GEMC-511687732481775
Awarded to DIGITAL MARKETING SYSTEMS PVT. LTD.
₹1.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE_ 319 DIGITAL CLAMP METER | FLUKE 319 | - | 6 NOS | ₹22,890 | 137,340 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: FLUKE
Model: FLUKE 319 122 KANCHAN BAGH KANCHAN BAGH KANCHAN BAGH INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: FLUKE
Model: FLUKE 319 | L1 | Qualified | |
| 2 | L2₹1.4 L+₹3,258 (2.37%)Qualified Make: FLUKE
Model: FLUKE 319 66 2ND CROSS STREET PALLAVAN NAGAR EXT MADURAVOYAL CHENNAI PORUR TIRUVALLUR TAMIL NADU 600095 | CHENNAI | TAMIL NADU | 600095 | Make: FLUKE
Model: FLUKE 319 | L2 | Qualified | |
| 3 | L3₹1.5 L+₹14,100 (10.3%)Qualified Make: FLUKE
Model: FLUKE 319 DR NOOR MOHAMMAD MARKET COL J ALI ROAD NEAR RLY GATE NO 2 RAM MANDIR LANE LAKHOTKIA GUWAHATI KAMRUP ASSAM 781001 INDIA | KAMRUP METRO | ASSAM | 781001 | Make: FLUKE
Model: FLUKE 319 | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Oct 2018, 8:00 pmClosed
true rms clamp meter True Rms Clamp Meter ( 6 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERAL FEATURES Type Hand Held Hand Held Display 3.5 digit Backlit LCD 3.5 digit Backlit LCD Measurement Type True RMS True RMS count 6000 6000 MEASUREMENT FEATURES Resistance Measurement Range 4 4
10
100
1000 Resistance Measurement Accuracy (+/-) 1.5 0.5
1
1.5
2 Frequency Measurement Range 500 500.0 Frequency Measurement Accuracy (+/-) 0.5 0.5
0.3
0.1 AC Current Measurement Range 1000 1000.0 AC Current Measurement Accuracy (+/-) 1.5 1.5 1/4 AC Voltage Measurement Range 600 600.0 AC Voltage Measurement Accuracy (+/-) 1.5 1.5 DC Current Measurement Range 1000 1000.0 DC Current Measurement Accuracy (+/-) 1.5 1.5 DC Voltage Measurement Range 400 400.0 DC Voltage Measurement Accuracy (+/-) 1.5 1.5 Other features
if applicable The accuracy specifications aply at 73 °F ± 41 °F (23 °C ± 5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. * GENERIC Jaw Size (Dia in Closed State) 38 * Dimensions (H x W x L) (mm x mm x mm) 6.39 in x 2.29 in x 1.20 in (162.4 mm x 58.25 mm x 30.5 mm) * Weight 384 * POWER REQUIREMENTS Power Requirements Battery Operated * Type of Battery Non- Rechargeable (Alkaline) * if rechargeable
then chemistry of the battery lithium ion * if Non-rechargeable
then size of the battery cell 9-V rectangular battery * Number of non- rechargeable the battery/cell 4 * Voltage of rechargeable Battery milliamphere hour 2800 * 2/4 Suitable charger/adaptor provided NA * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 40 * Operating Humidity (RH) 80 * SAFETY Safety Certification UL * Safety Rating CAT III 600 V of IEC 61010 -2-D31 CAT III 600 V of IEC 61010 -2-D31
CAT IV 300 V of IEC 61010 -2-D31 ACCESSORIES Details of the Standard Accessories Supplied with the Equipment N/A * SERVICE Warranty 1 1.0 TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH false * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. 3/4 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 B. P. Singh 495450
4TH FLOOR
VIKAS BHAWAN JAMNIPALI 6 60
613348
GEM/2018/B/87084
GeM Contract
true rms clamp meter
GeM Contract
60 days
Chhattisgarh; Korba
PRODUCT
Awarded to DIGITAL MARKETING SYSTEMS PVT. LTD.
₹1.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE_ 319 DIGITAL CLAMP METER | FLUKE 319 | - | 6 NOS | ₹22,890 | 137,340 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| true rms clamp meter True Rms Clamp Meter ( 6 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERAL FEATURES Type Hand Held Hand Held Display 3.5 digit Backlit LCD 3.5 digit Backlit LCD Measurement Type True RMS True RMS count 6000 6000 MEASUREMENT FEATURES Resistance Measurement Range 4 4 | - | - | - |
| 10 | - | - | - |
| 100 | - | - | - |
| 1000 Resistance Measurement Accuracy (+/-) 1.5 0.5 | - | - | - |
| 1 | - | - | - |
| 1.5 | - | - | - |
| 2 Frequency Measurement Range 500 500.0 Frequency Measurement Accuracy (+/-) 0.5 0.5 | - | - | - |
| 0.3 | - | - | - |
| 0.1 AC Current Measurement Range 1000 1000.0 AC Current Measurement Accuracy (+/-) 1.5 1.5 1/4 AC Voltage Measurement Range 600 600.0 AC Voltage Measurement Accuracy (+/-) 1.5 1.5 DC Current Measurement Range 1000 1000.0 DC Current Measurement Accuracy (+/-) 1.5 1.5 DC Voltage Measurement Range 400 400.0 DC Voltage Measurement Accuracy (+/-) 1.5 1.5 Other features | - | - | - |
| if applicable The accuracy specifications aply at 73 °F ± 41 °F (23 °C ± 5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. * GENERIC Jaw Size (Dia in Closed State) 38 * Dimensions (H x W x L) (mm x mm x mm) 6.39 in x 2.29 in x 1.20 in (162.4 mm x 58.25 mm x 30.5 mm) * Weight 384 * POWER REQUIREMENTS Power Requirements Battery Operated * Type of Battery Non- Rechargeable (Alkaline) * if rechargeable | - | - | - |
| then chemistry of the battery lithium ion * if Non-rechargeable | - | - | - |
| then size of the battery cell 9-V rectangular battery * Number of non- rechargeable the battery/cell 4 * Voltage of rechargeable Battery milliamphere hour 2800 * 2/4 Suitable charger/adaptor provided NA * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 40 * Operating Humidity (RH) 80 * SAFETY Safety Certification UL * Safety Rating CAT III 600 V of IEC 61010 -2-D31 CAT III 600 V of IEC 61010 -2-D31 | - | - | - |
| CAT IV 300 V of IEC 61010 -2-D31 ACCESSORIES Details of the Standard Accessories Supplied with the Equipment N/A * SERVICE Warranty 1 1.0 TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH false * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. 3/4 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 B. P. Singh 495450 | - | - | - |
| 4TH FLOOR | - | - | - |
| VIKAS BHAWAN JAMNIPALI 6 60 | - | - | - |
Exempted
27 Dec 2018
14 Sept 2018
contract_GEMC-511687732481775.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_613348.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .