dust vaccum technology followed with High pressure Jet washing whereever required before application of top coat of interior paint. The contractor shall also carryout necessary surface preparation including removal of loose plastering, patch plastering, crack filling, micro-concreting, application of damp proof coating and making good the wall surface etc wherever required before applying top coat. The contractor should ensure complete covering of floors using tarpaulin / plastic sheet while taking up the work. The work shall be executed as per the detailed specifications and special conditions mentioned in the Annexure 1. The rate quoted shall be inclusive of charges towards all labour, material, transport, scaffolding, safety arrangements, Personal Protective Equipments (PPE), tools and plants etc.
Providing and fixing of glazing with insulated double glass (exterior with 12mm glass and interior face with 6mm glass with adequate gap) (Make : Saint-Gobain). Fixing the glass shall form part of the system cost. Spacer for Insulated glazing unit shall be aluminum extruded profile and finished with AC 25 grade electrolytic colour anodic coating of black colour conforming to IS 1868 and filled with dry desiccant. Primary sealant shall be Poly-isobutylene (PIB) and Secondary seal shall be structural silicon sealant of DC 995 (one part) or DC 983 (two parts) of Dow corning or approved equivalent. Make and thickness of Inner pane glass shall be the same make as outer pane glass of IGU/DGU. However all the glass panes are shall be heat strengthened and the protection of glass as specified shall be responsible of the Bidder/Processor. The rate inclusive of suitable supporting frame work for fixing the glazing with Alexa Aluminum profiles ( Make : Dormakaba) as per the manufacturer specifications.
Providing and Fixing colour anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS :733 and IS 1285, fixed with rawl plugs and scews or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / Stainless steel screws, all complete as per architectural drawings and the directions of Engineer - in- charge. (Glazing and panelling to be paid for separatelly) For fixed portion Anodised aluminium (anodised transport or colour anodized dyed to required shade according to IS 1868, Minimum andioc coating of grade AC 15)
For shutters -Providing and Fixing colour anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS :733 and IS 1285, fixed with rawl plugs and scews or with fixing clips, or with expansion hold fasterns including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / Stainless steel screws, all complete as per architectural drawings and the directions of Engineer - in- charge. (Glazing and panelling to be paid for separatelly) For Shutters Anodised aluminium (anodised transport or colour anodized dyed to required shade according to IS 1868, Minimum andioc coating of grade AC 15)
Providing and fixing of aluminum colour powder coated (20 micron) ornamental grill for window using 50x50mmx6mm size opening fixed on aluminum frame with heavy duty aluminum U channel with all-round of grill and the rate including labour and material. (the rate of frame will be paid seperately) (Alumnium grill weight shall not be less than 2.95Kg/ Sq).
Providing and fixing of glazing to door/ window/ ventilator shutter and partition etc with pvc neoprene gasket / wooden reapers / necessary adhesives etc complete as per the direction of engineer in charge (Saint Gobain / Modifloat). 5mm thick float glass.
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc for fixing required door fittings all complete as per direction of Engineer in charge .
Providing and fixing Salem stainless steel A ISI 304 (18/8) kitchen sink as per IS 13983(without drain board) with CI brackets and stainless steel plug 40mm including painting the fittings cutting and making good the walls wherever required 610x510mm bowl depth 200mm. (Diamond / Butterfly)
Providing and fixing of 20mm dia CP Brass Swan neck Tap in Metro / Equivalent approved make including necessary fittings etc. complete
Providing and fixing brass gate valve with CI wheel of approved quality (Screw ended) (Leader / Audco / Horizon) 32mm nominal bore.
Providing and fixing 32mm dia CPVC valve for CPVC pipe line including cutting and fixing and etc complete
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes / SWR pipe conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion Finolex/Prince/Supreme). Single socketed pipe 75mm diameter.
Removing of existing surplus earth, rubbish and garbage through the lorry / truck including loading, unloading and transporting to out side the IITM premises including approval from local authorities like municipality/corporation complete as per the direction of Engineer in charge. Necessary deduction for voids @ of 20% will be made from the actual measured volume of rubbish.
120Mins Fire Steel Door with Dorma Hardware (door of any size- double or single leaf): with vision panel and hardware items. Providing and fixing of Hollow metal fire rated doors as per BS 476 part- 22 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Door frame shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry ratio 1:2 necessary for fire doors on the clear masonry opening.
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc complete.
Providing and fixing of Brass Cylindrical Lock of Godrej make with necessary screws and bolts etc. complete.
Providing and fixing aluminum hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc complete( including removing charges) 25 mm dia. ( Heavy Type ).
Providing and fixing IS 3564 marked Aluminum die cast body tubular type universal hydraulic door closer hardwyn make (classic queen) or equivalent with necessary accessories and screws etc complete ( including removing charges)
Providing and fixing of Hydraulic floor Spring for doors with approved make and etc. complete including cutting neatly finishing of floors (Hardwyn / Everite)
Sub Head B - Electrical Works
Supplying and fixing following company made sheet steel, MCB distribution board, 240V or 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required. l :
2+8 way/10 way single phase and neutral (double door type).(I/C-32A2P MCB, o/p, 6-32A SP MCB -8 nos)-LDB
2+8 way/10 way single phase and neutral (double door type)(I/C-63A 2P MCB, o/p, 6-32A SP MCB -8 nos)-UDB
Supplying and fixing following company made sheet steel, MCB distribution board, 240V or 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required. l :
Incomer 125 amps, 16 KA rating, 4 Pole MCCB- 1 No. Outgoings 40 amps, 10 KA rating, 3 Pole MCB- 2 Nos. 63 amps, 10 KA rating, 3 Pole MCB- 2 Nos. 6-10 amps, 10 KA rating, SP MCB- 12 Nos. Dummy sheets for the rest of the ways
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface /recessed medium class PVC conduit as required (1.14)
2 runs of 1.5 sq.mm and 1 run of 1.5 sqmm cable.
2 runs of 2.5 sq.mm and 1 run of 2.5 sqmm cable.
2 runs of 4.0 sq.mm and 1 run of 4 sq.mm cable.
2 Runs of 16.0 sq.mm and 1 run of 6 sq.mm cable.
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Point wiring in PVC conduit, with modular type switch/regulator wiring for light point/ fan point/ exhaust fan point/ call bell point/ 6 amps switched socket with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI / PVC box, ceiling rose, round block and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by the engineer incharge.Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required and instructed by the engineer incharge.Group C
Supplying& Laying of 3.5c x 70 sq.mm PVC XLPE insulated alu. Conductor armored 1100V LTUG cable in a cable tray/wall with necessary clamps.cable identification on both side with aluminium cable tags.
Supplying& Laying of 3.5c x 50 sq.mmPVC XLPE insulated alu. Conductor armored 1100V LTUG cable in a cable tray/wall with necessary clamps.cable identification on both side with aluminium cable tags.
Supplying& Laying of 4c x 6.0 sq.mmPVC XLPE insulated copper Conductor armoured 1100V LTUG cable in a cable tray/wall with necessary clamps.cable identification on both side with aluminium cable tags.
Supplying and making end termination with brass compression gland and Aluminium/ copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5c x 70 sq.mm alumium
3.5c x 50 sq.mm aluminium
4c x 6.0 sq.mm copper
Supplying and fixing of following modular switch/ socket on a modular plate & G I /PVC switch box including connections as required
2x 5 Amps socket controlled by one 15 Amps.Switch + 5 amps. socket controlled by one 5 amps. switch
5 amps socket controlled by 5 amps switch
6/16 amps. socket controlled by 16 amps. one way switch.
Supplying, installation, testing and commissioning of pre wired following type of LED light fittings complete with all accessories and Tubes/CFL etc on wall/ceiling/false ceiling including connections with 1.5 sqmm FRLS PVC insulated single core copper conductor wires and earthing etc as required.The LED fittings will be supplied CDL/WW/NW as instructed by the Engineer in charge
Crompton MakeModel POLARIS NEO-I 600mm x 600mm 24W square panel light with 6500K or equivalent in List of Approved make
18W LED Surface mounting fitting complete set. Crompton make Model LCDSPLN-R-18CDL Square or Round or equivalent in List of Approved make
SITC of Flame proof light (crompton EXTN2LT8-16/20 <8-20-865-2) or equivalent in List of Approved make
Supplying and fixing of following size DLP PVC trunking with all accessories including lids end caps, flexible internal/external corners flat angles,Flat tee, joint cover wherever necessary with cable divider, required type of modular box etc as per the site requirements
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required. 150mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of Hot Dipped Galvanised Iron cable tray cover with 25mm on each side using 1.6mm thick (Galvanisation thickness not less than 50 microns) including G.I. bolts & nuts, etc.as required. 150mm width
SITC of 1200MM sweep super efficient BLDC ceiling fan with 3 leaf , 5 speed completely pre wired up to the terminal block complete including modular type 2 module 5 step regulator as required.The sample to be got approved before procurement.
SITC of Popup Box 8 with 2 sockets with switches/universal/HDMI/USB Module -MK
Supplying & fixing of 20A 1Φ MC Plug and Socket controlled by 20A DP MCB ( Socket and MCB in a separate enclosures with all connections, testing etc.)
Supplying & fixing of 20A 4P MCB with sheet sheet enclosure on wall with necessary connection and earth connection as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
DATA/VOICE
Supplying and drawing of UTP 4 pair CAT 6A LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. Single run of cable
Supplying, Erection in the existing concealed box / modular of single Port Shuttered Faceplate for/with CAT 6A I/O module with back box.The rate shall be include nessary accessories like screw, proper labelling with color code, etc ., as complete with all respects complying with relevant standard specification as mentioned in the Technical Specfication , as directed by the Engineer-in-charge.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 runs of cables
Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess or cutting the wall and making good the same in case of recessed conduit as required. 25mm
Supply, installation, testing and commissioning of Layer 2 managed switch with 24 ports (RJ-45) of make and model No. CISCO/C9200-24T-E complete with supply. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, rack mountable termination accessories like Pigtails/ LIUs/ Convertors/ Splicing equipment, Patch panel, Patch Cord, etc complete as per specifications and as required.
SITC of 16 channel NVR with storage capacity should store all cameras at 4.0 MP resolution for minimum 30 days backup @25 FPS as required.
Supply, installation, testing and commissioning of Layer 2 managed switch with 16 ports (RJ-45) ,POE as to support all cameras complete with supply. The switch shall have 1 GB port to communicate with other switches POE compliant ports, rack mountable other termination accessories like Pigtails/ LIUs/ Convertors/ Splicing equipment, Patch panel, Patch Cord etccomplete as per specifications and as required.
Supply and fixing of 6 U wall mount indoor rack front glass door with cam lock,PDU 6 x 5 amps and 1.5 meter feed cable and 3 pin top shelf 225mm fan 203V 90 cfm, cable manager, 1U pvc loops hardware packet of 20 assembled as required.
SITC of IP N/W colour bullet camera, 1/3'' CMOS sensor, 4.0 MP resolution, varifocal 3-10 mm lens ONVIF COMPLIENT complete on wall/ ceiling with all required mounting accessories as required.
SITC of IP N/W colour Fixed bullet/dome camera, 1/3'' CMOS sensor, 4.0 MP resolution,ONVIF COMPLIENT completeon wall/ ceiling with all required mounting accessories as required. .
Sub Head C - Provision of Precision AHUs and FCUs
CHILLED WATER PRECISION AIR HANDLING UNIT(PAHU)
SITC of PRECISION AIR HANDLING UNITS FOR ARCHIVE CENTRE. Chilled Water Type Units with EC Fan- Motors and with inbuilt Pressure Independent Valve. CRAC units should be with Electronically Commutated Fan- Motor drives and with Pressure Independent valve. The evaporator coil shall be constructed of rifled bore copper tubes and louvered aluminum fins, with the aluminum/ GI frame.The drip trays must be double angled for condensate flow and easily removable for cleaning. Units should be supplied with MS flanges for connecting chilled water pipes to the unit.Fans: Unit must be provided with direct drive backward curved fans each running with DC drive electronically communicated motors, the fans should be aligned and balance statically and dynamically. The fan speed must be controlled based on the room return air Temperatures and also must have automatic speed control without manual intervention. The fans can be one /two/ three no’s as per the manufacturer’s standard.Noise Level: 70 db from 1 MT of unit in free filed conditions. Humidity shall be achieved by using Immersed-electrode type humidifier by which steam shall be produced and the steam shall be distributed evenly into the bypass air-stream of the process cooling unit. The Humidifier operation should have periodic flushing cycle. The Humidifier should guarantee a perfect efficiency with low energy consumption and greater durability of components. The humidifier shall be fully serviceable with replaceable electrodes. Filtration level should be of 90% - 10 microns. Filter should be of HDPE media & washable type Electrical Panel Control cabinet to be provided with Type 2 enclosure, with grounding lug, combination magnetic starters with overload relays, circuit breakers and cover interlock, and fusible control circuit transformer. The controls shall be a microprocessor programmable logic controller. The controls shall have separate indication of operating modes (cooling, heating, humidifying and dehumidifying), alarm conditions (temperature high, loss of sensor, compressor HP & LP, wet floor, no air flow and low humidifier water). The display and indication shall be visible on the front without removing any external panels. Local and remote alarms will be triggered if an alarm condition is reached. Each unit must be provided with large screen GRAPHICAL DISPLAY and additionally the controller must have feature of DUAL SET POINT programming
Capacity: 10.0 TR, Dehumidfication CFM: 4500CFM with 25mm static PAHU
DOUBLE SKIN FAN COIL UNITS - DECORATIVE TYPE CEILING SUSPENDED -INSIDE CONDITIONED SPACE
SITC of double skin chilled water Fan Coil Unit. It is proposed to install these units ceiling suspended inside the conditioned area without false ceiling. Hence, aesthetics of the unit is of parmount importance. The unit shall be constructed out of sandwiched panels minimum 43 mm thick RPUF insulation, with thermal break profile.The outer sheet of the panel shall be 0.8mm thick and the inner sheet shall be 0.63mm thick. The unit shall be provided with a Aluminium powdercoated grille for both supply air and return air. RA Grille on the rear side. SA Grille shall be provided in the front side. (please refer enclosed sketch). The units shall be with blow through design, units complete with pre-filters, fan section with DIDW forward curved fan directly coupled to a single phase motor operable in 3 speeds, 3 row deep cooling coil & extended drain tray. Coil section shall be with suitable air vent and drain points.The coil section and drain tray sections shall be provided with sandwiched insulation.The unit shall be sized to accommodate the isolation valves as well as the control valve. The FCU shall be factory fitted with isolation valves (ball valve with strainer at inlet and without strainer at outlet), 2 Way Motorised Valve(On/Off type) motorised valve with spring return (Valve to close when the power supply is cut off), necessary interconnections etc., Price to include for Room Thermostat compatable for BMS integration (Bacnet over MSTP) with On/Off, Fan Speed and Temperature Control with a digital display & upto 15Rmt of interconnecting wiring between FCU and Thermostat in GI conduits. Price also to include upto 3Rmt of copper flexible multicore cable with plugtop for power.
1.0 TR, 400 CFM
1.5 TR, 600 CFM
SITC of Pre Insulated Chilled water piping inside buildings in welded construction with MS ERW pipes with factory made GI spiral pipe jacketed PUF insulation complete with all fittings, flanges, pressure testing as per specification. Pipes 150mm dia and below shall be C class as per IS1239.200 mm and above shall be as per IS3589 with wall thicness as specified. Cost to include necessary supports with PUF saddles.
65mm dia NB - jacket dia min 160mm
50mm dia NB - jacket dia min 150mm
40mm dia NB - jacket dia min 140mm
32mm dia NB - jacket dia min 125mm
25mm dia NB - jacket dia min 125mm
COPPER CHILLED WATER PIPING
SITC of Copper Soft / Hard drawn piping for smaller chilled water units (CSU, FCU, Hiwalls) with all fitting and insulated with class "O" tubular closed cell nitrile rubber 25mm thick insulation with factory made glass cloth backing. Thickness of the copper pipe shall be minimum 22G. Price to include necessary flare nuts, adaptors etc., Copper pipe routing shall be as per the attached tender layouts. 19.1mm dia
BUTTERFLY VALVE
SITC of wafer type Butterfly valves PN 10 rating with extended stem complete with companion flanges, nuts, bolts, nuts, etc. as per specification. Price to include for insulation thickness as per the connected chilled water piping and covered with 300 micron polythene sheet as vapour barrier and finished with 26G Aluminium cladding as per specification. Valves 200mm and larger shall be equipped with gear arrangement for operation. 65mm dia NB
BALL VALVE
SITC of ball valves complete with heavy duty PN 10 carbon steel body, stainless steel ball and shaft etc. Insulation thickness shall be as per the connected chilled water piping. 25mm dia NB
BALANCING VALVES
SITC of PN10 Rating Balancing valves complete with companion flanges, nuts, bolts, gaskets and probes for pressure measurement complete with pressure readout points etc., as per specification. Insulation shall be as per the connected chilled water piping and covered with 300 micron polythene sheet as vapour barrier and finished with 26G Aluminium cladding as per specification. 65mm dia NB
PRESSURE GAUGES
THERMOMETER WITH THERMOWELL
SITC of 100mm dial type thermometer with capillary type sensor. Price to include for suitable thermowell and fixing arrangement for the thermometer.
Supply of portable pressure gauge, 100mm dial to work with test points
CONDENSATE DRAIN PIPING
SITC of 10Kg/Sq.cm rating PVC piping complete with fittings, factory manufacctured supports (Hitech), etc. The pipe shall be insulated with 25mm thick closed cell elastomeric nitrile rubber insualtion, class "0".
CHILLED WATER PIPING CABLE TRAYS
Supply and laying of 18G GI Solid tray, powdercoated (colour as per Architect's requirement) 75mm height as specified to house chilled water piping and cable conduits in external and exposed areas inside the conditioned areas.
150mm wide, 75mm height with 24G GI cover
300mm wide, 75mm height with 24G GI cover
AIR DISTRIBUTION SYSTEM
SHEET METAL DUCTING - GI
RECTANGULAR DUCT
Supply, Fabrication, Erection, testing and Commissioning of Factory fabricated rectangular ducts(boxed up in factory) of approved makes using GI Sheets. The price shall include TDF flanges, turning vanes, supports Gripple supports shall be used. Cost includes sealant, neoprene gasket, hangers, access door etc. Only flanged joints are acceptable for ducts above 150 mm size. All transverse joints shall be sealed with silicon sealant. The joints shall be with least leak. The duct gauge construction shall be for 2" static as per SMACNA 3rd edition. The quoted ratre shall be inclusive of loading, transportation, unloding, shifting & conduciting the pressure test as per the techical spcification & drawing details. 20 G - GSS (1.00mm)
FLAT OVAL DUCT
Supply, fabrication, erection, testing and commissioning of factory fabricated GI flat Oval ducts. The price shall include associated coupling, bends, transformation pieces, collars, turning vanes( if any), ' GRIPPLE' supports/hanging system. All the duct joints shall be sealed with silicon sealant. The joints shall be with least leak. No additional payment will be made for insulating couplings,joints etc., The quoted rate shall be inclusive of loading, transportation, unloding, shifting & conduciting the pressure test as per the techical spcification & drawing details. 22 G - GSS
PAINTING OF DUCTS
Painting of Exposed ducts, VAV, Dampers, collar ducts, etc,. inside conditioned area with an external coat of primer and finished with 2 coats of enamel spray painting. (primer and one coat at factory and second coat at site - colour as approved by architect). Pricing to include cost of providing suitable measures to prevent the spray painting at site from spoiling other services or surfaces. Kindly note that these ducts would be exposed and the finishing shall be of the highest quality to achieve better aesthetics. GI Rectangular/Flat oval/Spiral ducts for Airconditioning and Ventilation ducts, Dampers, Collar ducts, etc,. with Zinc Chromate primer and two coats of enamel paint.
SITC of duct dampers (VCD) of opposed blades of aluminium aerofoil section housed in sturdy aluminium frame with PVC/nylon gears, lockable handle etc.,
Supply & Installation of Fusible link type Fire dampers fabricated out of 16 G GI complete with outer frame, damper blades, GI sleeves, fusible link and suitable flange for connecting to the duct. The damper shall be of atleast 2.0 hr fire rating. The price shall include fire sealant around the dampers after installation.
SITC of Square diffusers return air out of powder coated Extruded Al. Diffuser, using removable core type, outer size 595 x 595 (to suit 600x600 grid) and following neck sizes for grid false ceiling areas. Colour of diffuser shall be as advised by the Architect. Note: If the same is installed in Gypsum ceiling area the diffuser shall be provided by only neck size with frame as per OEM std. 300x300mm
SITC of Supply air Square diffusers out of powder coated Extruded Al. Diffuser, using removable core type, outer size 595x595 (to suit 600x600 grid) including matt black powdercoated aluminium collar damper for grid false ceiling areas. Rates shall be for the following neck sizes. Colour of diffuser shall be as advised by the Architect. Note: If the same is installed in Gypsum ceiling area the diffuser shall be provided by only neck size with frame as per OEM std. 300x300mm
THERMAL INSULATION
SITC of Thermal insulation of Rectangular/Flat oval/Circular supply air & return air ducts using closed cell Nitrile rubber (class "O") insulation with LOW VOC adhesive on surface of the duct and inner face of the insulation. Insulation shall be done internally inside the duct for Rectangular/Flat oval / circular ducts for ducts running exposed in the conditioned areas and for other closed areas insulation shall be done outside suface area of the ducts. The joints shall sealed with 48mm wide, 3mm thick self adehesive nitrile rubber tape. Insulation will be measured as the same area of the duct being insulated. No additional payment will be made for insulating flanges etc., The insulation thickness shall be as follows. 13mm thick insulation
ACOUSTIC INSULATION
SITC of Acoustic lining of Rectangular/Flat oval/Circular ducting with 10mm thick open cell nitrile rubber foam of 140 to 180 kg/cum density, thermal conductivity 0.050w/mk and class 1 rating. Inside surface for the ducts shall be covered with Low voc adhesive recommended by manufacturer and mechanically secured. Insulation will be measured as the same area of the duct being insulated.
Provision fo connecting the HVAC equipment with BMS System
Fire Alarm System
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.(DSR 2019/17.2.4)
Supplying, installation, testing & commissioning of addressable manual call point complete as required(DSR 2019/17.2.14)
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.(DSR 2019/17.2.15)
Supplying, installation, testing & commissioning of fault isolator complete with base as required.(DSR 2019/17.2.7)
Supplying, installation, testing & commissioning of addressable fire control module complete as required(DSR 2019/17.2.10)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required(DSR 2019/17.5.2)
P Subramani and Co
ESVEE CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .