CWE AF JAISALMER
HQ CWE AF JAISALMER RAJ
REPAIRS/MAINTENANCE OF DUCTABLE AC PLANT, CENTRAL AC PLANT AND ASSOCIATED WORKS AT AF STN UTARLAI
2019_MES_293140_2
80087/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF UTARLAI
CLASS E CAT c(i)
7 documents required · 7 mandatory
₹500
Yes
GE AF UTARLAI
₹49,700
Yes
27 Feb 2020
8 Nov 2019
7 Dec 2019
8 Nov 2019
6 Dec 2019
21 Nov 2019
Amount
Inspection of ductable split type AC of any capacity of any type by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and servicing, cleaning/removing the dust and filter, blower, fan motor, compressor, wasing/ cleaning the outer surface and testing including making good surface/ ceiling if necessary checking of refrigerant standing pressure complete all as directed by Engineer-in-Charge. Note: (i) New spare parts/items required in replacement in replacement of old defective spare parts/items shall be measured and paid separately under respective items.(ii) Refrigerant required for topping (R22 / R-134/ R410(a) shall be measured and paid for separately (iii) Cost of transportation of air conditioner required being repair/replacement from site to workshop for repair ,and refix at site after repair shall be deemed included in quoted rates.
Replacement of unserviceable blade for condensing fan motor of capacity 3/4 TR in ductable split type AC.
Replacement of unserviceable blade for condensing fan motor of capacity 5.5 /7.5TR in ductable split type AC.
Replacement of unserviceable foam type insulating flexible pipe & air tight outer tapping fitted on ACs of any capacity for suction / discharge copper tubes in ductable split type AC.
S&F in repairs condenser fan motor of ductable split type AC of 3 TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs condenser fan motor of ductable split type AC of 4 TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs condenser fan motor of ductable split type AC of 5.5TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs condenser fan motor of ductable split type AC of 7.5 TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs blower fan motor of ductable split type AC of 3 TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs blower fan motor of ductable split type AC of 4 TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs blower fan motor of ductable split type AC of 5.5TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs blower fan motor of ductable split type AC of 7.5TR capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S & F in repairs starting capacitor, for ductable split type AC of capacity 80-100 Mfd Complete all as directed. Make : EPCOS /ASIAN /Sarada.
S&F in repairs of old unsv/damage cooling coil with new cooling coil for air conditioner of cap 7.5 ton capacity, complete all as specified and directed by engineer-in-charge make Hitachi and existing sample or approved by engr-in-charge.
S&F in repairs of old unsv/damage cooling coil with new cooling coil for air conditioner of cap 5.5 ton capacity, complete all as specified and directed by engineer-in-charge make Hitachi and Existing sample or approved by engr-in-charge.
S&F in repairs scroll type Compressor (Sealed Unit) of ductable split type air conditioner of capacity 5.5 TR, three phase, 440 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification including gas charging R-22 testing complete to the entire satisfaction of Engr-in-charge.
S&F in repairs Rotary type Compressor (Sealed Unit) of ductable split type air conditioner of capacity 2.5 TR, three phase, 440 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction.
S&F in repairs Rotary type Compressor (Sealed Unit) of ductable split type air conditioner of capacity 2.0 TR, three phase, 440 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction.
M & L for Refrigerant gas R 22/ in company sealed cylinder of capacity all as directed by Engr-in-charge.
M & L for Refrigerant gas R-410(a)/407 (a) in company sealed cylinder of capacity all as directed by Engr-in-charge.
S&F in repairs 3 phase contactor 415 Volt 50 HZ 5.5 KW coil Voltage 220 Volt make Siemens / L&T / C&S for ductable split type AC 5.5 Ton TR after disconnecting & dismantling existing unserviceable contactor all as directed.
All as per item 21 above but ductable split type AC of 7.5 TR capacity.
S & F in repairs PCB Sensor unit with wire remote control of ductable split AC indoor unit of Capacity 3 TR suitable for ,Hitachi removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge.
Description all as per item No 23 above but ductable split type AC of 4 TR capacity.
Description all as per item No 23 above but ductable split type AC of 5.5 TR capacity.
Description all as per item No 23 above but ductable split type AC of 7.5 TR capacity.
S & F in repairs PCB outdoor unit with wire of ductable split AC out door unit of Capacity 5.5TR suitable for ,Hitachi removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge.
S & F in repairs PCB outdoor unit with wire of ductable split AC out door unit of Capacity 7.5TR suitable for ,Hitachi removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge.
Material and labour for flushing out system , checking and rectification of leakages if any and make it serviceable including flushing with nitrogen gas to cold charging line condenser coil and cleaning the blower unit ,filter for ductable package type AC complete all as specified & as directed by Engineer-in-Charge.
M & L for removing the burned out copper coil from wall mounted Stabilizer of capacity 8/10 KVA and rewinding of coil assy with superenamelled copper wire as per existing gauge and varnishing complete with E class varnish, including replacement of MCB, Fuse assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge.
S&F in repairs for replacement of out door unit body suitable space for fixing of condenser coil 3, 4 & 5.5 TR capacity painting with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive paint inside the Body etc complete all as specified and directed by engineer-in-Charge .
S&F in repairs for replacement of out door unit body suitable space for fixing of condenser coil cap 7.5 TR capacity painting with two coats of anti corrosive paint inside the Body etc complete all as specified and directed by engineer-in-Charge .
S&F in repairs of mounting assembly suitable for AC condensing fan motor of 3,4 & 5.5 TR capacity with fan motor .
S&F in repairs of mounting assembly suitable for AC condensing fan motor of 7.5 TR capacity with fan motor .
S&F in repairs of old unsv/damage condensing coil with new condensing coil for air conditioner of cap 5.5 ton capacity, complete all as specified and directed by engineer-in-charge make as per sample or approved by engr-in-charge.
S&F in repairs of old unsv/damage condensing coil with new condensing coil for air conditioner of cap7.5 ton capacity, complete all as specified and directed by engineer-in-charge make as per sample or approved by engr-in-charge.
S & F in repair of safety valve of 3,4, 5.5 & 7.5 TR Split type ductable AC compressor line as per existing makes and sizes complete all as specified and directed by Engr -in- charge .
Supply & fix PVC cable flexible round 3 Core Copper conductor 4 sqmm . Make :-L&T,Finolex
Replacement of refrigent pipe or tube (copper) for ductable split type AC of size 1/2" complete all as specified directed by Engr -in- charge.
Supply and fix in replacement of Micro processor based PCB card and display unit for 37.5 TR capacity make AC plant complete all as specified and directed by Engineer-in-charge. Make: - Blue star model : XWC3539DX
Supply and fix in replacement of Micro processor based PCB card and display unit for 56.5TR capacity AC plant complete all as specified and directed by Engineer-in-charge. Make: - Voltas. Model : ACWCDS 064DPWN3 X 1
Supply and fix in repair Drier Filter suitable for ductable type AC Plant size 5/8" complete all as specified and directed by Engineer-in charge. Make: Dasfoss / Indofoss.
M&L repair of Humidity control system of any capacity for installed at AHUs including control wiring and replacement of un-serviceable heater and thermostat connected material complete all as specified and directed by Engineer-in-charge.
S&F in Replacement of AHU filter EV-4 model complete all as specified and directed by Engineer-in-charge.
M&L Repair/servicing greasing etc of Condenser/Chiller Pump of cap 5 to 7.5 HP after taking down and re-fixing the same at its existing location with proper alignment after replacing accessories as under: - (a) Gland bush , studs, nuts & washers (b) Ball bearing of pump set (c) Re-melting grinding and polishing of pump shaft as per existing size and shape complete. (d) Gland packing, greasing in pump bearings and making its proper alignment etc
M&L Repair/servicing greasing etc of Condenser/Chiller Pump of cap up 3 HP after taking down and re-fixing the same at its existing location with proper alignment after replacing accessories as under: - (a) Gland bush , studs, nuts & washers (b) Ball bearing of pump set (c) Re-melting grinding and polishing of pump shaft as per existing size and shape complete. (d) Gland packing, greasing in pump bearings and making its proper alignment etc
S&F Repair in LP cut off control cut out 12 volt suitable for 10 TR, 37.5 TR & 56.5TR AC of capacity complete all as specified and directed by Engineer-in-charge. Make: - Danfoss / Indo Foss
S&F repair HP cut off control cut out 12 Volt suitable for 10 TR, 37.5 TR & 56.5TR AC of capacity complete all as specified and directed by Engineer-in-charge. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F repair LP sensor 12 volt suitable for Scroll type AC of capacity10 TR, 37.5 TR & 56.5TR complete all as specified and directed by Engineer-in-charge. Make: - Danfoss / Indo Foss or equivalent make as approved by GE.
S&F repair HP Sensor 12 Volt suitable for 10 TR, 37.5 TR & 56.5TR AC of capacity complete all as specified and directed by Engineer-in-charge. Make: - Danfoss/Indo Foss or equivalent make as approved by GE.
S&F repair 3 Pole contactor 50 A Single Phase coil voltage 220 V 50 Hz with NO-NC complete all as specified and directed by Engineer-in-charge.
Repair and maintenance of thermal insulation with thermocol 50 mm thick and width not exceeding 200mm covered with chicken wire mesh and 10 mm CM 1:6 on the top Edge at Supply and return pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair Expansion valve suitable for 37.5 & 56.5 TR AC plant complete all as specified and directed by Engineer-in-charge. Make: - Danfoss or equivalent make as approved by GE.
S&F in repair Air release valve for chiller plant complete all as specified and directed by Engineer-in-charge.
S&F in repair cranguage heater for chiller plant complete all as specified and directed by Engineer-in-charge.
S & F in repair Single phase preventer Make: Minilec /GIC suitable for 37.5 & 56. 5 TR AC plant complete all as specified and directed by Engineer- in - Charge.
S&F in replacement AHU belt of suitable size as per Existing belt complete all as specified and directed by Engineer-in-charge.
S&F in repair inlet/outlet sensors suitable for 10 TR, 37.5 TR & 56.5TR of capacity AC plant complete all as specified and directed by Engineer-in-charge.
M & L cleaning in strainer and filter at main suction pipe line complete all as specified and directed by Engineer-in-charge.
S&F in repair service(leakage) valve of size 5/8 complete all as specified and directed by Engineer-in-charge.
S&F in replacement AHU Motor Pulley for existing make and size complete all as specified and directed by Engineer-in-charge.
Repair/ Maintence of insulated piping and valves for chilled water piping of 100mm dia.
Repair/ Maintence of insulated piping and valves for chilled water piping of 75mm dia.
S & F in repair Thermostat of 0-50 Degree.
Supply, installation, testing and commissioning of Duct thermal insulation compressing with 50mm FGP with factory made Aluminum foil all as specified and directed by Engr -in- charge.
Ditto all as per item No 65 above but Duct thermal insulation with 75mm thermcool, sand cement plaster(External Duct).
Ditto all as per item No 65 above but under deck insulation with 50mm grade expended polystyrene 18Kg density.
S & F in replacement of 4 core 4 Sqmm copper cable for chilled water and condenser water pump and cooling tower.
Disconnecting electrically / mechanically from the system, removal, lowering to the ground unserviceable reciprocating type compressor Make: Danfoss 13 TR Capacity, operated onR 407c/ R410a gas and 3 phase 415 volts electric supply for repair. Transportation to civil workshop & vice versa. Strip opening the compressor carefully, identifying the serviceable / unserviceable spares/ parts for replacement / machine work etc. to make it fully functional at designed RPM & torque, reassembling the same, placing to the same position, connecting it electrically & mechanically, testing to its full load capacity complete all as specified and directed by Engineer-in-Chrage. Note : Parts and refrigerant shall be measured and paid for separately under relevant items.
S&f in repairs Shaft Seal Assembly for reciprocating type compressor 13 TR capacity operated on R 407c/ R410a gas and 3 phase 415 volts electric supply.
Ditto all as per item No 70 above but S&f in repairs Rocker Arm (Single Frame).
Ditto all as per item No 70 above but S&f in repairs Piston with pin and Ring and Lock.
Ditto all as per item No 70 above but S&f in repairs Main End Bearing 1mm.
Ditto all as per item No 70 above but S&f in repairs Big/Small End Bearing.
Ditto all as per item No 70 above but S&f in repairs Connecting Rod.
Ditto all as per item No 70 above but S&f in repairs Suction Reeds with pressure springs.
Ditto all as per item No 70 above but S&f in repairs Discharge Reeds with pressure springs.
Ditto all as per item No 70 above but S&f in repairs Gasket kit complete SMC 4x100.
Ditto all as per item No 70 above but S&f in repairs Neoprene "O" Rings set complete.
Ditto all as per item No 70 above but S&f in repairs Sleeve (Cylinder) stainless steel.
Ditto all as per item No 70 above but S&f in repairs Suction Valve assembly.
Ditto all as per item No 70 above but S&f in repairs Discharge Valve assembly .
Ditto all as per item No 70 above but S&f in repairs Auto Capacity Control .
Ditto all as per item No 70 above but S&f in repairs Safety Valve assembly .
Ditto all as per item No 70 above but S&f in repairs Connecting Rod Pin.
Ditto all as per item No 70 above but S&f in repairs Connecting Rod GM bush .
Ditto all as per item No 70 above but S&f in repairs Aluminum Ring (Dowdy Ring).
Ditto all as per item No 70 above but S&f in repairs Piston Ring Set .
Disconnecting electrically / mechanically from the system, removal, lowering to the ground unserviceable reciprocating type compressor Make: Danfoss 16TR Capacity, operated onR 407c/ R410a gas and 3 phase 415 volts electric supply for repair. Transportation to civil workshop & vice versa. Strip opening the compressor carefully, identifying the serviceable / unserviceable spares/ parts for replacement / machine work etc. to make it fully functional at designed RPM & torque, reassembling the same, placing to the same position, connecting it electrically & mechanically, testing to its full load capacity complete all as specified and directed by Engineer-in-Chrage. Note : Parts and refrigerant shall be measured and paid for separately under relevant items.
S&f in repairs Shaft Seal Assembly for reciprocating type compressor 16TR operated on R 407c/ R410a gas and 3 phase 415 volts electric supply.
Ditto all as per item No 90 above but Rocker Arm (Single Frame).
Ditto all as per item No 90 above but Piston with pin and Ring and Lock.
Ditto all as per item No 90 above but Main End Bearing 1mm.
Ditto all as per item No 90 above but Big/Small End Bearing.
Ditto all as per item No 90 above but Connecting Rod.
Ditto all as per item No 90 above but Suction Reeds with pressure springs.
Ditto all as per item No 90 above but Discharge Reeds with pressure springs.
Ditto all as per item No 90 above but Gasket kit complete SMC 4x100.
Ditto all as per item No 90 above but Neoprene "O" Rings set complete.
Ditto all as per item No 90 above but Sleeve (Cylinder) stainless steel.
Ditto all as per item No 90 above but Suction Valve assembly.
Ditto all as per item No 90 above but Discharge Valve assembly .
Ditto all as per item No 90 above but Auto Capacity Control .
Ditto all as per item No 90 above but Safety Valve assembly .
Ditto all as per item No 90 above but Connecting Rod Pin.
Ditto all as per item No 90 above but Connecting Rod GM bush.
Ditto all as per item No 90 above but Aluminum Ring (Dowdy Ring).
Ditto all as per item No 90 above but Piston Ring Set .
M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (hydrochloric acid) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 2x10 TR all as specified and as directed(Logistic & BTF ).
M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (hydrochloric acid) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x37.5 TR all as specified and as directed(Auditorium).
M&L for evacuation of gas from the system, de-scaling the condenser ,supply & circulating the descaling solution (hydrochloric acid) with pump, brushing the tubes and wherever required drilling the stubborn scaling without damaging the tubes, replacement of gaskets and unserviceable nuts & bolts assembling back complete testing complete for AC plant of capacity 3x 56.5 TR-WSA Shed 3 specified and as directed.
Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 10 TR capacity ( BTF,Logistic).
Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 37.5 TR capacity (Auditorium).
Opening the upper sheet and side sheet of AHU’s of the following plants for access to cooling coil, M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing AHU of AC plant of capacity for AC plant 56.5 TR capacity WSA).
M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, restoring the leaks including S&F replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for AC plant Auditourium,WSA,BTF and Logistics.
Supply & filling of compressor oil standard quality all as specified & directed.
Opening the upper sheet / side sheet of Cooling tower Cleaning, servicing of Chiller type AC Plant of any capacity / model / make for access to reserve water tank, cooling fan & cooling fins etc, M&L for washing/cleaning of cooling tower internally/ externally including cooling fins etc with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing all as specified and as directed.
Dismantling of unserviceable monoblock pumpset 3 phase 415 volts, upto 5 HP at suitable for monobloc pump/AHU/Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, taking out burnt stator winding with out damage to stator body, rewinding the eclectic motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc including transportation to civil workshop and vice -versa complete all as specified and directed by Engineer-in-Chrage.
Dismantling of unserviceable centrifugal pump set couple type three phase 415 volts, upto 7.5 HP at suitable for monobloc pump/AHU/Compressor etc of any model/Make, strip opening and taking out or rotor carefully, cleaning of rotor and stator, taking out burnt stator winding with out damage to stator body, rewinding the eclectic motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete, assembling the motor including replacement of studs with nuts, testing of motor to its full load capacity at desired RPM/torque after coupling with pumpset etc including transportation to civil workshop and vice -versa complete all as specified and directed by Engineer-in-Chrage.
M & L for repair & testing of monoblock pumping set electrically operated with motor 7.5HP/5KW, 9LPS with stainless steel Impeller, mechanical seal system and stainless steel shaft suitable for operation with electric driven motor suitable for 415Volt, 50Hz, 3 Phase, AC supply including connection cable of copper conductor of suitable size including taking up old unserviceable existing pumps and depositing to MES store yard complete all as specified and as directed by Engineer-in-Charge. Make : CROMPTON GREAVES/ KIRLOSKER/Havell's. Note (i) PCC plate form shall not be measured and paid separately. (ii) The cost of MS bracket of channel angle iron including nut bolt and washers and welding as required for fixing arrangement of mono block pumping set shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account. (iii) Ant vibration pad shall also be included in the unit rate of this item.
Supply and fixing and installation of new Butterfly valve conforming to/ ISI marked, flanged both edges suitable for 80 mm bore pipe, including rubber joints, nuts, bolts, gaskets & washers, testing complete including taking out old /unserviceable valve complete all as specified and directed by Engineer-in-Charge.
Supply and fixing and installation of new Butterfly valve conforming to/ ISI marked, flanged both edges suitable for 150 mm bore pipe, including rubber joints, nuts, bolts, gaskets & washers, testing complete including taking out old /unserviceable valve complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing water pressure gauge 96mm dia as per existing pressure for chiller / condenser pipeline testing complete including taking out old /unserviceable gauged complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Suction / Discharge gauge 65mm dia as per existing pressure for chiller / compressor Refrigerant pipeline testing complete including taking out old /unserviceable gauged complete all as specified and directed by Engineer-in-Charge.
S&f in repairs Indicator lamp color RYB suitable for control panels including necessary wiring.
S&F in repairs of old unsv/damage condensing coil with new condensing coil for air conditioner of cap 3 ton capacity, complete all as specified and directed by engineer-in-charge make as per sample or approved by Engr-in-charge.
S&F in repairs of old unsv/damage condensing coil with new condensing coil for air conditioner of cap 4 ton capacity, complete all as specified and directed by engineer-in-charge make as per sample or approved by Engr-in-charge.
National Rewinding Works
M/s Pankaj Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .