Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.6 LAccepted-AOC VPO DUMERKHA KALAN TEH NARWANA 126116 | DUMERKHA KALAN | JIND | HARYANA | 126116 | 1 | Accepted-AOC AOC | |
| 2 | 2₹32.1 L+₹1.5 L (4.95%)Rejected-Finance PLOT 411 GALI NO 9 GANDHI NAGAR GANDHI NAGAR 122001 | GANDHI NAGAR | GURUGRAM | HARYANA | 122001 | 2 | Rejected-Finance 2 |
| Sl No | Description | Qty | Unit | The V.K. Co-Operative Labour & Construction Society Limited L1 | THE JIYA CO-OPERATIVE LABOUR & CONSTRUCTION SOCIETY LIMITED L2 |
|---|---|---|---|---|---|
| 2.00Providing and fixing of 5 mtr pole, 9 mtr long high mast and erection of lights in various roads under ward 20 ,23 and 24 under zone 4 MCG. | |||||
| 3.00 | Supply and erection of 2.5 sqmm 3 core unard FRLS PVC insulated ISI Marked copper conductor cable complete as per entire satisfication of engineer in charge.Make RR / Havells / Polycab/Grandley. 2.5 Sq. mm 3 Core Cable. | 500 | Metre | 180 ₹90,000 Lowest | 182 ₹91,000 |
| 4.00 | Providing trench less boring below existing road / pavement including laying of 65 mm dia GI pipe B class required to complete the job in all respect | 10 | Metre | 860 ₹8,600 Lowest | 860 ₹8,600 Lowest |
| 5.00 | Restoring the road cut, in level with the existing road surface, including preparation of subgrade laying and relaying of soiling and laying and consolidation of wearing coats to water bound macadam specification and laying 20mm thick premix carpet, on top including cost of tack and sealcoat complete in all respects... | 50 | Sqm | 334 ₹16,700 Lowest | 334 ₹16,700 Lowest |
| 6.00 | Providing trench less cuttting by Hydraulic Drilling Device boring/ Manual OR through some suitable alternate method with insertion of HDPE Pipe including supply, Delivery of HDPE pipe at work site and laying of 50mm internal diameter HDPE pipe inside road for road corssing of cable by Hydraulic Drilling Device without opening of the road top surface, laid at a depth of at least 900mm below the road surface from the feeding point to the feeder pillar box in median (OR) from feeder pillar to respective street light pole including cost of all accessories for road crossing for laying of cables.. | 100 | Metre | 395 ₹39,500 Lowest | 395 ₹39,500 Lowest |
| 7.00 | Digging of pucca road in required width for laying of cable/pipe complete in all respect upto the entire satisfaction of Engineer-in-charge.. | 20 | cum | 274 ₹5,480 Lowest | 274 ₹5,480 Lowest |
| 8.00 | Supply, Erection, testing and commissioning of 3 phase automatic timer AMSON`s / L and T make on/off the street lights on different fixed timing maintainable on street lights pedestal, pillar, wall M.S pedestal where on\off point is available, cabinet is fabricated from 22 gauge, painting, wiring, connection on/off from bottom of the cabinet, 3 contractor 63 Amp, 24 volts D.C each transformer, rectifier system switching system, bakelite contractor 63 Amp, MCB 63 Amp LandT digital timer Auto/Manual system, time setter, fibber sheet, rubber and plastic component, wiring and component fitting, chemical (Epoxy) including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - In -Charge of the work. | 3 | Each | 18,000 ₹54,000 Lowest | 18,000 ₹54,000 Lowest |
| 9.00 | Buy Back Removing of Existing Pole / With bracket and Cable including exiting foundation dismantling with all labour and material required etc to complete the job in all respect up to the in entire satisfaction of Engineer-charge-of the work.... | 10 | Each | 2,500 ₹-25,000 Lowest | 2,500 ₹-25,000 Lowest |
| 10.00 | Erection Testing and commissioning of Three phase CCMS panel petty material required for installation of ccms panel i.e clamp,nut and bolts,thimble ,wire etc complete in all material required for installation on PCC pole or Pedstal. complete in all material required for installation on PCC pole or Pedstal. | 2 | Each | 2,000 ₹4,000 Lowest | 2,000 ₹4,000 Lowest |
| 11.00 | Providing and fixing of 4G/5G Sim Card and recharse fees per month for street lights CCMS panel Compelte in all respect required for proper operation of CCMS panel. 500 Nos x 60 | 192 | Each | 77 ₹14,784 Lowest | 77 ₹14,784 Lowest |
Tender Value
₹29.2 L
EMD Value
₹58,362
Closing Date
3 Jun 2026, 12:00 pmClosed
SACHIN YADAV
Municipal Corporation Gurugram
Providing and fixing of 5 mtr pole, 9 mtr long high mast and erection of lights in various roads under ward 20 ,23 and 24 under zone 4 MCG.
2026_HRY_524437_1
20265895830C F746 4C40 A378 28E1D3C5AEF2285ULB
Open Tender
Civil Works
Works
150 days
Gurugram
Providing and fixing of 5 mtr pole, 9 mtr long high mast and erection of lights in various roads under ward 20 ,23 and 24 under zone 4 MCG.
2 documents required · 2 mandatory
₹1,180
Yes
₹58,362
Yes
18 Jun 2026
26 May 2026
3 Jun 2026
26 May 2026
3 Jun 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Providing and fixing of 5 mtr pole, 9 mtr long high mast and erection of lights in various roads under ward 20 ,23 and 24 under zone 4 MCG. | - | - | - | - |
| 3 | Supply and erection of 2.5 sqmm 3 core unard FRLS PVC insulated ISI Marked copper conductor cable complete as per entire satisfication of engineer in charge.Make RR / Havells / Polycab/Grandley. 2.5 Sq. mm 3 Core Cable. | 500 | Metre | - | - |
| 4 | Providing trench less boring below existing road / pavement including laying of 65 mm dia GI pipe B class required to complete the job in all respect | 10 | Metre | - | - |
| 5 | Restoring the road cut, in level with the existing road surface, including preparation of subgrade laying and relaying of soiling and laying and consolidation of wearing coats to water bound macadam specification and laying 20mm thick premix carpet, on top including cost of tack and sealcoat complete in all respects... | 50 | Sqm | - | - |
| 6 | Providing trench less cuttting by Hydraulic Drilling Device boring/ Manual OR through some suitable alternate method with insertion of HDPE Pipe including supply, Delivery of HDPE pipe at work site and laying of 50mm internal diameter HDPE pipe inside road for road corssing of cable by Hydraulic Drilling Device without opening of the road top surface, laid at a depth of at least 900mm below the road surface from the feeding point to the feeder pillar box in median (OR) from feeder pillar to respective street light pole including cost of all accessories for road crossing for laying of cables.. | 100 | Metre | - | - |
| 7 | Digging of pucca road in required width for laying of cable/pipe complete in all respect upto the entire satisfaction of Engineer-in-charge.. | 20 | cum | - | - |
| 8 | Supply, Erection, testing and commissioning of 3 phase automatic timer AMSON`s / L and T make on/off the street lights on different fixed timing maintainable on street lights pedestal, pillar, wall M.S pedestal where on\off point is available, cabinet is fabricated from 22 gauge, painting, wiring, connection on/off from bottom of the cabinet, 3 contractor 63 Amp, 24 volts D.C each transformer, rectifier system switching system, bakelite contractor 63 Amp, MCB 63 Amp LandT digital timer Auto/Manual system, time setter, fibber sheet, rubber and plastic component, wiring and component fitting, chemical (Epoxy) including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - In -Charge of the work. | 3 | Each | - | - |
| 9 | Buy Back Removing of Existing Pole / With bracket and Cable including exiting foundation dismantling with all labour and material required etc to complete the job in all respect up to the in entire satisfaction of Engineer-charge-of the work.... | 10 | Each | - | - |
| 10 | Erection Testing and commissioning of Three phase CCMS panel petty material required for installation of ccms panel i.e clamp,nut and bolts,thimble ,wire etc complete in all material required for installation on PCC pole or Pedstal. complete in all material required for installation on PCC pole or Pedstal. | 2 | Each | - | - |
| 11 | Providing and fixing of 4G/5G Sim Card and recharse fees per month for street lights CCMS panel Compelte in all respect required for proper operation of CCMS panel. 500 Nos x 60 | 192 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
BOQ_603381.xls
BOQ • 0.28 MB
AD0165626.pdf
Additional Documents • 0.97 MB
OT0165626.pdf
Other Document • 0.97 MB
corr524437.pdf
PDF • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .