Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC accepted |
| 2 | L2₹1.2 Cr+₹8.1 L (7.46%)Rejected-Finance | ₹1.2 Cr+₹8.1 L (7.46%) | L2 | Rejected-Finance rejected |
| 3 | L3₹1.3 Cr+₹19.2 L (17.6%)Rejected-Finance | ₹1.3 Cr+₹19.2 L (17.6%) | L3 | Rejected-Finance rejected |
| 4 | L4₹1.5 Cr+₹39.8 L (36.6%)Rejected-Finance | ₹1.5 Cr+₹39.8 L (36.6%) | L4 | Rejected-Finance rejected |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
27 Jan 2020, 3:00 pmClosed
CCE(RND) South
AKBAR ROAD, SECUNDERABAD
Provision of Addition Alteration to Spic Hanger In Technical Area at RCI, Hyderabad
2020_DRDO_533650_1
83562/CIV/SPIC/CON
Limited
Civil Works
Item Rate
360 days
RCI, HYDERABAD
as per NIT
2 documents required · 2 mandatory
₹2,000
CCE(RND) SECUNDERABAD
₹2.6 L
13 Mar 2020
6 Jan 2020
29 Jan 2020
6 Jan 2020
27 Jan 2020
13 Jan 2020
7 Jan 2020 - 10 Jan 2020
Amount
ADDITION/ ALTERATION
Providing and fixing full height partitions partly glazed with aluminium frame (JINDAL or HINDALCO MAKE) anodized, powder coated (As per IS code), with suitable heavy type manufacturer specific sections to be provided for partitions with necessary rubber gaskets and aluminium beadings as approved by the engineer in charge. All partitions are 75mm thk. The partition will have 12mm.,thk particle board with 1 mm thk laminate on both sides (IS grade) from FFL to 1200mm and glass upto 800mm ht and above upto ceiling fixed with 12mm thk particle board with 1 mm laminate on both sides. The complete frame shall be firmly fixed to floors, wall, and ceilings. The costs must include leads, lifts, assembling, fixing and placing in position and also suitable intersection points to completed as directed by Engineer in Charge. All color or shades as approved by engineer in charge. Make should be Greenply or Century or equivalent ply for particle board and Laminate. Make should be saint gobainor MODI or equivalent for clear glass. NA.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks)
Providing and fixing door of 2000x2650mm including frame aluminium sections JINDAL or HINDALCO MAKE' anodized and powder coated (As per IS code), with suitable heavy type manufacturer specific sections to be provided for doors with necessary rubber gaskets and aluminium beadings as approved by the engineer in charge. The door to have 12mm thk particle board with lmm laminate on both sides upto 1200mm ht and balance to be in 6mm thk clear glass. The door will be fitted with SS handles, hinges, screws, gordej mortise lock, stopper, tower bolt of 225x10mm, as necessary, and be mounted on floor springs. The costs musts include leads, lifts, assembly, fixing and placing in position as directed by Engineer in charge as per drawing. All color orshades to be approved by engineer in charge. Make should be Greenply or Century ply or equivalent for particle board. Make should be saint gobainor MODI or equivalent for clear glass
Providing and fixing door of 1000x2100mm including frame aluminium sections JINDAL or HINDALCO MAKE' anodized and powder coated (As per IS code), with suitable heavy type manufacturer specific sections to be provided for doors with necessary rubber gaskets and aluminium beadings as approved by the engineer in charge. The door to have 12mm thk particle board with lmm laminate on both sides upto 1200mm ht and balance to be in 6mm thk clear glass. The door will be fitted with SS handles, hinges, screws, gordej mortise lock, stopper, tower bolt of 225x10mm, as necessary, and be mounted on floor springs. The costs musts include leads, lifts, assembly, fixing and placing in position as directed by Engineer in charge as per drawing. All color orshades to be approved by engineer in charge. Make should be Greenply or Century ply or equivalent for particle board. Make should be saint gobainor MODI or equivalent for clear glass
Providing and fixing door of 1000x2100mm including frame aluminium sections JINDAL or HINDALCO MAKE' anodized and powder coated (As per IS code), with suitable heavy type manufacturer specific sections to be provided for doors with necessary rubber gaskets and aluminium beadings as approved by the engineer in charge. The door to have 12mm thk particle board with lmm laminate on both sides upto 1200mm ht and balance to be in 6mm thk clear glass. The door will be fitted with SS handles, hinges, screws, gordej mortise lock, stopper, tower bolt of 225x10mm, as necessary, and be mounted on floor springs. The costs musts include leads, lifts, assembly, fixing and placing in position as directed by Engineer in charge as per drawing. All color orshades to be approved by engineer in charge. Make should be Greenply or Century ply or equivalent for particle board. Make should be saint gobainor MODI or equivalent for clear glass
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and laying in position Cement Concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand).
6 mm Thick Plastering in cement mortar 1:3 (1 cement: 3 fine sand) at all levels and locations for all concrete surfaces of columns, beams,walls, and slabs finished smooth and even etc., complete.
Providing and fixing 12 mm thick toughened glass of approved brand and manufacture, fixing arrangement and making necessary holes etc. for fixing , all complete as per direction of Engineer-in-charge
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
FOR RAIN PROTECTION
Earth work in excavation by mechanical means (Hydraulicexcavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.
All kinds of soil
Providing and laying in position Cement Concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for Reinforced Cement Concrete Work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :-cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
Supplying fabricating and fixing in position Reinforcement Steel for RCC work at all levels and locations including the cost of steel, straightening, cutting,bending,binding and placing in position etc.,as per drawings and specifications including the cost of binding wire labour etc., complete for reinforced concrete.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and Shuttering including strutting, propping etc and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing & fixing of galvalume sheet of approved colour and manufature on ceiling/ roof supported over aluminium section frame work fixed with dash fastner etc complete as per manufacture specifications and direction of the project engineer including necessary scafolding all as directed by the engineer
CAR & SCOOTER PARKING, OVER HEAD WATER TANK
SUBHEAD-I : EARTH WORK
Earth work in Excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Excavation Work by Mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary Rock
Hard Rock (Blasting prohibited)
Extra for every Additional Lift of 1.5 m or part there of in excavation / banking excavated or stacked materials.
All kinds of soil
Ordinary or hard rock
Supply of of approved Earth obtained from outside MOD land filling in layers not exceeding 20cms thick at all heights and depths in foundations, pits, trenches, sewer lines around structures and foundation under floors other places including dressing and levelling watering, consolidation to achieve minimium of 95% proctor density etc., complete as per drawing specifications, payments shall be made for the quantity after deducting the voids.
SUBHEAD-II : ANTI TERMITE TREATMENT
Supplying Chemical Emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and Injecting Chemical Emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
SUBHEAD-III : PLAIN AND REINFORCED CEMENT CONCRETE WORK
Providing and laying in position Cement Concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for Reinforced Cement Concrete Work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :-cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Supplying fabricating and fixing in position Reinforcement Steel for RCC work at all levels and locations including the cost of steel, straightening, cutting,bending,binding and placing in position etc.,as per drawings and specifications including the cost of binding wire labour etc., complete for reinforced concrete.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
CENTERING AND SHUTTERING :-
Centering and Shuttering including strutting, propping etc and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
SUBHEAD-IV: STONE WORK & BRICK WORK
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Providing and placing in position 2 Nos 8mm dia. M.S. Bars at every third course of half brick masonry.
Cement mortar 1:4 (1 cement : 4 coarse sand).
SUBHEAD - V: PLASTERING & SURFACE TREATMENT
6 mm Thick Plastering in cement mortar 1:3 (1 cement: 3 fine sand) at all levels and locations for all concrete surfaces of columns, beams,walls, and slabs finished smooth and even etc., complete.
15 mm cement plaster half brick wall of mix:
1:6 (1 cement: 6 coarse sand)
SUB HEAD - VIII : ROOF WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Crimp curve
AIR CONDITIONING
Supply, Installation Testing & Commissioning of 2TR High Wall Split Air Conditioners including rotary compressor, condenser, supports with cordless remote controller, refregerant gas, etc Units shall operate on R 410a refeigerant and shall be inverter type. Units shall be of 5 star rating
INTERNAL ELECTRIFICATION
Lights Points
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
GROUP-C
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 5/6 A modular switch, connections etc. as required.(Group Lighting & exhaust fans)
Supply and Wiring with the following size 1100V grade FRLS insulated multistranded Copper wires in & including suitable size heavy guage FRLS PVC ISI mark conduit concealed in wall after necessary chase cutting with finishing/ Surface on wall / Ceiling including all accessories such as junction boxes, bends, elbows and end terminated with suitable lugs.
2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm in 20mm dia FRLS PVC ISI mark conduit (For Lighting Circuits & 6A Independent sockets)
Light/Fan Fixtures
Supply of the following LED Light Fixtures with electronic driver , heat dissipating element including necessary accessories etc., complete on wall/ Ceiling / suspended from ceiling/ recess including all fixing accesssories such as leads,Teak wood round block, downrods, MS clamps, nuts, GI chain and bolts etc complete as required. All the light fixtures will be finally approved by CCE R&D South.
40W LED luminaire Recess Mounted 2ft x 2ft LED Luminaire with Diffuser similar to Philips Cat No: SM365C LED32-6500 PSU OD WH / Equivalent Make of Wipro.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Wall Mounted Air Circulator Fans
Supply and Installation of Wall Mounted Air circulator fan of following sweep (white colour), suitable for operation on 230 / 240V, 50 Hz, single phase, A.C, supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete.
600mm Sweep Air Circulator fans Compton Cat No: ACVORTEX24WM) Similar to Bajaj and Havells.
POWER WIRING
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (For AC Units)
Supply and Wiring with the following size 1100V grade FRLS insulated multistranded Copper conductor wires in & including suitable size heavy guage FRLS PVC ISI mark conduit concealed in wall after necessary chase cutting with finishing/ Surface in wall / Ceiling including all accessories such as junction boxes, bends, elbows including and terminated with suitable lugs.
2 runs of 4 Sq.mm wires with 1 run of 4 Sq.mm in 20mm dia FRLS PVC ISI mark Conduit (for 16A Sockets)
2 runs of 6 Sq.mm wires with 1 run of 6 Sq.mm in 20mm dia FRLS PVC ISI mark Conduit (for AC Sockets)
4 runs of 10 Sq.mm wires with 2 run of 6 Sq.mm in 25mm dia FRLS PVC ISI mark Conduit (for Lighting DB)
4 runs of 16 Sq.mm wires with 2 run of 6 Sq.mm in 25mm dia FRLS PVC ISI mark Conduit (for Power DB)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63A 415V Four Pole MCB
40A 415V Four Pole MCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
4 way (4 +12), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40A, Four Pole, RCBO, 30mA.
63A, Four Pole, RCBO, 30mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
TELEPHONE CONDUITING
Supply and laying of 20mm dia. 2mm thick FRLS PVC ISI mark conduit concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Telephones/LAN etc
Supply and fixing of Telephone outlet (RJ11) with anodised GI box of with front plate and telephone socket
Supply and laying of 2pair 0.5mm dia PVC insulated unarmoured copper conductor Telephone wire conforming to DOT Specifications
Supply and installation of following size Krone connectors in MS box complete as required.
Supply and fixing of LAN outlet (RJ45) with anodised GI box with front plate and plug in type LAN socket .
EXTERNAL POWER SUPPLY
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125A,16KA TPN MCCB
Earthing
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
MV Cables
Supply of following size 1.1KVgrade XLPE insulated armoured aluminium conductor underground cable, The cable shall conform to IS 7098 Part-1.
3.5C X 50 sq.mm Aluminium
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 95sq. mm and upto185 sq. mm
Providing double compression end terminations for the cable specified above with compression type gland, lugs using crimping tool, Insulation tape, Identification tags etc.,including end termination and Earthing of Gland.
3.5C X 50 sq.mm Aluminium
Hi-Tech Infrastructure
SREE LAKSHMI CONSTRUCTIONS
ELIXIR MET FORM PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .