Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC DADAWA KURIYAR KHAS BASTI BASTI UTTAR PRADESH 272178 | BASTI | UTTAR PRADESH | 272178 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹42.8 L+₹1.5 L (3.69%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹43.2 L+₹1.9 L (4.60%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹44.5 L+₹3.2 L (7.69%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹44.7 L+₹3.4 L (8.21%)Rejected-Finance 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹42.8 L
EMD Value
₹85,686
Closing Date
16 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
SPL REPAIR TO DIVING TANK AND ITS ADJACENT BLDG, PROVN OF STORAGE SHELTER AT NEWLY CONSTRUCTED OFFRS MESS OF 5 PARA (SF) AND INCLUDING CERTAIN MINOR WORKS UNDER GE (EAST) AGRA
2023_MES_610825_1
9562/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹85,686
Yes
19 Sept 2023
26 Jul 2023
23 Aug 2023
26 Jul 2023
16 Aug 2023
9 Aug 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L for Reinforced cement concrete type B0 1:2:4 (12.5mm graded aggregate)in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Reinforced cement concrete type B0 1:2:4 (12.5mm graded aggregate) in Chajjas complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 6.00 above but 6mm to 8mm dia.
All as per item No 6.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls/ ceilingsand soffits etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including 15mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 20 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound @ 2% by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid separately under respective item of Sch ‘A’.
M&L for 15 mm thick rendering in CM 1:6 on other than fair faces of brick or concrete surface with finished fair and even complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey pigment cement and pigments including 15mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. s etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match colour of tiles laid over and including 10mm thick screed bed or bedding layer of cement mortar (1:3) complete all as specified and directed.
M&L for 350x 250x 7 mm/ 450X 350X 7mm thick laid in neat cement slurry and pointed in white or colour cement to match colour of tiles laid over and including 10mm thick screed bed or bedding layer of cement mortar (1:3) in approved pattern on 3-6mm(5mm average) thick bed of adhesive mortar of polymer modified cementitous adhesive (Bal Endura gold star/letecrete/rock admix )in conjunction with polymer modified liquid Bal Endura admix Adlor equivalent product of letercrete/Rock force mixed in required porporition as specified by manufactured including filling/scaling of joints 2-3mm thick between the tiles with epoxy grout of Bal Endura Epoxy grout/Letecrete/Rock force with matching colour pigment to make it water tight and finished neat complete all as specified and directed.
M&L PCC 1:3:6 C-2 (using 40mm graded crushed stone aggregate) as in plinth protection, path (75 mm thick) finished even and fair complete all as specified and directed.
M&L PCC 1:2:4 type B-2, 50mm thick cement concrete in path / floor complete all as specified and directed.
S & F in repairs 15 mm bore chromium plated fancy bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 10 ltrs capacity PVC flushing cistern low level (white) with inlet ball valve and handle including brackets, rubber bush, washers etc complete all as specified and directed.
S&F in repair 15 mm bore CP Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
S&F in Repair Vitreous china wash basin white flat back size 550 x 400mm incl waste pipe chain plug brackets and 32mm dia bore CP coupling complete all as specified and directed.
S&F 32 mm dia PVC waste pipe for wash basin /sinks 800mm long complete all as specified and directed.
S&F in Repair Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connection complete all as specified and directed.
S&F 15mm bore steel water tubing, medium grade, galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
S&F 20mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Dismantling Water tanks, open or closed, hoisted and fixed in position complete all as specified and directed.
S&F 1000 Ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight -210 gm) complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) including curves complete all as specified and directed.
M&L for Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Taking down Chowkhats or frames exc. 1.5 sq. m but n. exe 4 sqm (without taking off shutters from the frames each complete all as specified and directed.
S&F solid PVC Door frame of size 50 mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening complete all as specified and directed.
S& F Factory made Solid PVC Moulded Door Shutter with Particle Boarde core, 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2 mm thick Moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F 100 mm long Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed.
S&F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S& F 150 mm Aluminium handles, cast type, anodised fixed complete all as specified and directed.
S&F in repair stop valves/angle valve, cast copper alloy, screwed down, high pressure with crutch or butter fly handles, screwed both ends for iron pipe 15mm dia, fixed complete all as specified and directed.
M&L for Cement concrete Type D2 1:4:8(40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat acrylic primer on surfaces walls complete all as specified and directed.
M&L for providing Cement Concrete type C11:3:6 using 20mm graded stone aggregate as , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L Providing precast cement concrete as in manholes covers 1:2:4 mix type B1, using 20mm graded stone aggregate set in CM 1:4 complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for water proofing treatment of roof slab all as specified below :- (a) Roughening/dismantling surfaces of old concrete floor/roof on concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. (b) M&L for brushing neat cement slurry with 3 Kg, of cement per square metre as directed. (c) Preparation of roof surface by brushing cleaning and M&L for applying 10mm thick plaster in CM 1:4 with water proofing compound @ 2% by weight of cement. (d) Applying a priming coat with bitumen primer @ 0.30 Kg/Sqm. (e) Applying a hot blown bitumen grade 85/25 @ 1.20 kg/Sqm. (f) Laying polymeric water proofing membrane 3 mm thick and weighing not less than 3 Kg/Sqm. (Note: WPC shell be measured and paid separately) .
Applying two coats of aluminium paint @ 100 gm /sqm (each coat) complete all as specified and directed.
M&L for Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site Upto 75mm average complete all as specified and directed.
M&L for Providing and applying Reebaklens RR, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before micro concreting or patch repair, having Specific Gravity 1.16-1.22. Reebaklens RR Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2-2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as specified and directed.
M&L for Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale , rust free rust free surface obtained by grit blasting or suitable means , to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT or as per direction of Engineer-In charge.
M&L for Providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc,. The bonding agent shall be applied by brush & should remain in tacky state after application for a minimum period of 5-6 hrs at 20 deg C & 2-3 hrs at 30 deg C. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. Item rate is inclusive of materials all labour, tools and tackles. complete as per specification and as directed by Engg.-in-charge. Product shall have Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days.
M&L for Providing and applying Renderoc SP40 shrinkage compensated fiber reinforced polymer modified wet spray repair mortar on the prepared surface and curing with curing compound.The repair mortar used shall be single component and shall be mixed with water at water powder ratio of 0.18 and shall have drying shrinkage < 1000 microstrain as per ASTM C 157-93; compressive strength > 40 MPa ; Flexural Strength > 7 Mpa as per ASTM C 348, bond strength > 6 MPa as per ASTM C 1042, etc complete. Product used shall have CE (CE-29842) marking and compliance according to Construction Products Directive 89/106/EE complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in foundation , raft, footing, plinth beam, base for column etc complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in column complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in roof beams, chajja lintle etc complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in slabs supported on walls, beams and column in floors, roof, landings, balconies, canopies, deck slab and in shevels for almirah the like similar work etc complete all as specified and directed.
M&L Formwork to side of concrete foundation footing base of column raft beam and plinth beam with required gap filler etc complete all as specified and directed.
M & L form work to side/bottom of pillars , post , column, beam, slab square , rectangular or polygonal required gap filler etc complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, in fair finished complete all as specified and directed.
M& L form work to sofits of suspended slabs such as roof slabs,floors slabs,landings/chajja and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surfaces of concrete required gap filler complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, oncrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work for fair and smooth surface exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L hardcore of gauge exc.63 mm but not exc 100 mm deposited , spread and levelled in layers n exc. 15 CM thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L 20 mm Rendering / beraring plaster with CM (1:4) over brick/concrete surface fair & even surface complete all as specified and directed.
M&L12 mm Rendering with CM (1:6) over brick/concrete surface other than surface fair & even surface complete all as specified and directed.
M&L for Rendering 5 mm thick (1:3) cement and sand mortar on ceiling complete all as specified and directed.
M&L two coat of synthetic enamel paint over new prepared steel surface but over red oxide primer complete all as specified and directed.
M & L PCC Type B-1 (1:2:4) 12.5 mm graded with water proofing compound for damp proof plinth course incl all form mould etc complete all as specified and directed. (Note:- WPC shall be measured separately)
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified and directed.
M&L 75mm thick PCC (1:3:6) type C1 using 20mm graded stone agg as in plinth protection/Path/paving surface even and smooth and exposed edges fair or rounding or chamfering laid in panels with and including all necessary form work and filling the joints with mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand (all by weight) complete all as specified and directed.
M & L Two coats of cement base paint over coat of primer over new prepared wall surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L Three coat of W/W over newly plastered on ceiling surfaces complete all as specified and directed.
S&F PVC (SWR) Pipe of 110mm dia any length and joint as specified complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
S&F 110mm dia PVC(SWR)pipes bends any radious with acces door complete all as specified and directed.
M&L 10mm thick rendring with CM (1:4) over roof surface even and smooth mixed with WPC complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
S & F 1.25 mm thick Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type including springs/bearings/lock/lath as required complete all as specified and directed.
S & F steel ventilators with top hunh shutter & glazing bars hinges, steel peg stay etc dovetailed or welded, size and thickness of members confirming to IS 1038 complete all as specified and directed.
M&L 3mm thick ordinary quality sheet glass and glazing with oil putty and clip pin in square not exc 0.5 Sqm in each pane complete all as specified and directed.
Excavation over area n.exc. 1.50m deep and getting out in soft/loose soil complete all as specified and directed.
All as per item No 92.00 above but depth exc 1.5m but n.exc. 3.00m.
All as per item No 92.00 above but depth exc 3.00m but n.exc. 4.50m.
M&L cement concrete in surface channels and drains type B1 1:2:4 complete all as specified and directed.
M&L for old size brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:6 complete all as specified and directed.
M&L reinforced cement concrete (design mix) M-25 in baffle walls, walls any thickness including pilasters and buttress complete all as specified and directed.
M&L for rolled section as in framing for cladding, glazing, man hole frame and the like fixed with angle cleats and connecting plate, etc with Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
M&L for form work to surfaces of walls, baffle walls and similar work vertical or to batter frough finished surfaces of flat concrete surfaces complete all specified and directed.
M&L reinforced concrete pipes class NP2 with one collar per lenth of pipe 150 mm bore, laid and jointed complete all specified and directed.
M & L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all specified and directed.
Forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all specified and directed.
S&F PVC SWR Pipes 75 mm dia, Single socketed in any length with rubber ring joints fixed in septic tank complete all specified and directed.
S&F PVC Vent cowl 75 mm complete all specified and directed.
Removing excavated material exc 250 m but n.exc 500 m and depositing where directed in soils complete all specified and directed.
M&L loose filling with broken bricks 80 to 150 mm in soakage wells complete all specified and directed.
M&L for 100mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate)as in flooring complete all as specified and directed.
M&L for salt glazed stoneware pipes in drain/sewage line of Grade 'A' (dia 150mm) including jointing complete all specified and directed.
M&L for Concrete bed 1:3:6 type C-2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC conduit shall be used without any extra cost.
All as per item No 112.00 here in before but for One 3 pin socket outlet 5 amps on the same board with other switches complete all as specified and directed.
All as per item No 112.00 here in before but for One 3 pin socket outlet 5 Amps on independent board complete all as specified and directed.
All as per item No 112.00 here in before but with cable FRLSH size 4 Sq mm for one 15 Amps / AC socket out let with multistrand insulated copper earth continuity conductor FRLSH of size 4 sqmm, complete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fixing Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body com-plete complete all as specified and directed.
Supply and fixing socket out let, 6 pin 5 and 15 amps multipurpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
S & F stepped type electronic fan regulator socket type ISI marked on the existing phenolic laminated sheet etc. as required, complete all as specified and directed.
S&F ceiling rose , PVC/polycarbonate,, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
Supply and fixing in repair Lamp holder/angle holder insulated body with black/white plate for batten fittings including LED bulb 7 watt, complete all as specified and directed
Supply and fixing in replacement LED light fitting with high out put diffuser 4 feet, 20 watt 220 V AC, LUMEN < 2000 with lumen efficacy 120 lumen/watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including connecting up with three core flexible copper conductor cable of size 0.75 sqmm three core with suitable size flexible PVC conduit including taking down of old unsv light, complete all as specified and directed.
Supply and fixing in replacement underwater LED light fitting 18 watt with high out put diffuser cool/warm white suitable for underwater Lamp with polycarbonate housing & integrated electronic driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in replacement of LED Flood light 120 watt, outdoor type, with IP 65 protection comprises of a pressure dia cast aluminium housing, heat resistance toughened glass/ polycarbonate, LED lenses, surge protector, BIS electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 4 sqmm , single core as required for connections etc including taking down of old unsv light, complete all as specified and directed.
Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting including taking down of old unsv light, complete all as specified and directed.
Dismantling, taking down existing ceiling fan and re-fixing & connecting up including provision of cable from ceiling rose or connector to fan including replacement of down rod, hanging clamp, PVC canopy, nut, bolts and suitable size flexible PVC conduit complete all as specified and directed.
Supply & fixing in repair/replacement of sheet metal enclosure Vertical TPN DB 4 Way double door As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, With provision for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing including taking down of old unsv DB and MCBs, complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole, 160 Amps, 50 Hz, Icu=16 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard, complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 12 way ISI marked complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 4 way ISI marked complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SP 40-63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Material and labour for Submain wiring with two single core FRLSH 1.5 sqmm copper conductor, PVC insulated, multi stranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 1.5 sqmm PVC insulated multi stranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly including taking down of old unsv sub-main wiring complete all as specified and directed. Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
Submain wiring with two single core FRLSH 6 sqmm copper conductor, PVC insulated, multi stranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 6 sqmm PVC insulated multi stranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly including taking down of old unsv sub-main wiring complete all as specified and directed. Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
Submain wiring with four single core FRLSH 10 sqmm copper conductor, PVC insulated, multi stranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 10 sqmm PVC insulated multi stranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly including taking down of old unsv sub-main wiring complete all as specified and directed. Note:- four single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
M&L in replacement of earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40mm GI pipe medium grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering, GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
Supply and laying in replacement of XLPE insulated, armoured heavy duty electric cable with alumini-um conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 Core in trench/floor/on pole/wall including taking down of old unsv service wire/cables, complete all as specified and directed.
Supply and laying in replacement of XLPE insulated, armoured heavy duty electric cable with alumini-um conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 Core in trench/floor/on pole/wall including taking down of old unsv service wire/cables, complete all as specified and directed.
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, laying of pipes & cable etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with ap-proved excavated soil in-cluding spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material (soils) to a distance n.exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed.
Supply and lay HDPE pipe medium class, ISI Marked double wall corrugated as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
Supply only Water testing kit for Ph value, Chlorine & turbidity test complete all as specified and directed.
Supply and installation commissioning & testing in repair of Hypochloride solution dozing system incl supply of 100 litre hypo solution with min 6% chlorine content with metering type dozing pumps 02 Nos of rating 0-6 LPH & pump MOC of PP, single phase, service tank 100 Ltrs capacity 3 layer with mounting arrangement, including all plumbing work with all fittings / valve etc complete all as specified and directed.
Supply and fixing ceiling fan (copper winding), 1200mm sweep, minimum BLDC (Brush Less Direct Current Energy saving ceiling fan of size 1200 mm sweep, 230 Volts, 50 Hz power consumption is less than 28 watt, 5 star rated noiseless motor operation, inverter stabilization technology, 370 RPM, 210 cum/min complete with standard accessories i.e (three blade, 02 Nos canopy, down rod of length 1.5 mtr to 2.0 mtr long, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound, including electrically connecting from ceiling rose to fan connector with 0.75 sqmm stranded copper conductor three core flexible cable with suitable size flexible PVC conduit complete all as specified and directed.
Supply and lay HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 50 mm including all fittings complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 40 mm to 90 mm bore HDPE pipe of any description below/under existing road surfaces / floors at a level not less than 0.60 metre etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , con-nected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed. Note :- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
VISHESH BUILDERS
3Krishna Enterprises
Balaji Associates
R K SINGH AND CO
Gupta Automobiles
SahaDevSingh Constructions
Attar Singh and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .