Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance B 230 4TH CROSS 1ST STAGE PEENYA 4TH CROSS 1ST STAGE PEENYA INDUSTRIAL ESTATE BANGALORE KARNATAKA 560058 UDYAM KR 03 0056730 29AAGCR5844Q1ZG R M MII STATUS AS VERIFIED | BENGALURU URBAN | KARNATAKA | 560058 | Admitted-Finance |
| 3 | Admitted-Finance NO 2 13 1ST PHASE PEENYA INDUSTRIAL AREA PEENYA BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | Admitted-Finance |
Tender Value
₹22.4 L
EMD Value
₹44,804
Closing Date
10 Oct 2022, 2:00 pmClosed
PROJECT DIRECTOR
Office of the Project Director, FRFCF KALPAKKAM.
Design, fabrication and supply of glove box and installation of Microwave furnaces in the glow box with leak testing at FRFCF site, NRB, Kalpakkam.
2022_BARC_713978_1
BARC/NRB/FRFCF/FFP/ETR064/2022
Open Tender
Metal Fabrication
Item Rate
365 days
FRFCF, KALPAKKAM
Please refer the Tender Document
8 documents required · 8 mandatory
₹0
₹44,804
15 Nov 2022
23 Sept 2022
14 Oct 2022
23 Sept 2022
10 Oct 2022
23 Sept 2022
23 Sept 2022 - 7 Oct 2022
Amount
Fabrication, supply & installation of SS 304 Glove box Skeleton body as per Annexure-A, (Ref. Annexure F, Fig. 1 & 2)
Fabrication, supply & installation of MS Carriage and Top MS plate suitable for glove box as per Annexure-A, as indicated in Annexure F, Fig. 9
Fabrication, supply & installation of GB side panel (RHS) as per Annexure-A, (Ref. Annexure F, Fig. 1) with 8" ports and 12 " Bag in/out port
Fabrication, supply & installation of GB side panel (LHS) as per Annexure-A, (Ref. Annexure F, Fig. 1) with 8" ports and 12 " Bag in/out port
Fabrication, supply & installation of GB Front panel as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.5/00 to NRB/FRFCF/FFP/PKS/1.0/1.5/04) with 8" ports and Rhombus view window
Fabrication, supply & installation of GB Back panel as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.5/00 to NRB/FRFCF/ FFP/PKS/1.0/1.5/04) with 8" ports and Rhombus view window
Fabrication, supply & installation of GB top panel as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.6/00) witrh lighting windows
Fabrication, supply & installation of inlet HEPA filter box as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.7/00) (Hepa filter not in supplier scope)
Fabrication, supply & installation of Elliptical port as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.8/00)
Fabrication, supply & installation of Outlet HEPA filter box as per Annexure-A,(Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.9/00) (Hepa filter not in supplier scope)
Fabrication, supply & installation of 8 inch glove port as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.10/00)
Fabrication, supply & installation of circular view window as per Annexure-A, (Ref. Annexure G, NRB/FRFCF/FFP/PKS/1.0/1.10/00)
Fabrication, supply & installation of Nozzle assembly as per Annexure-A,
Fabrication, supply & installation of furnace GB panel clamping strip with 15mm sq. bar (Front&Back) as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.13/00)
Fabrication and supply of Furnace GB panel clamping strip with 15mm sq. bar, side connecting panel assembly (RHS & LHS) as per Annexure-A, (Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.14/00)
Fabrication and supply of furnace GB panel clamping strip with 15mm sq. bar Top panel Assembly as per Annexure-A,(Ref. Annexure G, Fig. NRB/FRFCF/FFP/PKS/1.0/1.15/00)
Fabrication, supply & installation of 1" sch 40 pipe with 1 inch flanged fitted ball valve and installing Rotameter issued as FIM, as per Annexure-A, (Ref. Annexure F, Fig. 6)
Fabrication, supply & installation of 1.5" sch 40 pipe with 1.5 inch flanged fitted ball valve as per Annexure-A, (Ref. Annexure F, Fig. 7)
Fabrication, supply & installation of half inch pipe 250mm as per Annexure-A,
Fabrication, supply & installation of transfer Bagin/Bagout bungs (12 inch) as per Annexure-A, (Ref. Annexure F, Fig. 8)
Fabrication, supply & installation of transfer Bagin/Bagout port (12 inch) bung as per Annexure-A, (Ref. Annexure F, Fig. 9)
Fabrication, supply & installation of Lighting fixtures as per Annexure-A, Ref. Fig. (Ligting fixtures with tube light top of the GB)
Fabrication, installation of SS Wave guide and providing microwave barrier flange assembly, fixing, aligning, welding of fixture inside glove box, furnace (Ref. Annexure F, Fig. 3 & 4)
Fabrication, installation of SS pipe and syphon assembly , fitting, supports, welding, connected to existing furnace assembly coolant line, connecting to flow switch bank etc as per Annexure-A
Fabrication, installation of SS pipe assembly and providing feed throgh nipple fittings, connected to gas roatameter(issued as free issue material),valve assembly etc as per Annexure-A
Fabrication, installation of Feed through SS gland and provided with cable , cable sealent, leak tight testing, as per Annexure-A
Fabrication, installation of Feed through SS gland and provided with Heating element gland and providing connection to heating elements as per Annexure-A (Heating element not in supplier scope)
Fabrication, installation of Feed through SS gland and provided with thermocouple gland and providing connection to thermocouple as per Annexure-A (Thermocouple not in supplier scope)
Fabrication, installation of Feed through SS gland and provided with Proximity sensor wiregland and providing connection to sensor as per Annexure-A (Proximity sensor not in supplier scope)
Fabrication, installation of Feed through SS gland and provided with fire detector wire gland and providing connection to fire detector as described and as refered in fig. 8 (Fire detector not in supplier scope)
Fabrication, installation of Feed through SS gland and provided with flood detector wire gland and providing connection to flood detector as per Annexure-A (Flood detector not in supplier scope)
Fabrication, installation of Feed through SS gland and provided with pressure indicator wire gland and providing connection to pressure indicator wire as per Annexure-A (Pressure indicator not in supplier scope)
Fabrication, installation of Feed through SS gland and provided with camera wire gland and providing connection to camera as described and as per Annexure-A (Cameras not in supplier scope)
Fabrication, installation of Feed through SS gland and provided with servo motor wire gland and providing connection to servo motor as per Annexure-A (Servo motor not in supplier scope)
leak testing of glove box as per Annexure-A
Installation of Microwave furnace inside the glove box as per Annexure-A
Leak testing of glove box with microwave furnace as per Annexure-A, (Ref. Annexure F, Fig. 2)
Vacuum techniques PVt Ltd
PANANK ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .