Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L1 | Accepted-AOC BEING L1 BID | |
| 2 | L2₹15.4 L+₹64,755 (4.39%)Rejected-Finance VILL PO MATHUR PS RAMNAGAR DISTT SOUTH 24 PGS PIN 743368 WB | 24 PARAGANAS SOUTH | WEST BENGAL | 743368 | L2 | Rejected-Finance BEING HIGHER THAN L1BID | |
| 3 | L3₹17.6 L+₹2.9 L (19.5%)Rejected-Finance 41 BIDHANGARH SOUTH KOLKATA 700066 | KOLKATA | KOLKATA | WEST BENGAL | 700066 | L3 | Rejected-Finance BEING HIGHER THAN L1BID | |
| 4 | L4₹19.1 L+₹4.3 L (29.2%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L4 | Rejected-Finance BEING HIGHER THAN L1BID |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
19 Nov 2022, 6:00 pmClosed
GE (I) (CGN) KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
PROVN OF ACS FOR SERVICE ROOM AND OTHER MISC E/M WORK AND SEWER LINE, SEPTIC TANK AT NCB AND SSB SAILORS MD ACCN INCLUDING CERTAIN MISC WORK FOR SENTRY POST AT VARIOUS LOCATION AT SSB (KOL) DIAMOND HARBOUR UNDER GE (I) (CGN) KOLKATA
2022_MES_541011_2
8025/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (CGN) KOLKATA
AS PER TENDER DOCUMENT
11 documents required · 11 mandatory
₹500
GE (I) (CGN) KOLKATA
₹32,000
Yes
10 Dec 2022
31 Oct 2022
21 Nov 2022
31 Oct 2022
19 Nov 2022
5 Nov 2022
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for concrete bed to drain pipes of internal diameter 150 mm, in cement concrete M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in flooring finished even and smooth without using extra cement complete all as specified and as directed.
S&F rotatinally moulded, one piece construction, LLDPE septic tank of minimum 5500 ltr capacity, with 160 mm inlet and oulet connection complete all as specified and as directed. Note:- Excavation, PCC and brick work for foundation shall be measured and paid seperately.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half-brick thick honey-comb walling built in cement mortar 1:4 complete all as specified and as directed.
M & L for loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells, on open space complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
M & L for 150 mm internal dia salt glazed stoneware pipes, class SP1 as per IS 651: 2007 laid in trenches and jointed with cement slurry and yarn complete all as specified and as directed.
S & F UPVC bends without inspection door (any angle), 150 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
M & L for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for RCC M25 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for RCC M25 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed.
M & L for RCC M25 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for RCC M25 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M & L for RCC M25 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed
Material and labour for plastering 20 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Supplying & laying in trenches 100 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately.
Supplying & laying ductile iron specials (class K12 as per IS 9523: 2000) of any type, any radius/ angle, 100 mm nominal dia for mechanical and push on flexible joints for cast iron or ductile iron pressure pipe lines complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately.
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
M & L for flanged reflux valves of single door, swing check type (non return valves) of nominal pressure (PN 1.6) as per IS 5312 (Part 1): 2004, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
Cutting the existing cast iron/ galvanised iron pipes 150 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed.
M & L for construction of new valve chamber of size 1000 mm X 1000 mm X 1000 mm with necessary brick work (subclass B) in CM 1:6, including necessary earth work in any type of soil, PCC foundation (1:3:6) type D-2, 20 mm grade stone aggregate as in base concrete, brick work in CM 1:4 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40 mm X 40 mm X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide prime on all metal works & three coats of white wash on all plastered surfaces of valve chambers complete all as specified & directed by Engineer-in-Charge.
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
Supply & fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130V to 280V with output voltage stabilizer at 230 with accuracy ± 2.5% and capacity 1.0 KVA complete all as specified and as directed. (Make : V Guard model VWI 400 or equivalent.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate).
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 380 mm sweep, 4 pole, heavy duty with louvers, metal body, 4 Nos blades, Insulation Class A, 5 star rated as per Bureau of Energy Efficiency (BEE) including capacitor to ensure power factor more than 0.9 complete all as specified and as directed.
Supply and fix Exhaust fans 250 mm sweep, plastic body complete with motor & blades, AC, 50 Hz, single phase 230 V, 1280 rpm, with louvers, 4 Nos blades, Insulation Class A including capacitor to ensure power factor more than 0.9 complete all as specified and as directed.
S & F wall mounted fan, AC, 50 Hz, single phase, 230 V, 400 mm sweep, 1350 rpm, 4 Nos plastic blades, Insulation Class A including capacitor to ensure power factor more than 0.9 complete all as specified and directed by Engineer-in-charge.
S&F LED light, industrial type 40 W made up of the pressure die cast housing with IP 66 protection with minimum system efficiency 110 Lumen/W including iron frame suitable for hanging complete all as specified and as directed.
Supply and fix five star rating ceiling fan 1200 mm sweep complete WHITE colour with 3 blades and all required accessories for fixing/hanging Make - Havells Cat Pt No ES-50 or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 4 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
S&F battery 12 volt, 18 AH suitable for UPS opeartion complete all as specified and as directed.
S&F battery 12 volt, 150 AH suitable for UPS opeartion complete all as specified and as directed.
Supply only SMPS based DG Battery charger of capacity 12V 0-10 Amps suitable for charging battery of 12 to 200AH capacity equipped with indicator for battery charging status, ammeter, reverse polarity protection complete all as specified and as directed.
Disconnecting existing LT feeder pillar box/ LT panel board of any type and size including recovering serviceable items and reconnecting the incomming and outgoging cabe after raising the PCC foundation complete all as specified and as directed. Note: Excavation and PCC shall be measured and paid seperataly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cablfCe perpendicular to the direction of cable all as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Preparation of newly plastered surfaces on walls and applying two coats of white wash complete all as specified and as directed.
RANJIT KUMAR HALDER
SPECIAL CONCRETE AND CONSTRUCTION CO.
M/s Santosh Industrial Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .