Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC | ₹2.2 Cr | L1 | Accepted-AOC Accepted being L1 bidder. |
| 2 | L2₹2.3 Cr+₹19.2 L (8.94%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹2.3 Cr+₹19.2 L (8.94%) | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | L3₹2.4 Cr+₹30.0 L (13.9%)Rejected-Finance 84 POLO HILLS OPPOSITE SBI BRANCH EAST KHASI HILLS SHILLONG MEGHALAYA 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | ₹2.4 Cr+₹30.0 L (13.9%) | L3 | Rejected-Finance Rejected being higher than L1 bidder. |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
21 Aug 2023, 6:00 pmClosed
CHIEF ENGINEER AF
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVISION OF LIVING IN ACCN FOR OFFICERS AT AF STN LAITKOR PEAK
2023_MES_574477_4
88981/SHL/E8
Open Tender
Civil Works
Lump-sum
540 days
Laitkor Shillong
As per tender documents
6 documents required · 6 mandatory
₹1,000
GE I AF SHILLONG
₹2.4 L
Yes
28 Nov 2023
20 Jul 2023
23 Aug 2023
20 Jul 2023
21 Aug 2023
7 Aug 2023
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of Buildings are given here-in-after-
Construction of one block of Officers living in Accn for 04 Flt Lt in Double Storey configuration with permanent specification including RCC framed construction, ATT, mosquito proofing, seismic provisions, APP roof treatment, External exterior emulsion paint etc all as directed and shown in drawings.
Construction of one block of Officers living in Accn for 03 Flt Lt & two wheeler parking for 07 Nos in Double Storey configuration with permanent specification including RCC framed construction, ATT, mosquito proofing, seismic provisions, APP roof treatment, External exterior emulsion paint etc all as directed and shown in drawings.
Construction of one block of Servant quarters Accn for 04 servant in Double Storey configuration with permanent specification including RCC framed construction, ATT, mosquito proofing, seismic provisions, APP roof treatment, External exterior emulsion paint etc all as directed and shown in drawings.
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (HARD STANDING ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (EXTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (FENCING AND GATE ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -X (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
ARBORICULTURE M&L preparing the surface by ploughing the area upto 30cm deep and removing the boulder or stone and mixing with good earth for preparing the ground to receive the grass plantation mexican carpet grass including putting necessary application of different fertilizer and compost mixture @ 0.1 kg per sqm complete and maintenance of the lawn for 30 days or more till grass forms a thick tawn free from weeds complete including irrigating the area by sprinkling water as required all as directed.
M&L preparing the surface by ploughing the area upto 30cm deep and removing the boulder or stone and mixing with good earth for preparing the ground to receive the plantation and planting different types of flower plants including necessary application of different fertilizer and composite mixture @ 0.1kg per sqm complete and maintenance of the plant for 30 days or more till the plants growth upto certain height including irrigating the area with proper method complete all as directed.
INTERNAL WATER SUPPLY M & L for 15 mm bore brass angle stop cock , chromium plated high pressure with capstan head long shank screwed down complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Supply and fix double compression brass gland for fixing armoured cable of size 3.5 core 95 sq mm to 120 sq mmcomplete all as specified and directed.
M & L for earthing complete with Copper earth plate 60 cm X 60 cm X 3.15 mm thick buried vertically in ground to depth not less than 2 25 metres deep below ground level with top edge of earth plate not less than 1.5 m below ground level, connected to copper earth strip of size 20mmx3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continuous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGICI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part - (2009) drawing and connection to earth test point including testing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
Supply, installing, testing and commissioning, factory made and tested (inci CPRI type test certified), LT feeder pillar box of appropriate dimensions (as per Indian Electricity rules)(1.5x1.2x 6m) to accommodate following components, indoor type, platform/floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 02 Nos bus bar chambers with high conductivity copper alloy installed on porcelain insulators. The panel shall be dust and vermin proof, IP 43 class protection and made of 2.0mm thick CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:- (a) Bus bar of high conductivity copper alloy for four pole including PVC heat shrink sleeves (RYB & N ) - 02 Sets (b) MCCB four pole 350 Amp confirming to IEC 60947-2 & IS — 13947-3 thermal magnetic release and adjustable over load setting 0.8 — 1 0 x In and adjustable short circuit setting 6 — 10 x In and rupturing capacity 35 KA at 415 V AC , 50 Hz complete – 01 No. (c) MCCB four pole 125 Amp confirming to IEC 60947-2 & IS — 13947-3 thermal magnetic release and adjustable over load setting 0.8 — 1.0 x In and adjustable short circuit setting 6 — 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete – 04 Nos (d) MCCB four pole 63 Amp confirming to IEC 60947-2 & IS — 13947-3 thermal magnetic release and adjustable over load setting 0.8 — 1.0 x In and adjustable short circuit setting 6 — 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete – 01 Nos. (e.) 3 Pole power contactor type ML-4, upto 7OAmps AC3 rating with coil voltage 415 volts.-01 No (f) Astro pro street light timer switch suitable for 120-240 volts AC single phase based on latitude and logitude.-01 No (g) Digital multifunction meter, accuracy class 1.0 - 02 Nos (h) R-Y-B phase indicator LED lamp - 06 Nos
M&L for HT cable route marker made out of cast iron duly painted with red colour over a coat of red oxide primer all as directed.
M&L for erection of LT cable route marker made out of cast iron duly painted with blue colour over a coat of red oxide primer and with 40X6 mm MS flat iron stand for erection all as directed.
S&F sheet metal enclousures for vertical TPN DBs vertical type when 100 Amps MCCB to be used for incommer MCB to be used for 415 volts, 4 way earth & neutral link, TPN double door, IP-54 complete all as specified and directed.
S&F MCCB four pole 100 Amp confirming to IEC60947-2 & IS-13947 thermal magnetic release and adjustable over load setting 0.8-1.0 x In and adjustable short circuit setting 6-10 x In and rapturing capacity 25 KA at 415 V AC, 50 Hz complete all as specified and directed.
M & L for earthing complete with Gi earth plate 60 cm X 60 cm X 6 mm thick buried) vertically in ground to depth not less than 2.25 metres deep below ground level. with top edge of earth plate not less than 45 m below ground level, connected to galvanised earth lead wire of size 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continuous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm Be and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 72mm dia, PGI/CI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part | (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate (ii) The cost of excavation earth work is included in the quoted rate.
Supply, installation, testing and commissioning of step down transformer outdoor type complete with standard fittings and accessories, HT 11 KV 3 Phase, LT 433 Volt, 3 Phase 4 wire with off load tap charger on primary side to carry secondary voltage tapping range + 7.5% with tapping at every steps 2.5% all as per IS 1180 Part –I (2014, with latest amendment No 1,2,3 & 4 of Energy Efficiency Level EEL-2) Level-2 for Transformer manufacturing of capacity 200 KVA, cooper wound, oil cooling with fins vector group : DYn 11, including initial oil filling (oil confirming to IS 335 and ISI mark ) complete all as specified including the following accessories. (a) Three Nos porcelain bushing HT 11 KV with brass bushing rods, nuts, bolts & washers etc inside cable end box. (b) One cable box LV side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG cable. (c) Oil conservation with fillers type drain valve and oil level gauge. (d) Dehydrating breather with first ill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover. (g) One No 100 mm dia, dial type having range 0 to 120 degree centigrade. (h) Rating plate and terminal marking plate. (i) Earthing arrangement. (j) Oil level gauge. (k) Oil drain filter valve.
Contd for item No. 21.10 here-in-before (l) Oil drain valve. (m) Lifting hook. (n) Oil conservator with filling hole and cap. (o) Air relief valve plug. (p) Four plate solid cast steel detachable rollers. (q) Earth bushing for neutral outside the cable box for providing independent earthing for neutral. (r) Necessary channel on foundation for fixing the transformer with joint and stopper. Note:- (i) The transformer shall be Star rating and energy conservation (Energy Conservation Binary Crops) or which necessary test certificate to be produced by contractor from manufacturer of the transformer. (ii) Pre – dispatch inspection shall be carried out by the accepting Officer. (iii) Pre- commissioning test shall be carried out by SEI/EI at site after installation of transformer. (iv) The quoted rate shall be inclusive of PCC platform made in PCC 1:3:6 type C-1 of size 2 m x 2 m x 1.2 m and also inclusive of necessary formwork, excavation and earth work for platform.
SEWAGE DISPOSAL M&L construction of RCC Septic tank 50 users capacity design to carry sewage and sludge water, excavation in any type of soil , PCC (1:4:8) below foundation , RCC M-30 Design Mix in wall, Base slab, Buffle slab and roof slab including beam etc with vent shaft, manhole opening with cover connection etc., complete with effective depth of 1.5 mtr and overall depth of 3 mtr as specified and directed .
M&L Soakage wells size 1.80m dia and 3.00m deep including excavation in any type of soil , foundation in PCC (1:3:6) wells of honey combed and solid in M-25 concrete , including intercepting chamber screen chamber Brick work in CM (1:4) RCC slab covers in M-25/RR Masonry filling with brick bats etc complete all as shown on drawings and as specified and directed .
INTERNAL ELECTRIFICATION Supply and fixing LED lights fittings 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing of LED light fittings mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED light fittings 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed.
Supply and fix metallic exhaust fan made of sturdy Engineering complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Cooper winding of sweep 230 mm sweep complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with cooper inner tank and heating element upto 2 KW capacity 25 litre, Bee 5 star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed.
M/s Gupta Construction
M/s B.Citymai Syiem
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .