| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 CrAccepted-AOC 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹18.9 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹19.6 CrRejected-Finance MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹19.6 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹20.0 CrRejected-Finance GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹20.0 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹20.1 CrRejected-Finance | ₹20.1 Cr | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹26.1 CrRejected-Finance | ₹26.1 Cr | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹18 Cr
EMD Value
₹12.3 L
Closing Date
17 Feb 2020, 6:00 pmClosed
CHIEF ENGINEER CG GOA
Headquarters Chief Engineer Indian Coast Guard Chicolna, JNC Nagar Road, Bogmalo Post Goa 403806
DEMOLITION OF EXISTING SINGLE STOREY TYPE V AND TYPE IV MARRIED ACCOMMODATION AND CONSTRUCTION OF MULTI STORIED MARRIED ACCOMMODATION AT CGRA RAMESWARAM UNDER GE I CG KOCHI
2019_MES_306953_1
81079/E8
Open Tender
Civil Works
750 days
RAMESWARAM UNDER GE I CG KOCHI
AS PER TENDER PAGES
10 documents required · 10 mandatory
₹3,000
GE (I) (CG) KOCHI
₹12.3 L
Yes
18 Mar 2020
17 Dec 2019
20 Feb 2020
17 Dec 2019
17 Feb 2020
5 Feb 2020
Amount
Sch 'A' Part-I (BUILDING WORKS)Total amount of Sch 'A' Part-I (Buiding)
Sch 'A' Part-I (BUILDING WORKS)Total amount of Sch 'A' part-I A (Demolition of Building )
Total amount of Sch 'A' Part-II ( Site clearence and Development)
Total amount of Sch 'A' part-III (Internal Water Supply)
Total amount of Sch 'A' part-IV (Internal Electrification)
Total amount of Sch 'A' part-V (Road/Path/Hardstanding)
Total amount of Sch 'A' part-VI (Sewage Disposal)
Total amount of Sch 'A' part-VII (Area Drainage)
Total amount of Sch 'A' part-VIII (Lightening Protection)
Total amount of Sch 'A' part-IX (Aviation obstruction light)
Total amount of Sch 'A' part-X (External water supply)
Total amount of Sch 'A' part-XI (External electric supply)
Sch 'A' Part- XII (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
External Water Supply :- Electric driven Multistage mono block centrifugal pump sets set of capable of delivering 11.7 LPS at 45 Meter head coupled with three phase 415 volt 3000 RPM not less than 10 HP complete of cat Part No KDT 1078 Suc. 65mmX Del 50mm of Make Kirloskar Brothers or equivalent model of other manufactures as per list of make. The work also includes the followings:- (a)M&L forLowering of GI suction pipe flanged type heavy grade welded with flange of dia not less than the dia suitble to match the sucttion of pumps from foot valve at suction pit to pumps (b)M&L for of GI dilvery pipe flanged type heavy grade welded with flange of dia not less than the dia suitble to match the pumps from Pump butterfly valve and from butterfly valve to NRV. (c) M&L for MS 'C' chanel for clamp made out of MS flat 100x12 mm for lowering/installation of pump set complete- 02 Nos (c) Supplying, fixing and testing of Brass reflux valve (NRV) of suitable dia flanged joint complete with nuts, bolts and washers complete all as specified.
d) Supply and fixing of slim seal butterfly valve with iron wheel head both ends flanged for iron pipe and fixed complete with nuts, bolts and washers complete all as specified. (e) Pressure gauge diaphragm type up to 50 Kg/Cm2-1 No. (f) M&L for air release valve 15mm (g) Priming arrangements using 25mm CPVC pipe and 01 No PVC tank 500 Ltrs capacity (h)M&L for ball valve 25mm bore
Factory made and tested indoor type pedestal mounted LT feeder pillar box, cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved withg colour code on copper bus bar of rating 200Amps for phases and 100 Amps for neutral fixed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3 mm CRCA sheet and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work both side opening type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings (LT panel for motor starter):-
(Location LT Panel No 4 in side pump house for operation of fresh water) INCOMINGS (a) MCB 32 Amps 10 KA, 4 Pole, fixed type LT 415 V AC grade -01 Nos (b) Digi tal volt meter-01 Nos (c) Digital amp meter with necessery CT PT Coil-01 Nos OUTGOING (a) MCB 25 Amps 10 KA, 3 Pole, fixed type LT 415 V AC -02 Nos b) Phse indicating lamp(Set of three)-01 set (c) Internal wiring of panel with stranded copper cable of suitable size (d) Supplay and fixing star delta starter with over load protection relay, phase reversal protection and all standard relays matching caharecterstic of 10 HP Pump set KDT 1078 Suc. 65 mmX Del 50mm-02 Nos Make of MCB shall be Havells DHMGCTPF0006-32 or equivalent in Legrand/Indoasian/HPL.
Provision of new masonary valve chamber of size 900x900x900mm solid block masonary 200 mm thick over concrete foundation in PCC 1:4:8 D2 100 mm thick,50 mm thick PCC 1:2:4 type B1 in coping including 15 mm thick plastering in cement motor 1:4 for internal surface 15 cm below normal ground level with MS sheet 3.15 thick hinged MS cover with locking arrangements. Lifting handle fitted to 50 X 50 X 6 mm angle iron frame and painting including necessary earth work.
Factory made and tested indoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings accessories
Factory made and tested indoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties (location of the panel: LTP No 2 Generator panel as shown in schematic plan) INCOMING :- (a) On load change overwitch 4 pole 100 Amps 415 Volts 15 Hz - 01 No. Make shall be Havells IHCNFO0100 or equivalent in Legrand/ Indoasian/ HPL. (b) MCCB 100 Amps 18 KA, 4 Pole, fixed type (Icu=100 % Ics) LT 415 V AC grade having microprocessor based release for over current and earth fault protection and interlock trip push button complete IS 2516 marked -02 Nos (1 No in comming & 1 No outgoing for fire pump control panel). Make of MCCB shall be cat No IHLGHF0100#or equivalent in Legrand/Indoasian/HPL. Make of MCCB shall be IHLGHF0100# or equivalent in Legrand/ Indoasian/ HPL
Factory made and tested out door type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties (location of the panel: LTP No 3 Near Type V Md Accn as shown in schematic plan)
LED streetlight fitting EDGE series of LED complete of model No169557 cat part no BRTFG 90W LED of make bajaj or equivalant model of other manufacturer as per list of makes and GI pipe bracket 40mm bore of 1.6 m long complete bent to shape duly calamped with MS Clamps of size 40 x 5mm thick with and including one run of PVC insulated copper conductor wiredrawn through PVC conduit from fitting to FRP box complete allas specified and ditected at site.
FRP pole mounting box of size 150mm x 100mm x200mm with and including MCB SP 6A 10K with characteristic curve C and cable terminal for RYB & N with end caps of same colour code.
XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 185 sq mm complete all as specified and direcetd.
11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 185 sqmm complete all as specified and directed
XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 240 Sq mm with and in cluding cable gland complete all as specified and direcetd
All as per item above ser iten No 24 but 3.5 core 150 Sq mm complete all as specified and direcetd
All as per item above ser iten No 24 but 3.5 core 70 Sq mm complete all as specified and direcetd
All as per item above ser iten No 24 but 3.5 core 50 Sq mm complete all as specified and direcetd
All as per item above ser iten No 24 but 3.5 core 25 Sq mm complete all as specified and direcetd
All as per item above ser iten No 24 but 2 core 10 Sq mm complete all as specified and direcetd
DG Set (Standby Power Supply) :- OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 50 KW/62.5 KVA, air cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Kochi (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,6 cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 50KW/62.5KVA at outdoor atmospheric conditions at Kochi. (Taking all derating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self
no human intervention,rescues during power/system failure with latest IGBT power devices,3D infra red sensor in full length of doors and built in floor announcing system with 03 Nos hand set one each in car, machine room and near ground floor landing door and over load indicator suitable for three phase, 415 Volts,50Hz AC supply for passenger lift including all connected civil works and 2 Nos earthing with & including the following all as specified and directed:- (a)06 Nos LED 03 watt, out of which 03 Nos of light connected to inverter supply and one cabin fan 300mm sweep in lift car (b)Mechanical guide rail in 'T' section with tougue and groove arrangement for smooth operation of car and counter weight. (c)Electric motor AC, 3 phase 415 V, 50HZ of suitable capacity including cabling with FRLS cable including necessary conduits as required.
(d)Type of operation shall be single automatic push button type. (e)Type of control-16 bit micro processor variable voltage and variable frequency (V3F) (f)Type of signal system-Hall button with digital hall position indicator digital car position indicator in acr fixtures in stainless steel face plates.(g)Minimum Size of clear entrance opening of car for passenger lift (884kg capacity ) 900mm (W) X 2000mm (H) with automatic center opening.(h)Minimum Size of car for passenger lift (13 passenger,884 kg capacity)-2000mm (W)x1100(D)x2200mm(H).(j)Automatic rescue device battery operated to bring the car cage to the nearest floor level and auto opening for evacuvation of passengers in the event of power failure. Capacity of ARD battery should be suitable to perform minimum three rescue operation.(k)Earthing shall be connected with suitable size copper earth wire from earth plate to control panel in machine room.(l) Pit Ladder,(m) Hand rail 50mm dia SS 316 L,14 Guage and Looking mirror 5.5mm thick of size 3 ftx3ft (LXB) Make : Saint Gobin/ Atul/MODi or equivalent manufactures listed in list of manufactures.
(l)RCC/PCC foundation all as specified and directed complete with nut and grouting plates etc.(m)Provision of hoist way and governors rope and governor.(n)Provision of new buffer spring as per manufacturers design(o)Provision of battery operated alarm and emergency light through inverter of suitable capacity having power pack up for a period of minimum 30 minutes.(p)Drive-Geared with machine frame fixed in the machine room.(q)Over speed governer monitors the speed and triggers safety gears etc shall be installed in the machine room. Safety Measures:(i) Overload relays (ii) Contactors and fuses.(iii) Electrical terminals high quality (iv) Limit switch with accessories on each doors/cage. (v) Gravity/counter weight limit switches for top most position. (vi) Break motor of suitable size with manned released arrangements.(vii) Phase sequence corrector.(viii) Lift shall match with the standard as specified in IS-14665, (ix) mirror polished 12mm thick black granite facing at entrance of door and at cill and at lintel level, 40cm wide all as specified and as directed. Make of Lift shall be OTIS/SCHNEIDER/MITSVBISHI.
Ditto All as per item No 31 here-in-before complete but lift for 8 passenger, 544 Kg capacity minimum size of clear entrance opening 800 mm width 2000 mm height and minimum car size 1300 width 1100 mm depth x 2200 mm height complete all as specified and directed. Make of Lift shall be OTIS/SCHNEIDER/MITSVBISHI.
FIRE FIGHTING :- Centrifugal pump Electrically driven horizontal end suction centrifugal type confirming to IS-12469, 1988 with CI Casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for contineous operation with range of operation 0% to 150% of rated capacity for 440V, 3 Phase, 50 Hz, 70 Mtr head at 2850 LPM with min pressure of 2 Kg per sqcm discharge pressure to maintain a pressure of 3.0 Kg per sqcm in main line at terrace
Jockey pump horizontal end suction, centrifugal type confirming to IS:12469-1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with non-over loading power characteristic for frequent start/stop operation 440V, 3 phase, 50Hz 70m Head, 180 LPM discharge
Pipe galvanized, “Heavy class”, including fittings, 150 mm (6”) dia
Slim seal type cast iron butterfly valves lever operated type with necessary flanges, nuts, rubber insertion gaskets, nuts and bolts complete. Of size 100 mm
Single hydrant valve of 63 mm dia single headed with instantaneous hose coupling adaptor with ISI mark. confirming to IS : 5290
Hydraulic first aid hose reel complete with swing ttype drum, 19 mm rigid hose having a length of 30 Mtrs with stop cock and SS nozzle confirming to IS 884 on one end and all other necessary fixing materials coupled directly to down commer complete all as sper guide lines of CFEES.
Controlled percolated hose in 15 M length of 63 mm dia and tested to bursting pressure of 15kg/sqcm binded GM/Alum male and female coupling as per IS:8423
Fire yard hydrant stand post 1.5m height 80mm bore with provn of single outlet conforming to IS 908
MS flanged pipe 25mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer
Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories
Hose cabinet of External type to accommodate pipes alongwith one pair of male and female coupling and one branch pipe. The cabinet is made of MS sheet, glass fronted with hinged door and lock. The cabinet is spray painted to scarlet red color outside.
Hose cabinet of internal type to accommodate pipes alongwith one pair of male and female coupling and one branch pipe. The cabinet is made of MS sheet, glass fronted with hinged door and lock. The cabinet is spray painted to scarlet red color outside.
GI branch pipe with 25 mm male hexagonal base nozzle confirming to IS :903 complete all as specified and directed.
Valve, stop, screwed,25 mm (1”) dia pipe complete all as specified and directed.
Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia complete all as specified and directed.
Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete
Pressure switch complete all as specified and directed. Make :- Honeywell/ Danfoss/ Swizer
0-15 kg/sq cm 100m dia Dial type pressure gauge with isolation cock and pipe at hydrant station as per specification complete all as specified and directed.
Inteliigent addressable manual call point with inbuilt turbo Isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra acceesories as required, duly approved by EN54/LPCB/VDS/FM complete all as specified and directed.
Networkcable 2 Loop Micro processor based 2 wire fault tolerant loop with optional redunadant network module ,each loop shall have the cpability of connecting 126devices.The fire alarm control panel shall have built in degarde mode function.The panel should have inbuilt TCP/IP communication for Panel Program and Remote Monitoring option through LAN or WAN communication.The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 2000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display with resolution of 256 X 112 pixels, and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Should have protection caregory of IP30. Also the panel should have the option to operate in manned and unmanned mode.The Panel Shall have 99 Zones with Individual LED Indicators or with in the Loop mimic driver for 96 LED indicators.The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required.and as per specifications and Duly Approved by EN54/LPCB/VDS/FM complete all as specified and directed. Make :- Networkable 2 loop micro processor for fire alarm control panel shall be Honey well/Siemens/Bosch/Ravel/Agni.
2 x 1.5 sq.mm Copper armoured FRLS cable with accessories including glanding complete all as specified and directed.
Electricaly control panel of cubical construction, Wall mounting type, fabricated out of 3.15 mm thick CRCA sheet, with hinged lockable doors, inter connection, having switchgears and accessories mounting and internal wiring, earth terminal, numbering etc, complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply. (Location LTP No 4 for fire fighting panel as shown on schematic panel) (a) 32 Amps. TPN MCB-02 nos Make Havells Cat No DHMGCTNF006032 or equivalent in Legrand/ Indoasian/ HPL. (b) Digital panel multifunction meter.-01 Nos (c) Starter with auto/ manual control-01 No (Exclusively for jockey pump only) (d) Set of 3 phase indicating lamp.-01 Set (e) Automatic opetaion of main pump set(01 No) other than jockey pump set with in 10 seconds while jockey pump is running to meet the required pressure in main line. If the main pump set fails to start with in 10 seconds, run procedure/ program for automatic start operation of Engine driven pump sets to meet the required constant pressure from varring low pressure in main line with in 10 seconds. (f) Digital/ analog display of parameters/ status of engine as under:- (i) Low fuel( The the display should match the corresponing fuel capacityof Engine driven pump set in item No 25) (ii) Over Heat. (iii) low oil pressure. etc and all standard features as per mannufacturers guide lines.
Terrace pumps for 440V, 3 Phase, 50Hz confirming to IS:12469-1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440V, 3 Phase, 50Hz 30m head, 150 LPM discharge
LED emergency Exit sign luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 02 hours (Cat No 111510 Make Bajaj or equivalant model of other manufacturer as per list of makes
Octogonal poles, hot dip galvanised tapered 9 m long with single arm base plate mounted with door opening for electrical connection with all necessary fittings, nuts bolts, washers etc complete all as specified and as directed.
PILE FOUNDATION Boring Cast in situ DMC pile of 800mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials outside MD land complete all as specifioed and directed. Note:- (i) The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii) This item will be executed as per location mrked in drg.
Reinforced cement concrete of grade RMC M-30 design mix as per IS – 456 with using 20mm graded stone aggregate in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile including destructive integrity test on all pile as per IS-14893,2001 part-IV. (Note: The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test)
RCC grade RMC M30 design mix as per IS–456 using 20mm graded stone aggregate in pile caps complete all as specified and shown on drg. Notes for Sl item Nos 62 & 63 :- Reinforcement shall be measured and paid for separately under relevant items of this Schedule.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Ditto All as per item No 64 here-in-before but for pile caps complete all as specified and directed.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over upto and including 12mm dia conforming to IS-1786 as in stirrups for pile caps and grade beams cut to length bent to shape required and binding with mild steel wire (annealed) not less than 0.9mm dia or welding.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5 mm dia end over up to and including 10mm dia conforming to IS-1786 as in Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire or welding .
PCC 1:4:8 type D2 using 40mm graded stone aggregate for concrete layer below pile caps and foundation complete all as specfified and as shown in drg
Formwork to sides of concrte foundation, pile caps rough finished surface of concrete flat. All as specified and as directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation in soft/loose soil for pile cap/plinth beam/tie beam
Excavation in trenches not exc 1.5m wide and exc 1.5m and nox exc 3m in depth for foundation in soft/loose soil for pile cap beam/tie beam
Excavation over area not exc 1.5m in depth for foundation in soft/loose soil for pile cap/plinth beam/tie beam
Excavation over area exc 1.5m and nox exc 3m in depth for foundation in soft/loose soil for pile cap/plinth beam/tie beam
Returning/filling in layers and ramming in layers around pile cap,plinth beam etc using excavated soil incl sprading,levelling,well ramming in layers not less than 25cm thick.
Removing excavated material exc 1.5Km n.exc 5Km and depositing where directed at a level n.exc 1.5m above starting point
Testing of piles (Initial Load test) all as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 800mm dia cast in situ pile.
Testing of piles (Routine Load test) all as per IS for 800mm dia Cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
Precast cement concrete block masonry with solid blocks exc. 10cm in width and setting in mortar, complete
Internal Electrification :- Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- (NOTE: Switch and socket to be measured and paid for separately):-
a) One light/Ceiling Fan/exhaust fan / bell point controlled by one 5/6 amps one way switch.
(b) One Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin.
(c) One Socket outlet, three/five pin, 5 Amp, same board controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin.
(d) One light point controlled by 2 Nos, 2 Way switches 5/6 Amps.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent:-
Ceiling fan 1400mm sweep copper wound having minimum 5 star rating , including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/ connector to fan . Make : Bajaj Cat No Kassels 50ISI or equivalent in Usha/ Crompton/ Havells.
Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound having minimum 5 star rating and including complete all as specified and directed at site. Make : Bajaj Cat No Maxima DX or equivalent in Usha/ Crompton/ Havells
LED Tube light 1X20 Watt Havells Cat Part No LHEWEBP7IN1W/020 or equivalent model of other manufacturer as per list of makes.
Sleek LED mirror light 1X10 Watt Make : CG Cat Part No LCL-10-CDL or equivalent model of other manufacturer as per list of makes.
Decorative wall light fitting made of polycarbonate suitable for 1x10 Watt suitable for B-22 base including 1x10 Watt LED Lamp. (Make : Havells Cat Part No LHDL02160099 or equivalent model of other manufacturer as per list of makes.
Metra plug and socket with DB for MCB's including provision of MCB SP 25A 240 Volt for A/C point.
Street light fitting pressure die cast aluminium housing heat resistance toughtned glass having IP 66 protection of 25 Watt complete including fixing with GI Bracket made of 43mm dia GI Pipe including fixing clamps etc complete. (Make Havells 25W LED IP66 security light Model No.LHETAXU7PA6J025 or equivalent model of other manufacturer as per list of makes.
Bulk head fitting LED, 230 Volt including LED 10 Watt complete with open diffuser make Havells cat No LHEOAP07UZ6W010n or equivalent model of other manufacturer as per list of makes.
Decorative surface mounted chorme finish 2x2 LED 10 fixture flat panel glare free lighting (Make Havells cat No LHEWEBP7NL1W036 or equivalent model of other manufacturer as per list of makes.
Vertical DB 12 way,TPN, double door including MCCB 4 Pole 200 Amps, 35KA as incomer, IP 43 protection, shrouded Neutral bar, earth termination complete all as specified and directed by Engr-in-Charge. Make Indo Asian Cat NoKSLTVM04 and MCCB Cat Part No N3200M3P) or equivelant in Havells/Standard/ Legrand. (Out going MCBs shall be measured and paid seperately under relevant item)
MCB TPN 63 Amps "D" Curve complete all as specified and directed. Make : Havells DHMGDFPF063 or equivalent in Legrand/ Indoasian/ HPL.
MCB SPN 10-32 Amps "C" Curve complete all as specified and directed. Havells DHMGCSNF006032 or equivalent in Legrand/ Indoasian/ HPL.
MCB SP 40 Amps"C" Curve complete all as specified and directed.Havells DHMGCSPF040 or equivalent in Legrand/ Indoasian/ HPL.
MCB SP 6-32 Amps "C" Curve complete all as specified and directed. Havells DHMGCSPF006032 or equivalent in Legrand/ Indoasian/ HPL.
Submain wiring with 6 sq mm four single core(for phases and neutral) using multistranded copper conductor PVC (F.R) insulated unsheathed with and incl 6 sq mm insulated unsheathed PVC insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit ISI marked with accessories. (Note: 05 runs of 06 sqmm and one run of PVC concealed conduit shall be measured as one run only
Submain wiring with 4 sq mm two single core(for phases and neutral) using multistranded copper conductor PVC (F.R) insulated unsheathed with and incl 4 sq mm insulated unsheathed PVC insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit ISI marked with accessories ( for Geyser & AC) (Note: 03 runs of 4 sqmm and one run of PVC concealed conduit shall be measured as one run only
Submain wiring with 2.5 sq mm two single core(for phases and neutral) using multistranded copper conductor PVC (F.R) insulated unsheathed with and incl 2.5 sq mm insulated unsheathed PVC insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit ISI marked with accessories (For SPN 4 way DB) (Note: 03 runs of 2.5 sqmm and one run of PVC concealed conduit shall be measured as one run only
AC 3 Phase Electronic KWH Energy meter of rating 10-60A class 1-00x415V, 50Hz with MS powder coated enclosure, display - Make -HPL or equivalent other manufactuarer as per list of makes. Make : L & T Cat No WM301BC7D10 or equivalent in Schneider/ HPL/ Havells.
S & F AC Single phase electronic KWH energy meter with MS powder coated enclosure 0-20 Amps, 230 V, 50 Hz complete all as specified and directed. Make : L & T Cat No WM101BC5D10 or eq in Shneider/ Havells/ HPL.
S & F TV Socket 1 Module complete all as specified and directed
S & F RJ 11 Telephone socket 01 module complete all as specified and directed
S & F PVC insulated telephone cable 0.5 Sqmm 01 pair complete all as specified and directed
INTERNAL WATER SUPPLY :- Gun metal gate valve with iron wheel head screwed both ends 75 mm dia
Angular stop cock, chromium plated, cast copper alloy, screwed down, screwed for iron pipe 15 mm dia bore. Make Jaquar Code No CON-059KNor equivalent.
Health Faucet with 1 Mtr flexible tube in chrome finish16 mm dia (outer), low density ploythene, suitable for cold water application complete with union and teflone washers and holder to suit 15 mm angle cocks (Make : Jaguar cat part No ALD-IVY-585 or equivalent).,
S & F SS wall mixer with provision for overhead shower with 115mm long body bend pipe on upper side connecting lugs & wall flanges suitable for 16mm CPVC pipe conform to cat part no CQT 23273 UPR of Jaquar.
ROAD/PATH/HARDSTANDING :- Machine pressed precast concrete interlocking paver block any shape and size copnfirming to IS15658-2006OF 60 mm thickness M-35 grade with grey cement and pigment complete all as specified and directed.
COMPREHENSIVE MAINTENANCE OF LIFT:- Comprehensive maintenance of electrically operated gearless goods lift through OEM for 544Kg and 884 Kg capacity,to serve ground plus eight upper floors all as mentioned in relevant items of this BOQ complete all as specified and as directed for First year after expiry of defects liability period.
All as per item no. 112 here in before but for Second year after expiry of defects liability period.
All as per item no 112 here in before but for Third year after expiry of defects liability period.
M&L for earthing with 600x600x3.15mm copper earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including copper strip of size 20x3 mm by means of copper bolts,nuts and check nuts and washers (and 40mm dia GI light grade pipe for protection of copper strip) to the extent of 7.5 metres as earthing lead and connecting to the eqpt, viz transformer, L.T. kiosk, lightning protection down strip, lift machine room etc. incl charcoal dust and salt packed all around the earth plate in the earth pit all as per electrical plate No. 3 of SSR Part I including PCC 1:3:6 type C1,40mm thick precast RCC M-25(design mix) cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both ways and handle and 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, M& L complete including excavation and earth work in any type of soil strata and testing complete all as specified and directed.
S&F of copper strip 20x3mm with saddle and fixing screws etc complete all as specified and directed.
Mecone Construction Contractors
VIJAY CONSTRUCTIONS
CREATIVE BUILDERS
KCP Engineers Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid