Shri TKM Rambhal, EE
GE (W) Mathura Pin-281001
Comprehensive Maintenance Repair of cooling appliance like AC Cooler Refrigeration Deep freezer Water Cooler Under GE (West) Mathura
2020_MES_317328_2
8300/921/E8
Open Tender
Civil Works
Item Rate
335 days
Mathura Cantt
As per Tender Documents
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹42,000
Yes
17 Mar 2020
19 Feb 2020
9 Mar 2020
19 Feb 2020
7 Mar 2020
24 Feb 2020
Amount
M & L for servicing of split type AC of capacity 1.5 / 2 TR of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins and checking / testing of all parts for its serviceability, and oiling / greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant gas upto the required level, replacement of minor parts such as nut / bolt washers etc. and reassembling of complete unit including testing for smooth functioning complete all as specified and directed.
M & L for servicing of window type AC of capacity 1.5 / 2 TR of any type or make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking / testing of all parts for its serviceability, oiling / greasing to condenser cum blower fan motors, replacing worn-out rubber, bushes / rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant gas upto the required level, replacement of minor parts such as nut / bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified and directed. Note for item No 1&2 (i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Schedule. (ii) Any spare part of AC if found defective will be measured as supply and fix in repairs under respective item of this Schedule.
M & L for removing the condensing fan motor from window type AC of 1.5 / 2.0 TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts including testing for smooth function complete all as specified and directed.
Supply and fix in repairs wire remote control (Micro processor) unit suitable for split type AC 1.5 / 2 TR capacity of any make complete all as specified and directed.
T&P for shifting of Split type AC of any capacity from one site to another by completely removing it from the existing place wihout any damage,and shifting it to new site including gas charging to required level comissioning and testing it to complete all as specified and directed.
T&P for shifting of Window type AC of any capacity from one site to another by completely removing it from the existing place wihout any damage,and shifting it to new site making necessary cuttung in the wall making it good, including gas charging to reqd level comissioning and testing it to complete all as specified and directed.
Supply and fix in repair suction/discharge lines copper pipes of suitable size as necessary at site complete all as specified and directed.
Supply and fix in repair sleeve foam Protection Suitable for Split AC 1.5/2 TR as per site requirement complete all as specified and directed.
Supply and fix in repair 9 mm thick ply wood BWR type BB fixed for covering AC opening with second class hard wood lipping on edge and fixed to walls as required and directed including applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for in replacement submain wiring with single core PVC insulated FRLSH multistranded copper conductor cable of size 2x6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 25mm dia ISI marked ivory colour with all conduit fittings and fixing accessories for surface or concealed conduit as directed at site including chase cutting and 6.0 Sqmm FRLSH multistranded copper conductor cable as continuous earth wire including making good the disturbed surfaces complete all as specified and directed. Note :- Two run of 6 Sqmm cable and one run of 6 Sqmm earth cable and one run of 25mm PVC conduit shall be considered as a unit for measurements purpose.
M&L for in replacement submain wiring with single core PVC insulated FRLSH multistranded copper conductor cable of size 2x4.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories for surface or concealed conduit as directed at site including chase cutting and 4.0 Sqmm FRLSH multistranded copper conductor cable as continuous earth wire including making good the disturbed surfaces, complete all as specified and directed. Note :- Two run of 4 Sqmm cable and one run of 4 Sqmm earth cable and one run of 20mm PVC conduit shall be considered as a unit for measurements purpose.
M & L for removing the unserviceable condenser fan motor from split type AC of 1.5 / 2.0 TR capacity, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts complete including testing complete all as specified and directed.
Supply and fix in repair capacitor, 25 MFD as per existing size suitable for AC of capacity 1.5/2 TR complete all as specified and directed.
Supply and fix in repair capacitor, 36 MFD as per existing size suitable for AC of capacity 1.5/2 TR complete all as specified and directed.
Supply and fix in repair capacitor, 45/50 MFD as per existing size suitable for AC of capacity 1.5/2 TR complete all as specified and directed.
Supply and fix in repair capacitor, 10 MFD as per existing size suitable for blower motor of AC 1.5/2 TR cap complete all as specified and directed.
Supply and fix in repair capacitor, 4/6 MFD as per existing size suitable for blower motor of AC 1.5/2 TR cap complete all as specified and directed.
Supply and fix in repair drain out pipe of split type AC of PVC, heavy duty of 15 mm dia and 1.5 mm wall thickness complete with fittings, spacer and saddles complete all as specified and directed.
Supply and fix in repair aluminium fan blade size 375mm suitable for condenser of window type/split type AC of any capacity and complete all as specified and directed.
Supply and fix in repair PVC fan blade size 375mm suitable for condenser of window type AC of any capacity and acomplete all as specified and directed.
Supply and fix in repair PVC fan blade size 150mm suitable for blower of cooling side of window type AC of any capacity and complete all as specified and directed.
Supply and fix in repair realy only rating 15 Amp suitable for window type AC 1.5/2 TR complete all as specified and directed.
Supply and fix in repair over load protector only as per existing size suitable for window type AC 1.5 / 2.0 TR cap complete all as specified and directed.
M&L for removing the unserviceable reciprocating compressor sealed unit of any make or make from window type air conditioner of capacity 1.5TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with factory made reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filters etc jointing of copper refrigerant pipe line with and including charging of refrigerant gas to required level complete including cleaning of condenser fins, leakage testing etc complete all as specified and directed. Make: Hitachi /Voltas/Emersion
All as per item No 25.00(here-in-before) but for Window type Air Conditioner 2 TR capacity model CR-30.
All as per item No 25.00(here-in-before) but for Split type Air Conditioner 2 TR capacity.
All as per item No 25.00(here-in-before) but for Split type Air Conditioner 1.5 TR capacity.
M&L Removing the unserviceable Rotary compressor sealed unit of any type or make from window type air conditioner of capacity 1.5TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with factory made reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filters etc jointing of copper refrigerant pipe line with and including charging of refrigerant gas to required level complete including cleaning of condenser fins, leakage testing etc complete all as specified and directed. Make : Hitachi/LG/GMCC.
All as per item No 29.00(here-in-before) but for Window type Air Conditioner 2 TR capacity.
All as per item No 29.00(here-in-before) but for Split type Air Conditioner 1.5 TR capacity.
All as per item No 29.00(here-in-before) but for Split type Air Conditioner 2 TR capacity.
Supply and fix in repairs thermostat as per existing size suitable for window type AC 1.5 / 2 TR capacity complete all as specified and directed.
M & L for removing the unserviceable cooling fan motor of capacity 1/35 or 1/10 HP from split type AC, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush and side rubber ring and re-fixing in original position complete including testing complete all as specified and directed.
M&L for removing the unserviceable window/split Ac of any capacity and checking its leakage, brazing and completely arresting its leakage, gas charging and testing it to complete all as specified and directed.
S&F in repair cooling coil as per existing size suitable for window type AC of capacity 1.5/2 TR complete all as specified and directed.
S&F in repair PCB Plate Control card as per existing make or size suitable for 1.5/2TR capacity complete all as specified and directed.
S&F in repair Cooling coil motor as per existing size suitable for 1.5 TR/2 TR capacity complete all as specified and directed.
M&L for in replacement of unservicable wiring for elect Supply from indoor unit to outdoor unit of size 2.5 sqmm PVC insulated multistranded FRLS single core,3 run of 5 mtr for split AC 1.5/2 TR capacity of any type or make complete all as specified and directed.
M & L for cleaning down complete body including fitting and fixture of desert cooler of capacity 3000 to 6000 Cum / hours of any make including removal of all sludges, loose paint dust, dirt etc and prepared the clean surface for painting, and applying two coats of synthetic enamel paint inside top surface and out side surfaces and applying two coats rubber seal paint inside the water tank, including rewriting of MES No etc complete all as specified and directed.
M & L taking out unserviceable desert cooler fan motor single phase 230 Volts, 1400 RPM 3 speed 1 / 8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and fixing in existing position complete all as specified and directed.
Supply and fix in repairs front grill as per existing size to desert cooler made out of GI sheet suitable for 3000 to 6000 Cum / hrs capacity desert cooler of any make as approved by Engineer-in- Charge complete all as specified and directed.
Supply and fix in repairs PVC pipe 15 mm outer dia length 1.2m long with bends or elbow complete all as specified and directed.
Supply and fix in repairs wood pad (Set of three) as per existing shutter size,minimum weight 0.8 Kg, fixed in side panels desert coolers any cap any size complete all as specified and directed.
S&F in replacement of three speed desert cooler motor 60/ 100 turns, 1300/1400 RPM, Copper Winding single phase with ring, side legs, necessary bolts and nuts etc ISI Marked complete all as specified and directed.
Supply and fix in repair plug top three pin 5 Amps complete all as specified and directed.
Supply and fix in repair switch piano type 230 volts, singe pole one ways 6 Amps, fixed in desert coolers complete all as specified and directed.
Supply and fix in repairs PVC insulated round copper flexible three core of size .075 Sqmm including necessary arrangment for fixed on desert coolers switch complete all as specified and directed.
Supply and fix in repair capacitor 3/3.5 MFD dry type for fan motor of desert cooler complete all as specified and directed.
Supply and fix in repair oil filled capacitor 4 MFD for fan motor of desert cooler complete all as specified and directed.
Supply and fix in repair side shutter (Set of three) as per existing size made out from 1.00 mm thick galvanised iron sheet suitable for 3000/4000 Cum / hrs capacity desert cooler complete all as specified and directed.
Supply and fix in repair side shutter (Set of three)as per existing size made out from 1.00 mm thick galvanised iron sheet suitable for 5000/6000 Cum / hrs capacity desert cooler complete all as specified and directed.
Supply and fix in repair float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15 mm bore iron pipe, weight not less than 142 grams / each complete all as specified and directed.
Supply and fix in repairs of submersible pump 220 Volts, 0.025 HP suitable for desert cooler any size any cap & testing complete all as specified and directed.
Supply and fix in repairs aluminium fan blade balance type and fixing on shaft of motor suitable for desert cooler size up to 450mm sweep complete all as specified and directed.
Supply and fix in repairs cast iron ring of cooler fan motor with clamps suitable for desert cooler complete with nuts & bolts complete all as specified and directed.
Supply and fix in repairs PVC, 3 way distributor with nut/screw complete suitable for 15 mm PVC pipe including necessary arrangement complete all as specified and directed.
Supply and fix in repairs 15 mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock complete all as specified and directed.
Supply and fix in repairs water tank size 3000 to 6000 CFM suitable for desert cooler, fabricated with 1.6 mm thick mild steel galvanized iron sheet including gas welding at joint and testing for water tightness of apply one coat of red oxide primer complete all as specified and directed.
Supply and fix complete desert cooler body made out bottom with 1.6mm thick and top in 1.0mm thick with MS sheet complete with three set of side shutter complete all as specified and directed.
M&L for servicing of Water cooler of capacity 40/80 to 150/150 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor,electric connections etc incl checking of refrigerant standing pressure and topping of refrigerant gas upto the required level complete including testing for smooth functioning complete all as specified and directed.
M & L for preparation of old painted surface of 40/80 Ltr capacity water cooler, externally and internally including compressor chamber, motor and applying one coat of synthetic enamel paint with spray machine including writing MES No. etc. complete all as specified and directed.
All as per item No 63.00(here-in-before) but for capacity 60/120 Ltrs.
All as per item No 63.00(here-in-before) but for capacity 150/150 Ltrs.
M & L for removing the unserviceable condensing fan motor from water cooler of cap 40/80 ltrs capacity, rewinding the same with super enameled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed
All as per item No 66.00(here-in-before) but of capacity 60/120
All as per item No 66.00(here-in-before) but of capacity 150/150
S & F in repair aluminium fan blade size 125mm balance type suitable for water cooler of capacity 40/80 Litres complete all as specified and directed.
S & F in repair aluminium fan blade size 150mm balance type suitable for water cooler of capacity 60 / 120 Ltrs complete all as specified and directed.
S & F in repair aluminium fan blade size 225mm balance type suitable for water cooler of capacity 150/150 Litrs complete all as specified and directed.
Supply and fix in repairs 15 mm size bib tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs starting capacitor 60/80 MFD suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs running capacitor 10 MFD suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs thermostat range 2 degree celcius to 15 degree celcius suitable for water cooler of any capacity complete all as specified and directed.
Supply and fix in repairs waste water adaptor PVC, 32 mm size suitable for water cooler of any cpacity complete all as specified and directed.
Supply and fix in repairs relay with Over Load Protector rating 5 to 15 Amp suitable for 40 to 150 liters capacity water cooler complete all as specified and directed.
Supply and fix in repairs PVC drain out pipe, heavy duty 40 mm dia, wall thickness 2 mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacit complete all as specified and directed.
Supply & fix 15 mm bore mild steel galvanized water tubing, medium grade with all fitting and accessories complete fixed to walls and ceiling or laid to floors etc including taking down old GI tubing complete all as specified and directed.
M&L for removing the unserviceable compressor sealed unit of any type/any make from water cooler capacity 40 / 80 liters after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning complete all as specified and directed.Make:sidwal/Voltas/ Blue star. Note :- Gurantee certificate for 12 months from manufacturer shall be provided for claiming any payment.
All as per item No 80.00(here-in-before) but water cooler of capacity 60/120 Litres model No 444.
All as per item No 80.00(here-in-before) but water cooler of capacity 150 / 150 Litres model No 461.
M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including check gas in compressor and testing the water cooler for the entire satisfaction complete all as specified and directed.
All as per item No 83.00(here-in-before) but for water cooler of capacity storage/cooling 60/120 litres.
All as per item No 83.00(here-in-before) but for water cooler of storage/cooling capacity of 40/80 litres.
M&L for servicing of Refrigerator of capacity 100 to 310 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensing coil,door,freezer etc including checking of refrigerant standing pressure and topping up of refrigerant gas upto the required level complete including testing for smooth functioning complete all as specified and directed.
M & L for cutting and removing unserviceable freezer unit of refrigerator capacity 100 to 180 litres of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified and directed.
All as per item No 87.00(here-in-before) but refrigerator of capacity 210 to 290 ltrs
All as per item No 87.00(here-in-before) but refrigerator of capacity 300 / 310 litres
M & L for preparation of external old painted surface of refrigerator of capacity 100 to 310 litres of any make, including denting of minor patches and applying one coats of Duco paint with spray machine including polishing complete all as specified and directed.
Supply and fix in repairs thermostat range 2 degree celcius to 15 degree celcius as per existing size suitable for refrigerator 100 to 310 liters capacity complete all as specified and directed.
M&L for Removing the unserviceable compressor sealed unit of refrigerator of capacity 100 to 180 liters of any make, & replacing the same compressor with reconditioned compressor of same make of model complete, rein-stalling in original position with all accessories like relay with Over Load Protector, filter & recharging of refrigerant complete including guarentee certificate & testing for smooth functioning complete all as specified and directed. Make: LG/Godrej/ Whirlpool.
All as per item No 92.00(here-in-before) but refrigerator of capacity 210 to 310 litres
M&L for finding out the leakage with the pressure test of the condenser or cooling coil of Rerigerator of capacity 100 to 180 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler for the entire satisfaction complete all as specified and directed.
All as per item No 94.00(here-in-before) but refrigerator of capacity 210 to 310 litres
M&L for servicing of Deep freezer of capacity 120 to 405 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and topping up of refrigerant gas upto the required level complete including testing for smooth functioning complete all as specified and directed.
M&L for preparation of external old painted surface of Deep freezer of capacity 120 to 405 liters of any makes including denting of minor patches and applying one coat of Duco paint with spray machine complete all as specified and directed.
Removing the unserviceable compressor sealed unit of Deep freezer of capacity 120 liters of any make & replacing the same compressor with reconditioned compressor of the same make and model complete re-installing in original position withal accessories like relay with over load protector & recharging of refrigerant gas complete including testing for smooth functioning complete all as specified and directed.
All as per item No 98.00(here-in-before) but Deep freezer of capacity 200/205 liters
All as per item No 98.00(here-in-before) but Deep freezer of capacity 405 liters
S&F in repair condensing coil size 45 cmx 45cm, heating element 1500W suitable for window type AC of capacity 1.5 TR complete all as specified and directed.
S&F in repair condensing coil size 60 cmx 60cm, heating element 2000W suitable for window type AC of capacity 2.0 TR complete all as specified and directed.
Supply and Fix in repair metal clad box with top plug and socket with 32 A MCB SP complete all as specified and directed.Make- Havells/Legrand/HPL
Supply & refilling in refrigerant gas R-22/R-134 for charging the all cooling appliances as when as required at site as per direction by Engr in charge.
M&L for servicing (repairing/overhauling) of voltage stablizer single phase at site/EM yard, dismantling unserviceable parts/replacement of minor parts of circuit plate & 3 way connectors etc and re-assembling and testing etc for the following capacity complete all as specified and directed :- (a) 0.5 KVA
Supply and fixed in repair of relay suitable for voltage stabilizer for the following capacity complete all as specified and directed :- (a) 0.5 KVA
Supply and fixed in repair voltage stabilizer of Amp meter single Phase (0 to 30 Amp), complete all as specified and directed.
Supply and Fixed in repairs voltmeter single phase (0-300 V), complete all as specified and directed.
M&L for rewinding of transformer of voltage stablizer single phase for the following capacity complete all as specified and directed :- (a) 0.5 KVA
M&L for gas charging of ductable type pakage AC of capacity 8.5 ton incluiding necessary R-22/R-134 gas, filter, anti-moisturising agent, soldering, brazing necessary copper capillary tube any size and testing, complete all as specified and directed.
M&L for gas charging of ductable type pakage AC of capacity 11.0 ton incluiding necessary R-22/R-134 gas, filter, anti-moisturising agent, soldering, brazing necessary copper capillary tube any size and testing, complete all as specified and directed.
M&L for servicing of ductable pakage type AC of capacity 8.5/11 ton by cleaning of coil filter, condensor coil with high pressure air/water, oiling greasing of all moving parts, complete all as specified and directed.
Removing burnt/defective compressor unit of any make from any type of air conditioner of 8.5 ton capacity including gas charging & filter by cutting of suction and discharge lines and unscrewing foundation nuts and supply & fixing factory re-conditioned compressor unit, including guarentee certificate complete all as specified and directed. Make :- TECUMSEH/KIRLOSKAR/Blue star as per existing make and size including tightening the foundation nuts with new gourmets, connecting suction & discharge lines by gas welding work complete all as specified and directed.
Removing burnt/defective compressor unit of any make from any type of air conditioner of 11.0 ton capacity including gas charging & filter by cutting of suction and discharge lines and unscrewing foundation nuts and supply & fixing factory re-conditioned compressor unit, including guarentee certificate complete all as specified and directed. Make :-TECUMSEH/KIRLOSKAR/Blue star as per existing make and size including tightening the foundation nuts with new gourmets, connecting suction & discharge lines by gas welding work complete all as specified and directed.
S&F in repair for controller card suitable for 8.5 Ton ductable 3 Phase Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair controller card suitable for 11 Ton ductable 3 Phase Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/2 HP size 300mm sweep for indoor unit of 8.5 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/4 HP size 500mm sweep for outdoor unit of 8.5 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/2 HP size 400mm sweep for indoor unit of 11 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair fan motor capacity 1/4 HP size 600mm sweep for outdoor unit of 11 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair for 3 Phase preventer of AC of 11 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S&F in repair 3 Phase preventer of AC of 8.5 Ton ductable Air Conditioner as per existing make, size and capacity, complete all as specified and directed.
S & F in replacement of expansion valve as per existing size suitable for Ductable AC 8.5/11TR capacity complete all as specified and directed.
S&F PVC front grill for window type AC capacity 1.5/2.0 Ton of any make, any type complete all as specified and directed.
iswar enterprises
A.K. ENGINEERS
RAJ CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .