| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.0 L+₹1.8 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Higher rate to the contractor |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
11 Nov 2021, 5:00 pmClosed
Executive Engineer (OS)
CCS HAU, Hisar
Establishment of Facilitation Centre of Farm Machinery Testing Centre at RRS, Uchani (Karnal)(i.e. construction of shed of size 52 feet 0 inch x 25 feet 0 inch, conversion of existing store into office room, renovation of one room and two toilets.
2021_HRY_194617_1
3261-C
Open Tender
Civil Works
Works
120 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹23,000
Yes
10 Jan 2022
3 Nov 2021
15 Nov 2021
3 Nov 2021
11 Nov 2021
3 Nov 2021
Amount
Civil work 1 to 42:- Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil (HSR 4.4.1)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar (HSR 5.7.4)
Demolishing cement concrete manually/ by mechanical means direction of Engineer - in - charge. Nominal concrete 1 :2:4 or leaner mix (i/c equivalent cum design mix) (HSR 5.23.2)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge (HSR 5.25)
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 sqm mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead). (HSR 5.45)
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. (HSR 5.48)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size) (HSR 6.1.2)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). All works up to plinth level. (HSR 6.25.1)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (HSR 6.30.1)
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts Extra for shuttering in circular work (20% of respective centering and shuttering items) {HSR 6.30.6 + HSR 6.30.14}
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in Cement Mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.20.2)
Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level. Cement mortar 1 :4 ( 1 cement :4 coarse sand) (HSR 7 .28.2)
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqmimpregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete With residual type petroleum bitumen of grade VG -1 O (HSR 9.10.1)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (HSR 9.11.1)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 (HSR 10.7)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58)
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1 :4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. (HSR 10.61)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)
Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.5.3)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)
Pointing on tile brick work with cement mortar 1 :3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing(HSR 11.26.1)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work (HSR 11.65.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (HSR 11.68.3)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied@ 3.84 kg/10 sqm) (HSR 11.93.1)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (HSR 12.36.1)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) (HSR 12.157.1.2)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Powder coated aluminium (minimum thickness of powder coating 50 micron (HSR 12.157.2.2 )
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (HSR 12.159.2 )
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (HSR 13.30.1)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (HSR 30.21)
Earth filling under floors with dune sand (tiba sand), brought from out side (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete (NS)
Providing and fixing 0.60 mm thick high strength galvanized colour coated steel sheets having trapezoidal profiles of approved make (I.S.I. mark) in roofing, at all height, fixed in position with self drilling screws of approved shape and make, complete in all respects as per drawing & manufacture’s specifications and instruction of Engineer-in-Charge. (NS)
Public health work 43 to 76:- Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. exceeding 80 mm metre (HSR 4.16.1.2)
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 sqm mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead). (HSR 5.45)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.60)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.62)
Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
15 mm cement plaster on rough side of single or half brick wall of mix: 1 :6 (1 cement: 6 coarse sand) (HSR 11.9.2)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (HSR 12.36.1)
Labour for laying, jointing, fixing and testing G.1./P.V.C./W.I. pipelines and special tees, bends, sockets, elbow etc. inside building and testing etc. complete including cutting threading Including cost ofspecials 15 mm internal diametre of pipeline (HSR 20.20.2.1)
20 mm internal diametre of pipeline (HSR 20.20.2.2)
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 20 mm internal diameter (HSR 20.23.2)
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 11.43 cm thick wall (HSR 20.26.1)
22.86 cm thick wall (HSR 20.26.2)
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repainting, replastering, replacing bitumen and colour or white washing where required 75 mm thickness of roof or floor (HSR 20.28.1)
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works 20 mm internal diametre (HSR 20.31.2)
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site (HSR 20.36)
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benchingb 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) (HSR 21.84.2)
Providing salt glazed stone ware pipes grade 'A' in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. (HSR 21.94.2) 150mm i/d
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia (HSR 22.14.1.2)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (HSR 22.14.2.1)
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISi marked white solid plastic seat and lid (HSR 22.23.1 )
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.1)
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms (HSR 22.127)
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (HSR 22.209)
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 110 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.2)
90 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.3)
Supply and fixing of GI pipe 'B' Class ISI Marked Ravindra/Jindal/Parkash(Surya) Make. (NS) 15 mm i/dia
20 mm i/dia
Supply of G.I. Union couplings of Unik /Unco make.(NS) (a) 20 mm internal dia
Supply of gun metal peet valves(heavy type) ISI marked of Leader/ DRP make. (NS) (a) 20 mm internal dia
Electrical work 77 to 113:- COPPER WIRING IN MS CONDUIT (SURFACE/RECESS ) Wiring for Light/Fan/Call Bell Point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. (HSR 23.1.1.2) Group B
Wiring in MS conduit system for 3- pin 15 amp. Plug point by using 2 no. 4 sqmm FRLS copper wire and 1 no. 4 sqmm FRLS copper wire for earthing, including providing 1 no. 15/16 Amp 3/6 pin socket and 1 no. 15/16 Amp switch required. (HSR 23.1.5.2) Group B
Wiring in MS conduit system for 3-pin Samp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required. (HSR 23.2.4.2) Group B
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required. (HSR 23.2.5.2) Group B
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS PIPE. Wiring for Light/Fan/call bell point with modular type switch/socket and GIbox, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. (HSR 23.2.11.2) Group B
COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. (HSR 23.5.1.2) Group B
Wiring in existing conduit and MS Box for 3- pin 5 amp. Plug point by using 2 no. 1.5 sqmm FRLS copper wire and 1 no. 1.5 sqmm FRLS copper wire for earthing , including providing 1 no. 5/6 Amp 3/5 pin socket and 1 no. 5/6 Amp switch required. (HSR 23.5.4.2) Group B
Wiring in existing conduit and MS Box for 3- pin 15 amp. Plug point by using 2 no. 4 sqmm FRLS copper wire and 1 no. 4 sqmm FRLS copper wire for earthing , including providing 1 no. 15/16 Amp 3/6 pin socket and 1 no. 15/16 Amp switch required. (HSR 23.5.5.2) Group B
MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (HSR 23.6.6.1) MS Pipe of 20 mm dia.
MS pipe of 25 mm dia. (HSR 23.6.6.2)
S/E of Fittings and Accessories. Providing and fixing Piano type accessories of approved make in existing Rate box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Switch 5 amp. on existing sheet. (HSR 23.8.1.1)
Wall socket 5 amp on existing sheet. (HSR 23.8.1.2)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11.1) 5 amp 1 way switch
15 amp 1 way switch (HSR 23.8.11.3)
5 amp Socket (HSR 23.8.11.4)
15 amp 6 pin Socket (HSR 23.8.11.5)
MCCB ,DISTRIBUTION BOARDS, MCB’s, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA (HSR 23.22.1.3)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- (HSR 23.22.5.1) SP MCB 6-32 AMP
SPN MCB 6-32 AMP (HSR 23.22.5.3)
DISMANTLING Dismantling old wiring points (not recessed) including necessary reparis to wall etc. (HSR 23.25.1.1) Light, fan or call bell point
Wall scoket point (HSR 23.25.1.2)
Dismantling old wiring points ( recessed wiring or partly recess, partly surface system,recess conduit and box not to be dismantled ) including necessary reparis to wall etc. (HSR 23.25.2.1) Light, fan or call bell point
Wall scoket point (HSR 23.25.2.2)
EARTHING AND LIGHTINING ARRESTOR Earthing with G.I earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required. (HSR 24.1.1)
Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2)
Pdg and laying earth connections from earth electrode with 4.00 mm dia G.I wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)
Pdg and fixing 4.00 mm dia G.I. wire on surface or in recess for loop earthing as required. (HSR 24.1.13)
STREET LIGHT Supply and erection of 32 mm dia meter 1.5 m long bracket ( B-Class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of G.I. bracket on wall with 2 Nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts an nuts etc. including necessary connections. (HSR 24.4.3)
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe. (NS) ( Size 1.5 sqmm(3/0.81mm)
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe. (NS) (Size 4 sqmm(7/0.85mm)
Supply installation testingan commissioning of wall free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet required hardware 3 mm thick bakelite sheet providing all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/Red oxide primer followed by 2 coats of powder cating in grey or required shade after rinsing. the panle having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/ switch wear.Transparent arcylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra tiems side walls and cable alley compartments shall be haiving bolted type doors with detachable extension type strcture. the panel will be complete with control wiring ( copper) and fuse protection ( only outer area on all sides shall be measured ). (NS)
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat srinkable PVC insulation complete in all respect. (NS)
S/E of AC ceiling fan capacitor type complete with shackle 5 star rating, 300mm down rod etc. (NS) i) 1200mm sweep. Make: Usha, Orient, Crompton
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. (NS) i) 1400mm sweep. Make: Usha, Orient, Crompton
S/E of LED tube rod < 20watt double side connections with 4 feet long housing made of CRCA sheet steel with epoxy powder coated white after phosphochromate treatment and 2 nos. lamps push fit type white polycarbonate holders and reflector made of white powder coated CRCA sheet total system lumen of 20watt LED should be >2200 or above in cool day light ( 5700K to 6500K ) PF > 0.95 , CRI >80 , Avg. life >50000 hours complete with mounting bracket and accessories as required with connections. (NS) Make:- Philiphs , Havells , wipro , Bajaj
S/E of flood light LED of system voltage ≤ 50 W IP 66 Multiple LED with lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen of ≤ 50 watt LED should be 5000 or above in cool day light (5700K), Lumen efficacy > 100 lm/W, Power factor ≥ 0.95, CRI ≥70, Average life ≥50000 hours, complete with all acessories as required with connections. (NS) Make Havells , Bajaj , Philiphs.
The Shri Ram Coop. Society Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .