| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹23.8 L+₹56,939 (2.45%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹24.7 L+₹1.4 L (6.03%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹25.4 L+₹2.1 L (9.10%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹32.9 L+₹9.6 L (41.3%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
22 May 2024, 6:00 pmClosed
GE Amritsar
GE Amritsar PIN 143001
REPAIR/MAINTENANCE OF INTERNAL WIRING DBs AND FITTING FIXTURES INCLUDING DAY TO DAY MAINTENANCE AT MD ACCN IN THE AREA OF AGE BR-I UNDER GARRISON ENGINEER AMRITSAR CANTT.
2024_MES_651000_1
GE/ASR-06/2024-25
Open Tender
Civil Works
Works
180 days
GE Amritsar
class D category b i
8 documents required · 8 mandatory
₹500
Yes
GE Amritsar
₹90,000
21 Sept 2024
24 Apr 2024
23 May 2024
24 Apr 2024
22 May 2024
9 May 2024
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, sockets, lamp holders, brackets etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and white / colour wash etc. ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for Point wiring for One light / One fan / One bell point controlled by one, one way switch.with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through an existing metallic/ rigid PVC concealed conduit including replacement of pressed steel terminal mounting box for mounting fitting like switches, sockets, and provinding covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 1.50 sqmm size as a earth wire and connected to common earth dolly ; Complete all as specified and directed by the Engineer-in-charge.
Material and Labour for Point wiring for One socket outet point 5 amps on the same board point controlled by one, one way switch.with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through an existing metallic/ rigid PVC concealed conduit including replacement of pressed steel terminal mounting box for mounting fitting like switches, sockets, and provinding covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 1.50 sqmm size as a earth wire and connected to common earth dolly ; Complete all as specified and directed by the Engineer-in-charge.
Material and Labour for Point wiring for One socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board controlled by one, one way switch.with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through an existing metallic/ rigid PVC concealed conduit including replacement of pressed steel terminal mounting box for mounting fitting like switches, sockets, and provinding covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 1.50 sqmm size as a earth wire and connected to common earth dolly ; Complete all as specified and directed by the Engineer-in-charge.
Material and Labour for Point wiring for One socket outlet 16 Amps 6 pin controlled by one, one way switch on independent board controlled by one, one way switch.with 2.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through an existing metallic/ rigid PVC concealed conduit including replacement of pressed steel terminal mounting box for mounting fitting like switches, sockets, and provinding covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers with & including one continuous run of PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked (green colour) of 2.50 sqmm size as a earth wire and connected to common earth dolly ; Complete all as specified and directed by the Engineer-in-charge.
Material and Labour for point wiring for one light point / fan point / bell point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One socket outet point 5 amps on the same board , controlled by one, one way switch with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One socket outlet 6pin 16Amp controlled by one, one way switch on independent board (independent point), controlled by one, one way switch with 2.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 2.50sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One light/one fan/one bell point controlled by one, one way switch on independent board (independent point) for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through an existing metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover plates for mounting fitting like modular switches, modular sockets,modular fittings and brass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One modular socket outet point 5 amps on the same board controlled by one, one way switch for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through an existing metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover plates for mounting fitting like modular switches, modular sockets,modular fittings and brass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One modular socket outlet 5 pin 5Amp controlled by one, one way switch on independent board controlled by one, one way switch for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through an existing metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover plates for mounting fitting like modular switches, modular sockets,modular fittings and brass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One modular socket outlet 3 Pin , 16Amps controlled by one, one way switch on independent board controlled by one, one way switch for modular fittings with 1.50sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn through an existing metallic/ rigid PVC concealed conduit including replacement of Metal boxes and modular accessories like cover plates for mounting fitting like modular switches, modular sockets,modular fittings and brass screws and cup washers including 2.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories ; Complete all as specified and directed by Engineer-in-charge. All as Ser item 12 here in before but with 2.5 sq mm wire and earth wire (green colour) of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet.
Material and Labour for point wiring for one modular light point / fan point / bell point (independent point), controlled by one, one way modular switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and metal terminal boxes for mounting fitting like modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover plate fixed including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One modular socket outet point 5 amps on the same board, controlled by one, one way modular switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and including metal terminal boxes for mounting fitting like modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover plate fixed including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One modular socket outet point 5 amps 3 pin on the independent board, controlled by one, one way modular switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and including metal terminal boxes for mounting fitting like modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover plate fixed including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring for One modular socket outet point 16amps 3 pin on the independent board, controlled by one, one way modular switch with 2.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 25 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and including metal terminal boxes for mounting fitting like modular switches, modular sockets, lamp holders, sketch fittings and covered with modular cover plate fixed including one continuous run of PVC insulated 2.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush button single pole one-way 5 Ampere ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing of switch piano flush button single pole one-way 15 Ampere ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Modular switch 6 Amp 1 way 1 module size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Modular switch 16 Amp 1 way with indicator 1 module size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Modular socket shuttered 6 Amp 2/3 pin combined 2 module size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Modular socket 16Amp multipurpose type 2 module size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Modular Fan regulator step type 120 watts 2 Module size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing of single phase call bell ‘DING DONG’, AC 230 volts single pole fixed over and including pressed steel sunk box of size 175 X 100 mm duly covered with 3 mm thick bakelite sheet ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing bell push, flush type, single pole 5 amps ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs metal enclosure (plug & socket type DB) complete including double pole enclosure with two pin, earth plug and socket complete with one SP MCB C Curve type of capacity 20 Amp, 10 KA ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ curve type ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs MCB double pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for IR testing of exesting internal wiring including sub main wiring for each quarters with megger 500 volts ; Complete all as specified and directed by Engineer-in-charge. Note : 1. The equipments required for testing will be arranged by the contractor and the cost of the same is including in quoted rates. 2. The results sheet duly signed by the User, Contractor, JE E/M & AGE E/M will be submitted to GE with recommendation of Engineer-in-charge.
Supply and Fixing in repairs sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 4 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating surface mounting SPN 12 way , 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc ; Complete all as specified and directed by Engineer-in-charge. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
Supply and Fixing in repairs MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB with and incl 100 amp 25 kA 4 pole MCCB with thermal - magnetic setting including Suitable type MCB with blank plate including taking down old MCCB all as specified and directed ; Complete all as specified and directed by Engineer-in-charge. (Note : The cost of removing old wooden/steel box etc and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
Material and Labour for sub main wiring with 1100 volt grade two single core FRLSH Wire PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit medium grade not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring ; Complete all as specified and directed by Engineer-in-charge. NOTE: 3 single core 6 sqmm and PVC conduit shall be measured as one RM.
Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 10 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark medium grade FRLS, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 10 sqmm multi - stranded copper conductor as earth wire in green colour Including taking down old unserviceable sub main wiring ; Complete all as specified and directed by Engineer-in-charge. NOTE: 3 single core 10 sqmm and PVC conduit shall be measured as one RM.
Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 16 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark medium grade FRLS, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 16 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring ; Complete all as specified and directed by Engineer-in-charge. NOTE: 3 single core 16 sqmm and PVC conduit shall be measured as one RM.
Material and Labour for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 4 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark medium grade FRLS, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 4 sqmm multi - stranded copper conductor as earth wire in green colour including taking down old unserviceable sub main wiring ; Complete all as specified and directed by Engineer-in-charge. NOTE: 2 run of 4 sqmm & 1 run of 4 sqmm as earth wireand PVC conduit shall be measured as one RM.
Supply and Fixing wall /ceiling mounting LED 18 Watt pride plus/smart line tube light fitting complete with all acessories 1x18 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs wall /ceiling mounting LED 9 Watt tube light fitting complete with all acessories 1x9 Watt LED , with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz, and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs decorative Gate light fitting made up of high grade unbreakable polycarbonate material suitable for 9 watt LED lamp (B-22 base) including one Nos LED bulb 9 watt with ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs energy saving new generation 10 watt LED built up, 6000k bulk head luminaire with opal diffuser light fitting complete with all acessories and connection ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs fan regulator electronic step t& socket size and making all necessary connections ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour as in repairs for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on ; Complete all as specified and directed by Engineer-in-charge. Note : - (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. (iii) Earthing work will be done by contractor ub presence of JE /Engr-in-Charge, the earthing work carried in absence JE /Engr-in-Charge will not neasured & paid for the same. (iv) All earthing material will be approved before bulk procurement and got approved from Engr-in-Charge
Supply and Fixing in repairs ceiling mounting fitting LED type 36 W fitted in 2x2 ceiling including PVC wire upto 1.5 mtr from ceiling rose to fitting ; Complete all as specified and directed by Engineer-in-charge.
Material and labour in repairs service connection PVC cable 10 Sqmm 2 Core incl GI wire and PVC conduit for fixing in wall /pole incl connection ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs LED flood light fitting 50 Watt with high pressure die cast housing IP65 protection single phase supply including connection with PVC wire ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs post top lantern LED fitting 15 Watt including LED bulb high grade unbreakable polycarbonate suitable for LED bulb including connection with PVC wire ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs bell push, Module type, single pole 5 amps complete ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs LED Blub 9 Watt pin type 220 Volts including connection ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs Ceiling light fitting 12 Watt as per sample including connection ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repairs LED Blub Thread 9 Watt threat type 220 Volts including connection ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for testing of exesting Earthing with earth megger 100 Volts complete with spikes wires etc ; Complete all as specified and directed by Engineer-in-charge. Note : 1. The equipments required for testing will be arranged by the contractor and the cost of the same is including in quoted rates. 2. A register of tests (Earth test ,IR) shall be maintained by the JE E/M and results shall be entered into a register, which will be signed by the User, Contractor , JE E/M and AGE E/M. 3. The results sheet duly signed by the User, Contractor, JE E/M & AGE E/M will be submitted to GE with recommendation of Engineer-in-charge
SUN MANN ENGINEERS
Bharat Builder
kailu construction co
M/s MAHAJAN CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .