Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹13.5 L+₹2.0 L (16.9%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹15.3 L+₹3.7 L (32.3%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L3 | Rejected-Finance Rejected | |
| 4 | Rejected-Technical GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Oct 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
REPAIR MAINT OF WATER STORAGE HEATERS GEYSERS SOLAR WATER HEATERS AND VARIOUS COOLING APPLIANCES WITH CONNECTED AND MISC ITEMS IN THE AREA OF HQ WAC AND CAMERO OF AGE EMII UNDER GE AF SPARK
2023_MES_612794_2
GE/SP/ TOKEN-50/2023-24
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹50,000
Yes
29 Feb 2024
26 Sept 2023
20 Oct 2023
26 Sept 2023
17 Oct 2023
2 Oct 2023
Amount
Supply & fixing in replacement the following unserviceable spare parts for Water Storage Heater (Geyser) of capacity 25/50 Ltrs of any make & model installing inside of Subroto park and rectifying all the defects as mounted and fitted on wall with nut & bolts and re-fixing to its original postion after repair and making geyser satisfactory functional complete all as specified and directed by Engineer-in-charge (a) Geyser assembly including rubber seal,screw as per existing model
(b) Heating element 2000 watt 240 volts AC including seal, washers
(c) Heating element 1500 watt 240 volts AC including seal, washers
(d) Steel tank 50 ltrs as per existing model
(e) Steel tank 25 ltrs as per existing model
(f) Copper tank 50 ltrs as per existing model
(g) Copper tank 25 ltrs as per existing model
(h) MS Sheet bottom cover in two pieces duly painted with 2 coats of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete.
((i) MS sheet top cover in two pieces duly painted with 2 coat of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete.
(j) MS Sheet outer cover duly painted with 2 coat of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete.
(k) Thermostate (temperature control device) for 25/50 ltrs capacity geysers.
(l) Indicating lamp with cable(Red/Green) for 25/50 ltrs capacity geysers as per existing model complete.
(m) 3 core flexible copper cable of size 2.5 sq mm 1100 V grade.
(n) 3 core flexible copper cable of size 4 sq mm.
(o) Metal clad plug top 20/25 amps 230 Volt, Single Phase.
(p) Metal clad socket 20/25 amps 230 Volt, Single Phase.
(q) Single pole and neutral enclosure with a two pin and earth plug and socket 240 V complete with one single pole MCB 20 amps.
(r) MCB SP 6-32 amps 230 Volt c series 50 Hz Single Phase.
(s) Socket outlet 3 pin 16 amps piano type 230 V flush type.
(t) Switch piano type 16 amps 230 V single pole.
(u) PVC plug top 3 pin 16 amps suitable for 230 volts AC supply.
(v) PVC gang box suitable for one switch /socket 16 Amps complete with screw and necessary arrangement complete all as specified and directed by Engr-in-charge.
(w) 450 mm long flexible hot water connection pipe with two Nos union suitable for 15mm bore iron pipe complete all as specified and directed by Engr-in-charge .
(x) 600 mm long flexible hot water connection pipe with two Nos union suitable for 15mm bore iron pipe complete all as specified and directed by Engr-in-charge.
(y) Pressure release valve brass chromium plated screw with 15mm bore iron pipe and suitable for 50/25 ltrs geyser complete all as specified and as directed by Engineer-in-charge
(z) Safety valve brass of cast alloy of screw with 15mm bore iron pipe & suitable for 50/25 ltrs geyser complete all as directed.
(aa) New glass wool as per existing density for geyser of any capacity make & model complete all as specified and directed by Engineer-in-charge.
(ab) 15mm bore non-return valve of brass chromium plated connected to iron pipe or other fittings complete all as specified and as directed by Engineer-in-charge Notes for Srl Item No 1 to 28 (a) Contractor will provide well experienced and well conversed men power against these items including Sunday & Holidays from 0900 to 1700 hrs . (b) Electrician should be 10th passed having 4 year experience in the trade or ITI holder in the relevant trade having proper knowledge for repairing work of geyser items.(c) All T&P required for repair work shall be provided by contractor at own arrangement to trade men & helpers (d) All complaints should be attended with in 24 hours. Panelty charges for non attending complaints within 24 hours shall be Rs. 500/- per day. The cost of man power shall be deemed to be included in the unit rate of respective items. (b) Contractor shall submit the attendance register and documents of said man power duly verified by Engr-in-charge at the time of payment.
M&L for Removing existing paint from the steel surface of geyser of 50/25 ltrs capacity and applying two coats of synthteic enamel spray paint complete all as specified and as directed by Engineer-in-charge.
M & L in replacement for 15mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M & L in replacement for 20mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M & L in replacement for 25mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M & L in replacement for 32mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M&L in replacement Sub main wiring complete with non metallic rigid PVC insulated fire retardent grade unsheathed 1100 volts grade multistranded copper conductor cable 2 run of 4 sqmm single core conforming to IS-694 with copper conductor drawn through and including suitable dia PVC conduit, conduit fittings and accessories concealed in walls, roofs and floors alongwith 1 run of 4 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor. Note :- 3 runs 4 sqmm cable incld PVC conduit shall be measured as one unith length.
S&F in replacement to hose pipe for solar panel to hot water tank as per dia and thickness suitable for solar heating system of cap 200/300/400/500 LPD by clamping/tightening properly for leak proof joint complete all as specified and directed
M&L for repairing of the leakage of solar hot water tank of capacity 200/300/400/500 LPD by taking down removing insulation carefully complete and taking to workshop for necessary repair by soldering /welding including replacementhing density (48kg/m3) and K value 0.03W/mk to witn stand temp. upto 250 degree celcius and insulation materials injected of thickness 100mm and refixing of its original position for satisfactory functioning of the unit complete all as specified and directed.
S&F in Repalacment of self priming monoblock pump set of cap. 0.5 HP single phase 220 Volts. +/_ 6% speed 2780 RPM complete.
S&F in Repalacment of broken/rusted steel hot water SS(20 SWG)tank (inner and outer tanks)of capacity suitable for 200 LPD solar water heater including high density (48 kg/M3 ) and K value 0.03 W/mK to with stand temp. upto 250 degree celcius and insulation material injected PUF insulation of thickness 100 mm complete all as specified and as directed by Engr-in-Charge.
All as per item No. 39 here in above but suitable for capacity 300 LPD
All as per item No.39 here in above but suitable for capacity 400 LPD
All as per item No. 39 here in above but suitable for capacity 500 LPD
S&F in replacement triple layers rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) with capacity 1000 litres for make up water of solar water heater complete all as specified and directed .
S & laying in replacement triple layer Hot water pipe duly (GI) insulated with glass wool and aluminium clading 15mm bore with connected accessories complete all as specified and directed
S & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 20mm bore with connected accessories complete all as specified and directed
S & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 25mm bore with connected accessories complete all as specified and directed
S & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 32mm bore with connected accessories complete all as specified and directed
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 32mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 20mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 15mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal angle valve with screwed both ends for iron pipe and fixed for 15mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement NRV 32mm dia made out of brass complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MS dead flange for plate collector of solar water heater panels as per existing size with gasket along with connected accessories complete all as directed
S&F in replacement gasket for flate plate collector of solar water heater as per existing size along with connected accessories complete all as directed.
S&F in replacement float valve for 15mm dia along with connected accessories complete all as directed
M&L for rewinding of blower motor single phase 230 V of air curtain of any make,door opening size and air velocity with super enamelled copper winding wire including replacement of bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed.
S&F in replacement of blower unit/aluminium alloy fans as per existing for air curtain any make,door opening size and air velocity complete all as specified and directed .
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 32mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 25mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of toughened glass 6mm thick suitable for existing solar flat plate collector of any size complete all as specified and as directed by Engineer-in-charge
M&L for point wiring complete with 2.5 sqmm single core PVC insulated unsheathed cable 100 volts grade FRLS IS-694 multi stranded copper drawn through and including non metallic rigid PVC conduit fittings not less than 20mm dia and conduit accessories concealed in walls roofs and floors etc including terminal boxes fabricated with 1.6mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3mm thick fixed with cadmium plated iron screw for housing the switch socket outlet 3 pin 15 amps and including provn of 2.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continity conductor and connection to common earth dolly complete incld taking down old u/s.
Dismantling,shifting of water storage heater of any make & model from one location to another location and refixing the unit with gutties/fasteners, cutting wall/concrete incl arrangement of required T&P, fixing of extra pvc flexible multistranded copper conductor of suitable size, connection of hot water pipe and GI piping and making good distributed surface all as specified and directed by Engineer-in-Charge
M&L for comprehensive maintenance of existing solar flat plate of cap 200/300/400/500 LPD collector of indirect heating system comprising of inspection descaling brushing and cleaning of collector panel riser tubes header tubes heat absorber tubes connecting pipes and examining of water tightness of the same after acid wash cleaning and descaling and repairing of leakage if any using welding / brazing, drain out the water from panel and tank repeating two to three times to get dirty water out etc complete all as specified and as directed by Engineer-in-charge. NOTE : - Servicing of solar water heater shall be carried once in every two months. All the comprehensive maintenance work will be carried out through original authorized manufacturer of collector panel of solar water heating system only
S&F in replacement to unsv heating element of cap 3 KW suitable for solar water heater system of cap 200/300/400/500 LPD as per existing.
S&F in replacement to unsv thermostate suitable for solar water heater system of cap 200/300/400/500 LPD as per existing.
M&L for Painting of steel surfaces of solar water heater system incl tank, frames etc with two coats of super enameled synthetic spray paint over a coat of primer after preperation of old surface and making good complete all as specified and directed.
WATER COOLER Taking down the water cooler of any capacity / make / size from site, opening side covers of water cooler and overhauling / servicing of water cooler by carrying out the following works at different location complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling descaling brushing cleaning of storage tanks (b) Examine water tightness of stotage tank after cleaning (c) Carry out operations of stop cock, push cock, float valve etc (d) Replace washer & glands of all taps to ensure water tightness (e) Inspect over flow and remove blockage obstruction if any (f) Check and correct earth continuity of electrical items (g) Check thermostate and test its functioning (h) Inspect drain pipe and remove blockage if any (j) Check & correct all electrical wiring and its functioning (k) Testing of water coolers after repairs for satisfactory functioning complete
Taking out old unserviceable compressor of water cooler of capacity 40 / 80 to 60 / 120 litres any make / size and providing new company sealed compressor and connectig up suction and discharge copper pipe including extra copper tubing with brazing work, gas welding, pressure testing of leakage,leakage rectification, vacumising and charging of refrigerant gas R-22/ Non-CFC as applicable upto required level testing comissioning complete all as specified and as directed by Engineer-in-charge
Taking out old unserviceable compressor of water cooler of capacity 150 / 150 litres any make / size and providing new company sealed compressor and connectig up suction and discharge copper pipe including extra copper tubing with brazing work, gas welding, pressure testing of leakage,leakage rectification, vacumising and charging of refrigerant gas R-22/ Non-CFC as applicable upto required level testing comissioning complete all as specified and as directed by Engineer-in-charge
M&L in replacement of Starting capacitor 36/40/60mfd for water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of Starting capacitor 80/100 mfd for water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of Starting capacitor 120/150 mfd for water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of running capacitor 10/15/20 mfd for water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of running capacitor 30/36 mfd for water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of condensor 2.5/4/6 mfd for fan motor of water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of thermostate switch for water cooler of any make and capacity complete all as specified and as directed by Engineer-in-charge
M&L in replacement of overload protector suitable for compressor for water cooler of any make and capacity complete all as specified and as directed by Engineer-in-charge
M&L in replacement of starting relay kit suitable for any make and capacity of water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of Condensor motor of 1/16 or 1/32 or 1/40 HP of water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of Condensor fan blade for 1/16 or 1/32 or 1/40 HP motor suitable for water cooler of any make and capacity complete all as specified and as directed by Engineer-in-charge
M&L in replacement of bib cock 15mm bore fancy type chromium plated push type screwed down scewed for iron pipe or for brass ferrule fixed in repair suitable for existing water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of electric wiring kit suitable for existing water cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of copper condesnor coil for water cooler of cap 40/80 ltrs as per existing model and thickness including GI frame, brazing work, leak check and dehydration complete all as specified and as directed by Engineer-in-charge
S&F in replacement of copper condesnor coil for water cooler of cap 60/120 ltrs as per existing model and thickness including GI frame, brazing work, leak check and dehydration complete all as specified and as directed by Engineer-in-charge
S&F in replacement of copper condesnor coil for water cooler of cap 150/150 ltrs as per existing model and thickness including GI frame, brazing work, leak check and dehydration complete all as specified and as directed by Engineer-in-charge
S&F in replacement of stainless steel water storage tank for water cooler of cap 40/80 ltrs as per existing model including puf insulation material complete all as specified and as directed by Engineer-in-charge
S&F in replacement of stainless steel water storage tank for water cooler of cap 60/120 ltrs as per existing model including puf insulation material complete all as specified and as directed by Engineer-in-charge
S&F in replacement of stainless steel water storage tank for water cooler of cap 150/150 ltrs as per existing model including puf insulation material complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC float valve assembly suitable for water cooler of any size / capacity non metallic PTMT symet body complete all as specified and as directed by Engineer-in-charge
S&F in replacement of unserviceable PVC insulated and PVC round sheathed with stranded coper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 1.5 sqmm 3 core complete all as specified and directed.
S&F in replacement of PVC waste pipe 20/32mm dia with complete fittings suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for spray painting of outer surface of water cooler of any make and capacity with two coats of synthetic enamel paint of approved colour after preparation of old painted surface of water cooler by rubbing,brushing and cleaning at site and re-marking of MES No using black paint complete all as specified and as directed by Engineer-in-charge
M&L in replacement of receptacle water cooler tray made out of 18 gauge GI sheet size as specified and directed by Engineer-in-charge with PVC drain pipe (not less than 2.0 mtr) and fixing in water cooler complete all as specified and as directed by Engineer-in-charge
Taking down repair to water cooler storage tanks removal of leakage including soldering,welding,sealing condesnor motor base and arms (Stand) removed old and new 18 gauge GI sheet and arms fitting with soldering / welding with component in workshop as per requirement complete all as specified and as directed by Engineer-in-charge
Disconnecting and taking out water cooler of any type any capacity and refixing the same after removal of leakage in condensor of cooling coil including flushing dehydration and charging refrigerant gas R-22/Non-CFC as applicable in the system including pressure testing, vaccumising and extra copper tubing complete and testing the water cooler for proper functioning in workshop complete all as specified and as directed by Engineer-in-charge
M&L in replacement rubber gasket suitable for water cooler top cover and repair to top tank cover replacement of hinges fitting of glass wool finishing of sheet work and ligh closing complete all as specified and as directed by Engineer-in-charge
Shifting & Installation of water cooler of any make and capacity including all accessories from one location to other location of building / one building to another building and or from site to store or sub-division vice versa reconnecting electrical / water connections complete all as specified and as directed by Engineer-in-charge
REFRIGERATOR / DEEP FREEZER Taking down the Referigerator / Deep freezer of any capacity / make / size from site and overhauling / servicing of refrigerator / Deep Freezer by carrying out the following works at different location complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling descaling brushing cleaning refrigerator / deep freezer (b) Check and correct earth continuity of electrical items (c) Check thermostate and test its functionng (d) Check & correct all electrical wiring and its functioning complete
M&L re-marking of MES No Refrigerator / Deep freezer of any capacity and make using black paint complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Thermostate switch of existing capacity and make for Refrigerator / Deep Freezer including taking down old unserviceable thermostate complete all as specified and as directed by Engineer-in-charge
S&F in replacement of overload protection relay of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable overload protection relay complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Defrost timer 50 HZ single phase 220-240 Volt of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable defrost timer complete all as specified and as directed by Engineer-in-charge
S&F in replacement of lamp with holder of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable lamp with holder complete all as specified and as directed by Engineer-in-charge
S&F in replacement of copper capilary tube of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable copper capilary tube complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Freezer cabinet of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable Freezer cabinet complete all as specified and as directed by Engineer-in-charge
S&F in replacement of waste water tray of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable waste water tray complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Bottle self of existing capacity and make Refrigerator including taking down old unserviceable Bottle self complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Ice tray of existing capacity and make Refrigerator including taking down old unserviceable Ice tray complete all as specified and as directed by Engineer-in-charge
S&F in replacement of copper tube of size 1/4" of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable copper tube complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Anti moist solution of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable Anti moist solution complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Dry filter of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable Dry filter complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Compressor coil complete including gas welding and soldering of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable Compressor coil complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Megnetic door gasket of existing capacity and make Refrigerator / Deep Freezer including taking down old unserviceable gasket complete all as specified and as directed by Engineer-in-charge
Taking out unserviceable compressor (sealed unit) from from refrigerator / Deep freezer of capacity 165/175 ltrs, opening of compressor unit and replacement with new compressor as per existing make and model complete with relay and gas charging complete all as specified and as directed by Engineer-in-charge
Taking out unserviceable compressor (sealed unit) from from refrigerator / Deep freezer of capacity 285/300/310/340 ltrs, opening of compressor unit and replacement with new compressor as per existing make and model complete with relay and gas charging complete all as specified and as directed by Engineer-in-charge
Disconnecting and taking out Refrigerator / Deep freezer of any type any capacity and refixing the same after removal of leakage in condensor of cooling coil including flushing dehydration and charging refrigerant gas R-22/Non-CFC as applicable in the system including pressure testing, vaccumising and extra copper tubing complete and testing the Refrigerator / Deep freezer for proper functioning in workshop complete all as specified and as directed by Engineer-in-charge
DESERT COOLER Taking down the desert cooler of any size comprissing of following task at different location complete all as specified and directed by Engineer-in-charge (a) Disconnecting of electric supply and taking down desert cooler from existing location and refixing after overhauling servicing with greasing oiling complete (b) Descaling brushing cleaning of bottom tank (c) Examine water leaking of storafe tank after cleaning and servicing (d) Check & Examine all items i.e Fan motor, pump, regulator, fan blades rectify defecets of minor nature (e) Testing of desert cooler after repair / servicing and fixing position complete.
Painting to desert coolers at site or site of work with two coats of synthetic enamelled greay paint on extarnal surfaces, two coats of black anti corrosive paint on internal surfaces by spray painting machine including shutter, top, bottom and re-marking of MES No using black paint complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Electric motor for fan 18" / 20" sweep, single phase 3 speed 100% water resistance, 100% dust proof withstand, voltage fluctuation 170 V - 270 V, rust proof totally enclosed with double ball bearing 900-1400 RPM, electric connection with copper cable of appropriate gauage including dismantling of unserviceable electric motor complete all as specified and as directed by Engineer-in-charge
Taking down including rewinding of electrical fan motor kit single phase 230 Volt 900-1400 RPM for 300 CuM/Hr to 5000 Cum/Hr capacity as required at site with super enamelled copper winding wire complete all as specified and as directed by Engineer-in-charge
S&F in replacement of 15mm dia PVC pipe for desert cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC distributor with one linlet and three outlet heavy duty complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC elbow 15mm size heavy duty complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC / MS blade heavy duty of existing size complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Mild steel bracket for cooler fan of existing size complete all as specified and as directed by Engineer-in-charge
S&F in replacement of condesnor of 3.15 to 4.0 mfd complete all as specified and as directed by Engineer-in-charge
S&F in replacement of three speed electronic regulator for desert cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC insulated and PVC sheathed flexible wire of 23/.0076" copper conductor 3 core complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Plug top 3 pin 5 amps for desert cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Plug top 3 pin 15 amps for desert cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of submersible pump 230 volts single phase suitable for desert cooler of cap 3000 CuM / Hr to 5000 CuM / Hr complete all as specified and as directed by Engineer-in-charge
S&F in replacement of wood wool pad (set of 03 Nos) heavy duty weight not less than 750 gm suitable for desert cooler of cap 3000 CuM / Hr to 5000 CuM / Hr complete all as specified and as directed by Engineer-in-charge
S&F in replacement of front grill steel frame (Metallic) of best quality suitable size and capacity for desert cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of front grill Plastic frame of best quality suitable size and capacity for desert cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of wire mesh (set of three) powder coated for fixing wood wool pads complete all as specified and as directed by Engineer-in-charge
S&F in replacement of side shutter steel frame (set of three) suitable size and capacity for desert cooler complete all as specified and as directed by Engineer-in-charge
Shifting & Installation of Desert cooler of any capacity including all accessories from one location to other location of building / one building to another building and or from site to store or sub-division vice versa refixing, reconnecting electrical / water connections complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of GI tubing medium grade 15mm dia with all fittings complete laid on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe 15mm dia complete all as specified and as directed by Engineer-in-charge.
S&F in replacement PVC connection PIPE for 15mm dia 45 CM LONG complete with two Nos brass unions heavy duty complete all as specified and as directed by Engineer-in-charge.
M&L PVC sun board sheet 3mm thick including complete fitting / railing in the window as required for desert cooler complete all as specified and as directed.
Taking out rusted & leaking desert coolers from site / store dismantling removing old body accessories supply & fixing body for desert cooler in replacement of 3000 Cum/Hr to 5000 Cum / Hr capacity made out of GI sheet 18 SWG including refixing of impeller fan blade motor stands nuts and bolts and refixing pump fan motor assembly complete all as specifiewd and as directed by Engineer-in-charge
Charges for attending minor complaints for water cooler, refrigerator , deep freezer and desert cooler to rectify the minor diffects I,e checking of electrical connections, mode of ACs , temprorry defaults all as specified and directed by Engineeer -in- Charge.
Supply and installation in replacemment of voltage stabilizer capacity 5 KVA, AC supply 180 Volt to 240 Volt, 50 Hz fixing on wall all as specified and directed by Engr-in-Charge.
Supply and installation in replacemment of voltage stabilizer capacity 3KVA, AC supply 180 Volt to 240 Volt, 50 Hz fixing on wall all as specified and directed by Engr-in-Charge. Notes:- Contractor will provide well experienced and well conversed man power for day to day complaints. (a) The Ref Mech should have minimum 4 years experience in the relevant trade. (b) All T&P required for repair work shall be provided by contractor at own arrangement to tade man and helpers. (c) All complaints should be attended with in 24 Hours. (d) Penalty charges for non attendind complaints within 24 hours shall be decided by Engg-in-charge. (e) The cost of man power shall be deemed to be included in the unit rate.
J.P. Enterprises
HONEY COLLECTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .