Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.3 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹23.9 L+₹2.6 L (12.1%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹25.2 L+₹3.9 L (18.2%)Rejected-Finance | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹26.2 L+₹4.9 L (23.0%)Rejected-Finance | L-4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹26.4 L+₹5.1 L (23.9%)Rejected-Finance | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹27.1 L
EMD Value
₹54,200
Closing Date
26 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO NP-02 (SINGLE OFFR ACCN) AT DOGRA UNDER GE (SOUTH) UDHAMPUR
2022_MES_509745_1
CWE/U(S)-111/2021-22
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (SOUTH) UDHAMPUR
₹54,200
Yes
8 Apr 2022
22 Feb 2022
28 Mar 2022
22 Feb 2022
26 Mar 2022
14 Mar 2022
60 days
Amount
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.50 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency/applicator which will further have to rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 02 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Powder coated Aluminium Anodised frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing, glazing pins/aluminium beading, etc. including powder coating of thickness minimum 50 micron, complete all as specified and as directed by Engineer-in-Charge.
Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete, all as specified and directed by Engr in Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed., complete all as specified and as directed by Engr-in-Charge
Powder coated aluminium grill/guard bars to aluminium window, complete all as specified and as directed by Engr-in-Charge.
100 mm aluminium handles, cast type anodised complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed by Engr-in-Charge.
S&F Aluminium (Die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 68 kg complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
S&F for brass mortice lock of 4 levers 100 mm thick fixed in aluminium door complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in plinth protection complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Vitrified tiles (double charged) of 10mm thick any colour (area of each tile n exceeding 0.36 sqm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 3000x600mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
10 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 3 mm thick a layer of wall care putty (JK Birla) including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint, complete all as specified and as directed by Engr-in-Charge.
3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound, complete all as specified & directed by Engr-in-Charge. (Make : Dr Fixit, LW+, STP Ltd No 1 (L) & SIKA or equivalent as specified in PS)
Providing and injecting Along the external wall below concrete or masonry apron using Antitermite Treatment chemical emulsion @ 2.25 litres per running metre including drilling and plugging holes etc. in apron. complete all as specified and as directed by Engr-in-Charge. Note : The treatment work shall be carried through authorised agency only, and certificate for the same for waranty shall have to be furnished before submitting payment)
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate. as in Slabs supported on walls/ Chajjas, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Aluminium drapory rods of 25 mm dia decorative type with wooden finish alongwith holding for brakets & end caps fix in repairs complete all as specified and as directed by Engr-in-Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
S&F Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes,fixed in repair complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Aluminium tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs, fixed in repair complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
Supply and fixing stainless steel wall mounted cloth hanger with 6 peg set, complete all as specified and as directed by Engr-in-Charge.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 50mm bore, complete all as specified and as directed by Engr-in-Charge.
Salt-glazed stoneware gully traps, size 150 x 150 mm, square or round mouthed, type 'P', including setting and jointing to drains with cement mortar 1:1, fixed in repairs, including demolition of old unserviceable gully traps complete all as specified and as directed by Engr-in-Charge. (ISI Marks).
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 75mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed by Engr-in-Charge.
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 100mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed by Engr-in-Charge.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4), complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
Cast iron branch pieces, single/double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed by Engr-in-Charge.
Cast iron branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 bore, fitted with oval access door as in repairs complete all as specified and as directed by Engr-in-Charge.
50mm Cast iron cowls complete all as specified and as directed by Engr-in-Charge.
Cast iron Reducer 100mm by 50mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed by Engr-in-Charge.
Cast iron Reducer 75mm by 50mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed by Engr-in-Charge.
Cutting holes exceeding 150 sq.cm but nexc 400 sq.cm in to brick walls built in CM and making good in cement concrete 1:2;4 type B1 for fixing of cooler Brackets etc complete all as specified & directed by Engr-in-Charge.
Glass shelf with chromium plated guard rails,fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing corner shelf with glass with brackets,fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
Health faucet with 8mm dia 1m long flexible tube and wall hook with all accessories, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed by Engr-in-Charge.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm fixing in repair complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair complete all as specified and as directed by Engr-in-Charge.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as direceted by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Brass Chromium plated over head shower rose, 75mm size with swivel joint fixed to pipe or union of 15mm bore, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Dismantling water tank of capacity exceeding 250 litres but not exceeding 500 litres each and removing from site/to store, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), complete all as specified and as directed by Engr-in-Charge.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, complete all as specified and as directed by Engr-in-Charge.
Soap dish fancy type chromium plated fixed with brass screws and wooden/plastic cleats complete all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed by Engr-in-Charge.
S&F anodized aluminum fixed partition using approved medium weight aluminium section as follows: Horizontal members size 63.50 x 38.10mm at 0.75 Kg/m c/c spacing shall be n. exc 90cm. Vertical member size 63.50 x 38.10mm at 0.75 kg/m. c/c spacing n.exc 90cm. 3' height portion- Pre laminated board 12mm thick including necessary clips, rubber beading aluminium beading and fixing to the adjoining/existing wall etc. Top portion 12mm thick toughened glass with all necessary fittings/fixtures etc. complete all a specified and directed by Engineer-in-charge.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
Glossy finished colour Chequered cement concrete tiles of imported pigment (300mmX300mmX 30mm) thick, set, jointed and pointed in neat cement slurry and pointed with cement mixed with pigment, laid including and over 20mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up drain pipes, 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, including concrete bedding and haunching complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes complete all as specified and as directed by Engr-in-Charge. Note:-(i) Thickness of bed below barrel of pipe-10 Cms. (ii) width of bed- outer dia of pipe plus 30 cms.
Reinforced concrete pipes 200mm bore ,class NP2,laid and jointed complete with collars etc. complete all as specified and as directed by Engr-in-Charge.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engr-in-Charge.
Pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab, chullah hoods and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in surface channels and drains, complete all as specified and as directed by Engr-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed by Engr-in-Charge.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted , built in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Providing, pre-cast cement concrete 1:3:6 type C-I (20mm graded) as in bond stones and in similar works bedded and jointed in cement morter 1:6, complete all as specified and as directed by Engr-in-Charge.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses of granite or trap stone etc. and hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40 mm complete all as specified and as directed by Engr-in-Charge.
PVC (SWR) pipe, 110mm dia (ISI marked) in any length embedded in cement mortar for weep holes at locations complete all as specified and as directed by Engr-in-Charge.
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses stone masonry in Cement Mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified & directed by Engr-in-Charge. Note: Modular metal flush boxes & cover plates deemed to be included inquoted rate.
Description all as per item No 106 above but one 3/5 pin 6 Amp socket outlet on independent board .
Description all as per item No 106 above but one 3/5 pin 6 Amp socket outlet on the same board with other switch.
All as per description of Serial item No 106.00 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 106 above but one 3/5 pin 20 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,6 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,16 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Modular Socket outlet, 2 module, 3 pin, 6 Amp flush type , complete all as specified and as directed by Engr-in-Charge.
Modular Socket combined, 2 module, 2 in 1, 6/16 Amp flush type , complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Bell push Modular type, 1 module, 6 Amps 230 volts complete all as specified and as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
LED wall mounted mirror lighting fixture 10 Watt LED, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
S&F for 1x40 Watt Candle E14 wall mounted fancy type light, SS finish fixture with opal PC differ suitable for 40 Watt incandescent candle lamp, complete all as per the directions of Engr-in-Charge.
S&F of LED 3 watt Bed light fitting (warm white) with white metallic body, complete all as specified and as directed by Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with MCCB as incommer and MCBs as outgoings with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,incl taking down existing DBs, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repairs MCCB 4 pole, 415 volts 100 Amps with breaking capacity 25 KA " C" Curve complete all as specified and as directed by Engineer-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, fixed in repair complete all as specified and as directed by Engineer-in-Charge.
MCB SP, 10 to 40 Amps,240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps,240 Volts, rupturing capacity 10 KA "C" Curve including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC concealed rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Taking down ceiling fan/ exhaust fan and cable etc. and refixing/hanging the same after repair/replacement of damaged/worn out parts like canopy 02 Nos, down rod, clamps with nuts, bolts and washers, rubber bush, greasing, oiling and provn of cable from ceiling rose to fan, etc. including painting with two coats of synthetic enamel white paint and writting Ser No/Mes No with black paint complete, all as specified and as directed by Engr-in-Charge. Note:- (i) The spares like condensor, ball bearing , cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/ damage deemed to be replaced and make the ceiling fans functional. No extra pavements will be done on this account.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 132 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 16 sqmm 4 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles fixed in repair complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Preparation of new surfaces plastered and applying three coats of white wash on ceiling, complete all as specified and as directed by Engr-in-Charge.
Preparation of old surfaces plastered or unplastered and applying two coats of white wash on ceiling or facia, complete all as specified and as directed by Engr-in-Charge.
s l sharma and sons
AKBAR FURNITURE HOUSE AND TIMBER MERCHANT
M/S JANDIAL ENTERPRISES
paras ram pachiala
KALSOTRA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .