Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | ₹43.0 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹60.8 L+₹17.8 L (41.3%)Rejected-Finance B 4 PLOT NO 114 GURU KIRPA BUILDING SHIV SHAKTI NAGAR TN MISHRA MARG NIRMAN NAGAR JAIPUR JAIPUR RAJASTHAN JAIPUR RAJASTHAN 302019 | JAIPUR | RAJASTHAN | 302019 | ₹60.8 L+₹17.8 L (41.3%) | L2 | Rejected-Finance NOT L1 |
| 3 | Rejected-Technical KANCHIPURAM TAMIL NADU 600064 UDYAM TN 02 0028088 | CHENGALPATTU | TAMIL NADU | 600064 | - | - | Rejected-Technical Bidder failed to submit in their Name Valid Electrical Contractors License granted by any State UT Govt of India as per Regulation 30 of Regulation and Condition for issuing certificate of competency under Regulation 29 of CEA |
| 4 | Rejected-Technical | - | - | Rejected-Technical Bidder failed to submit in their Name Valid Electrical Contractors License granted by any State UT Govt of India as per Regulation 30 of Regulation and Condition for issuing certificate of competency under Regulation 29 of CEA |
| 5 | Rejected-Technical | - | - | Rejected-Technical Bidder failed to submit in their Name Valid Electrical Contractors License granted by any State UT Govt of India as per Regulation 30 of Regulation and Condition for issuing certificate of competency under Regulation 29 of CEA |
Tender Value
₹56.2 L
EMD Value
₹14,000
Closing Date
21 May 2026, 5:00 pmClosed
DGM MandC ERPL Kolkata
34A Nirmal Chandra Street. 7th floor IBP House, Kolkata-700013
Annual Rate Contract for RCP SV Maintenance of CP Cathodic Protection and Electrical under Jurisdiction of ERPL BOLPUR Including BOLPUR Station
2026_ERKLK_189764_1
ERKLC2607
Open Tender
Electrical Works
Works
730 days
ERPL BOLPUR and 5 RCP Location
Please refer Tender documents.
6 documents required · 6 mandatory
₹14,000
21 Aug 2026
7 May 2026
22 May 2026
7 May 2026
21 May 2026
7 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ. | |||||
| 3ELECTRICAL ARC WORKS | |||||
| 10 | Removal of sand from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or putting it back into the same trench or in a new cable trench as per drawing within a lead of 50 meteres all complete with labour and materials as per the direction of the Engineer-in- Charge. | 1 | SQM | 61.28 | ₹61.28 |
| 10.01 | Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge. Overall diameter upto 35 MM | 1 | M | 22.66 | ₹22.66 |
| 10.02 | Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge Overall diameter > 35 MM but upto 55 MM | 1 | M | 29.4 | ₹29.4 |
| 10.03 | Dismantling of Electrical wiring (comprising of single or twin core PVC wires upto 6 Sq mm and single earth wire upto 6 SWG) along with its connected accessories like junction boxes, surface conduits, battons, switch boards etc. | 1 | M | 19.11 | ₹19.11 |
| 10.04 | Supply, fixing and connection of 250 V below given mosaic modular wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge. (Accessories to have ISI mark)230 V AC 1 module buzzer | 20 | EA | 210.59 | ₹4,211.8 |
| 10.05 | Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-non regulated programmable | 1 | EA | 3,552.73 | ₹3,552.73 |
| 10.06 | Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-regulating programmable with day light dimming | 1 | EA | 4,950.41 | ₹4,950.41 |
| 10.07 | Supply, installation,testing and commissioning of occupancy sensor based on microwave technology-non regulated programmable | 1 | EA | 6,741.78 | ₹6,741.78 |
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
Bidders_help_Document_for_Preferencial_Bidding_20230207_v1.pdf
Additional Documents • 0.82 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
ERKLC2607_compressed.pdf
Tender Documents • 17.14 MB
BOQ_200039.xls
BOQ • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .