Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | ₹36.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹42.5 L+₹6.2 L (17.1%)Rejected-Finance | ₹42.5 L+₹6.2 L (17.1%) | L2 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | somyaenterprises L2 | J.K & Company L1 |
|---|---|---|---|---|---|
| 1.00 | Taking out sunken submersible pump set of any description and any capacity from existing bore wells of any depth and any dia all as directed by Engineer-in-Charge.
NOTE: 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Cost and expenditure of lifting out column pipe and submersible cable shall be paid for separately under schedule 'A'. Incase contractor fails to recover/taking out the sunken submersible pump sets from borewell, no payment shall be made to the contractor. | 6 | Each Job | 4,500 ₹27,000 | 2,500 ₹15,000 Lowest |
| 2.00 | Lowering down of the submersible pump set after repair of any description and any capacity & in any position, in bore well alongwith column pipe of existing dia and submersible cable of any size (approximately 60 mtr depth of pump set from GL) complete all as specified and directed by Engineer-in-Charge including making necessary electric connections & testing the pump set after lowering.
NOTE: 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost.
2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes/pump sets/submersible cable and making necessary connections and including reconnecting water supply system. The required materials like column pipes/ /submersible cable/pump sets etc (new/old retrieved materials) shall be provided by the department to contractor for fixing and lowering in bore wells) | 6 | Each Job | 4,200 ₹25,200 | 2,500 ₹15,000 Lowest |
| 3.00 | Supply only galvanised iron water tube 100mm bore in 3 meter length , heavy grade, ISI marked, conforming to IS-1239 (latest) for column pipe in required length but each length not more than 3.00 mtr, both end screwed with long threads/ flanged complete all as specified and directed.
(NOTE: Fixing and jointing of the column pipes with sockets/flanfge, nut bolt wasers, rubber gasket are deemed to be included in the rates quoted by the contractor for lowering of the column pipes with pump sets) | 150 | RM | 1,100 ₹1,65,000 Lowest | 1,280 ₹1,92,000 |
| 4.00 | Development of bores in well position with using suitable air compressor of suitable pressure (not less than 250 CFM) and capacity as approved for obtaining optimum yield and for obtaining sand free water including cast of material and labour , T & P etc for developing complete all as specified & directed. | 72 | Hr | 1,100 ₹79,200 | 700 ₹50,400 Lowest |
| 5.00 | Development of bore well by over pumping with minimum 25% higher capacity of pump set after development with compressor complete all as specified and directed. | 72 | Hr | 1,250 ₹90,000 | 650 ₹46,800 Lowest |
| 6.00 | Yield test for tube well with the help of notch tank 90 degree by continuous pumping to determine safe pumping yield. | 4 | Job | 5,000 ₹20,000 Lowest | 5,000 ₹20,000 Lowest |
| 7.00 | Draining out water from OHT by operating wash out valve ,Cleaning of over head tank (staging from 6 meter to 18 Meter) (inside) by scraping with the help of hard brushes and physical cleaning of over head tank (reservoir) by descaling / brooming silt and other deposit in side (bottom of dome). collecting and taking them out with help of manual labour and depositing not exceeding 50mtr all as directed. Cleaning of inner surface of OHT by applying the bleaching powder solution (1:10) and left it for 1/2 hour for making surface algee/ bacteria free .clean the surface with water and drying it quick with the help of electric air blower. Applying two coat of thick quick drying lime wash on entire surface (inner) top and bottom including writting date of cleaning with white paint on back painted surface two places and painting of inner steel ladder of tank all as specified and directed by Engr-in-Charge:- | 3 | Each Job | 5,000 ₹15,000 | 4,000 ₹12,000 Lowest |
| 8.00 | S&F in replacement MCCB 200 Amp 4 pole 36 KA 415 Volt complete all as specified and directed. | 4 | Each | 8,500 ₹34,000 Lowest | 8,800 ₹35,200 |
| 9.00 | S&F in replacement MCCB 160 Amp 4 pole 36 KA 415 Volt complete all as specified and directed. | 3 | Each | 8,000 ₹24,000 | 4,900 ₹14,700 Lowest |
| 10.00 | S&F in replacement MCCB 100 Amp 4 pole 16 KA 415 Volt complete all as specified and directed. | 3 | Each | 6,500 ₹19,500 | 4,500 ₹13,500 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
15 Dec 2025, 6:00 pmClosed
GE Kapurthala
GE Kapurthala
Repair/maintenance of Bore well and OHT connect of water supply work at Mil Stn Beas under GE Kapurthala.
2025_MES_741277_1
8105/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹98,000
5 Mar 2026
24 Nov 2025
17 Dec 2025
24 Nov 2025
15 Dec 2025
8 Dec 2025
Amount
Taking out sunken submersible pump set of any description and any capacity from existing bore wells of any depth and any dia all as directed by Engineer-in-Charge. NOTE: 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Cost and expenditure of lifting out column pipe and submersible cable shall be paid for separately under schedule 'A'. Incase contractor fails to recover/taking out the sunken submersible pump sets from borewell, no payment shall be made to the contractor.
Lowering down of the submersible pump set after repair of any description and any capacity & in any position, in bore well alongwith column pipe of existing dia and submersible cable of any size (approximately 60 mtr depth of pump set from GL) complete all as specified and directed by Engineer-in-Charge including making necessary electric connections & testing the pump set after lowering. NOTE: 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes/pump sets/submersible cable and making necessary connections and including reconnecting water supply system. The required materials like column pipes/ /submersible cable/pump sets etc (new/old retrieved materials) shall be provided by the department to contractor for fixing and lowering in bore wells)
Supply only galvanised iron water tube 100mm bore in 3 meter length , heavy grade, ISI marked, conforming to IS-1239 (latest) for column pipe in required length but each length not more than 3.00 mtr, both end screwed with long threads/ flanged complete all as specified and directed. (NOTE: Fixing and jointing of the column pipes with sockets/flanfge, nut bolt wasers, rubber gasket are deemed to be included in the rates quoted by the contractor for lowering of the column pipes with pump sets)
Development of bores in well position with using suitable air compressor of suitable pressure (not less than 250 CFM) and capacity as approved for obtaining optimum yield and for obtaining sand free water including cast of material and labour , T & P etc for developing complete all as specified & directed.
Development of bore well by over pumping with minimum 25% higher capacity of pump set after development with compressor complete all as specified and directed.
Yield test for tube well with the help of notch tank 90 degree by continuous pumping to determine safe pumping yield.
Draining out water from OHT by operating wash out valve ,Cleaning of over head tank (staging from 6 meter to 18 Meter) (inside) by scraping with the help of hard brushes and physical cleaning of over head tank (reservoir) by descaling / brooming silt and other deposit in side (bottom of dome). collecting and taking them out with help of manual labour and depositing not exceeding 50mtr all as directed. Cleaning of inner surface of OHT by applying the bleaching powder solution (1:10) and left it for 1/2 hour for making surface algee/ bacteria free .clean the surface with water and drying it quick with the help of electric air blower. Applying two coat of thick quick drying lime wash on entire surface (inner) top and bottom including writting date of cleaning with white paint on back painted surface two places and painting of inner steel ladder of tank all as specified and directed by Engr-in-Charge:-
S&F in replacement MCCB 200 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 100 Amp 4 pole 16 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 63 Amp 4 pole 16 KA 415 Volt complete all as specified and directed.
S&F phase sequence corrector in sheet metal enclosure with phase loss protection system working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 45 HP pump working voltage 440 Voltage etc complete all as specified and directed.
M&L for disconnecting electric connection and pipe connection and taking out submersible pump & motor of capacity 12.5 to 17.5 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same guage and weight to existing including replacement of , Motor bush, thrust plate coupling complete with key and alignment of motor stater's slote reassembnling the motor with pump and lowering it into bore well making it functional and testing complete all as specified and directed by Engr-in-Charge.
All as per item 13 above here in before but capacity 25 to 30 HP
All as per item 13 above here in before but capacity 35 to 45 HP of turbine motor pump including replacerment of ball bearings.
All as per item 13 above here in before but capacity 100 HP of turbine motor pump including replacerment of ball bearings.
All as per item No 13 here in before but for pump motor of capacity 10 HP including replacement of ball bearings and alignment of motor starter and slote.. .
All as per item No 13 here in before but for submersible pump motor of capacity upto 7.5 HP including replacement of ball bearings and alignment of motor starter and slote.. .
Repair / replacment of unserviceable part of submersible pump capacity 12.5 to 17.5 HP such as gun metal bush impeller assembly remetaling/turning to shaft, locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional all as specified.
All as per item No 19 here in before but for submersible pump for capacity 25 HP to 30 HP.
All as per item No 19 here in before but for non clog submersible pump for capacity 35 HP to 45 HP.
All as per item No 19 here in before but for openwell submersible pump motor of capacity 2 to 7.5 HP including replacement of ball bearings and alignment of motor starter and slote.. .
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 10 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 16 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
S&F aviation light LED type fixed on the top of OHT of any height including necessary fixing accessories complete all as specified and directed.
Taking down GI pipe line from trench/wall/floor/roof stacking it reuse or issued to contrctroctor as credit of following sizes
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 32mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
GI pipe of 80mm/100mm bore
Refixing old retrived srviceable GI pipe line on trench/wall/floor/roof of following sizes
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 32mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
GI pipe of 80mm/ 100mm bore
Supply and fixing GI tubing medium grade in any length with all fitting laid in trench/wall/floor/roof and connecting up with water supply main complete all as specified and directed
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 32mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
GI pipe of 80mm bore
GI pipe of 100mm bore
Taking down CI pipe line from trench stacking it reuse or issued to contrctroctor as credit of following sizes
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
Refixing old retrived srviceable CI pipe of any description in trench of following sizes
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
Supply and fixing CI pipe in any length laid in trench and connecting up with water supply main complete including jointes all as specified and directed
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
Taking down old unserviceable DI (K-7) pipe 100 mm bore and supply, laying, jointing and testing new DI (K-7) pipe 100 mm bore centrifugally cast class LA confirming to IS - 1536 spigot and socketed ends in any length laid in trenches complete all as specified and directed. (Note : QUOTED rate deemed to be including DI fitting and new run lead joint.
All as per item No 32 above here in before but DI (K-7)150 mm bore
Supply and fixing in replacement cast iron fitting such as bends, tapers, (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, single branch for spigot and socket and flanged pipe up to 150 mm bore complete all as specified and directed.
Supply and fixing in replacment cast iron sluice valve 80 mm bore with flanged ends, ISI mark with Gun metal spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified
All as per srl item No 35 here in before but 100 mm dia.
All as per ser item No 35 above here in before but 150 mm bore
M & L valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
M&L for lead joint suitable for CI pipe 80 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 100 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 150 mm bore complete all as specified and directed.
Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified.
All as per item ser No 42 above here in before but 25 mm bore
All as per item ser No 42 above here in before but 32 mm bore
All as per item ser No 42 above here in before but 40 mm bore
All as per item ser No 42 above here in before but 50 mm bore
M &L for earth work in trenches / pit and bailing out water to rectfying leaking joint of CI pipe spigot and socket type 80 mm bore including pouring extra lead chieseling and levelling the excavated material after rectifying the leakage complete all as specified.
All as per item ser No 47 above here in before but 100 mm bore
All as per item ser No 47 above here in before but 150 mm bore
Supply and fix 10 sqmm 3 core ,Multistranded copper conductor, PVC insulated, PVC shethed, multicore, round flexible industrial CONTROL cable, voltage grade 300/500 volt fixing on wall /floor/roof etc for connecting Over head tank water lavel indicator
Water Level Indicator, Overhead Tank Indicator, Led Indicator for Tank Water, Water Level Displa including y Wired Sensor , Make SKYLET WLC-112 or equvelent
Materila and labour for Painting of all CI pipes, sluice valves of main over head tank with 2 coat of synthetic enemal paint Pipe after applying one coat of primer,marking letters as directed. Note Scope envolve Pipe from Top of Over head tank to Pump House all pipe over the ground in pump house is to be painted all as directed.
Material labour and services for taking sample water in sterilised bottles from various borewells for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories: (i) Physio Chemical Analysis of Water ( Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride) (ii) Microbiological Analysis ( Totral Choliforms , Eschirrchea Coli) Note : 1. A certificate of approval / certification of Lab by Goivt Of India / State Govt shall be submitted by the contractor to the deptt. 2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample
Supply of Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finish Box Make - RMCO
Supply only orthotolidine reagent for chlorine test in 500 ml bottle of make - glaxo / SDS / Ran baxy
Supply& Fixing battery 12 volts 180AH Make Exide/Luminous/Amara raja.
Taking down old u/s bleching dozing pump along with all accessories and Supply and install connecing. Testing and commissioning of High Pressuure single Head adjustable "AQUAFIT" Dosing system Model No VST 1005 and VST 1006 of the following specification. Adjustble High Pressure 5 Kg/Sq. cm. power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, Max output 10 Ltr with mandatory accessories like lead Tubing, connecting ferrules, check valves, etc (A) Preparation tank Model No VST 1005 of net capacity 100 Ltr, FRP dosing tank dia 650 x net Height 375 + conical 300. Gross height with stand 1000 mm consisting of : (i) Water inlet line (ii) Outlet with stainer (iii) Drain (iv) overflow (v) conical bottom for sludge depositing (vi) Pot hole with cover (vii) level gauge (viii) Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller. (B) Service Tank Model No VST 1006 dia 480 x height 575 net capacity 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 900 RPM Single Phase flange mounted moto with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall Make : VARIMA of equivalent CG.
Repair to existing valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 45 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 100 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 15/17.5 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 7.5/10 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
Supply and fixing CI double flanged Non -return valve, class 'B', High pressure PN 1.6 conforming to ISI marked, including bolts, nuts, washer and rubber packing all as specified and directed of the 150mm dia bore:- Make : Kirloskar/BIR/Minar
All as per item No 65 above here in before but 100 mm bore dia
Supply and filling pea gravel of size 3 to 10 mm to a packed thickness into the side of existing bore well (which is hollow space between casing pipe and true bore ) all as directed by Engr-in-charge complete all as specified and directed.
M&L for replacment of pressure gauge 0-100 PSI, dial type fixed on pumping line in various pumps all as specified.
Supply and fixing MS clamp of size 50x6 mm, MS flat iron with one No GI/MS socket of 20mm/15mm duly welded incl nut & bolts for taking branch connection/jointing of branch connection from 40 to 150mm bore line including boring in GI/CI pipe incl rubber packing all as directed.
Material and labour for replacement of unserviceable digital Amp/Volt meter any type with new one
Material and labour for replacement of CT of any ratio with new one
Material and labor for reapir replacemnt of unserviceable wiring of motor control panel with new one
M&L for replacement of repacemnt of unserviceable phase indicator with new one
M&L for replacement of old unserviceable contactor with new one suitable for 3 phase 25 HP pump starter panel
M&L for replacement of old unserviceable contactor with new one suitable for 3 phase 35 HP pump starter panel
M&L for replacement of old unserviceable contactor with new one suitable for 3 phase 40 HP pump starter panel
M&L for replacement of old unserviceable time delay relay (Timmer) with new one suitable for 3 phase 40 HP pump star delta starter panel
M&L for replacement of old unserviceable time delay current limiting relay with new one suitable for 3 phase 25/30/35/40 HP pump star delta starter panel
M&L for single phase preventer suitable for 3 phase motor starter.
M & L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 .
Taking out old defective underground cable from trenches/ floors/road/wall /pipe/ pole LT cable of any size/ description including (Note : Excavation and earth work will be measured separately under respective item)
Supply, Laying, jointing and testing XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade (heavy duty )with stranded aluminium conductor, cross sectional area 10 Sqmm 2 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified. Note (i) Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items.
All as per description of serial item no.82 here in before but cross sectional area 50 Sqmm 3½ core complete all specified.
All as per description of serial item no. 82 here in before but cross sectional area 70 Sqmm 3½ core complete all specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge. (for LT Cable )
Supply& Fixing battery 12 volts 150AH Make Exide/Luminous/Amara raja.
M&L for disconnecting electric connection and pipe connection and taking out submersible pump & motor of capacity 2 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same guage and weight to existing including replacement of , Motor bush, thrust plate coupling complete with key and alignment of motor stater's slote reassembnling the motor with pump and lowering it into bore well making it functional and testing complete all as specified and directed by Engr-in-Charge.
somyaenterprises (BID ID -3498640)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender8105.pdf
Tender Documents • 1.24 MB
BOQ_830044.xls
BOQ • 1.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .