Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹14.8 L+₹1.1 L (8.40%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L1. | |
| 3 | L3₹15.2 L+₹1.5 L (11.2%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L3 | Rejected-Finance Over all rates are higher than L1. | |
| 4 | L4₹16.9 L+₹3.2 L (23.4%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L4 | Rejected-Finance Over all rates are higher than L1. |
Tender Value
₹20.7 L
EMD Value
₹41,400
Closing Date
2 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Bareilly
CWE(AF) Bareilly PIN-243002
REP MAINTENANCE OF TRANSFORMER HT CABLE VCB AT MEMAURA
2021_MES_465681_1
81272/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Memaura
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I)(AF)Memaura
₹41,400
Yes
14 Oct 2021
6 Aug 2021
4 Sept 2021
6 Aug 2021
2 Sept 2021
21 Aug 2021
6 Aug 2021 - 16 Aug 2021
60 days
Amount
Supply and Fixing of 33KV 10KA metal oxide (Gap less type), heavy duty single pole self supporting sation class, class ii insulation level 70 KV including taking out complete all as specified and directed.
Supply and Fixing of 11KV 10KA metal oxide (Gap less type), heavy duty single pole self supporting sation class, class ii insulation level 28/75 KV including taking out complete all as specified and directed.
Replacement of HT 11 KV outdoor type triple pole switch air break , gang operated mounted on insulator (09 nos) and steel frame,with operating mechnisam worked from ground level for current rating upto 400 amps for working 11000 volts with heavy duty gun metal or brush metal parts both top and bottom contracts with one copper ribon, bruss/copper terminal clamps having six nuts & bolts for one connection point complete with locking arrengment and taking down of unserviceable and taking as credit complete all as specified and directed. (Make : PACTAILLEDATLAS/RaychemRPG).
Supply & fixing DO fuse assembly, triple pole mounted on porcelain HT insulator 6 Nos and MS galvanised steel frame rating upto 200 Amp, 11000 Volt, post insulator type on channel (two insulator for one phase) complete with expulsion type fiberglass fuse carrier barral type and including DO fuze and electrical connections compleate all as specified and directed by Engineer-in-Charge. (Make : PACTAILLED/JAIPURIA/ RAYCHEM RPG).
Supply, laying & testing HT cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminum conductor, 11000 volts grade cross sectional area of size 95 SQMM 3 core complete all as specified and directed. Note:- Earth work shall be meaursed and paid separately
Supply, laying & testing HT cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminum conductor, 11000 volts grade cross sectional area of size 240 SQMM 3 core complete all as directed
Supply, laying & testing HT cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminum conductor, 11000 volts grade cross sectional area of size 120 SQMM 3 core complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm including taking down old joint complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old joint complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm including taking down old joint complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm including taking down old joint complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 Sqmm including taking down old joint complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected ot galvanised iron strip of size 32 x 6mm earth lead by means of bolt, nuts, washers of galvanised iron or steel, earth strip protected by and including GI pipe 40mm dia bore (light grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 3 of SSR Part-I and testing complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for laying cable and getting out soft/loose soil complete all as specified and directed by Engr-in-charge.
Removing excavated material to a distance n. exc 16 mtr and depositing where as directed as a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr -in-charge.
M&L for Brick, sub class ‘B’, old size, laid in trenches as in cable protection complete all as specified and as directed.
M&l sand cushioning 8cm below the cable and 15cm above the cable for cable protection in trenches complete all as specified and directed by Engr-in-charge.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade 80 mm dia complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately Make: - QST/ TATA / JINDAL
M&L cross arms, bracing, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for holes bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fix in replacement pin type insulator porcelain vitreous green, brown or white suitable for 11000 Volts grade including one galvanised mild steel spindle two GI washers, one GI nut, bolt and two washers etc of size 150mm height and 150mm dia, complete all as specified and directed.
Supply and fix 2V VRLA 100 ah battries cell suitable for battery bank complete all as specified and directed. Make : Exide Model UPST100 or equivalent in Amaron/ Luminous.
S&F in replacement,33 KV PT single phase of ratio 11000/√3/110/√3, VA burden -100 VA, Accuracy class-1.0, type-Resin cast 50 Hz complete all as specified and directed.
M&L for Painting of transformer upto 175 KVA after preparation of existing surface of transformer , remove oil stains, dust etc and applying two coat of hammertone by spray paint incl writing SM No/MES No complete all as specified and directed.
M&L for Painting of transformer excd 175 KVA but not exc 500 KVA after preparation of existing surface of transformer , remove oil stains, dust etc and applying two coat of hammertone by spray paint incl writing SM No/MES No complete all as specified and directed.
M&L for Painting of transformer of capacity 2000 KVA 33/11 kV after preparation of existing surface of transformer , remove oil stains, dust etc and applying two coat of hammertone by spray paint incl writing SM No/MES No complete all as specified and directed.
M&L for Painting of transformer of capacity 500 KVA after preparation of existing surface of transformer , remove oil stains, dust etc and applying two coat of hammertone by spray paint incl writing SM No/MES No complete all as specified and directed.
Dehydration /Filteration of Transformer Oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS- 355, Breakdown voltage should not be less than 50 KV complete all as specified and directed.
Servicing of HT (11KV ) switchgear panel , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, through authorized representative service centre of VCB manufacturer channel partner /OEM or UPPCL approved vendor for VCB repairing agency , Testing for smooth operation manual/ remote after caliberation of relay and resetting & generation of testing report by the primary injection set For 11KV VCB for OC/EF ,parameter of relay setting ,complete all as specified and directed by Engr-in-Charge. Note: Worn out minor parts shall be deemed to be included in unit rate.
Servicing of HT (33 KV ) panel / VCB , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, through authorized representative service centre of VCB manufacturer channel partner /OEM or UPPCL approved vendor for VCB repairing agency , Testing for smooth operation manual/ remote after caliberation of relay and resetting & generation of testing report by the primary injection set For 33 KV VCB for OC/EF ,parameter of relay setting ,complete all as specified and directed by Engr-in-Charge. Note: Worn out minor parts shall be deemed to be included in unit rate.
Supply and fixing in repairs spring charging motor suitable for fixing with 33 KV outdoor VCB panels complete all as specified and directed.
Testing of 33/11 KV, 02 MVA step down transformer on site and generation of testing report and earth resistance test, O.T.I/ W.T.I , Buchholz circuit test serviciability and wiring from VCB panel to transformer , including following tests complete all as specified and as directed : - a) Insulation Test (IR/ Megger Values ) b) Open Circuit/Ratio test. c) Short Circuit Test. d) Magnetic Balance Test. e) Magnetization current Test. f) BDV Value of T/F Oil.
Suppy and filling silica gel of good quality in existing silica gel breather of transformer complete all as specified and directed.
Supply and fixing Battery Charging transformer 0 - Amperes, 12 Volts DC /24 volts complete all as specified and directed.
S&F post type insulator porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle ,two galvanised iron washers and one galvanised iron nut complete suitable for 33 KV grade complete all as specified and directed.
Detection of pin point fault in HT cable (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator,acoustic fault locator and reflectometer (laptop based) complete all as specified and as directed by Engr-in-Charge. Notes- (i) Cable fault locating machine to be arranged at site with in 12 hrs after intimation (ii) Earth work will be measured seperatly. (iii) Cost of transpotation in unit rate is deemed to be included.
M&L Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Disconnecting the transformer of capacity 100 to 500KVA, indoor/outdoor from HT/LT side carefully at site, for top overhauling of transformer dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, supply and replacing the 5 mm thick rubberised cork sheet gasket for tank top cover , repair of transformer oil leakages from HT/ LT bushing and reassembling the complete , reconnecting the HT/LT supply cable ends at the site and testing complete all as specified and directed
Supply & Fix following accessories of Transformer in replacement of unservicable parts complete all as specified and directed :-
(a) Temperature gauge 0-100 degree Celcius suitable for distribution transformer 11/0.433 KVA complete all as specified and as directed
(b) Porcelain transformer bushing 11 KV/250 Amps, complete, with high voltage brass metal parts as per IS-3347 Part-III & IS 2009 complete all as specified and as directed. Note: Opening of top cover of Transformer if required deemed to be included in item rate.
(c) LV brass metal part complete with porcelain bushing, 1.1 KV upto 500 KVA transformer.
(d) Silicagel breather of capacity 11 KV Transformer 500 KVA complete all as specified and as directed.
M/S WALIA TRADESRS
Unnati Engineers
Ashirwad Contractor and Supplier
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .