Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | ₹35.0 L | L1 | Accepted-AOC Accepted being lowest on 28 Nov 2020 |
| 2 | L2₹35.7 L+₹79,453.80 (2.27%)Rejected-Finance | ₹35.7 L+₹79,453.80 (2.27%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹40.3 L+₹5.3 L (15.2%)Rejected-Finance | ₹40.3 L+₹5.3 L (15.2%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹41.6 L+₹6.6 L (19.0%)Rejected-Finance 80 G T ROAD FEROZEPUR CANTT PB | ₹41.6 L+₹6.6 L (19.0%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹46.9 L+₹11.9 L (34.1%)Rejected-Finance | ₹46.9 L+₹11.9 L (34.1%) | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
18 Nov 2020, 6:00 pmClosed
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Provn of Elevated Sentry post, stone sett flooring, wall panelling, aluminium door and certain revenue/minor works under AGE B/R (P-1) at Faridkot Mil Stn
2020_MES_371286_3
GE FRD-48/2020-21
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class D Category a i
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹68,000
Yes
31 Dec 2020
28 Oct 2020
20 Nov 2020
28 Oct 2020
18 Nov 2020
4 Nov 2020
Amount
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc. 1.5 meter wide and not exc. 1.5 meter in depth in foul condition for foundation etc and getting out in soft/loose soil complete all as specified and directed by Engineer in Charge. Note : Necessary dewatering of water shall be included in the unit rate of item
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer in Charge.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, sub base & mass concrete complete all as specified and directed by Engr-In-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded stone aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc complete all as specified and directed by Engr-In-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engr-In-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed by Engr-In-Charge.
M&L for reinforced cement concrete type A-1, 1:1.5:3 using 20 mm graded crushed stone aggregate as in slab supported on walls, beams and columns in floor, roof, landings, deck slab and in shelves complete all as specified and directed by Engineer in Charge.
M&L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M & L Form work to sides of columns, pillars, posts, struts etc of square, rectangular surfaces, rough finished flat surfaces of concrete complete all as specified and directed by Engineer in Charge.
Form work to sides and soffits of floor or roof beams, beam haunching, girders, lintels, cantilevers, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed by Engineer in Charge.
M&L for use and waste of form work to soffits of suspended slabs such as floor or roof slab, landing and similar work not exceeding 200mm thick (Horizontal or slopping) for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Use and waste of form work to edges of concrete flats, slabs etc including fair finished surface complete all as specified and directed by Engr-In-Charge.
M&L for TMT bars 10mm dia and over cut to length bent to shape as required, including cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engr-In-Charge.
All as per Ser item No 15 but 6 to 8mm dia and including 10mm as in stirrups complete all as specified and directed by Engr-In-Charge.
M&L for broken brick hard core of gauge not exceeding 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge
Material and labour for providing 75 mm thick cement concrete (1:3:6) type C2 using 40mm graded aggregate as in plinth protection, foot path, drains surfaces even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L 75 mm thick cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub-floors, sub bases, floors and pavings tc complete all as specified and directed by Engr-In-Charge.
M & L 40 mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in sub-floors, sub bases, floors and pavings tc complete all as specified and directed by Engr-In-Charge.
M&L for glass dividing strips 3mm thick 38mm width in repair inserted in position complete all as specified and directed by Engineer in Charge.
Framed work such as grills, gratings,etc., with ends of bars shoulderd of bars and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe290, Gde-E-165 complete all as specified and directed by Engr-In-Charge.
Material and labour for preparation of new steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-In-Charge.
M&L for brick work with fly ash bricks of old size straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified and directed by Engr-In-Charge.
M&L for 5mm thick rough cast plaster over 10mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces rough cast mixture shall consist of crushed stone or fine gravel aggregate, coarse sand & cement in the ratio of 1:1:1 over rendering coat complete all as specified and directed by Engineer in Charge.
M & L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 5mm thick in cement mortar (1:3) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 5mm thick in cement mortar (1:3) on brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for preparation of newly rough cast plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed by Engr-In-Charge.
M & L for preparation of newly plastered /RCC surfaces of wall and applying two coats of cement base paint complete all as specified and directed by Engr-In-Charge.
M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on wall complete all as specified and directed by Engr -in - charge.
M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on ceiling complete all as specified and directed by Engr -in - charge.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet having beading/border on top and on joints inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed by Engineer-in-Charge. Note:- If any minor electric fittings and fixtures disturbed there will be match and fixed as existing.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
Taking down of chowkats or frames exc 1.5 Sqm but n exc 4 sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed by engr-in-charge.
S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating shall be 50 micron as per the specification) complete all as specified and directed by Engineer-in-Charge.
S&F powder coated coloured aluminium door shutters aluminium sections weighing 0.55 Kg/RM including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium snap beading, screws, handles 2 Nos in each door, hinges, thickness of powder coating not less than 50 micron complete all as specified and directed by Engineer-in-Charge.
S and F floor door closer hydraulically regulated, Aluminium (Diecast body), designation No 2, universal type suitable for door shutter 700mm to 850mm width and weight between 36 to 60 kg complete all as specified and directed by Engineer in Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Sqm each including cutting holes of appropriate size in brick / concrete surfaces for insertion of PCC block for hold fasts complete all as specified & directed by Engineer-in- charge.
S&F Anodised aluminium window and ventilator shutters, (powder coating of any colour), sliding type three track, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) shashes roller (if required), rubber gasket, interlocking arrangement at both sides of shutters complete all as specified and directed by Engineer-in-Charge.
S&F 4.8mm thick plain sheet / coloured glass ordinary quality and glazing with rubber bidding (supplied alongwith shutters) in square n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F 4.8mm thick plain sheet ordinary quality and glazing with rubber bidding (supplied alongwith shutters) in square n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F powder coated Aluminum Grill diamond shape of mini 5 to 6mm dia fixed on aluminium window frame by using clips, screws & snap beading complete all as specified and directed.
Demolition of cement concrete unreinforced concrete in ground floor and paving n exc 15cm thick (below or above ground level etc complete all as specified and directed by Engr-In-Charge.
M&L 25mm thick PCC 1:2:4 type B-0 (Using 12.5 mm graded aggregate), as in floor / sub floor concrete complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured (light colour as approved) tiles (non skid) of size 400x400x7-8mm thick as in flooring set and jointed in neat cement slurry mixed with pigment to match the shade of slab over and including 15mm thick screed bed in CM 1:6 including rubbing and mirror polishing complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone wall etc including raking out of joints, hacking for keys and scrubbing down with water etc and removal of debris upto a distance upto 50m complete all as specified and directed by Engr-In-Charge.
M & L Glazed ceramic tiles, coloured (light colour as approved), of size 450X300X7 mm (or size available in market as decided by engr-in-charge) thick on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engr-In-Charge.
Taking down 15mm bore steel water tubing alongwith connections in any situation complete all as specified and directed by Engineer in Charge.
M & L for cutting chases for concealed water tubing etc. and making good cutting not exc 10cm girth complete all as specified and directed by Engineer in Charge.
S&F GI tubing medium grade 15mm bore with all fittings and fixed to wall/ceiling and laid in floors complete all as specified and directed by Engr-In-Charge.
S & F Vitreous china squatting pan Orissa pattern size 580mm x 440mm white / coloured with integral foot rest including necessary lime concrete and 100mm bore CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing including flush pipe of PVC and connection to WC pan complete all as specified and directed by Engr-In-Charge. .
S&F vitreous china wash basin white, flat back of size 550x400mm including cutting for and pinning in ends of brackets or erecting stand including 32mm waste fittings & waste pipe, 15mm fancy type chromium plated pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with long screwed shanks and flynuts, screwed for iron pipe and chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement with PVC connection 15mm size, 450mm long with PTMT nuts and other end fixed complete all as specified and directed by Engineer-in-Charge.
M & L 75mm dia PVC (SWR) floor traps plain with grating including jointing with solvent cement fixed to wall / laid in trenches etc complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls, laid in trenches or in floors Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in- charge.
Supply and fix PVC low level flushing cistern white 10 litre capacity, valveless syphonic action type with float, handle including flush pipe of polythene of low or high density of PVC 32mm dia, 60cm long and bracket etc and 15mm bore PVC connection length 450mm with PTMT nuts complete all as specified and directed by Engineer-in-Charge.
Takind down and refixing vitreous china bowl half urinal complete all as specified and directed by Engr-In-Charge.
S &F Vitrified ceramic tiles light shade 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry over & including 15 mm thick screed in cement mortar (1:4) and pointed in white cement to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 60 here-in-before but on vertical surfaces as skirting, dados and risers to steps etc complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engr-In-Charge.
Cutting out bricks, forming toothing for and bonding new into old work including value of new material entering old walls and jointing and pointing in cement mortar 1:4 complete all as specified and directed by Engr-In-Charge.
Excavation in post holes (or similar holes) each n exc 0.5 cum, in soft/ loose soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in post holes/foundation/mass concrete finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
S & F Rolled sections as in main and cross beams, hips and jack rafters; purlin where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc confirming to Fe-290 (Gde-E-165) complete all as specified and directed by Engineer-in-Charge.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F mild steel box type ventilator with top hung shutter complete with sash bars dovetailed or welded and with shop coat of zinc chromate primer ready for wire mesh/ glass pan fixing complete all as specified and directed by Engineer-in-Charge.
S&F 3 mm thick plain sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire average width of aperture 1.18mm complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as per SSR Part-II complete all as specified and directed by Engr-In-Charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width & stick inside with solvent cement for stile and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the style and rail with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specifications & drawings as mentioned on Page 146 of SSR Part-II.
S&F Aluminium anodized fabricated type handle 125 mm size complete all as specified and directed by Engr-In-Charge.
S&F 100mm butt hinges medium weight, cold each rolled, mild steel complete all as specified and directed by Engineer-in-Charge.
S & F 150mm long Aluminium anodised, tower bolts with plate, stapies and bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F 150mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engr-In-Charge.
S&F 200mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engr-In-Charge.
S&F PVC connection 15mm dia 45 cm long with brass nut and washer both side complete all as specified and directed by Engr-In-Charge.
S&F GI tubing medium grade 20mm bore with all fitting and fixed to wall/ceiling and laid in floor complete all as specified and directed by Engr-In-Charge.
S&F GI tubing medium grade 25mm bore with all fitting and fixed to wall/ceiling and laid in floor complete all as specified and directed by Engr-In-Charge.
S&F Cast copper alloy stop valve/angle ball screwed down for high pressure with crutch or butter fly handle screwed both ends for iron pipe of 20mm bore complete all as specified and directed by Engr-In-Charge.
S&F 15mm bore stop valve fancy type, chromium plated, screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge.
S&F bib tap cast copper alloy, CP brass with crutch or butter fly handle screwed down screwed for 15mm bore pipe & fixed of approved make complete all as specified and directed by Engr-In-Charge.
S&F Grating doom 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacity hoisted and fixed in position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe and dismantling of old water tank complete all as specified and directed by Engineer in Charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) complete all as specified and directed by Engineer-in- charge.
S&F 110mm bore PVC(SWR) reducer complete all as specified and directed by Engineer-in- charge.
S&F Towel rail, 450mm long of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats ( minimum weight 170gms ) complete all as specified & directed by Engineer-in-Charge.
S&F Towel rail, 600mm long of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats complete all as specified & directed by Engineer-in-Charge.
S&F soap dish/ holder fixed with screws complete all as specified and directed by Engr-In-Charge.
S & F soap dish, vitreous china approximate size 160x160x90mm fixed with brass screws complete all as specified and directed by Engineer-in-Charge.
M & L for salt glazed stoneware drain pipe 150 mm dia grade 'A' laid in trenches making joints and testing complete all as specified and directed by Engineer in Charge.
M&L for Concrete bed to drain pipes using PCC 1:3:6 type C-2 40mm graded stone aggregate including packing under haunching against the sides of pipe after laid & tested for 150mm bore of pipes complete all as specified and direced by Engineer in Charge.
M & L for 50mm thick plain cement concrete (1:3:6) type B1 using 20mm graded stone aggregate as in plinth protection etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for Precast RCC as in manhole cover in CM (1:2:4) type B-1 (using 20mm graded stone aggregate), rounded or chamfered on edge complete all as specified and directed by Engr-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-In-Charge.
M & L for preparation of old plastered/RCC surfaces of wall etc and applying one coat of cement base paint complete all as specified and directed by Engineer in Charge.
S&F 3 mm thick frosted sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
Fair cutting n. exc 10cm widhth or girth on exposed surfaces of brick work such as in splays, chamfers etc including rubbed finish and waste complete all as specified and directed by Engineer-in-Charge.
S&F Gypsum board 12mm thick in ceiling fixed with screw as per manufacturer's instructions, plain / coloured fixed on steel snap grid (Powder coated bottom side) with 'T' and 'L' (25mm x 30mm x 1mm thick) size of grid 600mm x 600mm placed in ceiling 'L' section fixed with wall using PVC rawl plugs and steel screws @ 600mm centre to centre and suspended / provided 5.0mm dia galvanised bars @ 1.00 Sqm hanging arrangements and level including adjustable clips all as specified and directed. in clause 10.38 of MES Sechudle Part-I complete all as specified and directed by Engineer in Charge. (Note : If any minor electrical fittings and fixture dusturbed there in will be match and fixed as existing)
M & L Cement Concrete (1:2:4) type B1 using 20mm graded stone aggregate as in lintels upto 1.5 metre clear span, cills, steps, seismic and other similar bands, copings, kneelars, apex stones, bed plates, bed blocks of hold fasts etc including necessary form work complete all as specified and as directed by the Engineer-in-Charge.
S&F vitreous china wash down water closet pan (pedestel pattern/EWC/longpan) white in colour including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and plastic seat cover with mild steel chromoum plated hinging and 'P' or 'S' trap device complete all as specified and directed by Engineer-in-Charge.
S & F CP brass health faucet with 1.0mtr tube & hook (braded tube) complete all as specified and directed by Engineer in Charge. Make : Prayag or equivalent
S&F Toilet paper holder vitreous china fixed to wall with chromium plated brass screws complete all as specified & directed by Engineer-in-Charge.
S&F brass chromium plated towel rail 20mm dia, D type, 600mm long between flanges fixed with CP brass screws including wooden/plastic beads complete all as specified and directed by Engineer in Charge.
S&F stainless steel grating of any size as per existing with or without waste hole complete all as specified and directed by Engr-In-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and ren-dering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming bench-ing as required (Internal Dia of pipe in 150mm) complete all as specified and directed by Engr-In-Charge.
S&F PVC hollow wall lining interlocking type of 7mm thick plain/coloured / wood grain printed fitted in to the wall with PVC rawal plug and steel screws including fillets on joints/corners/ends (if required) as per manufacturers instruction etc.complete all as specified and directed by Engineer-in-Charge. Note:- If any minor electric fittings and fixtures disturbed there will be match and fixed as existing.
M&L Brick work with fly ash with old size sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 10mm thick in cement mortar (1:4) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M&L for moorum/red bajri filling in floors or paving, laid in layers n exc. 15 cm thick, spread, leveled and rammed including watering in and under transformer platform complete all as specified and directed.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
S & F Non skid ceramic coloured tiles light colour (as approved) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry over & including 15 mm thick screed in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
M & L Glazed ceramic tiles, coloured (light colour as approved), of size 300X200X7 mm (or size available in market as decided by engr-in-charge) thick on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engr-In-Charge.
S&F ball brass valve high pressure, with polythene float and fly nut complete screwed for iron or brass ferrule of 20mm bore complete all as specified and directed by Engr-In-Charge.
S&F pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down, high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and fixed complete all as specified and directed by Engineer in Charge.
S & F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 15 mm dia of pipe complete all as specified and directed by Engineer in Charge.
S & F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 25 mm dia of pipe complete all as specified and directed by Engineer in Charge.
M & L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in manhole cover slab rounded or chamfered on edge included neccessary formwork complete all as specified and directed by Engr-In-Charge.
S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 150mm (internal dia) all as specified and directed by Engineer in Charge.
M & L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as concrete bed to drains pipe ( RCC pipe) 150mm internal dia including packing under and haunching against the sides of pipes with concrete after they are laid and tested complete all as specified and directed by Engr-In-Charge.
S&F 110mm bore door type PVC (SWR) bends / shoe of any radius complete all as specified and directed by Engineer-in-Charge.
S&F 15mm dia stop cock cast copper alloy with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
Supply & fixing vitreous china half stall type urinal flat back, size of 345 x 320 x 560 mm white (minimum), with grating and union for discharge pipe, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, including Urinal spreader of PTMT suitable for fixing with 15 mm dia pipe and including Push tap high pressure of PTMT screwed for iron pipe 15mm bore (Minimum weight 47gms) complete all as specified & directed by Engineer-in-charge.
M & L for cement concrete 1:2:4 (using 20mm graded stone aggregate) as in surface channel and drains including necessary form work complete all as specified and directed by Engr-In-Charge.
M & L PVC waste & vent pipe fixed to urinal bowl outlet complete all as specified and directed by Engineer in Charge.
M & L for priming surfaces and applying normal treatment using bitumen primer @ 0.70 Ltr/Sqm complete all as specified and directed by Engineer in Charge.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm incl cleaning surface complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and directed by Engineer in Charge.
M & L for 100mm thick cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed by Engr-In-Charge.
M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M&L for factory made Pre-cast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in kerb stone of any size or as per site requirement with plain fair faces, smooth finish, including chamfering, weathering, throating etc set in cement mortar 1:4 including necessary form work and excavtion and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 Mtr and depositing where directed complete all as specified and directed by Engineer in Charge.
M & L cutting existing steel tubing for alternations or additions bore of pipe 25 of 32mm and screwing to form a new connection without taking down existing steel tubing complete all as specified and directed by Engineer in Charge.
M & L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and applying cement slurry @ 3 Kg/Sqm complete all as specified and directed by Engineer-in-Charge.
M & L Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep (best quality of granite, trap, basalt) and sides dressed, bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metalic floor hardner 5% by weight of cement and struck flush complete all as specified and directed by Engineer-in-Charge.
M & L Stone sett edging with stone setts of size 250 to 300mm long, 150 to 200mm wide and 450mm deep (best quality of granite, trap, basalt) and sides dressed, bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metalic floor hardner 5% by weight of cement and struck flush complete all as specified and directed by Engineer-in-Charge
M & L cutting of existing gate frame / MS sheet to maintain the gap for stone sett flooring and removing of existing MS sheet from angle iron (any thickness) complete all as specified and directed by Engineer-in-Charge.
Dismantling of structural steel work with proper care / without any damage to doors, gates, angle iron framed /welded works for reuse in same / other places complete all as specified and directed by Engineer-in- charge. (Reuse item will be measured & paid separately under respective item of this BOQ.)
Labour Only for fabrication, erection and fixing only retrieved framed work as in door or gates of angle or other section with gusset plates, rails, braces etc complete drilled, welding for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging of sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of running rails and guiders) and hanging : also fastening and fixing complete all as specified and directed by Engineer-in-Charge. Note : Existing heavy steel gates to be secured / makes good by using retrieved angle iron and MS sheet)
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC strandedcopper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for One light point/call bell point/fan point to be controlled by one number one way PT switch complete all as specified and directed by Engineer in Charge.
S&F switch piano type single pole one way 5 Amps, 230 volts complete all as specified and directed by Engineer-in-Charge.
S & F exhaust fan 380mm sweep, 900 RPM trans air 70 Watt, with louver shutter suitable for operation on 220/230 volts, single phase , AC supply and complete all as specified & directed by Engr-in-charge.
Supply & Laying of XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with standard aluminium conductor 1100 volts grade confirming to IS-1554 cross sectional area 10 Sqmm 2 core including thimbles/lugs complete with and including passing through pipes or laid under floor or through walls etc all as specified and directed. (Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)
S&F in replacement MCB distribution board double door of sheet metal single pole and neutral 4 way with 200 amps rated bus bar 240 volts complete all as specified and directed by Engineer in Charge.
S&F MCB,SPN 240 volts 32 Amp breaking capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB single Pole 240 Volts 6 to 40 Amp breaking capacity 10 KA complete all as specified and directed by Engineer in Charge.
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed by Engineer in Charge
M & L for sand cushioning with river washed and screened dry fine sand to under ground cable 23cm thick, 15 cm below the cable and 8 cm after laying the cable complete all as specified and directed by Engineer-in-Charge. NOTE;- Thickness after punning shall be considered for payment.
S&F mild steel tubes of size 40mm bore (light grade) galvanised for cable protection fixed to poles/laid under floor/under road crossing etc. complete all as specified & directed by Engineer-in-charge.
Supply & Fixing and testing LED light fitting 1 x 20 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 1700 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin suitable for Gas/vapur of IIA & IIB and Zone 1 & 2 including connecting up with twin core twisted flexible copper conductor with suitable size complete all as specified and directed by Engineer-in-Charge. Note :- A Sum of Rs. 3,290.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 30 (Schedule of credit) of Tender Documents.
BABA FARID CONSTRUCTION CO
ARORA CONSTRUCTION CO.
HARBHAJAN SINGH KHARBANDA
DARSHAN SINGH JOHAL AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .