GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
ADDITION/ALTERATION AND PROVN OF BASIC AMENTIES TO CERTAIN SMQs/OMQs, AC FOR BRIEFING HALL, DEFICIENT ELECTRIC METERS AT VARIOUS LOCATIONS AND DG SET AT AIR FORCE STATION PATHANKOT
2021_MES_495986_1
8420/GE/PAF-61/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹98,000
Yes
4 Apr 2022
18 Dec 2021
17 Jan 2022
18 Dec 2021
15 Jan 2022
1 Jan 2022
Amount
Supply and fixing energy efficient water heater storage type, electric supplied and installed complete incl all PVC connection for hot and cold water & CP connections and having tank of capacity 25 litres, incl suitable size of iron anchor bolt for fixing the new geyser complete all as specified and directed by Engineer-in-charge.
Supply and fixing bib taps 15mm fency type with crutch or butterfly handle, screwed down screwed for GI pipe complete all as specified and directed by Engineer-in-charge.
Supply and fixing stop valve 15mm fency type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for GI pipe complete all as specified and directed by Engineer-in-charge.
Supply and fixing GI tubing pipes galvanized, "Medium class", supplied and laid complete including fittings 15 mm (1/2") dia complete all as specified and directed by Engineer-in-charge.
Cutting of Existing water supply main any size upto 25 /20 mm for Taking branch connection for taking branch connection of size 15 mm including insertion of Tee unegual all as required at site or directed by Engr-in-Charge.
Supply and fixing Switch piano flush button single pole one way 15 amp 230 Volts complete all as specified and directed by Engineer-in-charge.
Material and labour for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 voltsc complete all as specified and directed by Engineer-in-charge.
Material and labour for MCB single pole 240 volts 16 amps, with rupturing capacity 10 KA, complete all as specified and directed by Engineer-in-charge.
Material and labour for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 2.5 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit 2mm thickness ISI marked cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit 2mm thickness with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed by Engineer-in-charge.
Material and labour for ceiling rose surface bakelite 2 to 3 terminals complete all as specified and directed by Engineer-in-charge.
Material and labour for switch piano flush button single pole one way 5 amps 240 volts complete all as specified and directed by Engineer-in-charge.
Supply and fixing exhaust fan 300 mm sweep steel body single phase 230 volts 50 Hz AC,totally enclosed mounted on two ball bearings complete with louvers & shutters including making of suitable size of hole for fixing of ex fan, cutting chases to wall making good the disturbed surfaces to match with the existing specification, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed by Engr- in Charge
Supply, installation,testing of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 as per IS: 13364 complete comprising of AIR cooled Diesel Engine (CPCB NORMS COMPLIANCE) developing 10 BHP @1500 RPM & 7.5 KVA KOEL Green make Alternator rated at 3 Phase ,415 Volts,50 Hz 0.8 p.f @ 1500 RPM both mounted ,and aligned on a common MS base frame complete with MS fuel tank Integrated controll panel,Residential Exhaust silencer,AVM Pads fitted on base frame ,1 No. 12 Volts DC battery Leads,1st fill of lube oil .and other features including foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity complete all as specified and directed by Engineer-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in soft/loose of soil for laying of pipes etc complete all as specified and directed by Engineer-in-charge.
Returning, filling in(soil) including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Sub Class 'B' bricks laid dry flat to cover the cable with width equal to the length of cable and abutting each other for protection of cable complete all as specified and directed by Engineer-in-charge.
Sand cushioning to underground cables providing a layer of 8cm thick before laying the cable and 15cm thick after laying,stretching and testing the cable complete all as specified and directed by Engineer-in-charge.
Supply, installation, commissioning and testing CPRI approved LT panel of suitable size recommended by manufacturer cubical floor mounted type (IP-55 degree of protection ) made out of 3.15 mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 100 amps rating made of copper strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland incl 50x50x6 mm frame (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including the following (i) On load Change over switch 4 pole , 63 Amp 415 Volt front operated (ii) MCCB 4 pole 415 volts with thermal magnetic release rupturing cap 25 KA, 63 amps - 01 Nos for incoming ) (iii) MCB ,SPN 40 amps -3 Nos ( for outgoing) (iv) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio (v) RYB LED indicating lamp- 01 No
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 191 Part-I all as specified and directed . (i) Main earthing lstrip from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
Supply and install in wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of capacity 1.5 Ton complete all as specified and directed by Engineer-in-charge.
Submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 6.0 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in & including concealed rigid metallic steel conduit 2mm thick ISI Marked cutting chases to wall for laying conduit and making good the distrubed wall surfaces to matdch with existing specificaiton complete all as specified and directed by Engineer-in-charge.
Supply and fixing electronic meters temper proof LCD display with polycarbonate cover 230V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed by Engineer-in-charge.
Supply and fixing meter box suitable for fixing of one meters with locking arrengement of suitable size including complete all as specified and directed by Engineer-in-charge.
M/S SHRI RAM BUILDERS
M/S V K TRADERS
Vijay Kumar Contractor and Engineers
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .