Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAccepted-AOC 701 HEADQUARTERS SANT DNYANESHWAR MARG CHETANA COLLEGE ADJUNCT BANDRA EAST MUMBAI 400051 | MUMBAI SUBURBAN | MAHARASHTRA | 400051 | ₹9.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹9.3 Cr+₹21.4 L (2.35%)Rejected-Finance NOT SPECIFIED | ₹9.3 Cr+₹21.4 L (2.35%) | L2 | Rejected-Finance Not being the lowest |
| 3 | L3₹9.4 Cr+₹29.2 L (3.22%)Rejected-Finance 3 KHATAU APARTMENT TILAK ROAD JOSHI LANE GHATKOPAR EAST MUMBAI 400 077 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | ₹9.4 Cr+₹29.2 L (3.22%) | L3 | Rejected-Finance Not being the lowest |
| 4 | L4₹10.0 Cr+₹95.0 L (10.5%)Rejected-Finance | ₹10.0 Cr+₹95.0 L (10.5%) | L4 | Rejected-Finance Not being the lowest |
| 5 | L5₹11.4 Cr+₹2.3 Cr (25.3%)Rejected-Finance | ₹11.4 Cr+₹2.3 Cr (25.3%) | L5 | Rejected-Finance Not being the lowest |
Tender Value
Refer Docs
EMD Value
₹8.2 L
Closing Date
8 Jan 2021, 6:00 pmClosed
Chief Engineer (Navy) Mumbai
HQ Chief Engineer Navy Mumbai, 26 Assaye Buildings, SBS Road, Colaba, Mumbai-05
PROVISION OF BULK STORE HOUSE AT NSD MANKHURD
2020_MES_381954_2
87861/E8
Open Tender
Civil Works
Lump-sum
540 days
Mankhurd
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (NW) Mankhurd
₹8.2 L
Yes
24 Feb 2021
15 Dec 2020
11 Jan 2021
15 Dec 2020
8 Jan 2021
22 Dec 2020
15 Dec 2020 - 19 Dec 2020
Amount
Schedule-A' Part-I 'Buildings & Structures' Total of Schedule-'A' Part-I B/F from serial page No. 24
Schedule-A' Part-II 'Excavation, Earthwork, Site Clearance and Land Development' Total of Schedule-'A' Part-II/F from serial page No. 25
Schedule-A' Part-III 'Internal Water Supply' Total of Schedule-'A' Part-III B/F from serial page No. 26
Schedule-A' Part-IV 'Internal Electrification' Total of Schedule-'A' Part-IV B/F from serial page No. 30
Schedule-A' Part-V 'Lifts' Total of Schedule-'A' Part-V B/F from serial page No. 31
Schedule-A' Part-VI 'Water Cooler' Total of Schedule-'A' Part-VI B/F from serial page No. 32
Schedule-A' Part-VII 'Fire Fighting System' Total of Schedule-'A' Part-VII B/F from serial page No. 37
Schedule-A' Part-VIII 'Lightning Protection' Total of Schedule-'A' Part-VIII B/F from serial page No. 39
Schedule-A' Part-IX 'Roads / Paths / Hard Standing' Total of Schedule-'A' Part-IX B/F from serial page No. 40
Schedule-A' Part-X 'Sewage Disposal' Total of Schedule-'A' Part-X B/F from serial page No. 42
Schedule-A' Part-XI 'Area Drainage' Total of Schedule-'A' Part-XI B/F from serial page No. 44
Schedule-A' Part-XII 'External Water Supply' Total of Schedule-'A' Part-XII B/F from serial page No. 46
Schedule-A' Part-XIII 'External Electrification' Total of Schedule-'A' Part-XIII B/F from serial page No. 48
Schedule-A' Part-XIV 'Compound Wall/Gate' Total of Schedule-'A' Part-XIV B/F from serial page No. 50
TO BE QUOTED ITEMS IN PROVISIONAL SCHEDULES
Schedule-`A' Part-III, Internal Water Supply
S&F two way Bib cock of Prayag make Cat no SQT-512 ANKN or equivalent of Marko,Parko as approved by GE complete all as specified and directed.
M&L health faucet of 15mm dia with 1m tube hook,Cat no 187 of Prayag or equivalent as approved by GE complete all as specified and directed.
Schedule-`A' Part-IV, Internal Electrification
Supply and fix 1X18/20 watt LED tube light fitting (including LED), 230 Volt indoor decorative channel housing Surface/wall mounting, with inbuilt electronic control gear , bipin holders, connector block etc complete with all accessories internally pre wired and including connecting lead, three core 1.5 Sqmm, FRLS flexible copper multistranded conductor cable from ceiling rose to tube light fitting complete all as specified and directed. Make: Bajaj cat ref No. BCLSB 18 WH or equivalent in Philips, CG & Wipro.
Supply and fix 1X38/40 watt LED tube light fitting (including LED), 230 Volt indoor decorative, pendant type including hanging chain/conduit with inbuilt electronic control gear , bipin holders, connector block etc complete with all accessories internally pre wired and including connecting lead, three core 1.5 Sqmm, FRLS flexible copper multistranded conductor cable from ceiling rose to tube light fitting complete all as specified and directed. Make: Philips cat ref No. SP680P LED39S 6500 or equivalent in CG & Wipro.
Supply and fix LED Street Light fitting, 25 watt , 230 Volt including LEDs complete made of cast aluminium housing toughened glass, IP 65 and wired with all accessories connecting with three core twisted flexible copper conductor cable of 1.5 sqmm size, fixing bracket made by 40mm dia GI pipe medium grade 1.0 mtr long bend to shape and fixed on wall with the help of flat iron clamps 25x3 mm including nuts, bolts, washers made of GI/Steel complete all as specified and directed. Make: Philips cat ref No.SP680 or equivalent in Philips, CG & Wipro.
Supply and fixing energy efficient BEE five star rated ceiling fan, 1200mm sweep and connecting up including provision of three core flexible copper wire of size 1.5 sqmm from ceiling rose to ceiling fan complete in all respect all as specified and directed. Make Crompton Part No HS Plus- 5 star or equivalent in Orient/ Bajaj/Havells.
Supply & fix Heavy Duty metallic Exhaust fan of sweep 300 mm sweep with frames, blades, mounting anchor fasteners, aluminium louvers made of aluminium sheet of 0.5 mm thickness, provision of three core 1.5 Sqmm copper cable from ceiling rose to fan, making opening of required in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4, including scafolding if any required to carry out the work in building of height up to 20 Meters complete in all respects the Exhaust Fan Shall Conform to Cat no EXHD300-4-1 of Crompton or Equivalent from Bajaj/GE
Supply & fix Heavy Duty metallic Exhaust fan of sweep 380 mm sweep with frames, blades, mounting anchor fasteners, aluminium louvers made of aluminium sheet of 0.5 mm thickness, provision of three core 1.5 Sqmm copper cable from ceiling rose to fan, making opening of required in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4, including scafolding if any required to carry out the work in building of height up to 20 Meters complete in all respects the Exhaust Fan Shall Conform to Cat no EXHD380-4-1 of Crompton or Equivalent from Bajaj/GE
S&FMCB DB, SPN, double door, 4 way IP 43 metal body having earth terminal complete in all respect concealed in wall including making electrical incoming and out going connections with ligs/thimbles complete all as specified and directed.
S&FMCB DB, TPN, double door, 6 way IP 43 metal body having earth terminal, neutral bus terminal for 6 way circuits complete in all respect concealed in wall including making electrical incoming and out going connections with ligs/thimbles complete all as specified and directed.
S & F MCB, SP, 06 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F MCB, SPN, 06 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron strip 32 X 6 mm dia by means of bolts, washers, watering pipe 20mm dia, medium grade GI pipe, with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from earthing plate electrode to test point including concrete pit in PCC (1:3:6) type C-I and pre-caste RCC 1:2:4 type B-1 cover with 8mm dia MS handle. Charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as show in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
Note: (1). 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately (2). Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (4) The Execavation shall be done manually by man power, the quoted rate is inclusive of digging out roots. (5) The qoted rate is deemed to be inclusive of removal of the excess material from the work site.
S&F 36 watt ceiling square shape having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W,with surge voltage protection and other safety test as per IS: 15885(Part-2/Sec-13):2012, having input voltage 220-240 V,input frequency 50-60 Hz, PF>0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed . Cat/model no. PCGLLL 36 57 of Polycab or equvalent in Philips, CG & Wipro.
Schedule-`A' Part-V, LIFT
that detail drg is tobe approved within one month of submission by contractor (a) Type of Lifts: Goods (b) Load capacity: 3000 Kgs (c) Speed: 0.5 mtr/sec with single speed motor (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Type of Drive: AC variable voltage & variable frequency drive . (f) Type of Machine: Geared type (g) Car size (Inside): as per standard (h) Car and landing door at all floors : Automatic centre opening with VVVF door drive and sliding type fabricated by stainless steel sheet not less than 16 gauge having hair line finish (N-304) (j) Car enclosure: manufactured with stainless steel frame not less than 16 gauge with Hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with CFL/LED light fitting complete internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill/wire mesh for protection (k) Terminal buffers: Metal special spring buffers as per manufacturer specifications. The buffing stroke should not be less than 200mm.
(l) Door opening (Inside): protected by centre opening stainless steel doors with hairline finish doors with clear opening of the door shall be 1400mm. (m) Car & counter weight Guide: Guide rails of `T' Section Mild steel as per OEM design counter weight shall be cast iron as recommended by OEM (n) Flooring: Aluminum chequred plate 5mm thick complete (o) Signals :- (i) Combined luminous hall buttons with LCD/VFD Dot Matrix hall position indicators at all floors. (ii) LCD/VFD Dot Matrix disply for car position indicator of stainless steel (iii) One No car operating panel with Luminous buttons in car (stainless steel). (iv) Car direction indicator in car & Landing. (v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (This system should be separate from ARD batteries). (vi) Overload warning feature in car cabin. (Display and announcing type both)
(viii) All signal fixture & car operating panel on hair line stainless steel face plate with hair line finish. (ix) Full Height Infra red door sensor safety edge of door for entire height. (x) Built in announcing system without hand set 02 Nos, One for lift car & ground floor landing door and one announcing system with hand set in machine room. (xi) The interior of the car should be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/exit door is open or closed. (p) Stops & Opening : All opening on same side. (q) Safety devices: (i) Automaic Rescue Devices (ARD) to be operating with maintenance free batteries having suitable capacity. The Batteries must be rechargeable & have auto recharging facilities. (ii) The ARD actuation time should be less than 30 second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open. (iii) Make: ADICON/YASKAWA/SIEMENS/L&T/OTIS/GE /HYUNDAI/TOSHIBA/FUJI/OEMs own make. (r) Operation: Simplex, full collective automatic operation with and without attendant. (s) Machine room: Located above the hoist way Details as per building drawing.
(t) Hoist way Constn; Details as per building drawing (u) Civil work : Necessary Civil work such as making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc. (v) AC drive of make OTIS/ Yukawa / Mitsubishi / Fuji/ Schindler/L&T/ Siemens/GE/OEMs own make. (w) Control system shall be enclosed loop type. (x) Door shall have AC-VVVF controlled close loop operated. (y) Face plate shape shall be rectangular and stainless steel with hairline finish. (z) Counter weight shall be of cast iron as recommended by OEM. (aa) One number wall mounted type telephone instrument of make Crompton Greaves/Beetel installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room.
(ab) One number electrically operated siren, operating voltage 240 volts having audible range of 0.5 Km of make KHERAJ model No. SS050 alongwith one number inverter unit of suitable capacity but not less than 0.5 KVA of make Luminous/Microteck comprising of maintenance free battery of make Exide connected with charging system (may be through regenerative drive) including a separate switch/push button inside of car panel and electric wiring circuit up to the machine room. The siren shall be installed over the building at appropriate place and to be operated from inside the car. (ac) One number wall mounted type telephone instrument of make Crompton Graves/ Beetel installed inside of car cabin alongwith fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room.
M & L for earthing complete with Copper plate of size 60cm x 60cm x 3mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to Copper strip of size 20x3mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed.
Schedule-`A' Part-VII, Fire Fighting System
Material & Labour for cutting of existing MS pipe of size 150mm dia including provision of Tee 150mmx150mmx150mm with all necessary welding work, complete all as specified and directed
Material and labour for construction of brick masonary valve pit chamber of size 0.8 x 0.8 x 0.8 metre (internal) with brick masonry 230 mm thick in CM 1:6, PCC 1:4:8 type D2 foundation 100 mm thick, over 15cm thick hardcore, finished fair and even, PCC 1:2:4, type B1 coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar 1:4 plaster on exposed surfaces of brick wall (both internal and external), mild steel cover of 3.0 mm thick including mild steel angle iron 50x50x6 mm size frame fixed to PCC coping with the same size of angle iron hold fast and with necessary handle and locking arrangements, metal surfaces duly painted with black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surfaces with 3 coats of white wash including necessary excavation in any type of soil and disposal of surplus soil outside MD land complete all as specified and directed.
M&L control panel for terrace pump of cubical double door type fabricated out of 2mm thick CRCA sheet with hinged lock ,complete including control and power wiring including MCB 4 Pole 40 Amps and DOL starter of suitable capacityfor terrace pump and indicating lamps fixed in wall complete all as specified and as directed
Supply and fixing brass Air release valve of size 25mm dia including all necessary fittings required for fixing complete all as specified and directed.
Schedule-`A' Part-XV, Solar Panel
Supply, install, testing, design and commissioning of Solar PV modules to meet cumulative rated capacity of 60 KWp at STOC. Modules will be of Poly Crystalline type with 72 cells and minimum rating of 315 Wp with positive tolerance, with minimum 1100 mm cable length. Module efficiency >15.8%, fill factor>0.7, performance ratio more than or equivalent to 75%,module will be free of PID, module connector suitable for MC4/Bizlink and junction box with minimum IP 67 rating. Module NOCT will be 45±°C with temperature coefficient of power <0.4%/°C, and will be suitable for operation from -20°C to +60°C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc., Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68).
Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. Guaranteed electrical degradation of power generated not exceeding 20% of the minimum rated power over the 25 year period and not more than 10% after ten years period of the full rated original output. Warranty against manufacturing defect, raw material, workmanship, inspection and testing procedures shall be 5 years from the date of commissioning. Modules shall be certified as per IEC 61215-Edition -II, IEC 61646 and IEC 61730-1 & 2 and other applicable IEC/IS standards. It shall perform satisfactorily in relative humidity 85 ± 5%l) and should withstand wind 170 KPH on the surface of the panel.
Module Mounting Structure: Supply ,fabricate and erection of mould mounting type structure hot dip galvanised mild steel with coating not less than 85 Microns and suitable to wind load 170 KMPH and electrolytically compatible channels, bracing purlins Size as per IS code Design, electromagnet washers nut , bolt including cutting drilling etc. The design should be as per relevant latest IS-2061 and galvanizing as per IS-4759. It should be suitable for the wind speed, sun light and climate condition of the plant location. The design life should be more than 25 years and minimum yield strength of 340 MPA. Module Ground Clearance shall be 500mm ± 100mm. Properties of RHS will conform to IS 4923:1997. HDG Fasteners of 4.6 grade and 8.8 grade for Structure. The Module Mounting Structure to be of Manual Seasonal tilt of 0 degree to 45 degree to provide maximum generation. The structure should be suitable for easy removing and refixing of PV modules of the solar plant all as specified and as directed by Engr-in-Charge. NOTE:- foundation shall be paid separately as per relevant item .
Design, Supply, installation, testing and commissioning of grid tied 3 phase string inverter outdoor type of with minimum IP 65 rating, with minimum 30 kW AC output at 50°C ambient temperature. Minimum European efficiency of the inverter shall be 98% load as per IEC 61683 standard for measuring efficiency. Maximum DC input voltage shall be 1000 V and inverter supplied shall have up to 10% additional DC input capacity. (Array to Inverter Ratio 1:1), 3 phase AC Nominal Output voltage 415 V (with ±10% range ), Frequency 50Hz (±10% range), PF at rated output capacity: 1 (with range from 0.8 lag to 0.8 lead), Total ITHD: < 3%, Operating temperature range : - 20°C to + 60°C. All inverters should consist of associated control, protection and data logging devices and remote monitoring hardware and compatible with software used for string level monitoring. All as specified and as directed . Other important features/ protection required in the inverter are as under:-
(i) Automatic morning wake-up and nightly shutdown. (ii) Mains (Grid ) over-under voltage and frequency protection. (iii) Galvanic isolation and fool proof protection against ISLANDING . (iv) Included authentic tracking of the solar arrays maximum power operation voltage (MPPT). (v) Array ground fault detection. (vi) LCD and Piezoelectric keypad operator interface Menu driven. (vii) Automatic fault conditions reset for all parameter like voltage, frequency and /or black out. (viii) MOV type surge arrester on AC and DC terminals for over voltage protection from lightning -induced surges. (ix) Provision for input and output isolation. (x) Inverter shall be installed on GI stand made by the angle size 50mm x 50mm x 6mm. Structure buried in ground and shall be 450mm above ground level. Grid Connectivity: Relevant CERC/RERC regulations and grid code as amended and revised from time to time shall be complied. Inverter shall adjust the voltage & frequency levels to suit the Grid. Complete all as specified and directed.
Supply and installation of branch, MC4 Male/Female connectors set compatible with module connectors with min of IP66 rating and design with suitable lugs for 4 Sqmm Cable complete all as specified and directed.
Design, Supply, install, laying with PVC conduits, lugs, nails, cable ties, termination etc., testing and commissioning of annealed single copper DC String cable of 1C x 4 Sqmm Solar grade, UV resistant 1.5 kV rated DC Cables with electron beam XLPO insulation confirming to IEC IEC 60754-1 & IEC 60754-2, IEC 60332-1, IEC 60332-3-24., IEC 61034. Temperature range -40 to +1200 C complete all as specified and directed. Average energy loss in DC cabling shall be <1.5% from solar panel to inverter. complete all as specified and directed.
Design, Supply, install, laying with conduits, lugs, nails, cable ties, termination etc., testing and commissioning of PVC insulated copper cable of 1C x 4 Sqmm for module to module earthing confirming to IEC and IS standards. complete all as specified and directed. 1.1 KV rated AC cable
Design, Supply, install, laying with, lugs, nails, cable ties, termination etc., testing and commissioning of AC copper cable of 5C x 10 Sqmm from inverters to AC panels as per inverter and panel design, UV resistant 1.1 kV rated, PVC/XLPE insulation confirming to IEC and IS standards. Temperature range -40 to +1200 C.complete all as specified and directed.
Design, Supply, laying in wall/tray with necessary lugs, cable termination kits, testing and installation of power cable from AC panel to main LT panel of XLPE insulated 3.5C x 70 sq mm, 1.1kV Aluminium Armoured LT cable as per relevant IS complete all as specified and directed.
Supply, installation, testing and commissioning of weather and vermin proof outdoor type LT Panel factory made, front openable, Single door type,IP-54 CPRI approved fabricated out of 3 mm thick CRCA (Cold Rolled Closed Annealed Cell) sheet compartmentalized design not less than 1.8m x 1.6m x 0.75m including mild steel channel frame of ISMC 75 at the base of panel only for grouting purpose, and grouted in M-20grade concrete(Design Mix) using 20 mm graded stone aggregate, duly epoxy powder coated, complete with heat shrink insulated aluminium bus bar of 200 Amps rating 4 Nos, including all connections with aluminium strips. Pillar box shall be provided with danger notice plate with skull & bone sign, PVC gasketed and sealed, making all incoming and out going electrical cable connections with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm with 50 CM height from ground level at the base of panel complete all as specified and as directed (Qty-1 Nos). Each panel
Supply, laying and testing of 25 mm X 3 mm flat aluminium earthing strip as per applicable standards.
Supply and fix DC DB,/ combiner box to disconnect DC supply before Inverter with and including 1000V DC SPD, 800V 16A DC MCB, 1000 V 20 DC Isolator and connectors in Combiner Box suitable for solar inverter output up to 30 KW , complete all as specified and directed,
Civil Blocks of 250 x 250 x 250 mm for module mounting structure
Schedule-`A' Part-XII, External Water Supply
S&F Sluice valve 80mm bore, cast iron body, flanged and drilled end confirming to IS-14846,ISI marked ,class PN 1.0 including all joints with rubber joint with rubber or fibre board gaskets, bolt and nut,washers,iron wheel all as specified and as directed.
M&L for Cutting of existing CI pipe 80mm in position for inserting CI Tee of size (80x80x80)mm and (80x80x50)mm complete all as specified and as directed.
M&L for CI special DI type fitting of any size up to 150mm dia such as Tee,Bend,Reducer,Tapper of any degree /size complete with provision of gasket/nut bolts etc complete all as specified and directed.
Schedule-`A' Part-XIII, External Electrification
Supply and erecting of hot dip Galvanised Octagonal poles of height 6 mtr with 130mm bottom dia and 70mm dia top made up of 3mm thick high tensile sheet along with base plate of size 225x225x12mm thick including 4 nos of M24x750mm long J type foundation bolts and 1mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make Jindal/Bajaj/Crompton Graves
M&L for cutting existing road/hard standing not exec 45x45 cm in wide and depth getting out excavated material for laying GI tube ; returning filling & well ramming watering finish surface 10 cm from top using PCC 1:3:6, including removal of surplus soil all as directed.
Supply and fixing of outdoor weatherproof IP 55 junction box of size 300 x 200x 105 mm fitted on pole complete with fixing MS clamps made of flat iron 20 mm wide x 2 mm thick, nut, bolts and washers. Provision of 4 way heavy duty connector for connection of cable including one number 6 amps MCB SP complete including cable connections with the help of suitable of lugs/thimbles all as specified and directed.
S&F Street LED Light fitting 70Watts including MS clamps including necessary bolts, Nuts, washers, anchor fasteners etc suitable for fixing security light of Cat No ENDUCITYLINERNEOSL70WLED757PASYBOTG of Havells or equivalent from Philips/Bajaj as approved by the GE, Complete all as specified and as directed.
S&F street light bracket made out of 40 mm to 50mm dia light grade GI pipe bend to shape 1.5m long with 02 Nos clamp made out of 32mm X 5mm GI strip including drilling holes bending welding and made to clamps on concrete poles.
Supply and fixing post top lantern 15 watt LED light fitting with IP-65 protection integral pole mounted on GI 50mm dia medium grade 1.5 mtr long including necessary fittings and foundation for errection and connecting with 3 core, 1.5 sqmm PVC multistranded cable from looping box to post top lantern all as specified and directed make:- Cat NO RUBYMINIPT15WLED757PSYMTOPC of havells or equivalent make of Bajaj/Crompton etc.
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase,4 wire, 415 volts, AC,50 HZ, indoor type ,cubicle ,dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet duly powder coated painting, CPRI approved, hinged door front and rear opening with locking arrangement, cable alleys, bus bar chamber and switch gear compartments, copper bus bar 300 amps rating for three phases and 200 Amps for natural duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting MCCBs/switch gears with main bus bar by using copper bus links or copper conductor flexible wires of suitable rating and connecting with terminal blocks of appropriate rating by cable lugs, thimbles etc., earthing `terminals, affixing danger notice plate, each compartment shall be numbered/lettered for indication and control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement and a clear space to be kept from bottom of panel for proper termination of cables and including cable connection to MCCBs, switch gears with necessary cable glands, lugs, nuts, bolts and washers etc, complete all as specified and directed
Supply and fix MCCB of 4 pole 25KA,415Volt,200Amps, magnetic thermal setting type for inserting in existing panel and connection with bus bar with copper conductor of suitable rating complete all as specified and as directed. Model:- DPX3 250 thermal magnetic of Legrand.
Schedule-`A' Part-XVI, Arboriculture M&L for excavating area to a depth not exceeding 300 mm in any type of soil, back filling with mixture of good quality red earth and manure (1:1) and removing excavated earth to a distance not exceeding 50m and depositing where directed, developing the entire area by placing/ decorating with plants shrubs, trees etc as per approved plan and design through aporoved agents/ agencies including preparation of artificial earth mounds, depression etc as required complete all specified and directed by the Engineer in charge with the following types of plants.
(a) Purple and white lanterns
(b) Russelia Juncea (plants shall be planted 6 to 7 nos per sqm of area to be developed
(c) Mini alamanda (plants shall be planted 6 to 7 nos per sqm of area to be developed
M&L for excavating pits of size 750x750x750mm in any type of soil back filling with mixture of good quality red earth and manure (1:1), removing excavated earth to a distance not exceeding 50m and depositing where directed and supplying and planting Royal palm trees (8 feet height) as per approved plan and design through approved agents/agencies including preparation of artificial earth mounds, depression etc as required complete all specified and directed by the Engineer in Charge.
Schedule-`A’ Part-XVII, Comprehensive Maintenance of Goods Lift Comprehensive maintenance of GOODS lifts 3000 Kgs fully automatic electrically operated gear / gealess with machine room,goods lift with carrying capacity 3000kgs to seve upto G+1 upper floors with speed of 0.5 mtr /sec, with single speed motor,with AC variable voltage variable frequency drive,with all standard accessories, automatic levelling device, ARD,system, Infra red sensors,to bring the lift car to the exact landing level,simplex automatic operation with or without attendadnt including telescopic opening stainless steel sliding doors and landing door shutters with sytainless steel finish and indicators at each floor including all lift parts which are connected for safe operation of 01 lift at OTM Accn Mankhurd (Bulk store)
1st year after expiry of defect liability period
2nd year after expiry of defect liability period
3rd year after expiry of defect liability period
United Sales Corporation
Hem Construction Company
SANKALP INFRACON
M/s Gujarat Construction Company
Anand Trading Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .