Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.4 L+₹6.5 L (21.8%)Rejected-Finance | L2 | Rejected-Finance Other Than Being Lowest | |
| 3 | L3₹38.6 L+₹8.7 L (29.1%)Rejected-Finance | L3 | Rejected-Finance Other Than Being Lowest | |
| 4 | L4₹41.1 L+₹11.2 L (37.3%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | Unity Enterprises L1 | Colaba Group Works L3 | SHREE JAGDISH FURNITURE CO. L4 | Nadim Sami Qureshi L2 |
|---|---|---|---|---|---|---|---|
| 1.00Note : 1. The tenderer shall note that before quoting his unit rate, all items of works shall be executed in high rise building, including provision of necessary scaffolding & safety measures. 2. Removal of Debris out side MoD land and site clearance as per the direction of Engineer- in- Charge. 3. Safety eqpt to be carried all the time. 4. Scaffolding wherever reqd deemed to be included in quoted rates. 5. Contractor is solely responsible for any defect or after working situation . 6.The contractor shall submit affidavit for 05 year warranty for structural repair carried out by the firm for the portion of work (Item No. 02 to15). Pre-final RAR/Final Bill shall be released only after submission of warranty. | |||||||
| 2.00 | RELIEVING STRUCTURAL MEMBERS Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately For item No 01 to 11 structural repair and strengthening, rehabilitation shall be applied by the authorised applicator only. | 100 | Nos | 400 ₹40,000 | 550 ₹55,000 | 247 ₹24,700 Lowest | 270 ₹27,000 |
| 3.00 | Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on external and internal areas, etc carefully with chisel and hammer Providing and applying ‘Rusticide SS’ Rust passivator or Techno comercial equivalent as aproved to existing r/f. bars Including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed.Providing and applying two coats of Rust Preventor slurry made out of “Polyalk Fixoprime” or techno comercial equivalent and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or Techno comercial equivalent and cement in proportion 1:1 to concrete and r/f substrates complete as directed Providing and applying “Polyalk EP” or Techno comercial equivalent . Polymer Modified Cement Mortar in Required proportions(1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering. | 100 | Sqm | 125 ₹12,500 | 600 ₹60,000 | 77 ₹7,700 Lowest | 450 ₹45,000 |
| 4.00 | Providing and laying in position reinforced cement concrete of specified grade cement with granite/quartzite/gneiss metal mixing in concrete mixer including bailing out water,compacting, finishing surface, curing and including the cost of centering and shuttering a all level Nominal Mix of 1:2:4 (1 cement OPC: 2 coarse sand : 4 graded crushed stone aggregate 20 mm nominal size. | 0.5 | Cum | 7,000 ₹3,500 Lowest | 7,200 ₹3,600 | 8,888 ₹4,444 | 7,600 ₹3,800 |
| 5.00 | Supplying, Drilling/Cleaning hole and injecting Hilti make ETA Approved HY-200-R chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. HY200 -10 mm dia 200mm depth.(Rates includes scaffolding cost )
Make :-Asapproved | 10 | Nos | 800 ₹8,000 | 650 ₹6,500 | 405 ₹4,050 Lowest | 900 ₹9,000 |
| 6.00 | FILLING AND REINSTATING OF SEPARATION CRACKS Opening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into ‘’V’’ Grooves 2’’ to 3’’ from the either side of the cracks and 20-25mm wide and 15-20mm in depth by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
Make :-As approved | 210 | RM | 80 ₹16,800 Lowest | 140 ₹29,400 | 125 ₹26,250 | 200 ₹42,000 |
| 7.00 | Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of “Polyalk EP”and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks /Grooves by Providing and applying “Polyalk EP” Polymer Modified Mement Mortar (or Techno comercial equivalent as specified in the List of Brand names) in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed.
Make : As aproved | 210 | RM | 80 ₹16,800 Lowest | 390 ₹81,900 | 141 ₹29,610 | 170 ₹35,700 |
| 8.00 | M&L for Drilling holes of required size upto 16 mm Diameter and up to 50mm depth in concrete and cleaning the same complete all as specified and directed. | 300 | Nos | 35 ₹10,500 Lowest | 80 ₹24,000 | 55 ₹16,500 | 45 ₹13,500 |
| 9.00 | Providing and fixing 12 mm diameter aluminum/PVC injection nipples and securing the same as directed & Providing and injecting Cementitious Grout using CEBEX-112 additive of ‘Fosroc’ or Techno comercial at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete.
Make :-As approved | 300 | Nos | 75 ₹22,500 Lowest | 340 ₹1,02,000 | 147 ₹44,100 | 225 ₹67,500 |
| 10.00 | Providing & fixing Epoxy Dipped Shear Keys of 10mm dia and 4" to 6" length in columns before jacketing and Micro concreting as per Consultants Instructions and directions. Make :-As approved | 100 | Nos | 25 ₹2,500 Lowest | 120 ₹12,000 | 165 ₹16,500 | 450 ₹45,000 |
Tender Value
₹46.6 L
EMD Value
₹93,300
Closing Date
16 Apr 2026, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIR TO TOILETS AND ROOF TOP OF BUILDING NO P-78 AT INHS ASVINI
2026_MES_758270_1
8025/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) Asvini
Class D
Category a (i)
7 documents required · 7 mandatory
₹500
AGE (I) Asvini
₹93,300
Yes
7 Jul 2026
28 Mar 2026
18 Apr 2026
28 Mar 2026
16 Apr 2026
11 Apr 2026
28 Mar 2026 - 4 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | RELIEVING STRUCTURAL MEMBERS Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately For item No 01 to 11 structural repair and strengthening, rehabilitation shall be applied by the authorised applicator only. | 100 | Nos | - | - |
| 3 | Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on external and internal areas, etc carefully with chisel and hammer Providing and applying ‘Rusticide SS’ Rust passivator or Techno comercial equivalent as aproved to existing r/f. bars Including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed.Providing and applying two coats of Rust Preventor slurry made out of “Polyalk Fixoprime” or techno comercial equivalent and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or Techno comercial equivalent and cement in proportion 1:1 to concrete and r/f substrates complete as directed Providing and applying “Polyalk EP” or Techno comercial equivalent . Polymer Modified Cement Mortar in Required proportions(1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering. | 100 | Sqm | - | - |
| 4 | Providing and laying in position reinforced cement concrete of specified grade cement with granite/quartzite/gneiss metal mixing in concrete mixer including bailing out water,compacting, finishing surface, curing and including the cost of centering and shuttering a all level Nominal Mix of 1:2:4 (1 cement OPC: 2 coarse sand : 4 graded crushed stone aggregate 20 mm nominal size. | 0.5 | Cum | - | - |
| 5 | Supplying, Drilling/Cleaning hole and injecting Hilti make ETA Approved HY-200-R chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. HY200 -10 mm dia 200mm depth.(Rates includes scaffolding cost )
Make :-Asapproved | 10 | Nos | - | - |
| 6 | FILLING AND REINSTATING OF SEPARATION CRACKS Opening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into ‘’V’’ Grooves 2’’ to 3’’ from the either side of the cracks and 20-25mm wide and 15-20mm in depth by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
Make :-As approved | 210 | RM | - | - |
| 7 | Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of “Polyalk EP”and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks /Grooves by Providing and applying “Polyalk EP” Polymer Modified Mement Mortar (or Techno comercial equivalent as specified in the List of Brand names) in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed.
Make : As aproved | 210 | RM | - | - |
| 8 | M&L for Drilling holes of required size upto 16 mm Diameter and up to 50mm depth in concrete and cleaning the same complete all as specified and directed. | 300 | Nos | - | - |
| 9 | Providing and fixing 12 mm diameter aluminum/PVC injection nipples and securing the same as directed & Providing and injecting Cementitious Grout using CEBEX-112 additive of ‘Fosroc’ or Techno comercial at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete.
Make :-As approved | 300 | Nos | - | - |
| 10 | Providing & fixing Epoxy Dipped Shear Keys of 10mm dia and 4" to 6" length in columns before jacketing and Micro concreting as per Consultants Instructions and directions. Make :-As approved | 100 | Nos | - | - |
| 11 | M&L for Providing, cutting, bending and fixing Additional Reinforcement in position steel reinforcement of specified/required sizes and shapes in the form or main rebars, stirrups & rings, distribution rebars etc., and tying them to shear connectors using GI binding wire. The additional rebars should be coated with TWO coats of Anti Corrosive protective coating & dry sand to be sprinkled on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Engineers. Make :- As approved | 500 | Kg | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_849319.xls
BOQ • 1.56 MB
8025.rar
Tender Documents • 2.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .