| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 47 HANDWARA HANDWARA HANDWARA BUDGAM JAMMU KASHMIR 191111 | BUDGAM | JAMMU AND KASHMIR | 191111 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.3 L
EMD Value
₹14,700
Closing Date
14 Feb 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical SKIMS
SKIMS Soura
Electrification which includes providing and fixing of LED luminaries fans cabling and safety devices etc in newly constructed 1st floor over existing extended area of Radiology department at SKIMS CH Bemina.
2022_SKIMS_159044_1
eNIT NO.SIMS/HEE/E/ET/43 of 2021-22 Dt. 01-02-2022
Open Tender
Electrical Works
Item Rate
30 days
SKIMS MCH Bemina
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
As Described in SBD
₹14,700
Yes
16 Mar 2022
2 Feb 2022
15 Feb 2022
2 Feb 2022
14 Feb 2022
2 Feb 2022
270 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire for 16 amps points.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire for 16 amps socket outlet & AC point.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire for light points cicuit.
4 X 4 sq. mm + 2 X 4 sq. mm earth wirefor 16A points, AC points 20A socket out let.
4 X 6 sq. mm + 2 X 6 sq. mm earth wire for 3 phase netural circuit
4 X 16 sq. mm + 2 X 6 sq. mm earth wire from Busbar to DB'S. (TPNE Circuit 02 Nos)
4 X 10 sq. mm + 2 X 6 sq. mm earth wire for UPS 02 circuit
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Providing & fixing of LED 4feet long batten 6000/6500k Light having extruded aluminium body with anti-glare diffuser with energy efficient electronic driver CRI ≥ 80 with minimum sytem lumens 2000 and maximum wattage 20 , IP 20 , surge proctection 2KV or more including connection with multistrand copper conductor 3 core cable etc as required at sitewith burning hours greater than 50000 Hours.
Providing & fixing of LED 2feet long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI ≥ 80 with minimum sytem lumens 1000 and maximum wattage 15, IP 20 , surge protection 2KV or more including connection with multistrand copper conductor 3core cable etc as required at site with burning hours greater than 50000 Hours.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, Ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019),THD less than 10% and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
P/f of fan hooks of various types S type, U type, J type.
providing and fixing of Fan regulater stepped type completed as required.
Supply installation testing and commissioning of 250 mm Bird guard to pretect fan in running condition ,Double ball bearing with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts Air delivery 1600 Mhr/min
Making of holes for installing of exhaust fans and P/F of wooden frames of 12" sizes. Complete with civil work in all respects.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
SITC of Electric Heater / Geyser of capacities as mentioned below with following parameters . 1.Energy saving. 5 Star Certification by BEE 2. Provision of Temperature regulation by means of external Knob 3. Power Rating:- 220/ 230V, 50 Hz, Single Phase. 4. Maximum Rated Pressure.= 8 bar 5. Installation Type Vertical / Horizontal mounted as per site requirement 6. Body Type:- Rust, water proof and Shock Proof outer body with attractive looks and corrosion resistant inner tank made of cold rolled steel ,resistant to hard water. 7. Element Type:- glass coated heating element to prevent from corrosion and hard water. 8.Safety Valve maximum pressure =8 bar maximum 9. Energy efficiency feature:- Should have high density PUF insulation for energy Saving 10. Anti syphon system to prevent back flow of water. 11. Should have Indicating Lamps for ON & CUTT OFF. 12. Confirming to :IS 2082:2018 , IS 302-1, IS 302-2-21
35 litre (2KW)
50 litre (2KW)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) for UPS power supply.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing following rating, four pole, 415 V, isolator in the above MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A rating, double pole, 240 V, isolator in the above UPS MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the above MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing rating 200 A and breaking capacity 36 KA and FP MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in new MCB enclosure , making connections, etc. as required.
Providing and fixing of MCCB Enclosure made of sheet steel for above MCCB 200 amps complete with gland holes hinged/gasketted /lockable door and powder coated painted. Complete in all respects at siter.
P/f of bus bar chamber 200 a 8 ways (of appropriate size) TPN factory fabricated complete with lockable, hinged type door with Almunium busbar earthing nut bolt and painting powder coated, Heavy Duty
Providing and laying of spans of 3 ½ core/2 core XLPE Al. cable Armored of 120 sq.mm fresh ones. 1.1KV from Radiology power control room up to sub DB.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 120 size on wall (clamped with 25/40x3mm MS flat clamp)
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 120 sq. mm 3.5 core size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply, installation, testing and commisioning of fresh LED flood light to be fixed on wall of building as per following specification. 1. Input voltage : 150 V to 270 V 2.Lumens : Min 6500 3. Power factor : >0.90 4. Life expecting : more than 40,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 70-80W 7. Luminous flux : 10000 to 11500 lumens 8. Colour Temperature : 5,500 to 6,500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 80 12. Working Temperature : 0 deg to 50 deg 13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture
M/s KASH ENGINEERS AND ASSOCIATES
M/S BHAT SYNDICATE
M/s BILAL ELECTRIC GOODS
I S F Engineers Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .