Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-Finance 98 PANIYARE PURWA MAKRAND NAGAR SARAIMEERA KANNAUJ KANNAUJ UTTAR PRADESH 209726 | KANNAUJ | UTTAR PRADESH | 209726 | L1 | Accepted-Finance Accepted | |
| 2 | L2₹8.4 L+₹82,250 (10.8%)Accepted-Finance | L2 | Accepted-Finance Accepted | |
| 3 | L3₹8.8 L+₹1.2 L (15.7%)Accepted-Finance 01 KATYANI CONSTRUCTION COMPANY H NO 1 SHOP NO 1 RATAN LAL NAGAR KANPUR NAGAR UTTAR PRADESH 208022 | KANPUR NAGAR | UTTAR PRADESH | 208022 | L3 | Accepted-Finance Accepted | |
| 4 | L4₹8.9 L+₹1.3 L (17.0%)Accepted-Finance | L4 | Accepted-Finance Accepted | |
| 5 | L5₹9.0 L+₹1.3 L (17.7%)Accepted-Finance | L5 | Accepted-Finance Accepted |
Tender Value
₹11.8 L
EMD Value
₹12,000
Closing Date
2 Dec 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC-I, Kanpur
SE ETC-I, Kanpur
work
2023_UPTCL_859509_2
ET-28/ETC-I(K)/2023-24
Open Tender
Electrical Works
Fixed-rate
120 days
Kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
.PNB Account No 0727002100004177
₹12,000
8 Dec 2023
23 Nov 2023
2 Dec 2023
23 Nov 2023
2 Dec 2023
23 Nov 2023
Amount
Important Note-Quantities are approximate and may vary upto any extent on either side as per requirment of site condition or may not be excuted at all for which no extra claim shall be entertained whithin the 10%(±) tender value
Erection of following equipment/structure as per instruction manual and technical specification including shifting of material up to site of work including all associated work to complete the job.
ERECTION OF MAIN AND AUXILIARY STRUCTURE INCLUDING MINOR FABRICATION & SHIFTING
ERECTION OF 145 KV SF-6 CIRCUIT BREAKER
ERECTION OF 145 KV BUS ISOLATOR(MOTERISED) With PI
ERECTION OF 145 KV TENDOM ISOLATOR(MOTERISED) With PI
ERECTION OF 145 KV CURRENT TRANSFORMER WITH JN BOX
ERECTION OF145 KV POST INSULATOR
ERECTION OF 120 KV LIGHTING ARRESTER
ERECTION OF 33 KV VACCUM CIRCUIT BREAKER
ERECTION OF 30 KV LIGHTING ARRESTER
ERECTION OF 33 KV CT WITH JN BOX
ERECTION OF 33 KV BUS ISOLATOR
BAYWISE JUMPERING &INTERCONNECTION OF 63 MVA T/F BAY INCLUDING ALL JUMPERING OF ALL EQUIPMENT WITH SPECIFIED COND.(ZEBRA)
ERECTION OF 132 KV/33 KV 63 MVA T/F CONTROL AND RELAY PANEL AS PER TECHNICAL SPECIFICATION (SAS TYPE)
LAYING OF OPTICAL FIBER FOR SAS SYSTEM AS PER TECHNICAL SPECIFICATION (material provided by contractor )
63 MVA T/F BAY (HV &LV)INTEGRATION IN THE EXISTING ZIV SCADA SYSTEM AND ITS REAL TIME DATA VALIDATION TO SLDC LUCKNOW ALSO ICD AND CID FILE CONFIGURATION OF THE RELAY
LAYING and OF FOLLOWING SIZE COPPER CONTROL CABLE IN CABLE TRENCH From DIFFERENT CONTROL ROOM EQUIPMENT TO CONTROL PANNEL AS CABLE SCHEDULE INCLUDING CARRIAGE OF CABLE DRUM FROM STORE TO SITE
2CX2.5 SQMM
4CX2.5 SQMM
6CX2.5 SQMM
10CX2.5 SQMM
TERMINATION & CONNECTION OF ALL SIZE CABLE AS PER CABLE SCHEDULE INCLUDING DRESSING OF CONTROL CABLE MAKING NECCESARY HOLES IN PLATE AS PER REQUIRMENT SUPPLY AND FIXING CABLE GLAND ,lugs OF REQUIRE SIZE ,FERRULS AND TERMINATION WITH ALL ASSOCIATED WORK
EARTHING OF EQUIPMENT WITH DIFFERENT SIZE MS FLAT PROVIDED BY UPPTCL INCLUDING TRENCH
75X10MM MS FLAT
50X6 MM FLAT
25X6 MM FLAT
EARTHING OF LA's BY MAKING RECTANGULAR DELTA CONSISTING OF 3 MTR LONG ELECTRODE WHICH IS TO BE FEBRICATED AND PIERCING INSIDE THE GROUND AND CONNECTING ALL THE ELECTRODE WITH 75X10 MM MS FLAT 750 MM BELOW THE GROUND LEVEL INCLUDING EXCAVATION BACK FILLING LEVEL OF EARTH
PAINTING OF MS FLAT 75X10 MM,50X6 MM,25X6MM BY ONE COAT RED OXIDE AND TWO COAT BUS CREAM COLOUR ENIAMEL PAINT AFTER CLEANING THE MS FLAT
Switch yard lighting
Providing and fitting of new generation energy & environment friendly long aluminium outdoor beam street light with high power 120 watt LEDs as light source & exclusively designed polycarbonate cover along with double door type junction box complete fitting suitable for 230 volt AC input supply of CGL/Havells/Surya/Philips/Bajaj etc including wiring from junction box to light fitting point and checking of healthiness of LEDs light.
Modification of various type sub station structure by cutting and drilling of holes with welding work etc as per site requirement
Providing & fixing of 63 mva T/F name plate of 2 mm thick alluminium sheet plate size 400x200 mm with covering retro reflecting sheet base yellow colour and write feeder name plate per equipment
OTHER WORKS (RE-INSTALLATION & SHIFTING OF33 KV CAPACITOR UNIT-2X5 MVAR)
DISMENTALLING OF 33 KV BUS (RYB) WHICH IS CONNECT TO 33 KV CAPACITOR UNIT having conductor taramtulla lenth 15 meter ,33 KV CAPACITOR UNIT (2X5 MVAR) . THE JOB INCLUDE ,MAINS AND AUXILIARY STRUCTURE, 36 KV VCB,CT(03 Nos),BUS ISOLATOR(03 NOs) CAPACITOR CELL ,33 KV NCT, LIGHTING EQUIPMENT,ACDB,AFTER DISCONNECTION AND REMOVING OF ALL EXISTING,POWER CABLE CONTROL CABLE, JUMPERS ETC. FROM DIFFERENT EQUIPMENT TO CAPACITOR PANNEL,ACDB. WORK ALSO INCLUDING ROLLING THE DISMENTALLED CONTROL CABLE FROM TRENCH AND SHIFTING IT FROM SITE TO STORE AS PER S/S INCHARGE
SHIFTING OF 33 KV CAPACITOR UNIT (2X5 MVAR) . THE JOB INCLUDE ,36 KV VCB,CT(03 Nos),BUS ISOLATOR(03 NOs) CAPACITOR CELL ,33 KV NCT, LIGHTING EQUIPMENT ,REACTOR, SHIFTING OF MAIN AND AUXILIARY STRUCTURE,ACDB ,FITTINGS UPTO 100 MTR
ERECTION OF EXISTING 33 KV CAPACITOR UNIT (2X5 MVAR) . THE JOB INCLUDE ,36 KV VCB,CT(03 Nos),BUS ISOLATOR(03 NOs) CAPACITOR CELL ,33 KV NCT, LIGHTING EQUIPMENT ,REACTOR, MAINS AND AUXILIARY STRUCTURE,ACDB AND RECONNECTION TERMINATION SAME AS BEFORE WITH NEW GLAND ,LUGS ,FERULS,DRESSING ETC
Stringing OF 33 KV BUS (RYB) WHICH IS CONNECT TO 33 KV CAPACITOR UNIT having conductor taramtulla lenth 15 meter SAME AS BEFORE as per direction of s/s incharge
INTERCONNECTION OF 33 KV CAPACITOR UNIT (2X5 MVAR) INCLUDING ALL JUMPERING OF ALL EQUIPMENT WITH SPECIFIED COND.(PANTHER)
LAYING OF FOLLOWING SIZE COPPER CONTROL CABLE IN CABLE TRENCH FOR DIFFERENT CONTROL ROOM EQUIPMENT TO CONTROL PANNEL, YARD EQUIPMENT AS CABLE SCHEDULE INCLUDING CARRIAGE OF CABLE DRUM FROM STORE TO SITE
2CX2.5 SQMM
4CX2.5 SQMM
6CX2.5 SQMM
TERMINATION & CONNECTION OF OF FOLLOWING SIZE CABLE AS PER CABLE SCHEDULE INCLUDING DRESSING OF CONTROL CABLE MAKING NECCESARY HOLES IN PLATE AS PER REQUIRMENT SUPPLY AND FIXING CABLE GLAND OF REQUIRE SIZE ,FERRULS AND TERMINATION WITH ALL ASSOCIATED WORK
EARTHING OF EQUIPMENT AND STRUCTURE WITH DIFFERENT SIZE MS FLAT PROVIDED BY UPPTCL INCLUDING TRENCH
50X6 MM FLAT
25X6 MM FLAT
PAINTING OF MS FLAT 50X6 MM,25X6MM BY ONE COAT RED OXIDE AND TWO COAT BUS CREAM COLOUR ENIAMEL PAINT AFTER CLEANING THE MS FLAT
63 MVA T/F ERECTION AND COMMISSIONING WORK
Shifting of main tank of 63 MVA T/F from unloading point to T/F plinth (up to 20 MtR)
Additional shifting of 5 meter or part there of (63 MVA T/F main tank)
Complete erection of 63 mva by erection of radiators conservator tank HV/LV/N bushing and its turrets,connecting all pipe line ,erection of fans, control cable ,motor drive mechanism of RTCC pannel, cooling fan etc and all other associated work for satisfactorly completeion of work .
Filling of transformer oil from oil drum to main tank of 63 MVA T/F
Filling of transformer oil from oil drum to main tank of 63 MVA T/F and Centrifusing of complete Transformer oil in main tank of the transformer taking the IR/BDV value of Transformer oil at an interval of 4 hrs as per norms till the desire value of BDV/PPM are obtained (Centrifusing machine along with operator shall be arranged by the contractor at his own cost)
Erection of RTCC pannel of 63 MVA T/F as per instruction of s/s incharge. The job include its fitting , cutting of its pocket etc.
Termination of cable connection in cooling fans/RTCC/marshallingbox including re-dressing /ferruling etc as per drawing
Earthing of 63 MVA 132/33 KV transformer body ,MB,OLTC/RTCC with ms flat to be provided by the department and connecting the same with main earth mat at 2 places as required
Making Delta earthing Rectangular with 03 mtr long electrode which to be provided by department and connecting with neutral of 63 MVA T/F and green bus painting of ms flat size 75x10 mm (each for HV,LV,Neutral
Testing of transformer oil after centrifusing through CPRI lab along with carriage of sample for -BDV, PPM
M/s Abhinav Enterprises
Katyani Construction Co.
TAJ ENTERPRISES
M/S DHIRENDRA SINGH
Hi-tech power transmission
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .