| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹14.2 L+₹38,761.10 (2.81%)Rejected-Finance | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹15.0 L+₹1.2 L (8.51%)Rejected-Finance | L3 | Rejected-Finance Not a lowest tender | |
| 4 | L4₹15.9 L+₹2.1 L (15.2%)Rejected-Finance | L4 | Rejected-Finance Not a lowest tender | |
| 5 | L5₹16.4 L+₹2.6 L (19.0%)Rejected-Finance | L5 | Rejected-Finance Not a lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Oct 2022, 6:00 pmClosed
GE AF Adm Area Gwalior
GE AF Adm Area Gwalior 474020
REPAIR/REPLACEMENT OF MOTOR PUMP STARTER AND ELECTRIC PANEL OF WATER SUPPLY INSTALLATIONS AT AF STN GWALIOR
2022_MES_551130_1
8244/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AF Stn Gwalior
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF Adm Area Gwalior
₹40,000
Yes
9 Jan 2023
10 Sept 2022
15 Oct 2022
10 Sept 2022
7 Oct 2022
24 Sept 2022
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 m width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I
Supply only Ammeter 0 – 100 Amps, 96 mm x 96mm, digital type of accuracy class 0.5 suitable for 50Hz, 3 Phase, 415 Volts AC supply complete all as specified and directed. (Make : AE/Meco /Rishab/ Enerco)
Supply only Voltmeter 0 – 500 Volts, 96 mm x 96mm, digital type of accuracy class 0.5 suitable for 50Hz, 3 Phase, 415 Volts AC supply complete all as specified and directed(Make : AE/Meco /Rishab/ Enerco
Supply only current transformer of CT ratio 100/5 Amps suitable for 50Hz, 3 Phase, 415 Volts AC supply complete all as specified and directed. (Make : AE/Meco / Rishab/ Enerco
Supply only Indicating lamps neon type with holder for 12 volts DC supply complete all as specified and directed. (Make : BCH/L&T)
Supply only Moulded fuse holder and fuse base, HBC type for 415 volts AC circuit having rating of 20 Amps with BS type fuse link complete all as specified and directed. (Make: C&S(Electric)/L&T/BCH/Siemens).
Supply only phase indicator LED type (red/green) complete all as specified and directed. (Make: C&S(Electric)/BCH/L&T).
Supply only Single Phase preventer complete all as specified and directed Make: Minilec Model VSP D2 or equivalent make of L & T
Preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enameled paint (grey in color) over a coat of red oxide primer with using spray machine on old prepared surfaces complete all as specified and directed. Note : Rates quoted by the contractor are deemed to include for writing the MES /SM No and other relevant details with paint in the pattern and style as approved by the Engineer-in-Charge
Disconnecting and taking down old unserviceable MCCB and supply and fixing MCCB, four Pole, 415 V all as specified and directed for following Amps & breaking capacity :- (Make: Legrand/C&S(Electric)/L&T) (a) 125 Amps, 25/26 KA
(b) 250 Amps , 35/36/37 KA
Disconnecting and taking down old unserviceable Isolator TPN and supply & fixing Isolator TPN, 415 V, 63 Amps (‘C’ series) having current rating 10 KA complete all as specified and directed. Make : Legrand/L&T/C & S (Electric)
S&F in repair thermal over load relay auto and manual resetting having capacity 17-25 Amp suitavle for contactor CN5 to CN6 complete all as specified and directed. Make: L&T / Havells/ Siemens
S&F in repair thermal over load relay auto and manual resetting having capacity 30-40 Amp suitavle for contactor CN5 to CN6 complete all as specified and directed. Make: L&T / Havells/ Siemens
Disconnecting ,taking out and removing from trenches/ducts/sleeve/on pole/wall etc existing LT UG XLPE insulated, armoured cable of any description, any size/core and in any position complete all as specified and directed for the following sizes of cable :- Note: Earth work shall be measured & paid separately under respective item. (a) 95 sqmm 3.5 Core
(b) 70 Sqmm 3.5 Core
(b) 50 Sqmm 3.5 Core
(c ) 35 Sqmm 3.5 Core
(d) 25 Sqmm 3.5 Core
Supplying, laying, jointing & testing XLPE insulated & PVC sheathed armoured LT cable, 1100 volts grade heavy duty with aluminium conductor of the following sizes laid in trenches/pipe/fixed on the wall etc complete all as specified and directed:- Make : Premier Cable/National Cable Co/CCI/Gloster/Asian Cables/Incab/Finolex) (a) 95 sqmm 3.5 Core
(b) 70 Sqmm 3.5 Core
(b) 50 Sqmm 3.5 Core
(c ) 35 Sqmm 3.5 Core
(d) 25 Sqmm 3.5 Core
Supply, laying & fixing in replacement GI light grade pipes of size 80 mm dia for cable protection laid in trenches/floor/roof and on the walls, with all accessories, all as specified and directed. Make: Jindal/Tata/TT Swastik
Supply, laying & fixing in replacement GI light grade pipes of size 50 mm dia for cable protection laid in trenches/floor/roof and on the walls, with all accessories, all as specified and directed. Make: Jindal/Tata/TT Swastik
Taking down old /unsv MPCB any capacity and any make. S&F MPCB relay range 13-18Amp , breaking capacity not less than 15kA at 415 Volt type MB2-20 Make: Havells or equivalent of CROMPTON/INDO ASIAN with and including MPCB enclosure having IP-65 protection type MB2-E Make: Havells or equivalent of CROMPTON/INDO ASIAN complete all as specified and directed.
Taking down old /unsv MPCB any capacity and any make. S&F MPCB relay range 17-23 Amp , breaking capacity not less than 15kA at 415 Volt type MB2-21 Make: Havells or equivalent of CROMPTON/INDO ASIAN L&T/BCH with and including MPCB enclosure having IP-65 protection type MB2-E Make: Havellsor equivalent of CROMPTON/INDO ASIAN complete all as specified and directed.
Taking down old /unsv MPCB any capacity and any make. S&F MPCB relay range 24-32 Amp , breaking capacity not less than 10kA at 415 Volt type MB2-32 Make: Havells or equivalent ofCROMPTON/INDO ASIAN with and including MPCB enclosure having IP-65 protection type MB2-E Make: Havells or equivalent of CROMPTON/INDO ASIAN complete all as specified and directed.
Taking down star- delta starter any make and capacity and S&F deluxe automatic star-delta submersible pump starter 415 Volt, 50 Hz having range 10HP/7.5 KW contractor size 18 overload relay range 9-13 Amp complete all as specified and directed. Make: Havells or equivalent of L&T/C&S
Taking down star- delta starter any make and capacity and S&F deluxe automatic star-delta submersible pump starter 415 Volt, 50 Hz having range 12.5 HP/9.3 KW contractor size 18 overload relay range 12-18Amp complete all as specified and directed. Make: Havells or equivalent of L&T/C&S
Taking down star- delta starter any make and capacity and S&F deluxe automatic star-delta submersible pump starter 415 Volt, 50 Hz having range 20HP /14.9 KW contractor size 32 overload relay range 17-25 Amp complete all as specified and directed. Make: Havells or equivalent of L&T/C&S
Taking down star- delta starter any make and capacity and S&F deluxe automatic star-delta submersible pump starter 415 Volt, 50 Hz having range 30HP /22.4KW contractor size 50overload relay range 30-40 Amp complete all as specified and directed. Make: Havells or equivalent of L&T/C&S
Taking down old /unsv electric panel board of any capcity and any description and any location with and including of electrical connection all as specified and direcetd
S&F in repair power contactor type MNX 415 Volts having capacity 18 Amp 1 No and 1 NC MNX 18 complete all as specified and directed. Make: L&T /Havells/Siemens
S&F in repair power contactor type MNX 415 Volts having capacity 22 Amp 1 No and 1 NC MNX 22 complete all as specified and directed. Make: L&T /Havells/Siemens
S&F in repair power contactor type MNX 415 Volts having capacity 32 Amp 1 No and 1 NC MNX 32 complete all as specified and directed. Make: L&T /Havells/Siemens
S&F in repair power contactor type MNX 415 Volts having capacity 50 Amp 1 No and 1 NC MNX 50 complete all as specified and directed. Make: L&T /Havells/Siemens
S&F in repair power contactor type MNX 415 Volts having capacity 80 Amp 1 No and 1 NC MNX 80 complete all as specified and directed. Make: L&T /Havells/Siemens
S&F in repair flat sumersible three core copper pvc insulated industrial cable for sumersible of 10sqmm complete all as specified and directed. Make: Finolex /Havells/Polycab
S&F in repair flat sumersible three core copper pvc insulated industrial cable for sumersible of 16sqmm complete all as specified and directed. Make: Finolex /Havells/Polycab
S&F motor protection relay incl single phase prevention, dry running motor, under current, over current phase reversal protection type MPRD2 complete all as specified and directed. Make: L&T / Minilec/ Legrand
S&F voltage protection relay incl adjustable setting & protection of unbalance, phase failure, under voltage, over voltage type VMRD2, complete all as specified and directed. Make: L&T / Minilec/ Legrand
Taking down water level controller type automatic, any type and S&F of range 450m, voltage 170-250V, frequency 50-60 Hz, dimensions 21.4cm x 12.5cm x 4cm, weight 100gm, brand Aqua Brim material plastic colour black complete all as specified and directed. Make: Aqua Brim or equivalant
SWAMI CONSTRUCTION
m/s anil traders
Mukesh Enterprises
m/s A.A brothers
M/s KKPARASHAR
M/S Rakesh Verma
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .