Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC Ok | |
| 2 | L2₹49.2 L+₹54,890 (1.13%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹49.9 L+₹1.2 L (2.50%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in Cat c(ii) | |
| 5 | Rejected-Technical WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | - | Rejected-Technical Not enlisted in Cat c(ii) |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
15 May 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
MANNING, OPERATION AND COMPREHENSIVE MAINTAINANCE OF LIFTS ALONG WITH CONNECTED MISC E/M WORKS AT BASE HOSPITAL UNDER GE E/M BASE HOSPITAL AT DELHI CANTT-10
2020_MES_340403_1
GE/BH-09/2020-21
Open Tender
Electrical and Maintenance Works
Works
334 days
GE E/M BASE HOSP DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹99,000
Yes
1 Jul 2020
23 Apr 2020
18 May 2020
23 Apr 2020
15 May 2020
7 May 2020
Amount
Comprehensive maintenance of following electrically operated lifts suitable for serving passenger lifts installed at Base Hospital (M/s ThyssenKrupp Elevators (India) as per following details complete all as specified and as directed:-
ADM BLDG (Base Hospital)
(i) Ground + One floor (two landings) with electric power operated doors, auto electric leveling device of capacity 2000 Kgs lift. Make : ThyssenKrupp Elevators (India) installed at Adm bldg in Base Hosp. = Total 01 No.
Note: (i) The above comprehensive maintenance shall be carried out through OEM (M/S ThyssenKrupp Elevators (India) only. The tenderer shall submit an intent of MOU from M/S ThyssenKrupp Elevators (India) for this effect along with the tender in cover 1.
(ii) The contractor shall submit MOU and copy of Annual Maintenance Contract (With machine Nos of each lift) from M/S ThyssenKrupp Elevators (India) within seven days of acceptance of tender (As per proforma given in Appendix 'A' to Perticular specification on stamp paper duly notarized), failing which the contract shall be liable to be cancelled on contractor's default.
(iii) The contractor through OEM shall attend any complaint regarding emergency break down and rescue of trapped persons in the lift within Two Hour, failing which a penalty of Rs 2000.00 per complaint per Hour shall be shall be recovered from the contractor's dues. Any damage or loss on this account shall also bear by the contractor.
Manning & Operation of LIFT installed at Base Hospital ADM Bldg with 01 Semi Skilled Lift operator in 02 Shifts of 08 hrs per day except Sunday and Holiday complete all as specified and directed.
Note for item No 02 :- (i) One operator shall perform only one shift of 08 hours in a day. If the same operator found in other shift a sum of Rs 500/- per day shall be recovered from the contractor's dues. (ii) Contractor shall submit the nominal roll and qualification of operator within 15 days of acceptance of tender. Failing which a penalty of Rs 500/- per shift shall be recovered from the contractor's dues. (iii) Contractor shall ensure attendance of all operator in shift wise if any operator found absent from duty a sum of Rs 1000/- per shift shall be recovered from the contractor's dues. Any damage of loss on this account shall bear by the contractor. (iv) All operator shall wear proper uniform, failing which a recovery of Rs 200/- per shift shall be recovered from the contractor's dues. (v) The payment of contractor's employee shall be made through nationalized bank account of individual and the proof of transaction and the contractor shall submit the same with bank account pass book of employees and own Bank account statement within 15 days of acceptance otherwise a recovery shall be made a sum of Rs 200/- per shift per employee from the contractor's dues. (vi) Operator shall also maintain log sheets/breakdown details register etc & contractor shall provide the log sheet and register or any other stationery etc as required.
(vii) The estimated cost of the work in respect of BOQ Sir item No 2 (as based on minimum wages rates issued vide central/state) is Rs 4,50,000/-. If the quoted amount is found less than the estimated cost of Sir item No 2 of BOQ and tender of lowest bidder is considered for acceptance, then the lowest bidder shall have to deposit FDR in favour of Accepting officer for the difference in estimated cost and Accepted amount in respect of BOQ Sir item No 2 within 30 days from date of acceptance. In case the said FDR is not submitted within 30 days the amount in question shall be recovered from contractor’s first RAR/Final bill whichever is earlier. However the FDR/recovered amount shall be released to the contractor after satisfactory completion of work. Attention is further invited added that when the amount of said recovery mentioned herein above is less than the amount of performance security as indicated under Clause 02 on page 04 of CA and Clause 12 on page 11 of CA, no FDR is required to be submitted for quoting less rate against BOQ Srl Item No 02. However if the amount of performance security is less than the FDR to be submitted for less quoting rate, the difference of performance security amount and FDR amount(for less quoting rates) shall be deposited by the lowest bidder (whose tender is accepted) in the form of FDR for difference amount over and above performance security within 30 days from the date of Acceptance.
Supply only in replacement MPU Card of main panel of LIFT same as Existing complete all as specified and directed.
Supply only in replacement suspension rod, bull dog clamp and anchoring plate assembling complete on load complete all as specified and directed.
Supply only in replacement cabin light 5/6 watt round type 12mm dia for lift complete all as specified and directed. Make- Philips/Wipro/Osram/Havells
Supply only in replacement car top light box with suitable cover for bulb/lamp along with all (flexible wire) sheathed appx 2 to 3 mtrs wiring connection for existing lifts complete all as specified and directed.
Supply only in replacement TOCI Inspection Box with NE300 controller for existing lifts with control of limit switches up and down movement along with all control wiring complete all as specified and directed.
Supply only in replacement Car fan guarding as per sample suitable for 8/13 passenger lift complete all as specified and directed.
Supply only in replacement CIS Panel as per sample suitable for 8/13 passenger lift complete all as specified and directed.
Supply only in replacement landing door seal as per sample suitable for 8/13 passenger lift complete all as specified and directed.
Supply only in replacement break coil 180 to 185 Ohms as per suitable for 8/13 passenger lift complete all as specified and directed.
Supply only in replacement car cabin fan 300 mm sweep 230 Volts to match with existing car cabin fan suitable for lift car cabin fan complete all as specified and directed. Make- Bajaj/CG/Orient/Havells
Supply only in replacement main hoist rope of size 6 strands x 19 of nominal dia 13 mm (in 8 Passenger lift) 2 story heavy duty complete all as specified and as directed. Make- Usha Martin
Supply only in replacement thimble rod for 10mm rope (Car side & CWT Side) complete all as specified and as directed. Make- Yeshawa/Fuji
Supply only in replacement maintenance free battery 12V 17/18AH of 36 Month warranty for ARD for existing lifts complete all as specified and as directed. Make- Exide/Luminous/Amron
Supply only in replacement Single phase 240 Volt, 50 Hz ,1.5KVA,Output Voltage 240V offline UPS, battery connected to Controller working of Automatic Rescue Device & emergency light & fan complete all as specified and as directed.
Supply only in replacement Single phase 240 Volt, 50 Hz, 3KVA, Output Voltage 240V offline UPS, battery connected to Controller working of Automatic Rescue Device & emergency light & fan complete all as specified and as directed.
Note for item Nos 3.00 to 17.00: - Labour charges for the replacement of spare parts shall be included in rate quoted against item No 1 of this BoQ.
S&F in replacement 25A 110 V AC contractor complete all as specified and directed. Make- Siemens/Schneider/L&T
Supply, fixing, testing and commissioning in replacement Automatic Rescue device with Panel and including necessary internal wiring, including ARD batteries 12V 17/07 AH as per site position complete all as specified and directed.
S&F in replacement 40A 110 V AC contractor complete all as specified and directed. Make- Siemens/Schneider/L&T
S&F in replacement 110 V AC Relay complete all as specified and directed. Make- Siemens/Schneider/L&T
S&F in replacement 24 V DC Relay complete all as specified and directed. Make- Siemens/Schneider/L&T
S&F in replacement LOP and COP mad Main Display Board complete all as specified and directed. Make- Siemens/Schneider/L&T
S & F in replacement 100 Amp MCCB, 4 Pole, 50 KA including necessary sheet metal enclosure of size 0.15 x 0.125 x 0.125cm made out of 1.6 mm MS sheet duly powder coated with necessary copper cable for & flexible PVC conduit for internal connection for distribution complete all as specified and directed. Make- L&T/Legrand/Havells/HPL
Supply & laying 50 Sqmm 3.5 core XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, ISI marked with aluminium multi stranded conductor 1100 Volt grade, laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
S & F in replacement 10 Sqmm, multi stranded copper conductor, FRLS, PVC insulated complete all as specified & directed.
Supply, fixing testing & commissioning Automatic phase sequence corrector RPC-15 HP suitable for 15 HP which will automatically correct input supply reverse, phase, also protections against single phasing voltage unbalancing, low voltage, high voltage with time delay complete cable lugs & thimble complete all as specified & directed. Make: SECO/Universal Switch Gear Control/ BBN Controls.
Supply installing Testing and commissioning in replacement along with all connected accessories, C.I /cast traction Sheave 4 grooves pully Cide OD 520*4*10mm bore size 90mm key size 20*7 bore length with main hoist rope of size 110mm dia heavy duty (08 Passenger Lift) two Storey) as per requirement welding/Brazing etc Complete and testing on load complete all as specified & directed. Make- OTIS/THYSSEN KRUPP/KONE
Taking down old/unserviceable FTL fittings of any type/make and supply & fixing LED 20 W Tube Light fitting complete energy efficient and tube rod complete all as specified & directed.
Taking down old unserviceable bulk head fitting and supply and fixing 9W LED bulk head luminaries complete all as specified and directed.
M & L For shifting of 320 KVA DG set complete in following operations complete all as specified and as directed: - 1. Dismantling of DG complete with its connected accessories (including all types of cables, change over, panels and switch gears) from its existing location with cranes and necessary tools and manpower. 2. Shifting of complete DG set and its connected accessories to New location within 2 KM distance as directed. 3. Installation, connecting, Testing and commissioning of DG Set at new location complete all as specified and as directed.
Supply, Installation, Testing & Commissioning in repair LT panel with inbuilt energy monitoring meters and RTUs capable of acquiring the data from various sensors/ relays/ meters/ breakers etc., conditioning data for transmitting, transferring data through RTU to the cloud server. Also, the unit shall be able to perform bi-directional communication for future use. The minimum size of indoor panel shall be 1200X700X400MM fabricated from 2.0 mm thick CRCA sheet and shall be powder coated consisting of following accessories/components/software's complete all as specified and as directed:-
(a) MCCB 800A 36KA TP - 01 NO with O/L and S/C WITH ROH (Make: Schneider, Siemens, ABB) (b) MULTIFUNCTION METER RS485 Port Acc. Class 0.2 - 01 No (Make: -Schneider, Siemens, Socomec) (c) Phase INDICATION Lamp R/Y/B 230Vac (L&T, Schneider) - 01 Set (Three) (d) INDICATION LIGHT ON/OFF/TRIP 230Vac (Make: L&T, Schneider, Siemens) - 03 Nos (e) CT-800/5A 15VA Cl-0.2 (Make: -Rishabh, AE, Matrix) - 03 Nos (f) 6A SP MCB C-Curve 10KA (Make: - L&T, Schneider, Siemens) - 04 Nos (g) The LT panel shall be fitted with accessories such as THERMOSTER & SPACE HEATER, DOOR SWITCH 1CO, PANEL LIGHT 220V, 6A SP MCB C-Curve 10KA and company fitted wiring/ cabling complete all as specified and as directed.
Panel shall be with Facility management software (same make as RTU and fully compatible with the RTU) Software subscription for 5 years subscription, maintenance and support as per specifications. Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported 4G/ 3G/ 2G SIM cards for 5 years subscription. Data services must be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network without any intervention. System should support changing of service providers without changing SIM cards (future ready). Software must work without any need of static IP. No static IP will be provided for any location (Make: Schneider, Right Watts, GE) All above must be connected with suitable accessories and wiring/ cabling of reputed makes. Belden/ Lapp cable must be used for RS485 loops.
Supply, Installation, Testing & Commissioning in repair LT panel with inbuilt energy monitoring meters and RTUs capable of acquiring the data from various sensors/ relays/ meters/ breakers etc., conditioning data for transmitting, transferring data through RTU to the cloud server. Also, the unit shall be able to perform bi-directional communication for future use. The minimum size of indoor panel shall be 900X450X350MM fabricated from 2.0 mm thick CRCA sheet and must be powder coated consisting of following accessories/components/software's complete all as specified and as directed: -
(a) MCCB 160A 36KA TP - 01 NO with O/L and S/C WITH ROH (Make: -Schneider, Siemens, ABB) (b) MULTIFUNCTION METER RS485 Port Acc. Class 0.2 - 01 No (Make: -Schneider, Siemens, Socomec) (c) Phase INDICATION Lamp R/Y/B 230Vac (Make : -L&T, Schneider, Siemens) - 01 Set (Three) (d) INDICATION LIGHT ON/OFF/TRIP 230Vac (Make : -L&T, Schneider, Siemens) - 03 Nos (e) CT-160/5A 15VA Cl-0.2 (Make: -Rishabh, AE, Matrix) - 03 Nos (f) 6A SP MCB C-Curve 10KA (Make: - L&T, Schneider, Siemens) - 04 Nos (g) The LT panel shall be fitted with accessories such as THERMOSTER & SPACE HEATER, DOOR SWITCH 1CO, PANEL LIGHT 220V, 6A SP MCB C-Curve 10KA and company fitted wiring/ cabling complete all as specified and as directed.
Panel shall be with Facility management software (same make as RTU and fully compatible with the RTU). Software subscription for 5 years subscription, maintenance and support as per specifications. Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported. 4G/ 3G/ 2G SIM cards for 5 years subscription. Data services must be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network without any intervention. System should support changing of service providers without changing SIM cards (future ready). Software must work without any need of static IP. No static IP will be provided for any location (Make: Schneider, Right Watts, GE) All above must be connected with suitable accessories and wiring/ cabling of reputed makes. Belden/ Lapp cable must be used for RS485 loops.
Supply, Installation, Testing & Commissioning in repair LT panel with inbuilt energy monitoring meters and RTUs capable of acquiring the data from various sensors/ relays/ meters/ breakers etc., conditioning data for transmitting, transferring data through RTU to the cloud server. Also, the unit shall be able to perform bi-directional communication for future use. The minimum size of indoor panel shall be 1200X600X350MM fabricated from 2.0 mm thick CRCA sheet and must be powder coated consisting of following accessories/components/software's complete all as specified and as directed: -
(a) MCCB 400 A 36KA TP - 01 NO with O/L and S/C WITH ROH (Make : -Schneider, Siemens, ABB) (b) MULTIFUNCTION METER RS485 Port Acc. Class 0.2 - 01 No (Make : Schneider, Siemens, Socomec) (c) Phase INDICATION Lamp R/Y/B 230Vac (Make: -L&T, Schneider, Siemens) - 01 Set ( Three) (d) INDICATION LIGHT ON/OFF/TRIP 230Vac (Make: L&T, Schneider, Siemens) - 03 Nos (e) CT-400/5A 15VA Cl-0.2 (Make: -Rishabh, AE, Matrix) - 03 Nos (f) 6A SP MCB C-Curve 10KA (Make: -L&T, Schneider, Siemens)- 04 Nos (g) The LT panel fitted with accessories such as THERMOSTER & SPACE HEATER, DOOR SWITCH 1CO, PANEL LIGHT 220V, 6A SP MCB C-Curve 10KA and company fitted wiring/ cabling complete all as specified and as directed.
Panel shall be with Facility management software (same make as RTU and fully compatible with the RTU) Software subscription for 5 years subscription, maintenance and support as per specifications. Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported 4G/ 3G/ 2G SIM cards for 5 years subscription. Data services must be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network without any intervention. System should support changing of service providers without changing SIM cards (future ready). Software must work without any need of static IP. No static IP will be provided for any location (Make: Schneider, Right Watts, GE) All above must be connected with suitable accessories and wiring/ cabling of reputed makes. Belden/ Lapp cable must be used for RS485 loops.
Supply, Installation, Testing & Commissioning in repair LT panel with inbuilt energy monitoring meters and RTUs capable of acquiring the data from various sensors/ relays/ meters/ breakers etc., conditioning data for transmitting, transferring data through RTU to the cloud server. Also, the unit shall be able to perform bi-directional communication for future use. The size of indoor panel should be 900X500X300MM (minimum) fabricated from 2.0 mm thick CRCA sheet and must be powder coated consisting of following accessories/components/software's complete all as specified and as directed:-
(a) MCCB 200 A 36KA TP - 01 NO with O/L and S/C WITH ROH (Make: -Schneider, Siemens, ABB) (b) MULTIFUNCTION METER RS485 Port Acc. Class 0.2 - 01 No (Make: -Schneider, Siemens, Socomec) (c) Phase INDICATION Lamp R/Y/B 230Vac (Make: - L&T, Schneider, Siemens) - 01 Set ( Three) (d) INDICATION LIGHT ON/OFF/TRIP 230Vac (Make: - L&T, Schneider, Siemens) - 03 Nos (e) CT-200/5A 15VA Cl-0.2 (Make: -Rishabh, AE, Matrix) - 03 Nos (f) 6A SP MCB C-Curve 10KA (Make: - L&T, Schneider, Siemens)- 04 Nos (g) The LT panel fitted with accessories such as THERMOSTER & SPACE HEATER, DOOR SWITCH 1CO, PANEL LIGHT 220V, 6A SP MCB C-Curve 10KA and company fitted wiring/ cabling complete all as specified and as directed.
Panel shall be Facility management software (same make as RTU and fully compatible with the RTU) Software subscription for 5 years subscription, maintenance and support as per specifications. Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported 4G/ 3G/ 2G SIM cards for 5 years subscription. Data services must be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network without any intervention. System should support changing of service providers without changing SIM cards (future ready). Software must work without any need of static IP. No static IP will be provided for any location (Make: Schneider, Right Watts, GE) All above must be connected with suitable accessories and wiring/ cabling of reputed makes. Belden/ Lapp cable must be used for RS485 loops.
Supply, Installation, Testing & Commissioning in repair LT panel with inbuilt energy monitoring meters and RTUs capable of acquiring the data from various sensors/ relays/ meters/ breakers etc., conditioning data for transmitting, transferring data through RTU to the cloud server. Also, the unit shall be able to perform bi-directional communication for future use. The minimum size of indoor panel shall be 1200X600X350MM, fabricated from 2.0 mm thick CRCA sheet and must be powder coated consisting of following accessories/components/software's complete all as specified and as directed:-
(a) MCCB 630 A 36KA TP - 01 NO with O/L and S/C WITH ROH (Make: -Schneider, Siemens, ABB) (b) MULTIFUNCTION METER RS485 Port Acc. Class 0.2 - 01 No (Make : -Schneider, Siemens, Socomec) (c) Phase INDICATION Lamp R/Y/B 230Vac (Make: - L&T, Schneider, Siemens) - 01 Set ( Three) (d) INDICATION LIGHT ON/OFF/TRIP 230Vac (Make: - L&T, Schneider, Siemens) - 03 Nos (e) CT-630/5A 15VA Cl-0.2 (Make: -Rishabh, AE, Matrix) - 03 Nos (f) 6A SP MCB C-Curve 10KA (Make: - L&T, Schneider, Siemens)- 04 Nos (g) The LT panel fitted with accessories such as THERMOSTER & SPACE HEATER, DOOR SWITCH 1CO, PANEL LIGHT 220V, 6A SP MCB C-Curve 10KA and company fitted wiring/ cabling complete all as specified and as directed.
Panel shall be with Facility management software (same make as RTU and fully compatible with the RTU) Software subscription for 5 years subscription, maintenance and support as per specifications. Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported 4G/ 3G/ 2G SIM cards for 5 years subscription. Data services must be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network without any intervention. System should support changing of service providers without changing SIM cards (future ready). Software must work without any need of static IP. No static IP will be provided for any location (Make: Schneider, Right Watts, GE) All above must be connected with suitable accessories and wiring/ cabling of reputed makes. Belden/ Lapp cable must be used for RS485 loops.
Note for item Nos 32.00 to 36.00:- The above Panels work shall be done through: any of Schneider/ Right Watts/ GE . The tenderer shall submit an intent of MOU from any of above mentioned manufacturer for this effect along with the tender in cover 1.
S&F in replacement LED based sign board with LOGO and English Letter at size (3.75 Sqft) with stainless steel letters with acrylic top and back ACP channels Words to be illuminated with LED modular and complete electric wiring with copper wire of size 1.5 Sqmm. All electric connection shall be tightened and fixed with proper lugs. All the words / LOGO shall be properly fixed on sign board including taking down old rusted sign board, including taking down all electrical wiring, and dismantling fitting fixture complete all as specified and as directed. Note:- Quoted rates shall be inclusive of the cost of Maroon Colour 3mm ACP sheet, GI Channel and PCC work. and LOGO etc complete.
S&F MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated inclusive of one coat of aluminium paint over and including one coat of red oxide including taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers complete all as specified and as directed.
S&F in replacement anti climbing device, spikes type, fabricated out of mild steel bars of size 16 Sqmm (round, square and flat) including MS Flat 32x6mm, nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete with and including painting with two coats of aluminium paint over and including a coat of red oxide primer to match it with existing surfaces complete all as specified and as directed.
S&F in repair On load change over switch of 800 Amp cap, 4 pole by pass switch with MS Enclosure made of 3.15 mm thick steel sheet and extensible handle mounting stand made from 35 x 35 x 5mm thick channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and as directed. Make:- Havells Cat No IHCBFO0800 or equivalent model of L&T / Schneider/ Siemens
S&F in repair On load change over switch of 1000 Amp cap, 4 pole by pass switch with MS Enclosure made of 3.15 mm thick steel sheet and extensible handle mounting stand made from 35 x 35 x 5mm thick channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and as directed. Make:- Havells Cat No IHCBFO1000 or equivalent model of L & T / Schneider/Siemens
S & F in replacement 630 Amp MCCB, 4 Pole, 50 KA including necessary sheet metal enclosure of size 0.15 x 0.125 x 0.125cm made out of 1.6 mm MS sheet duly powder coated with necessary copper cable for & flexible PVC conduit for internal connection for distribution complete all as specified and as directed.
All as per item No. 42 here in before but 400 Amp MCCB TPN 35 KA complete all as specified and directed.
S&F in repair MCCB 4 pole 415V adjustable, 250Amps with breaking capacity 35KA including cable connections in existing panel complete all as specified and as directed.
All as per item No.44 here in before but 200 Amps, breaking capacity 35 KA complete all as specified and directed.
All as per item No.44 here in before but 100 Amps adjustable thermal & adjustable magnetic setting breaking capacity 35 KA complete all as specified and directed.
S & F cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
S&F LED Street Light fitting 90 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED Street Light fitting 120 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED FLOOD Light fitting 150 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and directed.
S&F LED FLOOD Light fitting 250 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and directed.
Iconic Engineers
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .