Round the clock Operation and Routine maintenance of M/s Voltas make Central Air Conditioning and Dstributed Air Conditioning System along with overhauling/breakdown and other allied works, ATPS, Anpara Sonebharda
2023_RVUNL_863672_1
02/CIMD-1/ATPS/2023-25
Open Tender
Miscellaneous Works
Fixed-rate
731 days
Anpara, Sonebhadra
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Dy. CAO, CFA and BO,ATPS,Anpara
₹77,537
19 Feb 2024
21 Nov 2023
18 Dec 2023
21 Nov 2023
16 Dec 2023
21 Nov 2023
Amount
Round the Clock Operation & Routine maintenance of Voltas make 4x126 TR & 3x86 TR capacity chiller type and 2x66 TR & 6x11 TR capacity condenser type Central Air Conditioning Plant of 3x210 M.W., ‘A’ T.P.S
Minor Maintenance.
Major Maintenance.
Fabrication of pipe bends/reducer/T-bends of different sizes after gas cutting, bending, welding, etc.
Cutting of the flanges/valves/Reusable old pipe of different sizes from old/damaged pipe etc and grinding of a rough surface.
Fabrication of flange of different sizes from MS plate after gas cutting, chipping grinding and drilling etc.
Providing tapping of different sizes in water pipeline with M.S/ C. S pipe.
Replacement of damaged/worn-out pipe of size: 12mm NB to 250 mm NB.
Replacement of damaged/worn-out Valves of size: 12mm NB to 250 mm NB.
Patching / Overlapping of different sizes up to 900 CM2.
De-silting / Cleaning of various water pipes of the following size up to 32 mm NB
De-silting / Cleaning of various water pipes of the following size 40 to 65 mm NB
De-silting / Cleaning of various water pipes of the following size 80 to 250 mm NB
Overhauling of valves in water pipeline at different location size: 12mm NB to 250 mm NB.
Providing valves /Flanges/Bend/Reducer/Tee in existing /replaced pipeline including cutting & welding of pipe and tightening with gasket, nut & bolt etc.
Replacement of damaged gasket of different sizes of a flange in the pipeline.
Fabrication & providing of pipe support/ Clamp of the pipeline.
Fabrication & Replacement of foundation base of motor and Compressor /pump.
Attending the steam leakage of impulse line and cutting welding, brazing of manifolds, adopters, Pressure Switches Pressure Gauges, and Transmitter’s line of ATRS, H.P. Bypass, and Aux. PRDS in all three units of 3X210 MW ATPS Anpara.
Providing staging to attend to the steam leakage of impulse line and cutting welding, brazing of manifolds, adopters, Pressure Switches Pressure Gauges, and Transmitter’s line of ATRS, H.P. Bypass, and Aux. PRDS in all three units of 3X210 MW ATPS Anpara if required.
Overhauling of Pumps.
Overhauling of AHUs
Overhauling of cooling Tower
Routine repair & maintenance of 1.5 Ton window/split type air conditioners along with stabilizers.
Routine repair & maintenance of 2.0 Ton window/split type air conditioners along with Stabilizers.
Routine repair & maintenance of 55000 Btu/h Air Cooled Tower Air Conditioning System.
Routine repair & maintenance of 2.0 Ton F.C.U. Installed in U.P.S. room of Unit # 1.
Overhauling work of 1.5 Ton window/split type air conditioners along with stabilizers.
Overhauling work of 2.0 Ton window/split type air conditioners along with Stabilizers.
Overhauling work of 55000 Btu/h Air Cooled Tower Air Conditioning System.
Overhauling work of 2.0 Ton F.C.U. installed in U.P.S. room of Unit # 1.
Replacement of 2.0 Ton burnt compressor by compressor of branded company such as Daikin, Hitachi, Mitsubishi along with gas charging (M12/M22).
Replacement of 1.5 Ton burnt compressor by compressor of branded company such as Daikin, Hitachi, Mitsubishi along with gas charging (M12/M22)
Gas charging (M12 / M22) in Compressor of 55000 Btu/h Air Cooled Tower Air Conditioning System.
Gas charging (M12 / M22) in 2.0 Ton Compressor
Gas charging (M12 / M22 )in 1.5 Ton Compressor
Strainer filter of 55000 Btu / h Air-Cooled Tower Air Conditioning System.
Strainer filter of 2.0 Ton Split type air conditioners
Strainer filter of 1.5 Ton window type air conditioners
Starting capacitor / running capacitor of 55000 Btu/h Air Cooled Tower Air Conditioning System.
Starting capacitor/running capacitor of 2.0 Ton Split type air conditioners
Starting capacitor/running capacitor of 1.5 Ton window type air conditioners
Thermostat of 55000 Btu/h Air-Cooled Tower Air Conditioning System.
Thermostat of 2.0 Ton window/ Split type air conditioners.
Thermostat of 1.5 Ton window/split type air conditioners.
Replacement of Cooling Coil of 1.5 Ton window/split type air conditioners.
Replacement of Condensing Coil of 1.5 Ton window/split type air conditioners.
Replacement of Outdoor unit of 1.5 split type air conditioners without compressor
Replacement of Blade of Fan blower of 5500 Btu/h Air Cooled Tower Air conditioning System
Blade of fan blower 2.0 Ton Split type air conditioners.
Blade of fan blower of 1.5 Ton window type A.C.
Blade of fan blower of 2.0 Ton F.C.U.
Fan motor capacitor of 2.0 Ton Split type air conditioners
Fan motor capacitor of 1.5 Ton window type air conditioners
Fan motor capacitor of 2.0 Ton F.C.U.
Rewinding of Fan motor of 1.5 Ton window type A.C.
Rewinding of outer blower motor of 2.0 Ton Split type A.C.
Rewinding of inner blower motor of 2.0 Ton Split type A.C.
Rewinding of Blower motor of 2.0 Ton F.C.U.
Relay of 55000 Btu/h Air Cooled Tower Air Conditioning System.
Relay of 2.0 Ton Split type air conditioners
Relay of 1.5 Ton window type air conditioners
Front grill of 1.5 Ton window type A.C.
Timer kit of1.5 Ton window type A.C.
Complete Denting/painting of1.5 Ton window type A.C.
Complete Denting / painting of 2.0 Ton Split type air conditioners.
Replacement of PCB of 2.0 Ton Split type air conditioners by PCB of branded company such as Daikin, Hitachi, Mitsubishi, Carrier, Voltas, Godrej
Replacement of Remote Kit of 2.0 Ton Split type air conditioners by Remote Kit of branded company such as Daikin, Hitachi, Mitsubishi, Carrier, Voltas, Godrej.
Bearing.
V Belt.
Top up of refrigerant of unit as per requirement.
Replacement of compressor of 55000 Btu/h Air Cooled Tower Air Conditioning System by compressor of branded company such as Daikin, Hitachi, Mitsubishi along with gas charging.
Strainer filter of 2.0 Ton Window type air conditioners
Strainer filter of 1.5 Ton split type air conditioners
Starting capacitor / running capacitor of 2.0 Ton window type air conditioners
Starting capacitor / running capacitor of 1.5 Ton split type air conditioners
Blade of fan blower 2.0 Ton window type air conditioners.
Blade of fan blower of 1.5 Ton split type A.C.
Fan motor capacitor of 2.0 Ton window type air conditioners
Fan motor capacitor of 1.5 Ton split type air conditioners
Rewinding of Fan motor of 2.0 Ton window type A.C.
Rewinding of outer blower motor of 1.5 Ton Split type A.C.
Rewinding of inner blower motor of 1.5 Ton Split type A.C.
Rewinding of outer blower motor of 55000 Btu/h Air Cooled Tower Air Conditioning System
Rewinding of inner blower motor of 55000 Btu/h Air Cooled Tower Air Conditioning System
Relay of 2.0 Ton Window type air conditioners
Relay of 1.5 Ton split type air conditioners
Replacement of PCB of 1.5 Ton Split type air conditioners by PCB of branded company such as Daikin, Hitachi, Mitsubishi, Carrier, Voltas, Godrej.
Replacement of Remote Kit of 1.5 Ton Split type air conditioners by Remote Kit of branded company such as Daikin, Hitachi, Mitsubishi, Carrier, Voltas, Godrej.
Replacement of PCB of 2.0 Ton window type air conditioners by PCB of branded company such as Daikin, Hitachi, Mitsubishi, Carrier, Voltas, Godrej.
Replacement of PCB of 1.5 Ton window type air conditioners by PCB of branded company such as Daikin, Hitachi, Mitsubishi, Carrier, Voltas, Godrej.
Replacement of PCB of 55000 Btu/h Air Cooled Tower Air Conditioning System by PCB of branded company such as Daikin, Hitachi.
Replacement of Remote Kit of 55000 Btu/h Air Cooled Tower Air Conditioning System by Remote Kit of branded company such as Daikin, Hitachi.
Replacement of Blower motor of 2.0 Ton F.C.U.
3-way gate valve motor of F.C.U.
S S JAISWAL AND BROTHERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .