Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | ₹8.7 L | L1 | Accepted-AOC AOC_Issued |
| 2 | L2₹8.9 LRejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKATA 700158 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700158 | ₹8.9 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹9.3 LRejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | ₹9.3 L | L3 | Rejected-Finance that the bid is not L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Absence of MOU with EI Contractor |
| 5 | Rejected-Technical CHATTAPADMAPUR RAMNAGAR DIST PURBA MEDINIPUR | PURBA MEDINIPUR | - | - | Rejected-Technical Due to absence of proper credentia |
| Sl No | Description | Qty | Unit | ANIKET COOLING AND REFRIGERATION CO L2 | B. ENGINEERING CO. L3 | P. M. COOLING AND ENGINEERING CO L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivary 2.0 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1No. Rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. R32/R410A ( Make: Hitachi/Voltas/Bluestar/O-General/Daikin) | 3 | Nos. | 75,000 ₹2.3 L | 79,500 ₹2.4 L | 66,500 ₹2.0 L |
| 2.00 | SITC of 1.5 TR capacity concealed type Split Air Conditioner having rated cooling capacity of 18000 BTU/hr. with rotary compressor, 1 no IDU Cooling Capacity (5.2KW to 3KW)of rated power supply 230V-1ph-50 Hz,1 no ODU of rated power supply-230V-1ph-50 Hz . AC supply. (Make- O-General/ Mithubushi Electric / Mithubushi Heavy / Hitachi / Daikin) | 6 | Nos. | 54,000 ₹3.2 L | 67,500 ₹4.0 L | 57,800 ₹3.5 L |
| 3.00 | Installation, testing & Commissioning Charges for following Air Conditioner. The indoor unit must be supported by structure made of 40 x 40 x mm angle and 40 x5 flat and tie rod incl. necy. Painting for
1.5 Tr | 6 | Nos. | 2,900 ₹17,400 | 3,000 ₹18,000 | 3,500 ₹21,000 |
| 3.10 | 2.0 Tr | 3 | Nos. | 6,500 ₹19,500 | 3,000 ₹9,000 | 3,500 ₹10,500 |
| 4.00 | Supply, Installation and commissioning of hard / soft copper refrigerant piping, complete with fittings, elbows, bends, globe valve of suction & liquid line with bracket & supporting arrangement on walls.
1/4" OD 6.35 mm dia Liquid/Suction line with 9mm thick nitrile insulation. | 80 | Mtr. | 240 ₹19,200 | 70 ₹5,600 | 240 ₹19,200 |
| 4.10 | 5/8" OD 22.2 mm dia Liquid/Suction Line with 9mm thick nitrile insulation. | 80 | Mtr. | 400 ₹32,000 | 120 ₹9,600 | 425 ₹34,000 |
| 5.00 | Power & Control Cable: Supply & laying of power cable from control panel to condensing unit.
4 core 2.5 sqmm communition cable.(IDU to ODU ) Make: KEI/Polycab/Havells | 120 | Mtr. | 190 ₹22,800 | 120 ₹14,400 | 180 ₹21,600 |
| 6.00 | S& F of a 32 mm dia uPVC drain pipe ((Make. Oriplast /Supreme) needs to be attached for extending drain pipe line from the indoor unit of the Ductable/split machine/attached tray in case of window machines to direct the flow of condensate water to the existing nearest rain water pipe or sewerage pipe connected to the building including S& F of PVC Elbow(32 mm dia ), PVC Tee (25 mm dia), PVC Socket (32 mm dia), 3/4 inch dia PVC drain pipe, PVC China clip, adhesives( PVC M-Seal) as per the requirement.[NS] | 30 | RM | 170 ₹5,100 | 100 ₹3,000 | 120 ₹3,600 |
| 7.00 | S& F of a 25 mm dia uPVC drain pipe ((Make. Oriplast /Supreme) needs to be attached for extending drain pipe line from the indoor unit of the Ductable/split machine/attached tray in case of window machines to direct the flow of condensate water to the existing nearest rain water pipe or sewerage pipe connected to the building including S& F of PVC Elbow(25 mm dia ), PVC Tee (25 mm dia), PVC Socket (25 mm dia), 3/4 inch dia PVC drain pipe, PVC China clip, adhesives( PVC M-Seal) as per the requirement.[NS] | 25 | RM | 170 ₹4,250 | 90 ₹2,250 | 110 ₹2,750 |
| 8.00 | Fabrication work :-Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of 2 Nos. of outdoor unit of 8.5 TR Ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. Area of the platform is 4Mtr. x 1.5Mtr. Including the scaffolding charge upto 4th floor.[NS] | 8 | Nos. | 16,700 ₹1.3 L | 12,500 ₹1 L | 4,500 ₹36,000 |
Tender Value
₹9.3 L
EMD Value
₹18,600
Closing Date
4 Oct 2024, 1:00 pmClosed
EE,KNHED, PW Dte
Kolkata North Health Electrical Division, PWDte. KIT Annex Building (4th Fl.), KOLKATA 700 073
Arrangement of AC Machines at NICU, Annex B Doctors Room, Faculty Room between Annex A B ward,NS office on urgent Basis RATHRI SATHI at Dr BC Roy PGIPS -
2024_WBPWD_746381_1
WBPWD/EE/KNHED/e-NIQ-48/24-25
Open Tender
A/C ORG
30 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹18,600
Office of The EE, KNHED, PW Dte
17 Apr 2026
6 Sept 2024
7 Oct 2024
6 Sept 2024
4 Oct 2024
13 Sept 2024
12 Sept 2024
Amount
Supply & delivary 2.0 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1No. Rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. R32/R410A ( Make: Hitachi/Voltas/Bluestar/O-General/Daikin)
SITC of 1.5 TR capacity concealed type Split Air Conditioner having rated cooling capacity of 18000 BTU/hr. with rotary compressor, 1 no IDU Cooling Capacity (5.2KW to 3KW)of rated power supply 230V-1ph-50 Hz,1 no ODU of rated power supply-230V-1ph-50 Hz . AC supply. (Make- O-General/ Mithubushi Electric / Mithubushi Heavy / Hitachi / Daikin)
Installation, testing & Commissioning Charges for following Air Conditioner. The indoor unit must be supported by structure made of 40 x 40 x mm angle and 40 x5 flat and tie rod incl. necy. Painting for 1.5 Tr
Supply, Installation and commissioning of hard / soft copper refrigerant piping, complete with fittings, elbows, bends, globe valve of suction & liquid line with bracket & supporting arrangement on walls. 1/4" OD 6.35 mm dia Liquid/Suction line with 9mm thick nitrile insulation.
5/8" OD 22.2 mm dia Liquid/Suction Line with 9mm thick nitrile insulation.
Power & Control Cable: Supply & laying of power cable from control panel to condensing unit. 4 core 2.5 sqmm communition cable.(IDU to ODU ) Make: KEI/Polycab/Havells
S& F of a 32 mm dia uPVC drain pipe ((Make. Oriplast /Supreme) needs to be attached for extending drain pipe line from the indoor unit of the Ductable/split machine/attached tray in case of window machines to direct the flow of condensate water to the existing nearest rain water pipe or sewerage pipe connected to the building including S& F of PVC Elbow(32 mm dia ), PVC Tee (25 mm dia), PVC Socket (32 mm dia), 3/4 inch dia PVC drain pipe, PVC China clip, adhesives( PVC M-Seal) as per the requirement.[NS]
S& F of a 25 mm dia uPVC drain pipe ((Make. Oriplast /Supreme) needs to be attached for extending drain pipe line from the indoor unit of the Ductable/split machine/attached tray in case of window machines to direct the flow of condensate water to the existing nearest rain water pipe or sewerage pipe connected to the building including S& F of PVC Elbow(25 mm dia ), PVC Tee (25 mm dia), PVC Socket (25 mm dia), 3/4 inch dia PVC drain pipe, PVC China clip, adhesives( PVC M-Seal) as per the requirement.[NS]
Fabrication work :-Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of 2 Nos. of outdoor unit of 8.5 TR Ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. Area of the platform is 4Mtr. x 1.5Mtr. Including the scaffolding charge upto 4th floor.[NS]
Part B : EI Work Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Havells/ Polycab/ Finolex/ Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (PWD EL. SCH. Page No- E-14 Item No- E, 1, a, iii i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. (PWD EL. SCH. Page No- F-5 Item No- 9, i & ii) i) 4 Sqmm
ii) 2.5 Sqmm
Supply and fixing of 1Ph Timer for controlling 2 Nos. 3-Ph AC machine (HAT) of size 5.0Tr costing of the following materials: a) 24inch x 18inch x 6 inch single door MS box 2mm thick powder coated- 1 Nos b) Digital Timer (make: Seimens/L&T/GIC) - 1 No c) Single Pole MCB (210-220V/ 32A) (make: L&T/Seimens)- 1 Nos d) Double Pole Power Contractor required rating (make: L&T/ SEIMENS/ ABB)- 1 No f) ON (Green and RED) (2 Nos) Indicating Lamp LED- 2 Nos g) Toggle Switch for Bypass Time Switch for each machines- 1 No.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (PWD EL. SCH. Page No- E-19 Item No- 17)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (PWD EL. SCH. Page No- E-17 Item No- 5,a)
(Rate should be quotated including all taxes and duties and GST)
ANIKET COOLING AND REFRIGERATION CO (BID ID -5624816)
B. ENGINEERING CO. (BID ID -5669581)
stage.html
html • 0.05 MB
technical_1649529.pdf
techsummary_1649529.pdf
finance_1649529.pdf
BOQ Comparative Chart
xlsx
finsummary_1649529.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
suspension.pdf
Additional Documents • 2.91 MB
2911.pdf
Tender Documents • 1.46 MB
BOQ_1649529.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid