| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | ₹1.4 Cr | L1 | Accepted-AOC Accepted being lowest tenderer |
| 2 | L2₹1.5 Cr+₹10.2 L (7.15%)Rejected-Finance | ₹1.5 Cr+₹10.2 L (7.15%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹1.6 Cr+₹16.8 L (11.7%)Rejected-Finance 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | ₹1.6 Cr+₹16.8 L (11.7%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹1.9 Cr+₹51.9 L (36.3%)Rejected-Finance | ₹1.9 Cr+₹51.9 L (36.3%) | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
20 Aug 2021, 6:00 pmClosed
HQ Chief Engineer Pathankot Zone
HQ Chief Engineer Pathankot Zone Pathankot
PROVN OF TECH SHED OTM ACCN AND SWTs AT BIRPUR RATNUCHAK
2020_MES_405234_3
CEPZ-25/2019-20
Open Tender
Civil Works
Lump-sum
365 days
GE (P) Jammu
All as per tender documents
7 documents required · 7 mandatory
₹1,000
GE (P) Jammu
₹1.8 L
Yes
31 Mar 2022
17 Jul 2021
27 Aug 2021
17 Jul 2021
20 Aug 2021
6 Aug 2021
Amount
Lumpsum price worked out by the contractor for "Building work" as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for "Internal water supply work" as listed in Schedule 'A' Part-II .
Lumpsum price worked out by the contractor for "Internal electric Supply work" as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for "Plumbing work" as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for "Sewage Disposal works" as listed in Schedule 'A' Part-V
Lumpsum price worked out by the contractor for "Earthwork and Site Clearance works" as listed in Schedule 'A' Part-VI .
Lumpsum price worked out by the contractor for "Cement Sign Board works" as listed in Schedule 'A' Part-VII .
Lumpsum price worked out by the contractor for "Road, Path & Culvert" as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for "Area Drainage Works" as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for "Lightening Protection works" as listed in Schedule 'A' Part-X .
Lumpsum price worked out by the contractor for "External Water supply work" as listed in Schedule 'A' Part-XI .
Lumpsum price worked out by the contractor for "External Electrification work" as listed in Schedule 'A' Part-XII .
Miscellaneous items of work Sch 'A' Part-XIII
Internal electrifcation
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED Lamp 8/9 Watt complete all as specified and directed
Ceiling fan complete with accessories 230 Volt, single phase AC supply, 50 HZ, 1200mm sweep BEE 5 Star rated including connecting up with flexible PVC insulated copper cable 3 core 23/0.0076 from ceiling rose to fan connector complete all as specified and directed. Cat Part No ES-50 of Havells or its equivalent CG/Bajaj.
20W surface/wall mounted batten LED luminaire in extruded aluminium housing with PVC diffuser, integrated electronic diver, high efficiency, luminous efficacy >100 lumens/watt, operating voltage 140V-240V AC complete including 20W LED tube rod/batten with all accessories up with 3core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed. Make :- Wipro Trim LED (LL20-281-XXX-65AL1/Philips Smart Brite (BN021C LED 20S PSU CW GR 2S) Bajaj (BCLS BAL 20W CW)
LED street light with pressure die cast aluminum housing with polycarbonate cover, luminous efficacy>100 lumens/Watt, high efficiency, 25W system wattage (including driver), heat diffuser, IP-65 protection, IK-07 rating. The potted electronic driver with THD<10%, PF>0.95. LED fitting is complete all as per OEM specified and directed. LED driver and housing is of same make as of light fitting. All type of testing for photometry, electrical and electronic parameters is done in NABL approved laboratory complete including GI bracket for fixing building light bent to shape made out of 40mm dia GI medium grade pipe not less than 1.5 m length fixed with 02 Nos MS clamps made out of flat iron of size 50x6mm fabricated to shape and fixed with nuts bolts and washers and applying two coats of aluminium paint one coat of red oxide primer and making connection with 3 core PVC flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth lead protected by provision o fGI medium grade pipe 15mm bore including provision of 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx3mm with 6mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Notes:- (i) RCC pit cover shall be precast of RCC (1:2:4) Type B1, 80mm thick reinforcement with 8mm TOR steel @100 C/C in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth lead shall be protected upto test point using necessary arrangement with GI pipe and the rates includes in the unit rate of item. (iii) Charges for earth resistivity test deemed to be included in the quoted rate. (iv) PCC Chamber shall be constructed 500mm away from the edge of earth pit (v) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (vi) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (vii) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge.
Flame proof type point wiring with 1.5 Sqmm copper conductor cable (Multistranded), PVC insulated unsheathed FRLSH (using colour code as per IS) drawn through and including stove enamelled steel/ERW steel rigid conduit not less than 2mm thick, heavy duty (ISI marked) of adequate size fixed on wall including saddles with back plate for one light point controlled by one, one way switch including continuous 1.5 Sqmm copper condutctor PVC insulated and unsheathed cable as earth continuity wire connected to common earth dolly, making connection to flame proof switch, with and including stove enamelled black/ERW steel metallic rigid conduit, nuts, check nuts, including flame proof junction boxes, cable glands, washers etc complete all as specified and directed.
Supply, fixing, testing and commissioning of MCB SPN 240 Volt 16 Amp to 40 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs, complete all as specified and directed
Supply, fixing, testing and commissioning of MCB SP 240 Volt 5 Amp to 32 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs, complete all as specified and directed
Sheet metal enclosure for DB double door (IP-42/3) when MCBs to be used SPN 8 way, 240 V with 200 Amps rated bus bar, complete all as specified and directed.
LED tube light fitting flameproof type FLP-WP of LED 2x16/20W including integral reflector made of aluminum alloy LM6, bipin holders, tube rods connector block etc and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor including fixing arrangement on wall ceiling complete with flame proof flexible metallic hose conduit of size 300 mm length and suitable dia including making connection for flame proof tube light fittings with both ends screwed complete all as specified and directed. Make :- CG CAT Part No :- EXTN2LT8-16/20 or equivalent in Shyaam, Sudhir
Flame proof, weather proof 10 way SPN MCB DB 240 V 50 Hz in LM6 construction, consisting of 01 No incoming MCB SPN-10 Amps, MCB SP-6 Amps (08 Nos) as outgoing with clip on type terminals with suitable cable entries including connecting up incoming & outgoing cables, making connection to flameproof switches with and including Stove Enamelled Black/ERW Steel metallic rigid conduit, nuts, check nuts, conduit couplers/sockets. Union, junction boxes, cable glands/ bushes, washers, bolts, washers etc complete all as specified and directed.
Lightning protection works
Earthing complete with copper plate electrode 600x600x3.15mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to the copper strip earth lead 20x3mm, by means of bolts, nuts, check nuts and washers of galvanized iron and 20x3mm copper earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4), re-inforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40x40x3 mm and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exe 50 mtr to plate No 3 of SSR 2009 Part-I and connecting to feeder pillar, DG sets and Transformer all as specified including testing on completion complete all as specified and as directed.
Notes:- (i) RCC pit cover shall be precast of RCC (1:2:4) Type B1, 80mm thick reinforcement with 8mm TOR steel @100 C/C in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth lead shall be protected upto test point using necessary arrangement with GI pipe and the rates includes in the unit rate of item. (iii) Charges for earth resistivity test deemed to be included in the quoted rate. (iv) PCC Chamber shall be constructed 500mm away from the edge of earth pit (v) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (vi) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (vii) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge.
External Water supply Works
Cutting of existing GI pipe two cut of dia 100 mm in position for insertion of new GI sec of 100x100x50 size for branch connection complete with all fittings.
Material and labour of existing GI pipe two cut of dia 80mm in position for intersection of new GI sec of 80x80x50 mm size for branch connection complete with all fittings.
Material and labour of existing GI pipe two cut of dia 50mm in position for intersection of new GI sec of 50x50x40mm size for branch connection complete with all fittings.
Construction of brick masonary valve pit built in cement mortar 1:6 of size 90cm x90cm x90 cm (Internal dimension) over 15 cm, thick PCC 1:3:6 type C2 sub base extended all around 15 cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and plus pointing to brick wall surface externally as work proceed complete with MS Sheet cover 10 SWG with handle, angle iron from 40x40x6mm, 04 numbers, locking arrangements and painting complete all as per drawing No CEPZ/C-TD/006/13 Sheet No 1/1 complete all as specified and directed by Engr-in-Charge.
Construction of brick masonary valve pit built in cement mortar 1:6 of size 60cm x60cm x60 cm (Internal dimension) over 15 cm, thick PCC 1:3:6 type C2 sub base extended all around 15 cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and plus pointing to brick wall surface externally as work proceed complete with Sheet cover 10 SWG with handle, angle iron from 40x40x6mm, 04 numbers, locking arrangements and painting complete all as per drawing No CEPZ/C-TD/006/13 Sheet No 1/1 complete ass as specified and directed by Engr-in-Charge.
External Electric supply Works
Supply and fixing Junction box outdoor type made out 3 mm CRCA sheet of suitable size duly painted and fixed with suitable MS clamps of 3.00 mm thick, nut bolts including 2 Nos aluminum bus bar, 50 Amps, single phase duly insulated and fixed for terminating single phase 10 Sqmm aluminum UG cable etc consisting of following and complete all as directed: Incommer MCB SPN 40A 16KA – 01 No Outgoing MCB SP 06032A-3 Nos
Supply and fixing Junction box outdoor type made out 3 mm CRCA sheet of suitable size duly painted and fixed with suitable MS clamps of 3.00 mm thick, nut bolts etc and fixed for terminating single phase 10 sqmm aluminum UG cable etc consisting of one nos MCB SPN of Rating 20 Amps 240 volts AC, 16 KA complete all as specified and as directed
Sheet metal enclosures factory made distribution board (When MCBs are to be used) single pole and neutral 240 volts, 6 Amps, 10KA (for ESP floor light) complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less tan 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanized iron earth lead 32x6mm size, by means of bolts, nuts, check nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of 40mm thick cover of RCC (1:2: 4 ) reinforced with XPM (weight not less than 4 Kg/sqm) and frame of angle iron 40mmx40mmx3mm with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in any type of soil returning filling and removal of surplus soil to a distance not exceeding 50 m for plate No 3 of SSR 2009 Part-I and connecting to feeder pillar, DG sets and Transformer all as specified including testing on completion complete all as specified and as directed
Notes:- (i) RCC pit cover shall be precast of RCC (1:2:4) Type B1, 80mm thick reinforcement with 8mm TOR steel @100 C/C in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth lead shall be protected upto test point using necessary arrangement with GI pipe and the rates includes in the unit rate of item. (iii) Charges for earth resistivity test deemed to be included in the quoted rate. (iv) PCC Chamber shall be constructed 500mm away from the edge of earth pit (v) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (vi) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (vii) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to the Galvanized iron earth lead wire of size 4 mm dia, by means of bolts, nuts, check nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 15 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg per sqm) and frame of angle iron 40x40x3mm and with 6mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work inhand/dense soil, returning filling and removal of surplus soil to a distance not exc 50 mtr and for plate No 3 of SSR 2009 Part-I and connecting up including testing on completion complete all as specified and directed.
Notes:- (i) RCC pit cover shall be precast of RCC (1:2:4) Type B1, 80mm thick reinforcement with 8mm TOR steel @100 C/C in lieu of CI cover and the rate includes in the unit rate of item (ii) Earth lead shall be protected upto test point using necessary arrangement with GI pipe and the rates includes in the unit rate of item. (iii) Charges for earth resistivity test deemed to be included in the quoted rate. (iv) PCC Chamber shall be constructed 500mm away from the edge of earth pit (v) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (vi) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (vii) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge.
LED Flood light complete with glass and driver complete of capacity 120 watt LED with suitable size of clamps, nuts bolts for fixing on roof/wall of sentry post. (Note: MS clamps, nuts, bolts and washer shall be measured separately under relevant item)
bamral builder
NARESH KUMAR AND COMPANY
R R CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .