Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹44.2 LAccepted-AOC | ₹44.2 L Quoted ₹48.6 L | L2 | Accepted-AOC L1 Bidder |
| 2 | L1₹47.5 LRejected-Finance SAYED MUSTAFA ALI ROAD HAKIMPARA P O SILIGURI 734001 DISTT DARJEELING W B | JALPAIGURI | WEST BENGAL | 734001 | ₹47.5 L | L1 | Rejected-Finance Other than L1 Bidder |
| 3 | L3₹49.7 LRejected-Finance | ₹49.7 L | L3 | Rejected-Finance Other than L1 Bidder |
| 4 | L4₹50.1 LRejected-Finance 1ST FLOOR H NO 29 A SESHAADHRI NILAY NEOG PATH ANANDA NAGAR BEHIND DONA PLANET GS ROAD GUWAHATI 05 ASSAM | ₹50.1 L | L4 | Rejected-Finance Other than L1 Bidder |
| 5 | L5₹50.4 LRejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | ₹50.4 L | L5 | Rejected-Finance Other than L1 Bidder |
| Sl No | Description | Qty | Unit | Barua Trading Co. L2 | Manish Ray and Co. L3 | Power Tools and Engineering L4 | KMT INDUSTRIES L6 | BARUA & CO L1 | M/S Kharya Associates L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of ACSR or AAC conductors complete all as specifed and directed. | 0.5 | Qtl | 510 ₹255 | 525 ₹262.50 | 530 ₹265 | 541 ₹270.50 | 500 ₹250 | 535 ₹267.50 |
| 2.00 | Dismantling of cross arms of MS channel or angle sections etc complete all as specified and directed. | 0.5 | Qtl | 516 ₹258 | 526 ₹263 | 528 ₹264 | 541 ₹270.50 | 500 ₹250 | 535 ₹267.50 |
| 3.00 | Dismantling of insulators any type , any size complete all as specified and directed. | 12 | Each | 11 ₹132 | 12 ₹144 | 10.5 ₹126 | 12 ₹144 | 10 ₹120 | 12 ₹144 |
| 4.00 | Disconnecting and taking down the worn out jumpers in 33 KV yard and supply and fix new jumpers cutting to adequate length of ACSR conductor the cost of ACSR contractor deemed to the quoted rate complete all as specified and directed. | 2 | Each Job | 1,040 ₹2,080 | 1,100 ₹2,200 | 1,050 ₹2,100 | 1,110 ₹2,220 | 1,000 ₹2,000 | 1,100 ₹2,200 |
| 5.00 | Taking down the defective power transformer Capacity 3000KVA, 33/11KV from existing site with the help of Hydra or by crane etc including disconnecting all electrical and mechanical connections from the site and loding onto the vehicle, carrying to nearest workshop distance not exceeding 100 KM for repair and replacement of old worn out u/s items as well as winding etc including unloading at the workshop by engaing hydra.complete all as specified and directed. | 1 | Each | 40,400 ₹40,400 | 41,200 ₹41,200 | 41,800 ₹41,800 | 42,290 ₹42,290 | 40,000 ₹40,000 | 42,000 ₹42,000 |
| 6.00 | M & L for comprehensive maintenance of 33 KV Isolators switch set of three at 33 KV Yard and new BH 33 KV yard and taking shutdown from 33 KV S/S Shivmandir disconnect from existing isolator carefully clean the male and female contact with CRC spray thorouhghly, tightening the nut, bolts and chek the female and male contact, clean and change the burn out insulator and apply petroleum jelly usage all the movable contact of isolator and repair or replacement all the worn out parts by new spare parts and reassembling the same in position and re-connecting the HT connection complete in functional order all as specified & directed.
Note :- (i) Cost of spare parts i.e Female contact, P G Clamp etc shall be measured and paid separately. (ii) All the exising nut, bolt and washers of isolator should be replace with stainless steel nut, bolt and washers as per existing size at site . The cost of minor spare parts i.e nuts and bolts, washers , grommets, clips, pin etc essentially required to make the serviceable shall be deemed to be included in the quoted rate. | 7 | Each Job | 20,200 ₹1.4 L | 20,850 ₹1.5 L | 21,150 ₹1.5 L | 21,450 ₹1.5 L | 20,000 ₹1.4 L | 21,350 ₹1.5 L |
| 7.00 | Supply only Female clamp suitable for 33 KV line isolator switch at 33 KV Main receiving Station complete all as specified and directed. | 2 | Each | 8,650 ₹17,300 | 8,900 ₹17,800 | 9,050 ₹18,100 | 9,200 ₹18,400 | 8,500 ₹17,000 | 9,100 ₹18,200 |
| 8.00 | Supply only PG Clamps/ T Connector including nut and bolt of suitable size made of stainless steel suitable for 33 KV grid complete all as specified and as directed. | 3 | Each | 408 ₹1,224 | 420 ₹1,260 | 427 ₹1,281 | 460 ₹1,380 | 400 ₹1,200 | 445 ₹1,335 |
| 9.00 | Supply and fixing new aluminium conductor steel reinforced (ACSR), stringing and jointing on poles including providing clamps/nut and bolt/binding wire etc. complete all as specified and as directed.
Note :- (i) Weight of ACSR or all aluminium conductor drawn for OH lines is to be measured by measuring tap horizontal distance between centres of two addacent poles and compounding the weight of conductor of that size and length and 3 % extra added for sag, jointing, jumpers and binding etc. (ii) Weight of conductor shall be calculated from tables given in the relevant I.S.etc complete all as specified and directed. | 0.5 | Qtl | 20,400 ₹10,200 | 20,800 ₹10,400 | 21,100 ₹10,550 | 21,510 ₹10,755 | 20,000 ₹10,000 | 21,300 ₹10,650 |
| 10.00 | Re-stringing of existing ACSR conductor of any size any type as required sag fixed on OH line & insulators/cross Arms on poles properly binding on insulator with alumminum conductor. etc all as specified and directed. | 2 | Qtl | 1,530 ₹3,060 | 1,575 ₹3,150 | 1,600 ₹3,200 | 1,620 ₹3,240 | 1,500 ₹3,000 | 1,650 ₹3,300 |
Updated dates
Tender Value
₹46.3 L
EMD Value
₹92,700
Closing Date
19 Jan 2026, 6:00 pmClosed
CWE Bengdubi
Headquarters Commander Works Engineer Bengdubi Post-Bengdubi Distt-Darjeeling (WB) PIN- 734424
REPAIR REPLACEMENT SERVICING MAINTENANCE AND IMPROVEMENT OF 33 KV HT MRS INCLUDING REPAIR OF 33 11 KV TRANSFORMER , CABLE , POLE, VCBs SWITCH GEAR, INCLUDING CALIBRATION AND TESTING OF RELAYS AND ALLIED EORKS AT BENGDUBI MIL STN UNDER GE BENGDUBI
2025_MES_744088_1
8327/B/E8
Open Tender
Civil Works
150 days
Bengdubi
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE Bengdubi
₹92,700
HQ CWE Bengdubi
11 Mar 2026
11 Dec 2025
21 Jan 2026
11 Dec 2025
19 Jan 2026
6 Jan 2026
22 Dec 2025
Dismantling of ACSR or AAC conductors complete all as specifed and directed.
Dismantling of cross arms of MS channel or angle sections etc complete all as specified and directed.
Supply and fixing new aluminium conductor steel reinforced (ACSR), stringing and jointing on poles including providing clamps/nut and bolt/binding wire etc. complete all as specified and as directed. Note :- (i) Weight of ACSR or all aluminium conductor drawn for OH lines is to be measured by measuring tap horizontal distance between centres of two addacent poles and compounding the weight of conductor of that size and length and 3 % extra added for sag, jointing, jumpers and binding etc. (ii) Weight of conductor shall be calculated from tables given in the relevant I.S.etc complete all as specified and directed.
M&L for cross arms in replacement, bracing, supports, clamps and brick plates, fabricated from staructural steel section including nut bolts washers including welding bending, cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide complete all as specified and as directed.
Supply and rewinding with new E.C Grade TPC Copper Wire size and thickness as per the OEM specification to obtain the rated impedance values and KVA rating as specified by the OEM for the transformer capacities 3000 KVA , 33/11 KV for making of HV coils (33 kV) including the class 'A' insulating Materials, such as Glass Tube, Bakelight Tube, Glass Tape , Pre-compressed Board, Crape Paper,Craft paper, Presspahn Paper, Cotton tape, Varnish etc. IEC standard, high density laminated board confirming IEC 60641-3-1 type B 3.1A of required thickness quality all as specified and as directed.
All as per item ser No 25 above but EC grade DPC Copper wire making of 11 KV coils all as pe
Supply and topping up of Mineral lnsulating transforrner Oil for main tank and OLTC tank as per IS:335:2018 break down voltage not less than 60 KV as per IEC 60156:2018 complete all as specified and directed. Note:- Quoated rate shall also be deemed to include for testing of transformer oil from CPRI / Govt. approved lab as per relevant IS and submission of necessary test reports.
S&F plates of Grade Fe 410-W (Gde E-250) quality - B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attacment including welding or riveting etc in replacement of RCC type duct cover as directed by Engineer-in-charge for using as cable trench plate all as directed
M&L for earthing complete with medium grade galvanized Iron (GI) pipe electrode of 100 mm bore and 6.00 mtrs length burried directly in ground earth through vertical boring of dia 300 mm and filled with upto 5 mtrs with mix of charcoal or coke and common salt in and around the GI pipe electrode and connected to galvanised iron earth strip 32x6mm by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth strip protected by 40mm bore light grade GI pipe and other end connected to earthing test point or VCB/transformer/LA as directed including PCC earth pit chamber of internal dimension (300x300x300) mm and having wall thickness 100 mm using PCC (1:2:4) type B1 alongwith RCC (1:2:4) type B1 precast cover 50 mm thick reinforced with 8 mm TMT bars both way @100mm c/c including one lifting handle including necessary boring and earth work and refilling of black soil good conductor of earth and necessary testing and dismantling of old one complete all as specified and directed.
Supply and fixing GI pipe outer dia tubing, light grade, 150 mm bore for protection of cable under road crossing, across drain, along electric pole or floor /wall etc, complete incliding taking out existing pipe, complete all as specified and directed.
Supply jointing and testing in repairs cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination, cold shnik type joint complete with and including jointing materials and accessories suitable for 33KV XLPE insulated armoured aluminium cable of size 400 Sqmm 3 core, complete all as specified and as directed.
Supply, jointing and testing in repairs cable jointing kit for 33 KV (Earthed) grade cable for straight through joint heat shrink complete with and including jointing materials and accessories suitable for 33KV XLPE insulated armoured aluminium cable of size 400 Sqmm 3 core, complete all as specified and as directed.
M & L in repair of PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm 4 core 1100 Volts grade, in the trenches /ducts/along wall / floor /pole/equipment /on floor etc, complete all as specified and directed.
M & L in repair of PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm 12 core 1100 Volts grade, in the trenches /ducts/along wall / floor /pole/equipment /on floor etc, complete all as specified and directed.
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
Returning, filling in, including spreading,leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tender27.pdf
Tender Documents • 1.27 MB
BOQ_833185.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid