| 1.00 | Taking down aluminium point wring(light, fan, socket or power) including fittings and fixtures if any and making good distrubed surface of walls, floors, etc to match with the existing, surfacecomplete all as directed. | 1,555 | Per Point | 80 ₹1,24,400 | 25 ₹38,875 Lowest | 99 ₹1,53,945 | 107.92 ₹1,67,815.6 |
| 2.00 | M&L for light point wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and concealed type in PVC conduit in walls/roof including making necessary chases in walls and making good to match with exterior emultion paint for existing surface and including provision of modular metal GI flush boxes with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotr cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 5 amps one way modular switch for one light/bell point, complete all as specified and directed.
NOTE;- The cost of metal flush boxes, modular white cover plate deemed to include under respEctive items of this Schedule. | 550 | Per Point | 775 ₹4,26,250 | 550 ₹3,02,500 Lowest | 650 ₹3,57,500 | 702.9 ₹3,86,595 |
| 3.00 | All as per SI item No. 2 here-in-before but for one fan point controlled by one 5 Amps one-way modular | 50 | Per Point | 775 ₹38,750 | 575 ₹28,750 | 475 ₹23,750 Lowest | 511.2 ₹25,560 |
| 4.00 | All as per SI item No. 2 here-in-before but for one Exhaust fan point controlled by one 5 Amps one-way modular | 50 | Per Point | 775 ₹38,750 | 600 ₹30,000 | 476 ₹23,800 Lowest | 511.2 ₹25,560 |
| 5.00 | All as per SI Item No.2 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on same board. | 80 | Per Point | 350 ₹28,000 | 550 ₹44,000 | 102 ₹8,160 Lowest | 115.02 ₹9,201.6 |
| 6.00 | All as per SI Item No.2 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on independent board. | 350 | Per point | 775 ₹2,71,250 | 600 ₹2,10,000 | 477 ₹1,66,950 Lowest | 511.2 ₹1,78,920 |
| 7.00 | All as per SI item No. 2 here-in-before but for one Bell point controlled by one 5 Amps one-way modular | 10 | Per Point | 775 ₹7,750 | 600 ₹6,000 | 476 ₹4,760 Lowest | 511.2 ₹5,112 |
| 8.00 | All as per SI item No. 2 here-in-before but for One light point controlled by two 2-way switches | 5 | Per Point | 775 ₹3,875 | 600 ₹3,000 Lowest | 730 ₹3,650 | 715.68 ₹3,578.4 |
| 9.00 | All as per SI Item No.2 here-in-before but for 15 amps socket outle with 2.5 Sq.mm copper cable including 2.5 Sq.mm PVC insulated copper condutor cable as earth continuity conductor and connecting to earth dolly, complete all as specified and as directed. | 400 | Per point | 950 ₹3,80,000 | 640 ₹2,56,000 Lowest | 890 ₹3,56,000 | 923 ₹3,69,200 |
| 10.00 | All as per item No 2 above but with cable 4 sqmm for phase and neutral & 4.0 sqmm for earth continuity all as directed ( for 20 Amps socket ) . | 60 | Per Point | 1,250 ₹75,000 | 665 ₹39,900 Lowest | 1,100 ₹66,000 | 1,207 ₹72,420 |
Tender Value
₹47.0 L
EMD Value
₹93,980
Closing Date
21 Aug 2025, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIR REPLACEMENT MAINT OF INTERNAL ELECTRIFICATION INCLUDING REPAIRS OF CEILING FANS EXHAUST FAN PEDESTAL FAN WALL FAN ETC AND OTHER ALLIED WORKS AT RCI TECHNICAL AREA ZONE-II EETF AND ETC UNDER GE I RND RCI HYDERABAD
2025_MES_722267_1
8303
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE(I) R AND D RCI
MES enlisted Class D category b i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹93,980
Yes
30 Aug 2025
24 Jul 2025
23 Aug 2025
24 Jul 2025
21 Aug 2025
7 Aug 2025
Amount
Taking down aluminium point wring(light, fan, socket or power) including fittings and fixtures if any and making good distrubed surface of walls, floors, etc to match with the existing, surfacecomplete all as directed.
M&L for light point wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and concealed type in PVC conduit in walls/roof including making necessary chases in walls and making good to match with exterior emultion paint for existing surface and including provision of modular metal GI flush boxes with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotr cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 5 amps one way modular switch for one light/bell point, complete all as specified and directed. NOTE;- The cost of metal flush boxes, modular white cover plate deemed to include under respEctive items of this Schedule.
All as per SI item No. 2 here-in-before but for one fan point controlled by one 5 Amps one-way modular
All as per SI item No. 2 here-in-before but for one Exhaust fan point controlled by one 5 Amps one-way modular
All as per SI Item No.2 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on same board.
All as per SI Item No.2 here-in-before but for one 3 pin socket out let 6 amps modular socket controlled by one way switch on independent board.
All as per SI item No. 2 here-in-before but for one Bell point controlled by one 5 Amps one-way modular
All as per SI item No. 2 here-in-before but for One light point controlled by two 2-way switches
All as per SI Item No.2 here-in-before but for 15 amps socket outle with 2.5 Sq.mm copper cable including 2.5 Sq.mm PVC insulated copper condutor cable as earth continuity conductor and connecting to earth dolly, complete all as specified and as directed.
All as per item No 2 above but with cable 4 sqmm for phase and neutral & 4.0 sqmm for earth continuity all as directed ( for 20 Amps socket ) .
S&F Modular switch one way 6 Amp, one module 240V, single pole complete all as specified and as directed.
S&F Modular switch one way 16 Amp, one module 240V, single pole complete all as specified and as directed.
S&F Modular Socket, 6A - 2/3 pin combination 2 module, complete all as specified and as directed.
S&F Modular Socket, 6A/16A - 2/3 pin(5pin) combination 2 module, complete all as specified and as directed.
S&F in repair Modular switch two way 6 Amp, one module 240V, single pole complete all as specified and as directed.
S&F in replacement Bell push modular type, 5 Amps button all as specified and as directed.
S&F in replacement ceiling rose two to three terminal surface backelite type AC 50 HZ 230 Volt, Complete al as specified and as directed.
S&F in replacement Modular fan step regulator, 120W - 2 Module, complete all as specified and as directed.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20Amps with ‘C’ curve, 240 Volts complete all as specified and directed.
Supplying and fixing in replacement,3 Module (100mmX75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing in replacement, 6 Module (200mmX75mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing in replacement,8Module (125mmX125mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing in replacement,12Module (200mmX150mm) modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supply and fixing in re[lacement, Single pole and neutral Sheet metal enclosure 12 way double door for MCB’s, Phosphatised Powder Painted with Bus Bar 200 amp rated, 240 volt AC complete all as specified and directed.
Supply and fixing Single pole and neutral Sheet metal enclosure 8 way double door for MCB’s, Phosphatised Powder Painted with Bus Bar 200 amp rated, 240 volt AC complete all as specified and directed.
S&F in replacement, sheet metal enclosure for pre wired distribution board double door, powder coated VTPN 6 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link complete all as specified and directed.
S&F in replacement, sheet metal enclosure for pre wired distribution board double door, powder coated VTPN, 4 way with out MCCB, three phase 415 volt with 100 Amps rated tinned electrolytic copper bus bar with neutral link complete.
S&F in replacement, sheet metal enclosure for pre wired distribution board double door, powder coated TPN, 4 way with out MCB, three phase 415 volt with 100 Amps rated tinned electrolytic copper bus bar with neutral link complete.
S&F in replacement,Ajustable thermal & magnetic release MCCB TP 200 Amps capacity 36 KA 415 Volts 50 HZ complete.
S&F in replacent, Ajustable thermal and magnetic release MCCB TP 160 Amps capacity 36 KA 415 Volts 50 HZ complete.
S&F in replacement, MCCB TP 100 Amps capacity 16KA 415Volts 50 HZ complete.
S&F in replacement MCB Single pole and neutral 40 Amps capacity 10 KA 240 Volts 50 HZ complete all as specified and directed .
S&F in replacement MCB single pole (SP) 10 kA of 6 Amps to 32 Amps capacity 240 Volts 50 HZ complete all as specified and directed .
M&L for sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathead 1100V grade FRLSH multistranded copper conductor and drawn through in and including PVC conduit of medium grade and condiut accessaries of suitable size concealed in walls with, necessary civil works for making good distrubed surface, and/or laid on surfaces over ceilings/columns etc and connecting terminal ends to meters and DB's including of 1 run of 6 Sq.mm insulated multistanded FRLSH copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old one complete all as specified and directed. Note;- (i) Two runs of 6 Sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of suitable size of PVC rigid conduit and required conduit accessaries shall be measured as one unit length. (ii) Extra lenght of cable / wire required for connection to MCBs shall not be measured and the measured and the rate quoted per unit shall deemed to be inclusive of the same acordingly.
M&L for sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathead 1100V grade FRLSH multistranded copper conductor and drawn through in and including PVC conduit of medium grade and condiut accessaries of suitable size concealed in walls with, necessary civil works for making good distrubed surface, and/or laid on surfaces over ceilings/columns etc and connecting terminal ends to meters and DB's including of 1 run of 4 Sq.mm insulated multistanded FRLSH copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old one complete all as specified and directed. Note;- (i) Two runs of 4 Sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of suitable size of PVC rigid conduit and required conduit accessaries shall be measured as one unit length. (ii) Extra lenght of cable / wire required for connection to MCBs shall not be measured and the measured and the rate quoted per unit shall deemed to be inclusive of the same acordingly.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 5 of MES SSR Part-I, including taking down old one and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm heavy duty sweep with, blades, and frame and louvers
Supplying and fixing Wall mounting air circulators 400mm sweep,230V Complete all as specified and directed
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm
Taking down the existing unserviceable ceiling of any make/ model and sweep for overhauling / servicing after disconnecting carefully cleaning and checking for unserviceable components, and replacing the defective components such as bearing, rubber bush/bolt, gunmetal bush, capacitor flexible chord and shaft / painting etc., including assembling after lubricating the movable components and installing in its original position connecting, testing and commissioning all as specified and directed by the Engineer-in-charge.
All as per item No.42 above but single phase Exhaust fans and Air Circulator from any height installed in residential/workshops. Note:- Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor/ Rewinding / cord flexiable / shaft shall be measured and paid separately under relavent items of Sch ‘A’.
Supply & fixing rubber bush/bolt /clamps and connected items suitable for ceiling fan of any make/model/ type sweep of 1200/1400 mm all as specified and directed
Supplyand fixing shaft suitable for ceiling fan / Exhaust fan/ pedestal fan/ wall mounted fan/ Air circulator of any make/model and sweep with necessary machining work all as specified and directed by the Engineer-in-charge.
Supply and fixing cord flexible copper conductor, twin core 0.50 Sqmm 1.5m long PVC insulated unsheathed 415 volts grade for ceiling fans all as specified and directed by the Engineer-in-charge. Make : Finolex/Fine Cab
M & L for rewinding of any make/model of fans including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enmelled copper conductor of same gauge/same number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings nd applying air dry insulating arnish and drying the windings thoroughly all as specified and directed for :-
Ceiling fan of 1200 / 1400 mm sweep.
Exhaust fan of 230/300mm sweep
Exhaust fan of 450 mm sweep / Air circulator of 450/600 mm sweep.
Supply only ball bearing suitable for ceiling fan / wall mounting fan/Pedestal fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge. Make : SKF/NBC/TATA/Usha
All as per Item No.50 above but for Exhaust fan / air cirulator of any make / model / sweep.
Supply only gunmetal bush suitable for ceiling fan / wall mounting fan/Pedestal fans of any make/model/ sweep and Exhaust fan of any sweep with necessary machining work as per requirement all as specified and directed by the Engineer-in charge.
S&F fan down rod 1.5/2.0/2.5 complete all as specified and directed.
Supply only capacitor 2.5 mfd suitable for ceiling fan and testing complete all as directed by Engineer-in-charge Make- Tibcon/Capco.
Supply only capacitor 3.5/4 mfd suitable for ceiling fan and testing complete all as directed by Engineer-in-charge Make- Havells/Tibcon/Capco.
Supply and fixing copper conductor, single core 25 sqmm PVC insulated unsheathed 415 volts grade all as specified and directed by the Engineer-in-charge.
EXELLENT POWER CORPORATION (BID ID -3401766)
M/S Harika enterprises (BID ID -3401400)
S.S.ENGINEERING CORPORATION (BID ID -3401912)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .