Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 CrAccepted-AOC | ₹1.9 Cr Quoted ₹2.0 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 1₹2.1 CrRejected-Finance 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹2.1 Cr | 1 | Rejected-Finance Since not L1 |
| 3 | 3₹2.1 CrRejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | ₹2.1 Cr | 3 | Rejected-Finance Since not L1 |
| 4 | 4₹2.2 CrRejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | ₹2.2 Cr | 4 | Rejected-Finance Since not L1 |
| 5 | 5₹2.2 CrRejected-Finance | ₹2.2 Cr | 5 | Rejected-Finance Since not L1 |
Tender Value
₹2.3 Cr
EMD Value
₹3 L
Closing Date
1 Apr 2022, 4:00 pmClosed
CE RnD Secunderabad
CE RnD Opp JBS Picket Secunderabad
URGENT REPAIR AND ADDITION/ALTERATION IN CCC PROCESS BUILDING NO. 184-A AT HEMRL PUNE
2022_MES_505909_2
CA NO. CERD/PSN/TOKEN/31 OF 2021-2022
Open Tender
Civil Works
Item Rate
365 days
GE I RnD Pashan Pune
As per NIT
9 documents required · 9 mandatory
₹2,000
GE I RnD Pashan
₹3 L
Yes
25 May 2022
11 Mar 2022
11 Apr 2022
11 Mar 2022
1 Apr 2022
18 Mar 2022
Amount
Taking down chowkhats including shutters (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4 sqm each complete all as specified and directed.
Taking down chowkhats including shutters (without taking off shutters from the frame) n. exc 1.5 sqm each complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, build in cement lime mortar or cement mortar including all quoins, arches, pillars etc., but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) 100mm thick as in floors complete all as specified and directed.
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' of slab 100mm thick complete all as specified and directed.
Plain cement concrete (1:2:4), type B0 (using 12.5mm graded stone aggregate) 40mm thick complete all as specified and directed.
Plain cement concrete (1:2:4), type B0 (using 12.5mm graded stone aggregate) 100mm thick complete all as specified and directed.
Screed bed15mm thick in cement mortar (1:4) for laying floor finishes complete all as specified and directed.
10mm thick backing coat in cement mortar (1:3) on brick or concrete surfaces for fixing of wall tiles as in dado / skirting complete all as specified and directed.
Acid resistant tiles conforming to IS - 4457:2007, not less than 15mm thick of size not exc. 0.36 sqm, viterous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, as in floors etc., complete all as specified and directed.
Acid resistant tiles conforming to IS - 4457:2007, not less than 15mm thick of size not exc. 0.36 sqm, viterous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, as in skirting / dado, complete all as specified and directed. Make for Sl Item Nos. 12 & 13: - Endura by HR Jhonson or techno commercially equivalent in Regency / Kajaria / Somany
Non-skid coloured ceramic tiles 7 to 8mm thick, dark shade (square / rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Glazed, coloured (including desiner tiles as approved by GE) ceramic tiles in verticle surface of size 300 x 450 x 7 to 8mm thick, set and joined in neat cement slurry and pointed in cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Providing and applying 3 to 3.5mm thick, anti-static, self smoothening flooring on concrete surface having moisture content less than 5%, Electrical resistance of floor surface to earth between 50 Kilo Ohms to 2 Mega Ohms measured with wet electrode. Surface preparation includes grinding of concrete surface, proper cleaning, removing of loose mortar, paint residuals, curing compound residues and existing joints shall be open & joint edges shall be repaired by Epoxy putty followed by application of NITOPRIME 25- Epoxy Resin Based Primer for concrete surface using brush or Rooller and allow curing for 8-10 hours (Depending upon Temperature). Mixing of base, hardner, and filler components of NITOFLOOR EU5- High stength sel smoothening Epoxy underlay using slow speed Drill and poured on prepared surface at 1.5mm DFT all as specified over copper strip grid work made out of using 25mmx0.5mm thick. copper strips forming One Square Metre grid jointly of surface by pasting suitable adhesive and connect the same to earthing point complete all as specified and directed.
Dismantling water tanks and removing to store of capacity 1000 litres complete all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoised and fixed in position all as specified in SSR Part-I of capacity 1000 litres complete all as specified and directed.
Dismantling of AC / CI / PVC down take pipe 150mm bore complete all as specified and directed.
PVC (SWR) pipes, 110 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
PVC (SWR) bends any radius shoe, socket etc., 110mm bore complete all as specified and directed.
PVC (SWR) branch piece, single `Y’ equal or unequal, 110mm bore complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed.
Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) of FE 290 gde E165 including distance pieces, cleats etc., complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of FE 290 gde E165 complete all as specified and directed.
Dismantling of asbestos cement (corrugated ted, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Factory made box type steel windows, shop coated, glazing with sheet glass including cutting holes 04 Nos for each window for hold fasts, 150x230x75mm, PCC (1:2:4) type B1 (using 20mm graded stone aggregate) for fixing hold fasts including necessary form work, complete all as shown in drawing No. CERD / TD-485 / 2021, Sheet Nos. 1/5 to 5/5 complete all as directed. Notes: (i) Glass panes & painting shall be measured and paid separately under respective items of BOQ. (ii) Hold fasts 150mm long made out of 25x6mm flat iron made to shape-04 Nos per Window. (Each side-02 Nos)
Factory made box type steel ventilators, primer coated, glazing with wired glass, complete all as shown in drawing No. CERD / TD-485 / 2021, Sheet Nos. 1/5 to 5/5 complete all as directed. Notes: - (i) Glass panes and painting shall be measured and paid separately under respective items. (ii) Hold fasts 150mm long made out of 25x6mm flat iron made to shape-04 Nos per Window. (Each side-02 Nos)
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads exc 1.50 sqm complete all as specified and directed.
Rough cast wired glass, 6.4mm thick and glazing with oil putty in square not exc 0.5 sqm each complete all as specified and directed.
Taking down rolling shutter any type complete all as specified and directed.
Steel rolling shutters, 1.00mm thick lath, gear operated type without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated complete: but gear operated type with chain wheel and hand chain complete all as specified and directed.
Safety lever locks, mild steel with 4 levers for rolling shutters complete all as specified and directed.
Ball bearing for rolling shutters complete all as specified and directed.
Taking down collapsible gate any type complete all as specified and directed.
Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed.
Factory made, solid PVC door frame of size 50mm x 47mm made out of 5 mm colour PVC sheet single side prelam PVC Sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with MS Square tube all as specified and directed.
Factory Made Solid PVC Moulded Door Shutters with particle board core 28 to 30 mm thick (tile:), with 2, 4 or 6 raised panel design with 5mm thick Moulded PVC Sheet on the front Face & 5mm Prelam / plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
Aluminium handles, extruded type, anodised of size 150mm complete all as specified and directed.
Mild steel butt hinges, 100mm size, bright finish stainless steel with galvanised mild steel hinge pin complete all as specified and directed.
Aluminum barrel tower bolt, 150 mm long with barrel of extruded section and rolled or cast bolts and fixed complete all as specified and directed.
Wash hand basin, vitreous china, oval shaped, first quality, ivory colour, of size 560mm x 450mm x 175mm, including cutting for and pinning in ends of brackets or erecting stand, with and including CI brackets, PVC flexible pipe with both side brass nuts to joint and 750mm long PVC waste pipe 32mm dia, CP waste coupling with long screwed shanks and fly nuts, fixed in repairs, complete all as specified and directed.
Tubular towel rail 20 mm dia, 600mm long, brass chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight 190 gms) complete all as specified and directed.
Vitreous china Urinal, half stall type, white excluding flushing cistern, flush pipe and waste pipe, fixed in repairs, complete all as specified and directed.
Bib taps, long shank, fancy type, 15mm bore of pipe, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed, 15mm dia of pipe, complete all as specified and directed.
Angle stop cock, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm dia of pipe, complete all as specified and directed.
Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60gms) complete all as specified and directed.
Push cock, chromium plated, fancy type 15mm bore, fixed in repairs complete all as specified and directed.
PVC connection, 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Gun metal globe or gatevalve 20mm with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Ball brass valve of 20mm bore, high pressure with polythene float & fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Taking down cement plaster on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Rendering 15mm thick in two layers on fair faces of brick work or concrete surfaces 10mm in CM (1:6) and 5mm top layer in CM (1:4) mixed with integral water proofing compound finished as sand plaster complete all as specified and directed. Note: WPC shall be measured and paid separately.
Rendering 15mm thick in CM (1:6) on internal surfaces of brick wall finished even and smooth without using extra cement complete all as specified and directed.
5mm thick plastering in CM (1:3) on ceiling and finished even and smooth without using extra cement complete all as specified and directed.
Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of aluminium painting over a coat of aluminium red oxide primer, complete all as specified and directed.
Preparation of new steel surfaces over 10 cm width or girth applying two coats of two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Supply only fire resisting silicate paint complete all as specified and directed.
Preparation of new steel surfaces over 10cm width or girth and applying two coats of fire resistance paint over one coat of red oxide primer, except paint complete all as specified and directed.
Preparation of old steel surfaces any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Prepration of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer after preparation of surfaces at any height including necessary scafolding etc., complete all as specified and as directed.
Preparation of newly plastered surfaces of wall and applying two coats distemper oil emulsion over a coat of primer and average 3mm thick wall care putty, complete all as specified and directed.
Preparation of newly plastered ceiling surfaces of applying three coats of white wash complete all as specified and directed.
Structural steel work as in stairs (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets, etc., conforming to Fe 410-W (Gde E-250) quality 'A', complete all as specified and directed.
Structural steel work as in joist, channel, angle, or tee sections, fixed independently, without connection plate,as in fencing post etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W (Gde E-250) quality 'A', complete all as specified and directed.
Structural steel work as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment, conforming to Fe 410-W (GdeE-250) quality 'A' complete all as specified and directed.
Demolition of bricks (laid flat or on edge) or brick tiles / cement concrete in floors, channels, kerbs, aprons etc., laid bedded and pointed in any mortar complete all as specified and directed.
PCC (1:2:4), type B0 (using 12.5mm graded stone aggregates), average thickness 40mm as in levelling course / padding / coping on roof / sunken slab or chajjas etc to level the undulations of roof or to maintain the slope of roof etc, complete all as specified and directed.
PCC (1:2:4) type B0 (using 12.5mm graded aggregate) as in benching, coping, kerbs and the likes including weathering slightly rounded or chamfered angles and throating as directed including necessary use and waste of form work complete all as specified and directed.
Rendering 10mm thick in CM (1:4) on green concrete surfaces of roof slab, projections and parapets mixed with WPC complete, all as specified and directed. Note: Water proofing compound shall be measured and paid separetely.
Brushing neat cement slurry mixed with WPC at the rate of 3.0kg of cement per sq.metre complete all as specified and directed. Note: Water proofing compound shall be measured and paid separetely.
APP pre-fabricated membrane, 3mm thick, with non woven polyester matt central core of 160 gsm (min) impregnated and coated on both side layer of APP modified bitumen and finished with micro-perforated heat fusible poluthene film on both surfaces over 0.3 ltrs/Sqm bituminous primer confirming to IS-3384. The weight of APP membrane shall not less than 3.5kg / Sqm and laid over primed surface by using torch and apply uniform preserve with roller. The overlap of membrane shall be 100mm on sides and 150mm on end laps. Applying a coat of hot blown bitumen 85/25 grade @1.2Kg/Sqm over the membrane and finally applying two coats of aluminium paint @ 0.10 ltrs/Sqm as directed by Engr-in-Charge. Make: Torch shield, Asian Paints smart care APP membrane, IWL, SIkka, Forsroc Notes: (i) The work shall be executed through authorised applicator only. Approval of which shall be taken from GE before commencement of work. (ii) The contractor has to furnish guarantee for 10 years for APP membrane. (iii) Aluminium paint shall be measured and paid separetely.
Supply only aluminium paint complete all as specified and directed.
Supply only integral liquid WPC of approved make complete all as specified and directed.
Pressure guniting 25mm thick lath over existing RCC structure with CM (1:3) incorporating with approved acrylic polymer agent and 5mm thick plaster CM (1:4) for finished the gunited surfaces even and fair without using extra cement including scaffolding any height from base complete all as specified and directed. Note: Acyrlic polymer shall be measured and paid seperately under relevant items of this schedule.
Supply only Arcylic polymer agent of approved make of pressure guniting complete all as specified and directed.
Powder coated aluminium section for partition, for doors frame, windows with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. Size of Aluminium section (Jindal CAT K 2005) shall be as under: - (a) Shutter vertical - Section No 19569 & 19502 (b) Shutter Top - Section No 19571 (c) Shutter Middle - Section No 20014 (d) Shutter bottom - Section No 19352
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Reinforced cement conrete (1:2:4), type B0 (using 12.5mm graded stone aggregates) as in chajjas complete all as specified and directed.
Reinforced cement conrete (1:2:4), type B0 (using 12.5mm graded stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Taking down copper / aluminium flame proof point wiring steel conduit pipe (light, fan, socket or power) complete, including switches, sockets etc., removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc., complete all as specified and directed.
Taking down copper / aluminium flame proof sub main wiring in steel conduit pipe any type complete, including etc., removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc., complete all as specified and directed.
Taking down unservicable FLP tube light fitting / well glass fittings / Bldg security lights complete all as specified and directed.
Taking down flame proof SSC single phase / three phase complete all as directed.
Taking down underground cable any size complete all as specified and directed.
Taking down old unservicable flame proof exhaust fan carefully and depositing to the MES store complete all as specified and directed.
Taking down unserivecable flame proof DB any size complete all as specified and directed.
Taking down the broken cable tray of any size complete all as specified and directed.
PVC FRLS armoured copper cable of size 1.5 sqmm x 3 core including saddling on wall / surface complete all as specified and directed. Make: KEI / Gloster / Havells.
PVC FRLS armoured copper cable of size 2.5 sqmm x 3 core including saddling on wall / surface complete all as specified and directed. Make: KEI / Gloster / Havells.
PVC FRLS armoured copper cable of size 4 sqmm x 4 core including saddling on wall / surface complete all as specified and directed. Make: KEI / Gloster / Havells.
PVC FRLS armoured copper cable of size 6 sqmmx 4 core including saddling on wall / surface. Make:-KEI/ Gloster/ Havells
Supply and fix PVC FRLS armoured copper cable of size 10 sqmmx 4 core including saddling on wall / surface. Make:-KEI/ Gloster/ Havells
PVC FRLS armoured Copper cable of size16 sqmmx 4 core including saddling on wall / surface. Make:-KEI/ Gloster/ Havells
Flame proof switch of LM 6 body, rotary switch, SP, 16 Amps for ON / OFF light / fan point to operate on single phase 230 Volts, AC with termination box certified by CIMFR and PESO certified IS-2145 complete all as specified and directed. Make: Shyaam switch gear Cat Part No. SSPL/2C/1010 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof switch socket combination suitable for 2P+E (3 Pin) 16 Amps, 250 volts including plug and top, LM-6 body, certified by CIMFR and PESO, ISI marked all as specified and directed by Engineer-in-Charge. Make: Shyaam switch gear Cat Part No. SSPL/2C/1010 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof switch socket combination 4P+E (5 Pin) suitable for 32 Amps, 415 volts including plug and top, LM-6 body, certified by CIMFR and PESO, ISI marked all as specified and directed by Engineer-in-Charge. Make: Shyaam switch gear Cat Part No. SSPL/2C/1010 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof receptable (encloser) with MCB 32 Amps four pole complete all as specified and directed. Make: Shyaam switch gear Cat Part No. SSPL/MCDB/186 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof receptable (encloser) with MCB 63 Amps four pole complete all as specified and directed. Make: Shyaam switch gear Cat Part No SSPL/MCDB/186 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof flexible metalic hose conduit 20mm dia 300mm long for exhaust fan complete all as specified and directed. Make: Shyaam switch gear Cat Part No. SSPL/FH/145 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof 100mm dia Junction Box 4 way complete all as specified and directed. Make: Shyaam switch gear Cat Part No. SSPL/JB/105 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof / Weather proof LED 2 x 20 W tube light fitting with lumen out put not less than 4000 Lumens, body made out of cast alluminium alloy LM6 Construction certified by CIMFR and PESO, ISI marked including suitable electronic including necessary fixing arrangments and connecting up complete all as specified and directed by Engineer-in-Charge. Make: Shyaam switch gear / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof / Weather proof LED Well Glass Light Fitting suitable for 80 Watt with lumen out put not less than 8000 Lumens, body made out of aluminium alloy LM-6 body epoxy painted with wire guard relfector, flame proof Heat Resistant Clear Toughened type 'A’ with LED COB / SMD (Bridge, Cree, Citizen) including suitable electronic including necessary fixing arrangments and connecting up complete all as specified and directed by Engineer-in-Charge. Make: Shyaam switch gear Cat Part No. SSPL/1251 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof exhaust fan of size 305mm with louvers single phase 240 volt, 0.25 HP, 1440 RPM complete all as specified and directed. Make: Shyaam switch gear Cat Part No. SSPL/MT/140 / Sudhir switch gear Pvt Ltd / Baliga.
Building security road way light fitting LED Endura Pearl 40 watts new generation energy saving pressure die-cast aluminium IP 65 roadway luminaire with high power LED as light source and electronic driver including PVC three core flexible copper conductor cable from ceiling rose to connector of fittings complete all as specified and directed. Make: Havells / Crompton / Philips.
Flame proof panel board made out LM6 material and high stencil stell hinges and nuts incomer 400 Amps 50KA TPN MCCB and out going 250 Amps 25 KA MCCB TPN - 2 Nos, 63 Amps MCCB TPN 16 KA - 4 Nos complete all as Gas Gr IIA, IIB certified by CIMFR Dhanbad & CCOE (PESO) Nagpur along with ISI marking with digital multifunctional meter of size 96 x 96 mm including multiple entry junction in LM 6 of size 300 x 350 x 155 mm-03 Nos complete all as specified and directed. Make: Shyaam switch gear Cat Part No. SSPL/RCP/110 / Sudhir switch gear Pvt Ltd / Baliga.
Flame proof distribution panel board made out LM6 material and high stencil stell hinges and nuts incomer 32 Amps TPN MCB 10 kA and out going 6-32 Amps single pole MCB 10 kA-15 Nos complete all as specified and directed.
Flame proof panel board made out LM6 material and high stencil stell hinges and nuts incomer 160 Amps TPN MCCB 25 kA and out going 63 Amps MCB TP 10 kA-3 Nos and 32 Amps MCB TP 10kA-2 Nos complete all as specified and directed.
Flame proof distrubution panel board made out LM6 material and high stencil stell hinges & nuts incomer 63 Amps TPN MCB 10 kA & out going 32 Amps MCB TPN 10 kA-4 Nos and 6-32 Amps MCB SP 10 kA-6 Nos complete all as specified and directed.
Flame proof double compression gland of 3/4 inch size complete all as specified and directed.
Flame proof double compression gland of 1 inch size complete all as specified and directed.
Flame proof double compression gland of 1 ¼ inch size complete all as specified and directed.
Flame proof double compression gland of 1 1/2 inch size complete all as specified and directed.
Flame proof double compression gland of 2 inch size complete all as specified and directed.
Flame proof double compression gland of 2 1/2 inch size complete all as specified and directed.
LT UG cable XLPE aluminium 1100 Volt, 120 Sqmm x 3.5 core, passing through duct / fixing on wall complete all as specified and directed.
16 SWG HOT DIPPED GALVANISED / POWDER COATED with coupler plates cable tray size 100 x 50mm of 2 RM Each length complete all as specified and directed.
16 SWG HOT DIPPED GALVANISED / POWDER COATED with coupler plates cable tray size 150 x 75mm of 2 RM Each length complete all as specified and directed.
Taking down / dismantling all exising cable from old panel board carefully and remove old panel board, tracing incoming cable in ground excavate from ground with out any damage, clean it properly and connect cable to new panel board with new cable gland and new lugs and restore the supply to building complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth strip connected to LT panel and protected by galvanised iron or steel pipe, light grade 40mm bore and water pipe 20mm bore, medium grade with funnel and wire mesh including all necessary excavation and earth work, PCC (1:3:6) type C2 (using 40mm graded stone aggregate) chamber and CI cover all as shown in Electrical Plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including taking down old unserviceable material complete all as specified and directed.
Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit / pipe fixed to poles or any other indicated situation for loop earthing as required 32 x 6 mm size galvanised strip complete all as specified and directed.
Aluminium strip 25 x 3mm with saddle and fixing screws etc., for roof conductors and down conductors above ground level fixed on walls / roof with all neccesary fixing arrangements complete all as specified and directed by Engineer-in-Charge including dismantling taking out old aluminium strip. Note: Epoxy base insulator only will be measured and paid seperately.
Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including, 3 Nos, 8mm dia 25mm long hex, head screws, including dismantling taking out old inspection box complete all as specified and directed.
Galvanised iron strip of size 32 x 6mm burried in ground or "fixed on wall'' with all neccesary fixing arrangements complete all as specified and directed by Engineer-in-Charge including dismantling taking out old galvanised iron strip. Notes: (i) Epoxy base insulator only will be measured and paid separely. (ii) All GI strip joints should be butt welded atleast 50 mm long.
Air termination, single pointed aluminium rod of 12mm dia, 300mm long including dismantling taking out old air termination, complete all as specified and directed.
Air termination single pointed aluminium rod of 12mm dia, 1200mm long, including dismantling taking out old air termination complete all as specified and directed.
Earth pit indicator made out of MS sheet of 16 SWG of size 30x20cm welded to angle of size 25x25x3mm at a height 1M above ground including dismantling taking out old earth pit indicator complete all as specified and directed.
Epoxy base insulator suitable size 35 mm height fixed on PCC blocks / on wall on MS angle / on towers with and including nut bolts and washers etc complete all as specified and directed by Engineer-in-Charge including dismantling taking out old insulator.
Inspection boxes / Test point boxes 250x150x100 mm made out of 16 gauge MS sheet with top cover including provisioin of fixing of 2 Nos epoxy insulator with and including insulating PVC sheet for incoming and outgoing copper strip for proper insulation etc complete all as specified and directed.
PCC block of size 150 x 150 x 150mm in PCC (1:3:6) type C1 (using 20mm stone graded aggregate) including necessary form / mould for fair and even surfaces, air termination rod / GI strip etc., complete all as specified and directed by Engineer-in-Charge.
Supply and install, inverter technology split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condeser green gas with minimum 5 star rating and EER 3.2 of capacity 2 TR complete all as specified and directed by Engineer-in-Charge. Make: Voltas / Bluestar / Daikin.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed by Engineer-in-Charge. Make: V Guard / National.
Rough excavation n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
Hardcore of gauge n exc. 63 mm of broken stone or boulder deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
Cement concrete (1:4:8), type D2 (using 40mm graded stone aggregate) 100 mm thick as in sub base complete all as specified and directed.
Cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) 100 mm thick as in hardstanding complete all as specified and directed.
Excavating in trenches not exe 1.5m wide and not exc 1.5m in depth and getting out in hard / dense soil complete all as specified.
Plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in fondation, filling and mass concrete complete all as specified and directed.
Walling of random rubble masonary, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing or face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses 20 mm deep in granite or trap stone complete all as specified and directed.
Cement concrete (1:2:4), type B1, (using12.5mm graded stone aggregate) as in surface channel and drain, complete all as specified and directed.
Rendering 15mm thick in CM (1:4) on fair faces of stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc., complete all as specified and directed.
Returning, filling in, including spreading levelling watering and levelling in layers n.exc 25 cm thick in hard soil complete all as specified and directed.
Removing excavated material exc 250m and n.exc 500m and deposting where directed complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100V grade with stranded alluminium conductor of size 300 sqmm, 3.5 core, including taking down old unserviceable cable, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100V grade with stranded alluminium conductor of size 25 sqmm, 3.5 core, including taking down old unserviceable cable, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for taking out / laying of LT under ground cable and getting out in the following type of earth stata complete all as specified and directed. (a) Soft / loose soil.
(b) Soft / Disintegrated rock.
Supply and lay in trenches Un-reinforced precast concrete cable cover class LV type 2 flat size 300 x180 x 40 mm for cable protection all as specified and directed.
Sand (stone crushed sand) in cable trenches as cushioning to cables including spreading and punning down all as per clause No 3.21 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness shall only be measured and paid.
GI tube, 100 mm dia bore, light grade with all fittings, complete, fixed to walls, pole, ceiling or laid in trenches for cable protection includding removing of old unserviceable pipe of any size complete, all as specified and directed. Notes:- (i) Excavation and earth work where required shall be measured separately. (ii) MS clamps for fixing on wall / pole, etc are included in the unit rate.
Cutting of roads / plinth for removal / lalying of pipe and making good the disturbed surfaces as per existing adjoining surfaces complete all as specified and directed by Engineer-in-Charge.
PCC (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in foundations of for making good road / foot path / hard standing / drain / bldg plinth protection complete all as specified and directed.
Dismantling and taking down existing LT panel board complete all as specified and directed by Engineer-in-Charge.
(a) Incoming MCCB 4 pole 415V, 630 Amps, 50Hz with thermal magnetic release and Ics = 100% of Icu with rupturing capacity 50 KA - 01 No. (b) Outgoing MCCB 4 pole 415V, 400 Amps, 50Hz with thermal magnetic release and Ics = 100% of Icu with rupturing capacity 36KA - 01 No. (c) Outgoing MCCB 4 pole 415V, 250 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 36KA - 02 Nos. (c) Outgoing MCB SPN, 32 Amps 10 KA 'C' series 230V AC supply - 02 Nos. (d) Panel mounted type digital multifunctional energy meter A, V, Z, KW, PF CT operated, LT 3 phase, 4 wire, including ct ratio 630/5 - 01 Nos. (e) LED indicating lamps sets RYB - 01 Set. (f) Astro time switch-02 Nos.
PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in fondation, filling and mass concrete complete all as specified and directed.
Keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:3) complete all as specified and directed.
Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connection plate, as in fencing post etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed.
Mild steel angles,bars, flats etc as in supports for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc,) including all necessary drilling, bolting or riveting, etc, and similar work conforming to fe 410-0 or Fe 310-O complete all as specified and directed.
Fixing only, chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only, Chain link MS galvanised fencing, any size or type complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm & n exc 10cm long complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Steel tubing, 15mm bore, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Mild steel bolt, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed.
Preparation of new steel surfaces any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Mehta Construction Co.
SHAILENDRA B TULSANI
VIRENDRA FABRICATORS
S G Enterprises
Baljeet Singh Choudhari
SHAH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .