| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.9 LAccepted-AOC | ₹58.9 L Quoted ₹59.6 L | L1 | Accepted-AOC AGREEMENT ACCEPTED |
| 2 | L2₹60.7 LRejected-Finance | ₹60.7 L | L2 | Rejected-Finance SECOND LOWEST TENDERER L2 |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-INSUFFICIENT DOCUMENTS. |
| Sl No | Description | Qty | Unit | balan electrical works L2 | RR AND Co L1 |
|---|---|---|---|---|---|
| 1.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End | 4 | Pts | 2,800 ₹11,200 | 2,415 ₹9,660 |
| 2.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with suitable Module GI switch box on wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Plug point ( 8 points / Coil) Higher End | 4 | Pts | 1,996 ₹7,984 | 2,000 ₹8,000 |
| 3.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End | 263 | Pts | 2,985 ₹7.9 L | 3,000 ₹7.9 L |
| 4.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End | 36 | Pts | 2,519 ₹90,684 | 2,500 ₹90,000 |
| 5.00 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb | 25 | Nos | 701 ₹17,525 | 700 ₹17,500 |
| 6.00 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (HigherEnd)complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. | 86 | Nos | 1,100 ₹94,600 | 1,100 ₹94,600 |
| 7.00 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End)complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube. | 24 | Nos | 1,450 ₹34,800 | 1,500 ₹36,000 |
| 8.00 | Supply and fixing of 4 Feet LED Twin 20W Fitting with LED 20W tube (Higher End)complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube. (Data-1) | 12 | Nos | 1,782 ₹21,384 | 1,800 ₹21,600 |
| 9.00 | Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. | 13 | Nos | 1,733 ₹22,529 | 1,700 ₹22,100 |
| 10.00 | Supply and fixing of 18W LED Square type Surface mounted LED fitting (Higher end) on Ceiling with PVC unsheathed copper leads from terminals to the fitting. | 5 | Nos | 2,250 ₹11,250 | 2,300 ₹11,500 |
Tender Value
₹58.9 L
EMD Value
₹39,500
Closing Date
25 Feb 2026, 3:00 pmClosed
Superintending engineer
Office of the Superintending Engineer, PWD., Building Construction and Maintenance Circle, Thanjavur-1
Providing Internal and External Electrification Lift and EB Service Connection charges to the Construction of New Taluk Office Building at Kurinjipadi
2026_PWD_662179_1
90-01-2025-2026
Open Tender
Electrical Works
90 days
Kurinjipadi
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹39,500
17 Jun 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
25 Feb 2026
20 Feb 2026
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with suitable Module GI switch box on wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Plug point ( 8 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb
Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (HigherEnd)complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.
Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End)complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube.
Supply and fixing of 4 Feet LED Twin 20W Fitting with LED 20W tube (Higher End)complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube. (Data-1)
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 18W LED Square type Surface mounted LED fitting (Higher end) on Ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 24 W LED 2 x 2 square type Surface mounted fitting (Higher end) with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod with 12 mm MS Rod bent to U shaped as fan clamp in Concrete roof
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting
Supply and fixing of 300mm (12") sweep (lightduty) AC exhaust fan complete with necessary wall opening and making good of the wall
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan.
Supply and fixing of AC/DC 76 mm buzzer/call bell suitable for 230 volts 50 c/s single phase Ac supply with push switch on suitable concealed Box (GI) in flush with wall with connections.
Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 32 A 4P MCB as incoming and 12 Nos 6A to 32A SP MCB as outgoing in flush with wall with Earth connection only. Higher End
Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 63A 4P MCB as incoming and 18 Nos 6A to 32A SP MCB as outgoing in flush with wall with Earth connection only. Higher End
Supply and fixing of 6 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board ( with MCB Incomer ) with double door (metal door) with 1 no. 125A 4P MCB switch as incoming and 4 nos. 63A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End
Supply and erection,testing, commissioning uninterrupted power supply OFFLINE (Sinewave) with copper wound Transformer of 2000VA with Input supply of 230V ,50Hz AC supply with 150 AH Tubular Battery to work at full load capacity including transportation with following specification. 1. Input Voltage : 230 , 50Hz single phase AC supply. 2. Output Voltage : 220V to 240V 50HZ AC supply 3. Battery charging device of Suitable rating 4. Circuit board of Suitable capacity 5. Over load and short circuit protection 6. Visual Indication for ON/OFF/ Trip/ battery charging / mains failure/ Low battery etc., 7. Mode setting for Bypass /Reset 8. 12V, 150AH battery -2 Nos. 9. Trolly for heavy UPS & Battery
Supply and fixng of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete
Supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with Earth connection only.
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion
Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.
Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.
Supply and Run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire with painting of suitable colour.
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed portion.
Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clarnping of 3 1/2 x 70 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3 1/2 x 70 sqmm PVC LTUG Aluminium armoured cable withnecessary aluminium cable sockets by crimping etc. with electrical connection complete
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no 10 persons passenger Gearless lift with Machine room ,speed : 1.5 m/sec with Stainless Steel Panel ,DisAble Friendly ,Microprocessor Based Controller ,VVVF Drive , Fire Rated Doors and ARD with the following Technical Specification 1.Location: Taluk Office, Kurinjipadi 2.No of lift: 1 No 3.Type of lift: passenger 4.Capacity of lift: 10 persons / 680 Kgs 5.Speed: 1.5 m / sec 6.Type of drive: VVVF drive with enhanced ride comfort and near zero level functions 7.No of floors: GF + 2 Floor 8.Total travel: 7.2 mtrs 9.Leveling accuracy: high level accuracy with smooth and jerk free stopping 10. Construction of CAR: No 4 hardened sheet high quality stainless steel car and hand rail granite flooring and Perspex false ceiling. 11. Position of machine: directly above the lift well. 12. No of landing service: one in the front side-3 no’s 13. No. of car entrance: one in the front side only 14. Car entrance door: power operated automatic VVVF drive center opening sliding SS door 15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings. 16.Lift well Size : 2300 mm (wide)x 1850 mm (depth)as per ISI 14665(part1) 2000 17.Lift pit depth:1600 mm 18. Car size: 1300 mm (width) x 135 0 mm (depth) as per IS 14665 (part 1 )2000, 19. Car clear opening: 800 mm wide x 2000 mm height as per IS 14665 (part 1)2000 20. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light.
21.Control: micro computer (micro processor):based simplex collective control with / without attendant 22. Car fittings: LED lighting with 1 no 300 mm sweep cabin fan. 23. Lift well: Already Existing 24. Indication: UP / DOWN digital direction and position indicator for all landings and inside the car. 25.Emergency alarm bell: battery operated bell to be provided with automatic charging device 26.Emergency light: battery operated light to be provided with automatic charging device 27.Fire mans switch: to be provided at the GF 28. Minor builder works: to be provided by the lift contractor. 29. Scaffoldings: to be provided by the lift contractor. 30. Sill angles and fascia plates: SS to be provided by the lift contractor. 31. Steel for lift machinery: to be provided by the lift contractor. 32. Servicing and maintenance: Comprehensive servicing and maintenance of lifts for further period of two years beyond free warranty period of one year from the date of commissioning of lifts will be paid at the rate of 5% of capital cost of lift. 33. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories. 34. Provision for intercom with phone: to be provided by the lift contractor. 35.Lift license: preparation of drawings payment of charges to CEIG and insurance policy if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor
36. Floor position announcer: to be provided by the lift contractor. 37.Special features a) Infra red door sensor with full height screen b) Full width rear panel mirror c)Tubular SS hand rail in car d) Stainless steel signal features e) Vandal proof SS button with SS cover f) SS door frames for landing doors g) V3F door operator h) Call register signal i) Stainless steel fascia plates for car operating panel and landing fixtures j) Steel ladder for lift machine room k) On / off switch for fan and light l) Over load warning indicator with audio announcer m)Voltage stabilizer for control circuits n)Braille button o) Granite flooring provided by the lift contractor 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year. 43. Disable Friendly Feautures 44. 2 Hours Fire Rated Doors
Supply, Erection, testing and Commissioning of 2.0 TR (6000K cal / hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Non CFL compressor operating on refrigerant suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with three Star rating as per BEE Specification Five Star Rated and capable of performing the following functions. (A) Cooling (B) Dehumidifying (C) Air Circulating. (D) Filtering.The installation work for the above split type AC units includes the following.1. Mounting / fixing indoor and outdoor units at their respective locations.2. Laying refrigerent pipe line of 6mtrs. Length, both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. 3. Installing the suction pipe with expanded polyurthelene foam 5mm thick tubing. 4. Laying 25mm dia flexible PVC drain pipe of 6mts. Length to drawn out the condensate water being formed in the indoor unit.
5. Leakage testing the entire gas unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided 3 core with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit.
Supply and fixing of 5 KVA voltage stabilizer (V guard /Eq.make ) suitable for 2.0 tons capacity split type air conditioner with 3 minutes time delay and low / high voltage cut off switch (wall mounting) with necessary wire connection.
Supply and laying of 5/8'' and 3/8'' copper pipe
Supply and Fixing of MS stand for fixing outdoor units.
Supply and fixing of 32A DP MCB in flush with sheet enclosure in flush with wall with earth connection
Supply and erection of GI Steel tubular pole for street light of 6 Metre Length Single Bracket Pole with Base Plate (250 x 250 x 6mm) 114.30mm OD x 5.40mm Thick x 4500mm Length, 88.90mm OD x 4.85mm Thick x 1500mm Length, 76.10mm OD x 3.25mm Thick x 1500mm Length with single arm ornamental bracket of outer dia 32 mm pipe bent suitably to give a height of 1.5 mtr and overhang welded suitably with ornamental bracket and fixed rigidly with 4 Nos of bolt and nuts to prevent any turning movement of bracket due to wind The pole should be hot dip galvanized confirming to BESN ISO-1461 with thickness of 65 Micron and fixed rigidly with 8 Nos of bolt and nuts to prevent any turning movement of bracket due to wind with sheet moulded compound (SMC) junction box IP 42 protection of size (225 mm x 150 mm x 100 mm) , fire proof of suitable size with 4 way terminal block with hylem sheet of size (225 mm x 150 mm x 6mm) with 1 No. 10A SP MCB with 1 No. suitable links provided at a height of 2.0 mtr from the ground level with embossing of metalic "DANGER 440 V" with earth connection with earth bolts of size 8mm x 25mm welded on the pole at one end with 2 mtr of 32 mm GI pipe for incoming and outgoing cable.
The pole shall be provided for coil earth with No. 8 SWG GI wire of 11.5 mtr of length in which 10 mtrs of total length compressed in to a coil of one meter length. The pole shall be painted with one coat of red oxide primer paint and two coats of aluminium paint of reputed make to the length of pole with supply and fixing of 1 No. 48 W LED Street Light Fitting with LED suitable for pole dia 63 mm (max)/ equivalent to be approved by PWD officials with necessary connection wire from junction box to the fittings with 3 x 2.5 sq mm (28/0.3 mm) PVC copper wire for each fitting with pole earthing with necessary connections testing and commissioning as per the specification. The GI steel tubular pole is to be embeded in the bridge with proper concrete pedestal and suitable clamping arrangements.
Supply and erection of GI Steel tubular pole for street light of 6 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 114.30mm OD x 5.40mm Thick x 4500mm Length, 88.90mm OD x 4.85mm Thick x 1500mm Length, 76.10mm OD x 3.25mm Thick x 1500mm Length with single arm ornamental bracket of outer dia 32 mm pipe bent suitably to give a height of 1.5 mtr and overhang welded suitably with ornamental bracket and fixed rigidly with 4 Nos of bolt and nuts to prevent any turning movement of bracket due to wind The pole should be hot dip galvanized confirming to BESN ISO-1461 with thickness of 65 Micron and fixed rigidly with 8 Nos of bolt and nuts to prevent any turning movement of bracket due to wind with sheet moulded compound (SMC) junction box IP 42 protection of size (225 mm x 150 mm x 100 mm) , fire proof of suitable size with 4 way terminal block with hylem sheet of size (225 mm x 150 mm x 6mm) with 2 No. 10A SP MCB with 1 No. suitable links provided at a height of 2.0 mtr from the ground level with embossing of metalic "DANGER 440 V" with earth connection with earth bolts of size 8mm x 25mm welded on the pole at one end with 2 mtr of 32 mm GI pipe for incoming and outgoing cable.
The pole shall be provided for coil earth with No. 8 SWG GI wire of 11.5 mtr of length in which 10 mtrs of total length compressed in to a coil of one meter length. The pole shall be painted with one coat of red oxide primer paint and two coats of aluminium paint of reputed make to the length of pole with supply and fixing of 2 No. 48W LED Street Light Fitting with LED suitable for pole dia 63 mm (max)/ equivalent to be approved by PWD officials with necessary connection wire from junction box to the fittings with 3 x 2.5 sq mm (28/0.3 mm) PVC copper wire for each fitting with pole earthing with necessary connections testing and commissioning as per the specification. The GI steel tubular pole is to be embeded in the bridge with proper concrete pedestal and suitable clamping arrangements.
Supply and fixing of IP65 post top 30 W LED gate light fitting on existing pillar and at the bottom of the pillar supply and fixing of MS box of 30cmx20cmx10cm with angle iron frame work with door and lock and key arrangements and supply and fixing of 1no 6A SP MCB inside the MS box with PVC unsheathed leads and painting of suitable color
Supply and laying of 2 x 10 sq.mm PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and laying of 2 x 10 sq.mm PVC armoured LTUG cable in suitable size GI pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clarnping of 2 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125 mm x 50 mm x 6 mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
Supply, erection, commissioning and testing of outdoor type Panel of suitable size with Channel support and with double door made up of 16 gauge MS sheet with lock and key arrangements finished with anti corrosive treatment and painting with view glass arrangements for meter with weather proof ventilation arrangements mounted on suitable concrete pedestal with cable entry holes with two coats of enamel paint with three independent compartments with the following provisions 1) 40A DP MCB - 1 no 2) 2 Pole Contactor - 1 no 3) Analog Timer - 1 no 4) Interconnection wiring
ADD GST 18%
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_794953.xls
BOQ • 0.40 MB
KURNIJIPADICON.pdf
Tender Documents • 1.59 MB
Download all tender documents and submit your bid