Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAccepted-AOC KARNATAKA | RAICHUR | KARNATAKA | 584123 | ₹6.7 Cr | L1 | Accepted-AOC Being found lowest L1 and reasonable |
| 2 | L2₹7.3 Cr+₹59.1 L (8.83%)Rejected-Finance | ₹7.3 Cr+₹59.1 L (8.83%) | L2 | Rejected-Finance Rejected being not lowest |
| 3 | L3₹7.6 Cr+₹93.9 L (14.0%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹7.6 Cr+₹93.9 L (14.0%) | L3 | Rejected-Finance Rejected being not lowest |
| 4 | L4₹9.9 Cr+₹3.2 Cr (47.3%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹9.9 Cr+₹3.2 Cr (47.3%) | L4 | Rejected-Finance Rejected being not lowest |
Tender Value
₹7.0 Cr
EMD Value
₹6.7 L
Closing Date
3 Mar 2025, 6:00 pmClosed
HQ CHIEF ENGINEER AIR FORCE ZONE UDHAMPUR
HQ CHIEF ENGINEER AIR FORCE ZONE UDHAMPUR
PROVISION OF DEFICIENT MD ACCN FOR AIRMEN AT AF STATION UDHAMPUR
2025_MES_693275_1
CEAFU-15/2024-25
Open Tender
Civil Works
Lump-sum
547 days
UDHAMPUR
AS PER TENDER DOCUMENTS AND POLICY INVOGUE
9 documents required · 9 mandatory
₹3,000
GE AF UDHAMPUR
₹6.7 L
Yes
UDHAMPUR
3 Jul 2025
15 Jan 2025
10 Mar 2025
15 Jan 2025
3 Mar 2025
17 Feb 2025
16 Jan 2025 - 24 Jan 2025
27 Jan 2025
Amount
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II (Demolition nad Dismantling )
Total amount of Sch 'A' PART-III (Section-I) ( Internal water supply works)
Sch 'A' PART-III ( Section-II) (Internal water supply works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F 15 mm bore bib cock Two way ,cast copper alloy , chromium plated with wall flange ,fancy type complete all as specified and directed
S&F 15 mm bore CP mixer For WHB cast copper alloy fancy type with provision for Hot & Cold, screwed For iron pipe or brass ferrule and fixed complete all as specified and directed
S&F Sink Cock with regular swinging spout 15 mm bore cast copper alloy , chromium plated complete all as specified and directed
S&F 15 mm bore bib cock ,cast copper alloy , chromium plated with wall flange ,fancy type complete all as specified and directed
Supply & Fixing 15 mm bore Brass Wall Mixer ( 2 in 1) for mixing hot & cold water screwed down for iron pipe including all fittings and flange,etc. complete all as specified & as direcetd.
S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed .
Total amount of Schedule 'A' PART-III (Section-II) (Internal water supply works)
Total amount of Sch 'A' PART-IV (SECTION-I) ( INTERNAL ELECTRIC SUPPLY WORKS)
Sch 'A' PART-IV ( Section-II) ( INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S & F modular type 6 Amp 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
S & F modular type 6 Amp 2-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
S & F modular type 16 Amp 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
S & F modular type 2/3 pin combined shuttered type 6 Amp socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
S & F modular type 2/3 pin combined shuttered type 16 Amp socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
S & F modular type 20 Amp 1P MCB with socket, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 complete all as specified and directed by Engineer-in-Charge.
S & F MCB ,32 A, 230 V, 50 Hz, 2P MCB ('B' curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB ,16 A, 230 V, 50 Hz, 2P MCB ('B' curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F 20 W surface / wall mounted LED batten capable of delivering 2100 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge.
S & F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 10W, system efficiency not less than 100 lumen / watt, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation Class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor >0.95, THD <20% as per IEC 61000-3-2, colour temp-6500K, surge protectioin 2.5 KV, 50,000 burning hrs (min) as per L70 criteria, two sgates isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM 70 & LM 80 certification.
S & F LED round surface mounted LED fitting aluminium housing, 12 watt, for operating volgage between 120V to 300V, system efficiency not less than 100 lumen / watt, PF-0.95 minimum, IP 20 protection, 5700CCT(K), CRI between 80-85, confirming to LM 79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs complete all as specified and as directed by Engr-in-charge.
S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep, 1325 RPM with, blades, and frame and louvers complete all as specified and directed by engineer-in-charge.
S & F modular type 1 module RJ-11 telephone scoket with shutter complete all as specified and directed by the engineer in charge
S & F modular type 1 module RJ 45 co-axial type TV socket all as specified and directed by the engineer in charge
M&L for Design ,supply and Install (DCU) data concentrator RF based unit for the 17 Nos of smart meters for the real time data metering data such as consumption of energy,any critical evenets/faults ,power consumption etc along with complete display unit with supporting infra like suitable battery back up / chargers /saftey device etc complete all as specified and directed by engr in charge.
Total amount of Sch 'A' PART-IV (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)
Total amount of Sch 'A' PART-V (SECTION-I) ( ROAD/PATH/CULVERT AND HARD STANDING ) )
SCHEDULE `A' PART-V(SECTION-II) ( ROAD/PATH/CULVERT AND HARDSTANDING) ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Material & Labour for making of central line/ edge line rad marking over speed breaker over bituminious pavement roads using thermoplastic limit (as per ASTM D36/Bs-3262-Part-l as approved by GE) (Hot application) white/yellow indigenous modern propelier road marking machine with single coat of 2.5mm thk as directed by Engr-in-charge including cost and conveyance, all ingredients such as binder, glassbeads, titanium dioxide, calcium carbonate, inters pillars, pigments as per MORTH specification of clause 803.4.1.2/ table 800-9 for the preparation of thermo plastic requirements the glass beads (Type-ll) confirming to MORTH specification clause 803.4.2.3 be sprayed at the rate of 250 gms/ sqm in succession the rate to include cost of all other materials labour charges for mixing the ingrediants to the required temperature, cleaning the road surfaces, pre marking cautionery sign boards, red flags, traffic cans as per traffic rules, safeguarding the newly painted centre line marking complete all as specified and directed.
Total amount of Sch 'A' PART-V (SECTION-II) ( ROAD/PATH/CULVERT AND HARDSTANDING)
Total amount of Sch 'A' PART-VI (SECTION-I)( SEWAGE DISPOSEL )
Sch 'A' PART-VI ( Section-II) ( SEWAGE DISPOSEL ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M&L for Construction of Soakage Wells size 1.8 M dia 3. 0 M effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M25 concrete including intercepting chamber and sceen chamber made of Brick masonary in CM 1:4, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified and directed . (TD DRG CEAF/STD-15/2000 Sheet 1/2 to 2/2 )
M&L for Construction of Conventional type RCC Septic tank 100 Users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as specified and as directed.(TD DRG CEAF/STD-15/2000 Sheet 1/2 to 2/2 )
Total amount of Sch 'A' PART-VI ( Section-II) ( SEWAGE DISPOSEL )
Total amount of Sch 'A' PART-VII ( AREA DRAINAGE )
Total amount of Sch 'A' PART-VIII (FENCING AND GATE )
Total amount of Sch 'A' PART-IX (SECTION-I) (FIRE FIGHTING SYSTEM)
SCHEDULE `A' PART-IX (SECTION-II) (FIRE FIGHTING SYSTEM) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and Install Booster pump 36 meter head discharge 900 LPM and 3.5 Kg per Sq Cm residual pressure and provision of MS sheet covering for motors with support of 40x40x5 mm angle Iron legs, PCC foundation for motor 415 Volts , 50 Hz, 3 phase including welding work all fittings such as nuts , bolts, washers and rubber gasket etc complete in all respect all as specified and as directed.
M&L for Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed.
S&F signages made out of 3mm thick opaque PVC board with computer cut, PVC non-reflective of size 150mm x 600mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the ‘LIFT / STAIRCASE’ by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5m from the finished floor level complete all as specified and directed
S&F signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective of size 300mm x 150mm reading “FIREPOINT” in 12.5 mm block letter in Green and white background, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2m from the finished floor level complete all as specified and directed
S&F emergency light LED exit signage wall mounted with inbuilt driver LED 2.2 Watt IP-20 operates on voltage 220-2404,50 Hz with lithium based battery to provide 3 hours back up all as specified and directed
Supplying, Installation, testring & commissioning talk back slave station in surface / recess suitable for operation on simplex mode complete with PTT knob & speaker / microphone enclosed in a MS (16 SWG) / ABS box with break glass in front all as specified and directed.
M&L for smoke zero halogen (LS0H) flame retardant fire alarm cable conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, 2 core 1.5 mm2 cable drawn through concealed steel conduit and having plain annealed stranded copper conducto with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 0C to 70 0C and minium bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of FM approved and UL listed microprocessor-based, true peer-to-peer neteorkable, Single loop addressable fire alarm control panel (FCAP) with its own microcontroller memory, communication module, fire device loop interface cards for intelligent initiating and indicating devices and peer-to-peer networkable with other addressable fire alarm panels. Conforming to UL 2572 mass notification system & NFPA 72, with required accessories complete all as specified and directed by engineer-in charge. NOTES : The FACP shall meet following specification/ functional requirement. (i) The FACP shall have one isolated intelligent Signalling line circuits (SLCS) capable of connecting up to 99 detectors and 99 modules per SLC upto 200 detector and 200 modules. (ii) The FACP shall have a degrade mode and the loops shall work in degrade mode in case of the CPU failure. (iii) The FACP shall have 640 character LCD backlit display/touch screen display, full QWETRY program keypad, LED indicatorviz power, fire alarm, supervisor, system trouble, other event signals silenced point disabled CPU failure; controls active etc membrane switch controls viz acknowledge signal silence, drill system, reset lamp test etc. (iv) The FACP shall have four access levels flash EPROM 240 VAC power supply automatic battery charge, 24 V sealed lead acid batteries, sufficient for 24 hrs normal working and 30 min in alarm condition. (v) The FACP shall have manul sensitivity adjustment up to nine levels, built-in alarm trouble security and supervisory relays, history file with 4000-event capacity in non-volatile memory plus separate 1000-event alarm-only file, keypad operation, LCD unit to indicate fire/fault signal of individual unit, in built printer to log all incoming data etc. (vi) The FACP shall have integrated 8 channel digital voice evacuation system controller capable of broadcasting evacuation message on the same peer-to-peer network, fire fighter’s telephone two-way communicationsystem capable of supervising all the speaker circuit with adequate zone control and accessories etc. NOTES : (a) The FACP shall be serviceable by any system integrator & shall not hgave dependency on specific system integrator. (b) The FACP shall have feature to “edit” & Dlete” field devices like detectors & modules without dependency on PC/Software/special tool/dongle.
S and F Fire Extinguisher ISI marked ABC Powder type multipurpose 4 Kg complete all inclusive with standard fittings,Hose,Pressure guage and accessories complete in all respect with wall mounting arrangement complete all as specified and directed.
S and F Fire Extinguisher ISI marked CO2 Type 3 Kg suitable for Class B and C fires complete all inclusive with standard fittings,Hose,Pressure guage and accessories complete in all respect with wall mounting arrangement complete all as specified and directed.
S and F fire stand along with 4 buckets made out of alloy steel duly painted in bright red colour and marked with fire logo all as specified and directed.
Total amount of SCHEDULE `A' PART-IX (SECTION-II) (FIRE FIGHTING SYSTEM)
Total amount of Sch 'A' PART-X (LIGHTNING PROTECTION)
Total amount of Sch 'A' PART-XI (TV CONDUIT)
Total amount of Sch 'A' PART-XII (LIFTS)
Total amount of Sch 'A' PART-XIII (HOT WATER SUPPLY)
Total amount of Sch 'A' PART-XIV ( SECTION-I)(EXTERNAL WATER SUPPLY)
SCHEDULE `A' PART-XIV (SECTION-II) (EXTERNAL WATER SUPPLY) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply, installation, testing and commissioning of LT Feeder Pillar outdoor type confirming of IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 ) , totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15 mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 56 with pre-treatment through 7 tank hot chemical process prior to powder coated powder coated with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface complete and comprising of the following: (A) Bus Bar (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs. B. INCOMER (i) MCCB Cap 63 Amp, 4 pole, 415V, 50 c/s confirming to IS:13947(Part-3) 1993, 25 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos
Supply, Installed Testing and Commissioning Altoch chlorine dosing system consisting of 100 litres PE /FRP tank with PE / FRP lid and level gauge along with Agitator (1280 RPM) pump complete set (Hypo Chlorine chemical dosing System) incl chemical supply line & injection points & power of motors (AC Induction motor) with Gear box, 230V, 120 watt, 1280 RPM, 50HZ, panels are integrated with shaft and blade (FRP / Epoxy coated) plastic mounted on tank lid having port hole for pouring Altoch and water as required. Lid having provision for mounting Dosing pump on lid Agitator motor 90 watts, 1440 RPM 230V, 50 HZ, 0.2 Amps and having speedcontroller to reduce speed upto 800 rpm Electronic solenoid operated pumps, interconnecting tubing / piping, mixing tank 100 ltrs with mixture / agitator & instruments like pressure gauge, pressure switch, pressure transmitter, ORP Sensor, with granuals (Altoch GP) 45 kg,Chlorine sensor , PPM valve display , duly mounted on structure frame with Agitator support including suction and drain out pipe connection with valve complete fixing accessories complete set all as specified and directed by Engr-in-Charge. (Make:- DECLIBAC / UNITED ENGINEERING / POTER & WATT CORP / BRIOZING UNLIMITED).
M & L for Valve pit chamber internal dimension of 900 x 900 x 750mm built in brick masonry in cement mortar (1:6) including waster concrete PCC (1:4:8) mixed type D2 100mm thick. Plastering to brick work cement mortor 1:6. 15mm thick internally and externally including provision of 3.15mm thick MS sheet cover fixed with angle iron frame of size 50x50x6 abandon in PCC 1:2:4 mixed type B-1 including copying of 100mm thick with PCC 1:3:6 type C2 painting to steel and iron work two coat of synthetic enamel paint over one coat of red oxide of primer necessary earth work and excavation in any type of soil complete with locking arrangement all as specified and directed by Engineer-in-Charge.
S & F Cast iron air release valves with two air outlets, 50mm bore and fixing Up in cast iron water supply mains of size 100 mm dia complete all as specified and directed.
S & F GRP ( Glass reinforced Plastic) Panel Tank made up of panel having 30 % Glass content, 30 % isophthalic unsaturated polyester resin, 40 % Filler content , panel thickness 5-16 mm, 2 m tank height having bending strength more than 100 MPa, 304 grade stainless steel bolts, nuts, tie rod and ladder all as per IS 14399 Part 1 & 2: 1996 and of capacity minimum 11000 liter and HDG Pedestal grillage in foundations, for supporting 11000 liter tank to be installed as per OEM specification in order to cater for 11000 liter GRP panel tank complete all as specified and directed
S&F mono block pump with motor set of capacity 3.7 KW /5 HP power rating, 515 KDI , Three phase, 415 Volts , size 50mm x 80mm, 3000 RPM, 31- 60 Mtr head with super enamelled copper conductor of standard size including varnish, insulation paper and tape including, as per site requirement all fixing accessories nuts, bolts, washer and provision of MS sheet covering for motors with support of 40zx40x5 mm angle iron legs, PCC foundation for motor etc complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/ KSB
Total amount of SCHEDULE `A' XIV (SECTION-II) (EXTERNAL WATER SUPPLY)
Total amount of Sch 'A' PART-XV ( Section I) (EXTERNA LELECTRIC SUPPLY)
Sch 'A' PART-XV ( Section II) (EXTERNA LELECTRIC SUPPLY) (External water supply) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F LT cable junction box outdoor shall be made out of polycarbonate with glass fiber reinforced then 205mm x 255mmx112mm ( the cable size upto 25sqmm) . The polycarbonate junction box shall be enviroment friendly, recyclable, halogen and silicon free, anti acid & anti corrosive . The junction box shall be rated for degree of ingress protection IP 66 in accordance with IEC 60529. weather proof , UV resistant. The gasket material of junction box shall be polyurethane and the gasket shall be internally embeded. The junction box shall be complies with requirement of the standards IEC 60998. The junction box with 25Amp connectors or terminal Trip or bus bar . The junction box / Enclosure shall be tested as per IEC including one No 4 pole connector and chlomium plated clamps and nuts, bolts, cable glands with lock nuts of 2 Nos for each box complete all as per menufacturer complete all as specified and directed. Make: Cat part No. KF2525B of Hensel / Siemens / Legrand / GE Power.
S&F LED avaiation light luminaires ,integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including connecting electricaly to location using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required and directed by Engr-in-Charge.
Supply, installation, testing and commissioning outdoor type LT cubical panel factory fabricated CRCA sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amps duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators .The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched / tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 3.15 mm . The auxilary support of SPD ( surge protation device) protected shall be provided, CPRI approved. Note:-Design / Drawing of L.T Panel shall be approved by Garrison Engineer, INCOMING: (a) Copper Busbar 4 pole (three phase and one for neutral) suitable for 400 Amps . (b) MCCB Cap 200 Amp, 4 pole, 415V, 50 c/s 36 KA-01 No . ( Note: LT panel board should be as per IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 )
Supply, installation, testing and commissioning indoor type LT cubical panel factory fabricated CRCA sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 2.00mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amps duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators .The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched / tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 2.00 mm . The auxilary support of SPD ( surge protation device) protected shall be provided, CPRI approved. Note:-Design / Drawing of L.T Panel shall be approved by Garrison Engineer, INCOMING: (a) Copper Busbar 4 pole (three phase and one for neutral) suitable for 400 Amps . (b) MCCB Cap 125 Amp, 4 pole, 415V, 50 c/s 25 KA-01 No . ( Note: LT panel board should be as per IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 )
Supply, installation, testing and commissioning outdoor type LT cubical panel factory fabricated CRCA sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amps duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators .The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched / tied, ferruled for proper identification and crimpled with adequate size of lugs. The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 3.15 mm . The auxilary support of SPD ( surge protation device) protected shall be provided, CPRI approved. Note:-Design / Drawing of L.T Panel shall be approved by Garrison Engineer, INCOMING: (a) Copper Busbar 4 pole (three phase and one for neutral) suitable for 400 Amps . (b) MCCB Cap 100 Amp, 4 pole, 415V, 50 c/s 25 KA-01 No . Note: LT panel board should be as per IS / IEC 61439-I: 2011& IS / IEC 61439 -2: 2011 )
M&L laying well burnt old size Fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supply and Fix CI cable route indicators of appropriate size including excavation and PCC foundation work complete all as specified and directed by Engineer in Charge.
Total amount of Sch 'A' PART-XV ( Section II) (EXTERNA LELECTRIC SUPPLY)
Sch 'A' PART-XVI(DG SET) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply,install ,testing, commissioning of 'Silent type' diesel generating set alongwith having prime power rating of 40 kVA/32 kW,415Volts at 1500RPM , 0.8 lagging power factor at 415 volts suitable for 50 hz 3 phase system and for 0.85 load factor ,CPCB-IV /latest norms complied, acoustic enclosure,realy panel for automatic starting on main failure(AMF), anti vibration mountings,control panel and foundation.The DG set should be robust in construction factory tested and assembled to ensure perfect alignment of Engine and Alternator on a common base frame.The DG set power rating indicated above is inclusive of altitude correction factor however the DG Set shall be designed and suitable to operate as per tropical condition of Udhampur Area and for more details on service condition refer particualr specification.The DG set shall be comprising of following item as under:- (a)Diesel Engine : The diesel engine shall be of four stroke cycle multi-cylinder,direct injection water cooled, turbo charged with after cooler, Air to air aftercooling and optimised turbocharger for increased altitude capabilities developing required BHP/KW @ 1500 rpm for a 40 KVA Alternator under NTP condition of BS 5514/ISO 3046 with an over load capacity of 110% for one hour in any specified 12 hrs of continuous operation,suitable for generating set application on AMF mode.The engine shall confirm to IS:10000/BS:649/BS 5514/ISO 3046The engine shall have the following accessories: Cooling fan and radiator. DM water cooling systems with pre-mix anti-corrosive additive Turbocharger. Fly wheel with fly wheel housing. Electrical engine starter motor (disengagement after start-up) with Batteries. Battery charging systems. Stainless steel exhaust flexible elbow. Thermal sealing of exhaust pipe and aluminium cladding for complete exhaust pipe and silencer. Required filters for fuel, lube oil, air etc. Sets of flexible hoses as required. Suitable rubber coupling to Alternator with guard. Suitable Engine controller for protection of the engine. Coolant heater and crankcase heater. Oil drain Pump. Heavy duty air cleaner. (c)Starting system :The engine starting shall be by means of totally enclosed axial type electric starter suitable for 12volts/24 volts DC starting system comprising of starter motor, voltage regulator and arrangement for initail exciation complete with suitable number of batteries(25 plates, 100AH Sealed Maintenance Free (SMF) Lead-Acid type) as required as per specifications.The battery shall be supplied with a suitable floor mounted MS stand treated with seven tank treatment, two coats of red oxide /primer & acid resistant paint.with wooden base, adaptor box etc . with copper conductor battery leads of required length and socket/clamps
Item 27.03 Cont..(d ) Alternator :40 kVA 3 phase 0.8 PF 415V, 4 wire 1500 rpm self-excited and self regulated through AVR confirming to IS :4722/BS 2613 suitbale for tropical condition with brush less exciter, housed in screen protected drip proof enclosure. The alternator shall be confirming to IS 13364 Part-2 & IS 15999 Part-1/ IEC 60034 Part-1 capable of delivering rated output at rated power factor with,a. Terminal voltage differing from the rated value by not more than +/- 5%. b. Frequency differing from the rated value by not more than +/-0.5%. c. Short circuit capacity of 300% for 10 seconds. d. Over load capacity of 110% for one hour. The insulation class of the Alternator shall be class F/ H. The temperature rise shall be limited to class B and Ingresses enclosure protection shall IP23 or better. The alternator shall be fitted with suitable Nos. Resistance Temperature Device (RTD) & Bearing Temperature Device (BTD) along with space heaters. (e) Alternator Protection :Alternator should have following protections Over and Under voltage Under and Over frequency warning and trip Loss of excitation Over current and Earth Fault and Short Circuit Protection Unbalanced loads Restricted Earth Fault Protection. Differential protection. Diode Failure. (f) Voltage regulator :A rapid response voltage regulator shall be provided to regulate the generated voltage.The overall regulations from no load to full load, including cold to hot variation and load power factor of 0.8 lag to unity shall be within 2% of the normal voltage. The excitation system shall be designed to promote rapid voltage recovery following sudden application and disconnection of load. (g) Acoustic enclousure : The acoustic enclosure should be supplied along with DG set from the manufacturer outlet itself as per CPCB-IV norm.Acoustic enclosure shall be of powder coated and fabricated out of 2mm thick CRCA MS sheet. The canopy shall have four hinged doors, one door with glass window to view proper parameters on the control panel. The canopy and doors shall have inside lining of fire retardant foam/glasswool as acoustic materials. The base frame shall be fabricated in ISMC channel or in sheet metal, with lifting hooks for convenient lifting of complete set i.e. along with canopy, engine and alternator. The sound level shall have less than 75 db (A) at a distance of 1 meter.High quality noise absorbant and fire-retardant grade acoustic Insulation material (P.U. Foam) complying to IS 8183. The allowable temperature raise inside the canopy is 5 to 7 deg. Centigrade. The Measurement of noise should be as per ISO 3744/ ISO 8528 (Part 10) standard.The canopy has the provision of emergency push button, external to the canopy
Item 27.03 Cont.. (xii)Indicating Lamps for Load on mains,Load on D.G. Set,Low lube oil pressure and High water temperature (xiii)Suitable size of Tinned Copper bus bar will be provided with current density of 1.2 Amp per mm².(xiv) Set of relays and contractor of suitable capacity with MCCB, 4 pole, OF suitable Amps ratings , 415 Volt. KA for automatic start & automatically shut down of DG set or as per manufacturer recoomendation of suitable rating & capacity - 02 Nos. (xv) By pass arrangement by providing on laod change over switch of suitable rating in Amps 4 pole to be installed with AMF- 01 Nos. Note : 1.AMF Panel shall be installed outside the acoustic enclousre (ii) LT Cable of suitable rating from DG set Alternator output to Automatic main failure panel (AMF panel) should be provided by the contractor .(iii) Cost of DG set foundation deemed to be included in cost of item.(iv) Contractor should submit necessary drawing to GE/Engr-in-Charge before placing the order.
Total amount of Sch 'A' PART-XVI(DG SET)
Total amount of Sch 'A' PART-XVII(Site clearance, excavation & earth works)
Total amount of Sch 'A' PART-XVIII (Sanitary/Plumbing Work)
SCHEDULE `A' PART-XIX (Operation of Lifts and AMC ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Phase-III : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
Phase-IV : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
Phase-V : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
Phase-VI : Annual Maintenance contract of lift 13 passenger installed at Air Force Station Udhampur. The AMC will cover following works related to the lift (a) All the lift parts which get damaged during the operation will be repaired / replaced during this period from the OEM. (b) AMC will cover routine service of the lift once a month by oilling, cleaning, dusting, gresing, checking all the eletrical and mechanical parts and all the services as scheduled and required by OEM for the lifts (c) The contractor shall enter into MOU with the OEM for the provision of further maintenance post warranty/ defect liability period. (d) Any type of complaints in the lift shall be attended within time as specified in PS. (e) MOU between contractor and OEM shall be submitted at least six months perior to the issue of completion certificate of the main contract. (f) Penality for not attending complaints as sepcifed in PS.
Phase-VII : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
Phase-VIII : Annual Maintenance contract of lift 13 passenger installed at Air Force Station Udhampur. The AMC will cover following works related to the lift (a) All the lift parts which get damaged during the operation will be repaired / replaced during this period from the OEM. (b) AMC will cover routine service of the lift once a month by oilling, cleaning, dusting, gresing, checking all the eletrical and mechanical parts and all the services as scheduled and required by OEM for the lifts (c) The contractor shall enter into MOU with the OEM for the provision of further maintenance post warranty/ defect liability period. (d) Any type of complaints in the lift shall be attended within time as specified in PS. (e) MOU between contractor and OEM shall be submitted at least six months perior to the issue of completion certificate of the main contract. (f) Penality for not attending complaints as sepcifed in PS.
Phase-IX : OUTSOURCING OF SERVICES FOR OPERATION OF LIFTS INSTALLED AT DEF MD ACCN G+4 BLDG AND ITS EQUIPMENTS BY PROVIDING THREE ELECTRICATION/ SKILLED OPERATORS FOR ROUND THE CLOCK OPERATION IN THREE SHIFT EACH SHIFTS PER DAY 8 HOURS INCUDLING SUNDAY AND HOLIDAY INCLUDING DAILY CLEANING OF EQUIPTMENTS / INSTALLATIONS/ PROVINDING T&P AND ALL OTHER TOOLS REQUIRED FOR SMOOTH FUNCTIONING OF LIFT INCL PROVIDING AND MAINTANING DAILY LOG SHEET. NOTE : (i) ELECTRICIAN / LIFT OPETAROR HAVE FIVE YEARS EXPERINCE OF ELECTRICAL EQUIPMENTS, OPERATION COMPRISING OF LIFT OPERATION OF KNOWLEDGE OF HUMAN OPERATION DRIVE AUTOMATIC RESQUE DEVICE, DOOR SENCER, EMERGENCY EXIT ETC. (ii) MAINTAIN DAILY LOG SHEET. (iii) OPERATOR WILL NOT LEAVE THE INSTALLATION WITHOUT PROPER HANDING TAKING WITH NEXT SHIFT OPERATOR. (iv) COST OF RELIEVER DEEMED TO BE INCLUDED ABOVE QUOTED RATES (v) OPERATOR HAVE KNOWLWDGE OF OPERATION OF EQUIPMENTS INSTALLED AT LOCATION DEPLOYED (vi) A PANEL RECOVERY OF 1000 PER SHIFT PER OPERATOR SHALL BE RECOVERED IN ADDITION NO PAYMENT FOR THE SHIFT IN CASE OF OPERATOR FOUND ABSENT FROM THE DUTY
Phase-X : Annual Maintenance contract of lift 13 passenger installed at Air Force Station Udhampur. The AMC will cover following works related to the lift (a) All the lift parts which get damaged during the operation will be repaired / replaced during this period from the OEM. (b) AMC will cover routine service of the lift once a month by oilling, cleaning, dusting, gresing, checking all the eletrical and mechanical parts and all the services as scheduled and required by OEM for the lifts (c) The contractor shall enter into MOU with the OEM for the provision of further maintenance post warranty/ defect liability period. (d) Any type of complaints in the lift shall be attended within time as specified in PS. (e) MOU between contractor and OEM shall be submitted at least six months perior to the issue of completion certificate of the main contract. (f) Penality for not attending complaints as sepcifed in PS.
Total amount of SCHEDULE `A' PART-XIX (Operation of Lifts and AMC )
NOTE: Amount against schedule of credit of Rs.4960.00 for retrieved materials mentioned under relevant part XIX of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during acceptance of tender.
mohan lal gupta sons (BID ID -3254224)
SHIVAE CONSTRUCTION (BID ID -3248002)
vijay builders (BID ID -3247909)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .