Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | ₹25.1 L Quoted ₹25.3 L | L1 | Accepted-AOC L1 quoted rates are satisfactory |
| 2 | L2₹28.8 LRejected-Finance | ₹28.8 L | L2 | Rejected-Finance Greater Than L1 |
| 3 | L3₹28.9 LRejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | ₹28.9 L | L3 | Rejected-Finance Greater Than L1 |
| 4 | L4₹29.6 LRejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹29.6 L | L4 | Rejected-Finance Greater Than L1 |
| 5 | L5₹29.8 LRejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | ₹29.8 L | L5 | Rejected-Finance Greater Than L1 |
| Sl No | Description | Qty | Unit | Tejas Enterprises L1 | Shree Ayyappa Engineering L7 | MAHIMA CONSTRUCTION L5 | MUKTI ENTERPRISES L2 | SAI SERVICE L10 | ICON AGENCIES L11 | M/s S.D Construction Co L4 | M/S. RUDRA ENTERPRISES L8 | NAGESHWAR ELECTRICALS L6 | NAVJEEVAN ENTERPRISES L9 | SHAILENDRA B TULSANI L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & fix exhaust fans steel body AC single phase 230/ 240 V of size 450 mm sweep with louver complete all as specified and directed by Engineer-in-Charge.Note:- Cost of making hole for Exhaust fan of required size at site is deemed to be included in quoted rates. | 38 | Each | 5,490 ₹2.1 L | 8,800 ₹3.3 L | 7,800 ₹3.0 L | 2,500 ₹95,000 | 9,200 ₹3.5 L | 9,000 ₹3.4 L | 6,200 ₹2.4 L | 5,500 ₹2.1 L | 7,930 ₹3.0 L | 6,000 ₹2.3 L | 4,795 ₹1.8 L |
| 2.00 | Supply & fix exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed by Engineer-in-Charge.
Note:- Cost of making hole for Exhaust fan of required size at site is deemed to be included in quoted rates. | 17 | Each | 2,000 ₹34,000 | 4,000 ₹68,000 | 6,000 ₹1.0 L | 2,900 ₹49,300 | 4,150 ₹70,550 | 6,200 ₹1.1 L | 4,600 ₹78,200 | 3,550 ₹60,350 | 2,860 ₹48,620 | 3,300 ₹56,100 | 3,050 ₹51,850 |
| 3.00 | M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed by Engineer-in-Charge.
One Exhaust Fan point controlled by one switch | 30 | Point | 540 ₹16,200 | 700 ₹21,000 | 550 ₹16,500 | 650 ₹19,500 | 815 ₹24,450 | 1,890 ₹56,700 | 690 ₹20,700 | 720 ₹21,600 | 510 ₹15,300 | 820 ₹24,600 | 20 ₹600 |
| 4.00 | All as per item No 03 here-in-before One light point controlled by one switch | 214 | Point | 540 ₹1.2 L | 700 ₹1.5 L | 525 ₹1.1 L | 650 ₹1.4 L | 820 ₹1.8 L | 490 ₹1.0 L | 700 ₹1.5 L | 750 ₹1.6 L | 510 ₹1.1 L | 850 ₹1.8 L | 630 ₹1.3 L |
| 5.00 | All as per item No 03 here-in-before One Ceiling Fan point controlled by one switch | 58 | Point | 540 ₹31,320 | 700 ₹40,600 | 525 ₹30,450 | 650 ₹37,700 | 820 ₹47,560 | 470 ₹27,260 | 700 ₹40,600 | 735 ₹42,630 | 510 ₹29,580 | 800 ₹46,400 | 630 ₹36,540 |
| 6.00 | All as per item No 03 here-in-before One 3 pin socket outlet, 5 Amp independent | 67 | Point | 540 ₹36,180 | 700 ₹46,900 | 550 ₹36,850 | 650 ₹43,550 | 820 ₹54,940 | 450 ₹30,150 | 700 ₹46,900 | 715 ₹47,905 | 510 ₹34,170 | 790 ₹52,930 | 650 ₹43,550 |
| 7.00 | All as per item No 03 here-in-before One 3 pin socket outlet, 5 Amp on the same board with other switches | 49 | Point | 210 ₹10,290 | 200 ₹9,800 | 200 ₹9,800 | 300 ₹14,700 | 175 ₹8,575 | 560 ₹27,440 | 690 ₹33,810 | 170 ₹8,330 | 147 ₹7,203 | 230 ₹11,270 | 225 ₹11,025 |
| 8.00 | All as per item No 03 here-in-before One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size | 4 | Point | 540 ₹2,160 | 700 ₹2,800 | 525 ₹2,100 | 650 ₹2,600 | 815 ₹3,260 | 520 ₹2,080 | 690 ₹2,760 | 750 ₹3,000 | 510 ₹2,040 | 700 ₹2,800 | 660 ₹2,640 |
| 9.00 | All as per item No 03 here-in-before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed by Engineer-in-Charge. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately). | 112 | Point | 590 ₹66,080 | 940 ₹1.1 L | 750 ₹84,000 | 740 ₹82,880 | 985 ₹1.1 L | 1,900 ₹2.1 L | 890 ₹99,680 | 900 ₹1.0 L | 580 ₹64,960 | 850 ₹95,200 | 850 ₹95,200 |
| 10.00 | M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x2.5 sq. mm +1 x2.5 sq. mm earth wire earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:-Two run of 2.5 sqmm wire and One run of 2.5 sqmm wire and One run of PVC casing caping will be measured as one running meter. | 960 | RM | 281 ₹2.7 L | 200 ₹1.9 L | 240 ₹2.3 L | 205 ₹2.0 L | 225 ₹2.2 L | 290 ₹2.8 L | 280 ₹2.7 L | 200 ₹1.9 L | 298 ₹2.9 L | 300 ₹2.9 L | 189 ₹1.8 L |
Updated dates
Tender Value
₹33.1 L
EMD Value
₹66,300
Closing Date
5 Jan 2026, 6:00 pmClosed
Gaurav Tiwari, IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
PROVN OF DEFICIENT CEILING FANS EXHAUST FANS INTERNAL WIRING AND COOLING APPLIANCES AT EE HALL ROOM AND VARIOUS MESSES SWIVEL LIGHTS AT WATCH TOWERS FLAME PROOF LIGHT AND EXHAUST FANS AT MT POL STORE AND LIGHT FACILITY AT MT TEST POINT AND BRAZIN
2025_MES_743490_1
GE/LONAVLA/8395/E8
Open Tender
Civil Works
180 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (I) (NAVY) LONAVLA
₹66,300
Yes
14 Mar 2026
6 Dec 2025
7 Jan 2026
6 Dec 2025
5 Jan 2026
22 Dec 2025
6 Dec 2025 - 20 Dec 2025
All as per item No 03 here-in-before One light point controlled by one switch
All as per item No 03 here-in-before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed by Engineer-in-Charge. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x2.5 sq. mm +1 x2.5 sq. mm earth wire earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:-Two run of 2.5 sqmm wire and One run of 2.5 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x1.5 sq. mm +1x1.5 sq. mm earth wire earth wire of FRLS is PVC insulated copper conductor, s
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed by Engineer-in-Charge.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x4 sq. mm +1x4 sq. mm earth wire earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .
ingle core cable in surface/recessed as required . Note:- Three run of 1.5sqmm wire One run of PVC casing caping will be measured as one running meter.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_832509.xls
BOQ • 0.49 MB
Tenderdocu8395final.pdf
Tender Documents • 0.98 MB
Download all tender documents and submit your bid