Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.7 L+₹22,474.40 (1.67%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹14.9 L+₹1.5 L (11.1%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹15.0 L+₹1.5 L (11.5%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹15.2 L+₹1.7 L (13.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
10 Aug 2020, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
REPAIR OR REPLACMENT OF DBS, SUBMAIN WIRING, METER BOXES,SERVICE CABLES AND REPAIR OR MAINT OF SECURITY OR STREET LIGHTS, SOLAR LIGHTS AND CONNECTED WORK AT MIRAN SAHIB UNDER GE JAMMU
2020_MES_360399_1
GEJC-30/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Class E category b i
8 documents required · 8 mandatory
₹500
GE Jammu
₹46,000
Yes
29 Oct 2020
13 Jul 2020
12 Aug 2020
13 Jul 2020
10 Aug 2020
27 Jul 2020
Amount
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep any type of soil getting out and levelling of bottom surface to required level for poles/stay assembly/cable all as specified and as directed.
M&L for road cutting, PCC hard standing with width 0.4 & depth 0.9 mtr including excavation for laying of GI pipe and making good the disturbed surfaces all as per existing surface all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25m thick all as specified and directed.
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point all as specified and as directed.
M&L in replacment of GI Pipe light grade 40 mm bore for cable protection as a guard pipe complete all as specified and as directed.
M&L Sub class 'B' bricks well burnt laid with length perpendicular to the axis of the cable in trenches for protection to cable complete all as specified and as directed.
Supplying & Laying in trenches Clear Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified and as directed.
Taking out/down unserviceable, defective cable any Type/size including disconnecting all the electrical connections all as required at site and all as specified and as directed.
Taking out existing UNSV/Old steel/MS angle iron frame or MCB DB,s any size from the wall by dismentalling bricks and making the surface good complete with brick works, plaster, white wash, patch work matching with existing colour all as specified and directed.
Taking out serviceable electric meter from the panel board after disconnecting all incoming/outgoing connection carefully and refixing the same in position all as specified and as directed.
Taking down old and unserviceable submain wiring any size of two core & incldung earth wire complete including batten/conduit any type (concealed/surface) and make good the disturbed surface to match the existing surface, all as specified and as directed by Engr-in-charge.
Taking down old and unserviceable, distribution board SPN, TPN of any type including fuses, MCCBs etc after removing all connection and make good the disturbed surface all as specified and as directed by Engr-in-charge.
Supplying and fixing PVC flat serviceable cable 10 sqmm 2 core multi stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and as directed.
Supplying and fixing PVC flat serviceable cable 16 sqmm 2 core multi stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and as directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sq mm, 2 core, laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sq mm, 4 core, laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sq mm,3.5 core, laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engr-in-Charge.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engr-in-Charge.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engr-in-Charge.
M&L distribution board double door sheet steel phosphatised powder painted for MCB/DB with copper bus bar and neutral link earthing stud TPN 4 way 415 volts double door all as specified and as directed.
S&F in replacement TP & N vertical load line double door DB with 200 Amps bus bar, 415 Volt sheet metal enclouser suitable for G frame MCCB, 4 way all as specified and as directed.
S&F in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed maganatic setting of cap 125 Amps 10KA all as specified and as directed.
S&F in replacement Isolator 4 Pole, TPN 415 volts, 100 Amps rating with rupturring cap 10 KA, complete all as specified and as directed.
S&F in replacement for MCB TP&N 63 Amps 415 Volts. 'B' series rupturring capacity 10 KA complete all as specified and as directed by Engr-in-Charge.
S&F in replacement for MCB SP 6 to 32 Amps,240 Volt B Series all as specified and as directed.
S&F in replacement for MCB SPN 32 Amps 240 Volts, 'B' series complete all as specified and as directed.
S&F in replacement for MCB SPN 40 Amps 240 Volts, 'B' series complete all as specified and as directed.
S&F in replacement for MCB SPN 63 Amps 240 Volts, 'B' series complete all as specified and as directed.
M&L in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 4.0 Sqrmm for earth wire unsheathed , multistranded , copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall all as specified and as directed. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note : Wiring shall be done in proper colour coding.
M&L in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 4 Sqrmm for phase and neutral and one run of 2.5 Sqrmm for earth wire unsheathed , multistranded , copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note : Wiring shall be done in proper colour coding.
M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
Supply and fixing in replacement of PVC enclosure DP complete with MCB SPN 32 Amp 10 KA 230 volt all as specified and directed.
Supply and fixing in replacement of sheet steel cable and box (bus-bar) 4 way 440 volt,50 Hz single door with 200 Amp rated bus bar mounted on insulator all as specified and as directed.
M&L for replacement of MCCB 4 Pole, current rating 630 Amp, thermal setting adjustable 70%-100% rapturring capacity 50kA at 415V, 50Hz, suitable for existing size of panel shutter frame as per site fitment complete all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB 4 Pole, current rating 400 Amp, thermal setting adjustable 70%-100% rapturring breaking capacity 50kA at 415V, 50Hz, suitable for existing make/capacity complete all as specified and directed by Engr-in-charge.
M&L for in replacement of MCCB 4 Pole, current rating 250 Amp, thermal setting adjustable 70%-100% breaking capacity 36kA at 415V,50Hz, suitable for existing make/capacity complete all as specified and directed by Engr-in-charge.
M&L for in replacement of MCCB 4 Pole, current rating 200 Amp, thermal setting adjustable 70%-100% breaking capacity 25kA at 415V,50Hz, suitable for existing make/capacity complete all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB 4 Pole, current rating 160 Amp, thermal setting adjustable 70%-100% breaking capacity 25kA at 415V,50Hz, suitable for existing make/capacity complete all as specified and directed by Engr-in-charge.
M&L for replacement of PVC insulated and sheathed cable of size 1.5 sqmm 3 core aluminium conductor multistranded 1100 volt grade 230 volts complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of LT underground XLPE Cable insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 10 Sq mm, 4 core complete all as specified and as directed.
S & F and fabrication Street light bracket made out of GI tubing light grade suitable for 45/60/90 watt LED light upto 1.2 mtr length, bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
Labour for repair/maint to Old/Unserviceable LED security/Street/flood light of any capacity incl taking down existing fitting from pole/Bldg for replacement of unsv driver,cable terminal block and connection wire and refixing the same in position after repair incl testing all as specified and directed by Engr-in-Charge. Note: Spares shall be measured and paid seperately under respective item.
Supply and fixing in replacement of electronic driver of cap 45 watt of existing make for LED street light fitting complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of electronic driver of cap 60 watt of existing make for LED street light fitting complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of electronic driver of cap 90 watt of existing make for LED street light fitting complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of electronic driver of cap 120 watt of existing make for LED street light fitting complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of electronic driver of cap 200 watt of existing make for LED Flood light fitting complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable Street/Security light fitting of any type from the pole/bldg after disconnecting electric connection carefully complete all as specified and directed.
S & F of Energy Saving Endura Cityliner, LED street light fitting 120 watt comprising a single piece, environment friendly light fittings including electrinic driver, luminaire housing is of pressure die-cast alluminum alloy LM24 for gear and extruded aluminium lamp housing, operating Voltage range is from 85 Volts to 264 Volts AC 50 Hz all as specified and as directed.
S & F of Energy Saving Endura Cityliner, LED street light fitting 90 watt comprising a single piece, environment friendly light fittings including electrinic driver, luminaire housing is of pressure die-cast alluminum alloy LM24 for gear and extruded aluminium lamp housing, operating Voltage range is from 85 Volts to 264 Volts AC 50 Hz all as specified and as directed.
S & F of Energy Saving Endura Cityliner, LED street light fitting 60 watt comprising a single piece, environment friendly light fittings including electrinic driver, luminaire housing is of pressure die-cast alluminum alloy LM24 for gear and extruded aluminium lamp housing, operating Voltage range is from 85 Volts to 264 Volts AC 50 Hz all as specified and as directed.
S & F of Energy Saving Endura Cityliner, LED street light fitting 45 watt comprising a single piece, environment friendly light fittings including electrinic driver, luminaire housing is of pressure die-cast alluminum alloy LM24 for gear and extruded aluminium lamp housing, operating Voltage range is from 85 Volts to 264 Volts AC 50 Hz all as specified and as directed.
S&F of LED flood light fitting of cap 200 watt incl inbuilt surge protection as per requirement LED flood light fittngs along with IP 65 protection all as specified and as directed.
Supply and fixing in replacement of electronic LED bulb 20 watt light fitting complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete with MCCB and accessories all as specified and as directed.
S&F SMC Pole mounted box of size 10"x 8"x 4" with hinged door incl Clamp, nuts, bolts and washers, Make:- Syntex or equivelent of Hansel / Press fit complete with all as specified and directed and including follwing accessories:- (a) MCB SP 10 Amp, 10 kA 'C' Series mounted on din rail -1 No. (b) Connector block suitable for 3ph, 4 wire min 16 sqmm cable-1 No
Repair/maint/service to solar street light fitting of any make and models by replacing unserviceable drivers PCB, LED Lights internal circuits,repair/recharging battery 12 Volts,cleaning to solar panel and painting to pole with two coat aluminium paint complete all as specified and make the light serviceable. Note: Spare shall be measured and paid separately.
Supply only PCB all as specified and as directed.
Supply only LED lights 15/25 W 230 Volt, PF 0.95 and lux more than 95 lumen/watt all as specified and as directed.
Supply only control gear box LED Light all as specified and as directed.
Supply only lithium ion battery suitable to existing solar light panels all as specified and as directed.
M/S Bali Agencies
Vishesh Engineers
Hi Tech Engineers
M/s. Aggarwal Engineers
M/S ESS ESS ENTERPRISES
BMMJ TRADERS AND ENGINEERS
SUMEET TRADING CORPORATION
Harsh Electricals
Bidder Name
Vishesh Engineers
M/S ESS ESS ENTERPRISES
BMMJ TRADERS AND ENGINEERS
Sarbat Construction Co
SUMEET TRADING CORPORATION
M/S Bali Agencies
Hi Tech Engineers
Harsh Electricals
M/s. Aggarwal Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .