Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.9 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC L1 | |
| 2 | L2₹99.9 L+₹12.7 L (14.6%)Rejected-Finance BASEMENT PLOT NO 17 4657 21 ANSARI ROAD CENTRAL DELHI NEW DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
15 Nov 2021, 6:00 pmClosed
CWE NO 2 DELHI CANTT
HQ CWE NO 2 DELHI CANTT-10
REPAIR / REPLACEMENT OF DEFECTIVE OLD ALUMINIUM VERTICAL BUS BAR (RISING MAIN) IN CERTAIN BLOCKS AT RESTRICTED AREA UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2021_MES_474675_2
CWE /BH-25/2021-22
Limited
Electrical and Maintenance Works
Item Rate
120 days
RESTRICTED AREA
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE EM BASE HOSPITAL DELHI CANTT
₹1.8 L
Yes
4 Dec 2021
1 Nov 2021
17 Nov 2021
1 Nov 2021
15 Nov 2021
9 Nov 2021
Amount
Supply, installation, testing and commissioning in replacement indoor type LT rising main (bus duct) casing made out of 1.5mm thick sheet metal hot dip galvanised steel and painted with RAL 7035 resins consisting of aluminium busbar of 800 Amp (3L + N + PE), 42 kA for 1 sec, sandwich type bus bar trunking the bus duct enclosure consists of 4 C-ribbed section bars bordered and riveted .The Bush duct quoted is 3P, with 100% Neutral and enclosure as integral earth in GI as standarad with IP 55 and type is multi layer polyster film in class F insulation. Operating voltage upto 1000V, impulse with stand voltage12kV. Entire Aluminium alloy treated with 5 galvanic process (copper plating+Tin plating) with each standard length of straight feeder shall not exceed 3 mtrs and each having 3 Nos outlet providing of plug outlet and coverand also fix with two take-off points at each floor, including provision of expansion joint, and re-fixing of all existing electrical connections/facilities. Rising main to be installed along wall of multistoried bldg at Block D, F , Canteen Block and AHU Block, with fixing materials complete as per size requirement all as specified and directed.
Supply, installation, testing and commissioning in replacement indoor type LT rising main (bus duct) casing made out of 1.5mm thick sheet metal hot dip galvanised steel and painted with RAL 7035 resins consisting of aluminium busbar of 1250 Amp (3L + N + PE), 75kA for 1 Sec, sandwich type bus bar trunking the bus duct enclosure consists of 4 C-ribbed section bars bordered and riveted .The Bush duct quoted is 3P,with 100% Neutral and enclosure as integral earthGI as standarad with IP 55 and type is multi layer polyster film in class F insulation. Operating voltage upto 1000V,impulse withstand 12kV.Entire Aluminium alloy treated with 5 galvanic process (copper plating+Tin plating) with each standard length of straight feeder shall not exceed 3 mtrs and each having 3 Nos outlet providing of plug outlet and coverand also fix with two take-off points at each floor, including provision of expansion joint, and re-fixing of all existing electrical connections/facilities. Rising main to be installed along wall of multistoried bldg at E Block with fixing materials complete as per size requirement all as specified and directed.
Supply and fixing in replacememt sheet metal enclousre made out of CRCA sheet fix on the end cover of vertical rising main 800A/1250A complete all as specified and directed. Make ;-Legrand Cat Part No-65283101P or equivalent to General Electric /Siemens
Supply and fixing in replacement Tap off box plug in type with 250Amp 4 pole MCCB,36kA including spreader links for connecting of cables lugs/thimbles complete all as specified and directed. Make- Legrand Cat part No-65285014PR1.+ 420249 or equivalent to General Electric /Siemens.
Supply and fixing in replacement Tap off box plug in type with 160Amp 4 pole MCCB,36kA including spreader links for connecting of cables lugs/thimbles complete all as specified and directed. Make-Legrand cat part No-65285013PR1 + 420097 or equivalent to General Electric /Siemens
Supply and fixing in replacement Tap off box plug in type with 400 Amp 4 pole MCCB,36kA including spreader links for connecting of cables lugs/thimbles complete all as specified and directed. Make-Legrand cat part No-65285016PR2 + 422007 or equivalent to General Electric /Siemens
Supply and fixing in replacement End feed unit in sheet metal enclousre made out of CRCA sheet fixing on rising main alongwith 800 Amp , four pole, 50 kA, MDO , ACB including connection from existing cable to ACB by using tap plan cable size upto 70 sqmm as per site requirement and all fixing materials complete all as specified and directed. Make-Legrand cat part No 028731 or equivalent to General Electric /Siemens
Supply and fixing in replacement End feed unit in sheet metal enclousre made out of CRCA sheet fixing on rising main alongwith 1250 Amp , four pole, 50 kA, MDO , ACB including connection from existing cable to ACB by using tap plan cable size upto 70 sqmm as per site requirement and all fixing materials complete all as specified and directed. Make-Legrand cat part No 028733 or equivalent to General Electric /Siemens
Supply and fixing in replacement vertical Elbow consisting of aluminium busbar of 800 Amp sandwich design rated capacity for 3 phase, 4 wire, 50Hz AC complete all as specified and directed. Make:-Legand Cat Part No 60280431PF or equivalent to General Electric /Siemens
Supply and fixing in replacement vertical Elbow consisting of aluminium busbar of 1250 Amp sandwich design rated capacity for 3 phase, 4 wire, 50Hz AC complete all as specified and directed. Make:-Legand Cat Part No 60280414PF+60280404PF or equivalent to General Electric /Siemens
Supply and fixing in replacement Flange end including Elbow consisting of aluminium busbar of 800 Amp sandwich design rated capacity for 3 phase, 4 wire, 50Hz AC complete all as specified and directed. Make:-Legand Cat Part No 60281401PF or equivalent to General Electric /Siemens
Supply and fixing in replacement Flange end consisting of aluminium busbar of 1250 Amp sandwich design rated capacity for 3 phase, 4 wire, 50Hz AC complete all as specified and directed. Make:-Legand Cat Part No 60281004PF or equivalent to General Electric /Siemens
Supply and fixing in replacement Flange end consisting of aluminium busbar of 800 Amp sandwich design rated capacity for 3 phase, 4 wire, 50Hz AC complete all as specified and directed. Make:-Legand Cat Part No 60281001 PF or equivalent to General Electric /Siemens
Supply and fixing in replacement Spring Hangers supporting for aluminium busbar of 800 to 1250 Amp sandwich design rated capacity for 3 phase, 4 wire, 50Hz AC complete all as specified and directed. Make:-Legand Cat Part No 65213711 or equivalent to General Electric /Siemens
Supply and fixing in replacement Suspension brackets supporting for aluminium busbar of 800 Amp sandwich design rated capacity for 3 phase, 4 wire, 50Hz AC complete all as specified and directed. Make:-Legand Cat Part No 65202001or equivalent to General Electric /Siemens
Material and labour in replacement PVC insulated unsheathed flexible multistrand fire retardant low smoke copper conductor 70 Sqmm cable Tap off box to LT panel drawn in and including metallic flexible conuit suitable size along wall or into existing cable tray in switch room with suitable lugs, thimbles, complete all as per site requirement as specified and all as directed.
Material and labour in replacement PVC insulated unsheathed flexible multistrand fire retardant low smoke copper conductor 50 Sqmm cable Tap off box to LT panel drawn in and including metallic flexible conuit suitable size along wall or into existing cable tray in switch room with suitable lugs, thimbles, complete all as per site requirement as specified and all as directed. Make- Finolex/Havells/polycab.
Note:- (i) All necessary T&P shall be arranged by the contractor at his own cost. (ii) The entire work shall be executed on Saturday/Sunday/ holiday during day & night with written shutdown and prior permission of user only. The Contractor shall ensure to make the entire electric supply functional on each working day before 0600 hrs before leaving site of the cab sectt. (iii) Price of refixing existing earthing strip and all existing connection along with fixing materials shall deemed to be included in the quoted rates. (iv) Contractor must visit the site in each block (switch room) of multistory bldg and ascertain himself nature of the work before quoting the rates. (v) Drawings shall be provided by the contractor made from OEM and be submitted for approval prior to manufacting of the bus bar riser. (vi) At the time of installation of bus riser , engineer from OEM shall be present at site for guidance for proper installation, testing & commissioning. Cost of the same shall be included in the rate quoted by the tenderer. (vii) Contractor shall upload MOU/letter from OEM alongwith T Bid that the work shall be carried out by OEM/his authorised channel partner failing which financial bid of tender shall not be opened. (viii) After completion of work of each bus riser in each block (switch room), test cert shall be produced by the contractor from OEM before claiming RAR/FB. Cost of the same shall be included in the rate quoted by the tenderer.
VINAY ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .