SPL REPAIR TO REPLACEMENT OF SUMMER APPLIANCES AGAINST BER AT AGE EM UNDER GE JHANSI
2026_MES_786376_1
CWE/JHA/J/TOKEN/71 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JHANSI
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE JHANSI
₹1.6 L
Yes
25 Aug 2026
25 Aug 2026
26 Sept 2026
25 Aug 2026
24 Sept 2026
16 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commisioning of air cooled inverter type split Air conditioner of 1.5 TR capacity minimum 5 star comprising of one indoor and one outdoor unit, comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 Volts AC, single phase, 50 Hz, having Five Star rated and including inlet/outlet copper pipe for refrigerant between indoor & outdoor unit with flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed.
Note: The cost of making hole / opening for passing inlet/ outlet copper pipes and electrical cord and making good surface as original by plastering / applying putty/ whitewash/colour/distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
Make: Voltas, Hitachi, Daikin, Carrier | 43 | Each | - | - |
| 2 | Supply, installation, testing and commisioning of air cooled inverter split Air conditioner of 2 TR capacity minimium 4 star comprising of one indoor and one outdoor unit, comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 Volts AC, single phase, 50 Hz, having Five Star rated and including inlet/outlet copper pipe for refrigerant between indoor & outdoor unit with flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed.
Note: The cost of making hole / opening for passing inlet/ outlet copper pipes and electrical cord and making good surface as original by plastering / applying putty/ whitewash/colour/distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. | 1 | Each | - | - |
| 3 | Supply and fix heavy duty Mild steel powder coated wall mount bracket with grouting bolts complete set suitable for wall mounting of outdoor unit of 1.5 / 2.0 TR capacity split type AC complete all as specified and directed. | 44 | Set of two | - | - |
| 4 | M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4.0 sqmm + 1 run x 4.0 sqmm with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed.
Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. | 450 | RM | - | - |
| 5 | M&L for Circuit/submain wiring alongwith earth wire 2 runs x 2.5 sqmm + 1 run x 2.5 sqmm with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed.
Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. | 425 | RM | - | - |
| 6 | S&F, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A , 240 volts, complete all as specified and directed. | 89 | Each | - | - |
| 7 | Supply and fix MCB distribution board, SPN, 4 way, 240 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. | 44 | Each | - | - |
| 8 | S& F MCB SPN 40- 63 Amp, 10 KA, 'C' curve, 240 V, 50 Hz complete all as specified and directed. | 44 | Each | - | - |
| 9 | S& F MCB SP 6-32 Amp, 10 KA, 'C' curve, 240 V, 50 Hz complete all as specified and directed. | 124 | Each | - | - |
| 10 | Supplying, instaling, connecting and testing of water cooler, fully stainless steel, non-corrosive, electric driven (single phase), 230V, 50 Hz having approx storage capacity 80 Ltrs self contained drinking water cooler with (Non - CFC refrigerent) energy efficient compressor and Nominal cooling capacity of 40 Ltrs/Hrs including connecting of PVC Nylone braided pipe etc complete all as specified and directed.
Make: Voltas, Blue Star, Godrej | 35 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_881226.xls
BOQ • 0.61 MB
Tenderdocuments71.pdf
Tender Documents • 1.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .