Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.8 L+₹7,115 (0.21%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.4 L+₹1.7 L (4.87%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.4 L+₹3.7 L (10.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹38.5 L+₹3.8 L (10.9%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L5 | Rejected-Finance Other than L5 |
Tender Value
₹37.4 L
EMD Value
₹74,800
Closing Date
11 Jul 2024, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
GE/SRA/T-46/2024-25
2024_MES_664147_1
GE/SRA/T-46/2024-25
Open Tender
Miscellaneous Works
Item Rate
100 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹74,800
Yes
18 Jul 2024
5 Jul 2024
12 Jul 2024
5 Jul 2024
11 Jul 2024
6 Jul 2024
Amount
M&L for taking down indoor and outdoor unit of split air conditioner and voltage stabilizer of any size/capacity including copper pipe and connection lead and depositing in MES store yard as per direction including making good the disturbed surface to match with existing wall finish complete all as specified and as directed.
M&L for taking down ceiling fan, exhaust fan, desert cooler, water cooler, wall fan of any size/capacity and depositing in MES store yard complete all as specified and as directed.
M&L for taking down geyser of any size/capacity , water cooler any type any capacity and depositing in MES store yard including making good the disturbed surface to match with existing wall finish complete all as specified and as directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase automatic inbuilt stabilizer having 40/80 Litre storage and nominal cooling capacity. Insulation must be PUF type, Noise level as per IS 1391 (Part-2) latest. Refrigerant should be CFC free environment friendly R-134a/32, compressor should be hermetic type with suction gas cooled motor, equipped with overload protector, condenser should be propeller type (quiet) automatically control temperature thermostat water supply should be 3m to 12 m head with all necessary fittings GI/PVC as required at site for connection complete all as specified and directed. (MAKE- BLUE STAR, SDLX4080B / USHA, SS4080 90 L or equivalent model in GODREJ / HITACHI)
S&F desert cooler, floor mounted with castors, with 5 blades, polypropylene/PVC body honeycomb type cooling media, 90 Litre or higher water tank capacity, 3 speed, minimum 3500M3/ Hr air flow, minimum 30 feet air throw, copper wounded motor 220 V, 50 HZ and 1400 rpm complete all as specified and directed. (Make- Orient Snow breeze Pro 90 L / Bajaj DMH 90 Neo Air Cooler / Crompton Gale DAC90 or equivalent model in Havells / Symphony)
Supply, installation, testing and commissioning of wall mounted air cooled, split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated, ISEER as per bureau of energy efficiency specifications >3.82, cooling capacity should be more or equal to 2200 watt, Refrigerant environmental friendly R-32, condenser type copper ( grooved), Compressor- Rotary type, supply 220 V, copper pipe should be min 20 feet in length which has to be installed with machine. All accessories which shall be required to install the AC (including MS angle stand, Minimum 5 metre drain pipe, digital remote with battery). Additional feature should be Automatic Humidity Control, Corrosion Resistance Coating, dust filter, turbo mode, Green Anti Bacterial Eva Coils, anti bacteria filter and colour of AC should be in milky/off White Only. Cooling Capacity must be minimum 18000 BTU/hr. The supplier shall be liable for warranty for minimum period of 12 months for AC and 5 years for compressor complete all as specified as under:- Outdoor Unit :- It shall be fitted on platform with suitable powder coated brackets/ stand with vibration damping pads. Indoor unit :- It shall have cordless remote control unit, standard air filter the unit shall be wall mounted with necessary supports.
NOTES TO ITEM NO 06:- 1) Contractor shall ensure that the proposed AC complied with the above specifications. Necessary documents shall be submitted by contractor along with his letter for approval of make of AC. 2) The indoor/ outdoor unit shall be incorporated with standard sized copper piping covered with tubular vidoflex type thermal insulation fixed firmly by clamping and supporting. A suitable size PVC drain pipe shall be run from the indoor unit to the nearest drain point with U trap at the end which should be fixed firmly by clamping & supporting wherever required. Additional length of pipes & thermal insulation foam (apart from the standard length supplied by manufacturer along with AC) shall be measured and paid separately. 2) Entire refrigerant pipe shall be covered with suitable sized PVC pipe / tray with necessary bends, collars etc and it shall be neatly clamped and supported as required. 3) Necessary opening shall be made in the wall for taking refrigerant line outside and it will be finished with cement / plastering as required on ground. 4) Notwithstanding the schedule of qualification of qualities all items of interrelated work considered necessary to execute and complete the work are deemed to be included shall be provided by contractor at no extra cost.
Supply and Hanging, ceiling fan, with brushless DC motor, 1200 mm sweep with down rod, canopy, fan blades and accessories and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.0 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan complete all as specified and directed. (MAKE : USHA, Model: ENERGIA 32 / CROMPTON GREAVES, Model : ENERGION HS / ORIENT, Model: ECOTECH / PANASONIC, Model: BLDC F-12XDA / HAVELLS, Model: Efficiencia Neo)
S&F exhaust fan 300 mm sweep, 1300 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, with louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as specified and directed. (MAKE : HAVELLS, Model: Ventil Air DS / CROMPTON, Model: Transair / USHA, Model: Aero Clean Plus or equivalent model in BAJAJ / ALMONARD / ORIENT)
S&F exhaust fan 380 mm sweep, 900 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, with louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as specified and directed. (MAKE : HAVELLS, Model: Turbo Force / CROMPTON, Model: EXHD380-6-1 / USHA, Model: Turbo Heavy Duty or equivalent model in BAJAJ / ALMONARD / ORIENT)
Supply, installation, testing and commissioning of heater water storage type electric geyser (vertical cylindrical type) 25 litres capacity with BEE 5 star rating (min) and ABS body, glass lined/titanium enamel coated inner tank incl fixing arrangement, clamps, nuts & bolts etc along with providing suitable capacity flexible cable 3 core with 3 pin plug of 16 amps and stainless steel connection pipes of adequate length complete all as specified and directed. (MAKE: RACOLD, Model - CDR DLX / AO SMITH, Model - ELEGANCE PRIME / HAVELLS, Model: FABIA / BAJAJ, Model: CALDIA) NOTE: Cost of cable, plug top and SS connection pipes shall be deemed to be included in the quoted rate.
Supplying, assembling and fixing modular AC power unit comprising of 01 No 20 Amps socket and 01 No 32 Amps SP Mini MCB, 3 modules along with GI metallic flush box, cover plate and frame duly concealed in wall incl dismantling of existing unsv power unit and making good surfaces with white cement/putty complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of MCB, socket, GI flush box, cover plate & frame. Concealed conduit wiring shall be measured separately.
S&F in repairs 32 Amps modular motor starter with cover plate & frame, 2 modules along with GI metallic flush box duly concealed in wall complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box along with starter. Concealed conduit wiring shall be measured separately.
S&F in repair Metal clad socket, 20 Amps, 2 pin in different locations/bldgs complete all as specified and directed. (Make : L&T, Cat No - MPS220S or equivalent model in HAGER / HAVELLS / INDO ASIAN / C&S)
S&F in repair Metal clad plug, 2 pin, 20 Amps complete all as specified and directed. (Make : L&T, Cat No: MPS220P or equivalent model in HAGER / HAVELLS / INDO ASIAN / C&S)
S&F in repairs suction/discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR/2 TR capacity all as specified and directed. (NOTE: This item shall be executed only in case of extra length required form the standard length provided with AC)
S&F in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with fixed to Wall with necessary Mild Steel Clamps, Screws, etc. complete all as specified and directed. (NOTE: This item shall be executed only in case of extra length required form the standard length provided with AC)
S&F Insulation Sleeve type of Best quality for Copper Tubing for copper Pipe/Foam insulation for copper tubing of size up to 3/8'' dia complete all as specified and directed.
S&F PVC insulated flexible cable with 3 Core 10 Sqmm multistranded copper conductor for extension of connection of ACs as per site requirement complete all as specified and directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5%, 4-6 Sec initial delay and of capacity 5 KVA/30 A complete all as specified and directed.
Supply, installing, testing and commissioning of centrifugal monoblock pump set of 20 HP/15 KW capacity comprising of pump and motor directly coupled on a common base plate with 2900 RPM squirrel cage induction motor, TEFC type capable of delivering min 30.4 litres per second of water at a head of 28 metres suitable for operation on 415 Volts + 10%, 50 Hz AC supply including mounting the same on cement concrete or MS channel foundation incl dismantling existing BER Pump and depositing in MES Store yard complete all as specified and directed. (MAKE : KIRLOSKAR, MODEL : KDS 2050+ or equivalent model in KSB / CROMPTON GREAVES) (NOTE : Quoted rate shall be deemed to be inclusive of the cost of PCC foundation and/or MS channel required for installation of the pump set )
Supplying, lowering, fixing, commissioning and testing submersible pumping set in bore well, electrically driven, 415 volts three phase, AC, 25 HP, 18.5 KW having a discharge capacity of 700 litres per minute at a head of 118 metres, 10 stage, delivery 80 mm dia incl dismantling existing BER Pump and depositing in MES Store yard complete all as specified and directed. (MAKE: KIRLOSKAR, Model : KS8D-2510 or equivalent model in or equivalent model in KSB / CROMPTON GREAVES) (NOTE : Quoted rate shall be deemed to be inclusive of the cost of nuts, bolts & washers and any other minor parts required for proper installation of pump set)
Supply, installation, testing and commissioning of chlorine dozing system suitable to inject solution up to 28 LPH with self priming high pressure single head gear motorated adjustable liquid chlorine dosing pump, 0.5 HP, 1440 RPM, 415 V 50 Hz with combined gear & motor assembly, Starter Control Panel, FRP coated stainless steel blade agitator incl all other accessories such as lead tubing, nuts, injector, nozzle, check valve, non-return valve etc with and including connected to 150 ltr PE/FRP tank with lead, level gauge and agitator mounted on tank including dismantling of existing dosing system complete all as specified and directed.
S&F in repair Fully automatic Star Delta Starter in Sheet-Steel Enclosure Type ML 1.5 FASD, relay range 20-32 Amps, 440V, 50Hz, 3Ph incl necessary incoming & outgoing electrical connections, copper lugs, etc., complete all as specified and directed. (Make : L&T, Cat No. SS91855POEO or equivalent model in other makes specified in tender)
S&F in repair fully automatic star delta submersible pump starter with single phase preventer, in sheet steel enclosure, 3 phase, 380 volts, relay range (30-50 A), mounted on 50 x 6 mm flat iron clamp duly grouted in wall (minimum clearance 2" from wall) including necessary connections with lugs, testing complete all as specified and directed. (MAKE : L&T, Cat No: CS96008COGO or equivalent model in other makes specified in tender)
M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm along with one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC conduit (medium grade) of suitable size, including taking down of old Sub main wiring any type including batten/ conduit/casing at any indicated situation complete all as specified and directed. (NOTE : (1) Three runs of single core 10.0 sqmm cable & one run of PVC conduit shall be measured as one unit. (2) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage. (3) On completion of the wiring work, the contractor shall fill and finish the chases with cement mortar 1:6, apply 2 mm thick wall putty for smooth finish and finish with two coats of acrylic distemper as per existing shade over the conduit layout. Rate quoted by the contractor shall be deemed to include for the above aspect and no claim shall be entertained at a later stage.
-ditto- but sub-main wiring with two runs of 6sqmm main wire and 6 sqmm earth continuity wire
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing complete including taking down existing old cable of the following sizes and cross sectional area :-
16 Sqmm, 4 core
25 Sqmm, 3.5 core
S&F in repairs PVC insulated unsheathed cable with single core 10 sqmm multistranded Copper conductor, duly fixed on walls, floor etc, jointing and testing complete all as specified and directed.
Supply and Laying, 50 mm bore, low density polyethylene pipes (LDPE) of pressure rating 6 kg/ cm2 laid in trenches or fixed to poles/Walls etc, for cable protection including taking down existing old pipe complete all as directed and specified.
S&F in repairs Polypropylene Flexible Conduits, 50 mm OD, fixed to Walls etc with necessary clamps and fittings, glands etc for cable protection complete all as directed and specified.
Supplying and fixing PVC insulated and sheathed, flat submersible flat cable with stranded copper conductor, conforming to IS:694, of size 3 core 10 sq mm, 1100 volts grade including lugs and fixed to submersible pump set including taking down existing old cable complete all as directed and specified.
GENERAL NOTES:- 1) All dismantled/taken down items, except those catered under Schedule of Credit, shall be deposited in MES Store yard by the contractor under his own arrangement. Quoted rate shall be deemed to include for the ibid aspect. 2) Contractor shall submit original purchase vouchers along with manufacturer's test certificate, warranty etc for all the items supplied under the subject contract.
AMBIKA ENTERPRISES
M/S GOYAL CONSTRUCTIONS
PRINCE CONSTRUCTION
BHATIA ENTERPRISES
M/s Devendera construction
S K BUILDERS
shiv shanker enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .