Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | ₹43.0 L Quoted ₹44.1 L | L1 | Accepted-AOC Accepted due to lowest rate quoted |
| 2 | L2₹45.4 LRejected-Finance | ₹45.4 L | L2 | Rejected-Finance Rejected due to highest rate quoted |
| 3 | L3₹46.9 LRejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | ₹46.9 L | L3 | Rejected-Finance Rejected due to highest rate quoted |
| 4 | L4₹47.1 LRejected-Finance | ₹47.1 L | L4 | Rejected-Finance Rejected due to highest rate quoted |
| 5 | L5₹47.4 LRejected-Finance | ₹47.4 L | L5 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | Goyal Enterprises L2 | JAIPAL AND BROTHERS L6 | akhil enterprises L3 | KISHAN SINGH AND CO L9 | M/S DABAS CONSTRUCTIONS L10 | M/S RK Builders L1 | M/s Nikhil Kumar Builders L7 | Shiv Shakti Builders L4 | Mohd Talha L5 | P R Constructions L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified. | 64.55 | Cum | 211 ₹13,620.05 | 200 ₹12,910 | 200 ₹12,910 | 200 ₹12,910 | 500 ₹32,275 | 200 ₹12,910 | 200 ₹12,910 | 200 ₹12,910 | 100 ₹6,455 | 400 ₹25,820 |
| 2.00 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified. | 740 | Sqm | 17 ₹12,580 | 20 ₹14,800 | 50 ₹37,000 | 25 ₹18,500 | 150 ₹1.1 L | 20 ₹14,800 | 20 ₹14,800 | 5 ₹3,700 | 10 ₹7,400 | 20 ₹14,800 |
| 3.00 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description in any position not specifically provided complete complete all as specified. | 2.2 | Cum | 251 ₹552.20 | 200 ₹440 | 300 ₹660 | 1,000 ₹2,200 | 1,000 ₹2,200 | 200 ₹440 | 500 ₹1,100 | 500 ₹1,100 | 100 ₹220 | 500 ₹1,100 |
| 4.00 | Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified. | 30.17 | Cum | 190 ₹5,732.30 | 200 ₹6,034 | 200 ₹6,034 | 200 ₹6,034 | 800 ₹24,136 | 100 ₹3,017 | 200 ₹6,034 | 100 ₹3,017 | 100 ₹3,017 | 400 ₹12,068 |
| 5.00 | Demolition of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc. | 7 | 10 Sqm | 170 ₹1,190 | 100 ₹700 | 200 ₹1,400 | 150 ₹1,050 | 600 ₹4,200 | 200 ₹1,400 | 200 ₹1,400 | 100 ₹700 | 100 ₹700 | 200 ₹1,400 |
| 6.00 | Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc including roof tiles complete all as specified and as directed. | 28 | Cum | 300 ₹8,400 | 500 ₹14,000 | 300 ₹8,400 | 500 ₹14,000 | 700 ₹19,600 | 200 ₹5,600 | 200 ₹5,600 | 500 ₹14,000 | 300 ₹8,400 | 600 ₹16,800 |
| 7.00 | M&L for cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) 25 mm thick as in sub base of flooring/tiles etc complete all as specified. | 281 | Sqm | 211 ₹59,291 | 100 ₹28,100 | 150 ₹42,150 | 150 ₹42,150 | 200 ₹56,200 | 220 ₹61,820 | 150 ₹42,150 | 50 ₹14,050 | 300 ₹84,300 | 200 ₹56,200 |
| 8.00 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified. | 281 | Sqm | 210 ₹59,010 | 100 ₹28,100 | 120 ₹33,720 | 220 ₹61,820 | 150 ₹42,150 | 100 ₹28,100 | 150 ₹42,150 | 99 ₹27,819 | 50 ₹14,050 | 180 ₹50,580 |
| 9.00 | M&L 10 mm thick rendering in cement mortar (1:3) on vertical surfaces for backing of tiles etc complete all as specified. | 210 | Sqm | 211 ₹44,310 | 100 ₹21,000 | 200 ₹42,000 | 220 ₹46,200 | 140 ₹29,400 | 120 ₹25,200 | 200 ₹42,000 | 99 ₹20,790 | 300 ₹63,000 | 150 ₹31,500 |
| 10.00 | M&L for Non - skid (joint free) coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. | 281 | Sqm | 777 ₹2.2 L | 700 ₹2.0 L | 900 ₹2.5 L | 800 ₹2.2 L | 400 ₹1.1 L | 750 ₹2.1 L | 900 ₹2.5 L | 700 ₹2.0 L | 900 ₹2.5 L | 1,000 ₹2.8 L |
Tender Value
₹48.5 L
EMD Value
₹98,000
Closing Date
4 Mar 2026, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
SPECIAL REPAIR TO CERTAIN OTM BUILDINGS AT AFS ISSAPUR C/O 25WG AND SPECIAL REPAIR TO MAIN ENTRY GATE AT 25 WG AF STN RAJOKRI UNDER GE (AF) GURGAON
2026_MES_752325_1
GE/GUR-/NIT-138/2025-26
Open Tender
Civil Works
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹98,000
18 Mar 2026
11 Feb 2026
6 Mar 2026
11 Feb 2026
4 Mar 2026
25 Feb 2026
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description in any position not specifically provided complete complete all as specified.
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified.
Demolition of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc.
Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc including roof tiles complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) 25 mm thick as in sub base of flooring/tiles etc complete all as specified.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified.
M&L 10 mm thick rendering in cement mortar (1:3) on vertical surfaces for backing of tiles etc complete all as specified.
M&L for Non - skid (joint free) coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L for Glazed ceramic coloured tiles in vertical surface 600X300X 6-7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified.
M&L for 18-20 mm thick Granite tiles machine cut , bedded and jointed with grey cements slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including grinding & polishing slab over screed bed or bedding layer of mortar 15 mm thick in cement mortar (1 : 4) laid complete all as specified.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as specified.
M&L of holes in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors ® complete all as specified.
M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in roof padding complete all as specified & as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified. Notes : WPC shall be measured and paid seperately.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions including aluminium paint on top surface complete all as specified.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified.
M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified.
M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified.
M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending , spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 5 cm but n exc 10 cm wide rough finished complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified.
M&L for 15 mm thick plastering in two layers (10+5) mm in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement), top layer shall be with WPC as per manufacturer's instruction and complete all as specified. Note: WPC shall be measured and paid separately.
M&L rendering 10mm thick in cement mortar (1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified.
Supply only intergral water proofing compound ISI Marked complete all as specified.
M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre over a coat of primer, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified
M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper over a coat of primer on walls complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. (c) Wall care putty shall be measured and paid seperately.
M&L for preparation of plastered or unplastered old decorated surface of ceiling by complete removal of existing treatment by mechanised sander of berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre over a coat of primer, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall/ceiling surface including filling of holes and cracks with with suitable material like cement or plaster of paris etc thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Stage for complete removal of existing surface & Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
M&L for repairing of RCC projection chhajjas,mumty roof bottom, facia etc by necessary preparation. Scraping cutting, chiseling derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC with cement concrete (1:1.5:3) using 20mm graded stone aggt and reinforcement with welded mesh of weight 2 Kg per Sqm but n.exc 3 Kg per Sqm (if reqd) with or without facia and finished with cement and sand mortar (1:3) using coarse sand and work in patches area n.exc 10 Sqm and thickness of RCC member n.exc 120 mm incl necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete all as specified and as directed by Engr-in-Charge. (The rate quoted by the contractor shall included for welded mesh, scaffolding and necessary formwork upto triple storey bldg).
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified.
S&F solid PVC door frame of size 50mm X47mm made out of 5mm single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing.
S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of prelam PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable prelam PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing as specified.
S&F Brass Locks 4 lever, cupboard, grade I, size 75 mm complete.
S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm long hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified.
S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items)
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified.
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed.
Hacking out old broken glass (any thickness, size, quality or escription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S&F sheet glass 4 mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified.
M&L for 5.5 mm thick sheet glass ordinary quality and glazing each pane fixed with including neopune rubber gasket in aluminium frame work complete all as specified and directed.
S&F 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, including decorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps to fixed to walls complete all as specified.
Dismantling of cast iron pipe up to 100 mm dia, jointed in cement mortar and taking out in trenches/Wall if required etc complete all as specified.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to walls complete all as specified.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches or floor complete all as specified.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches or floor complete all as specified.
S&F 110 mm dia PVC (SWR) vent cowl complete all as specified.
S&F 110 mm dia PVC (SWR) bends with rubber rings joints fixed as required complete all as specified.
S&F 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal with rubber rings joints fixed as required complete all as specified.
S&F 75 mm dia PVC (SWR) junction single, (Single T) equal or unequal with rubber rings joints fixed as required complete all as specified.
M&L PVC (SWR) 75 mm floor trap plain with grating including jointing with solvent cement complete all as specified.
S&F PVC (SWR) 'P’ trap 125 mm complete all as specified.
S&F 110mm PVC (SWR) WC connector bent type complete.
Taking up or down steel tubing 15mm bore and connection including cleaning for refixing or removal to store. complete all as specified.
All as per item No. 64 here-in-before but 20mm dia .
Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall etc complete all as specified.
Supplying and laying of 25mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supply and fixing in CPVC 20mm Brass Elbow
Supply and fixing in CPVC 20mm Brass Tee
Supply and fixing in CPVC 20mm Male Brass Threaded Adaptor (MTA/ MBTA)
Supply and fixing in CPVC 20mm Female Brass Threaded Adaptor (FTA/ FBTA)
Supply and fixing in CPVC 25mm Tank Adaptor
Supply and fixing in CPVC 20mm Union
S&F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified.
S&F as in repair vitreous china squatting pan, white, orissa pattern, size 580x440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron ‘P’ trap incl lime concrete bedding and making good to the disturbed surface to match with the existing surface of floor complete all as specified.
S&F in repair white vitreous China wash down water closet pan (pedestal pattern), and trap (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc. complete all as specified.
S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified.
S&F in repair vitreous china wash hand basin (flat back) of size 550x400mm with padestal including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, including cutting for and pinning in ends of brackets complete all as specified.
S&F Soap dish of chromium plated or stainless steel fixed to wall with chromium plated brass screws.
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified.
S&F in repair 15 mm dia angle valve, cast copper alloy screwed down high pressure, fancy type chromium plated screwed both ends for iron pipe or unions complete all as specified.
S&F in repair angular two way angle cock with wall flange, 15 mm nominal bore cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified.
S&F in repair bib taps long body, brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket with water saving aerator complete all as specified.
S&F in repair Pillar cock with swan neck spout (left/right) and aerator , 15mm bore chromium plated fancy type complete all as specified.
S&F in repair 100 mm chromium plated grating complete all as specified.
S&F chromium plated health faucet telephonic type with 8mm dia, 1 meter long CP flexible with wall hook and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified.
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified.
S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified.
S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified.
Dismantling wrought iron or mild steel work of any description
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified.
S&F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, without any attachment confirming to Fe 410-S complete all as specified.
M&L for excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft and loose soil complete all as specified.
M&L for cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified & directed.
M&L prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified
Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc Complete all as specified.
M&L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified.
S&F in repair Double legged Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm, complete all as specifed and direcetd.
S&F in repair aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over a coat of primer premium quality complete all as specified and as directed.
M&L 100 mm thick PCC 1:4:8 tybe D-2 using 40mm stone aggregate as in subbase.Complete all as specified
M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified.
M&L for 22-25 mm thick chequered designer coloured tiles (matt/glass finish), size, colour and shape as approved by GE, set and jointed in neat cement slurry and pointed with coloured cement to match etc complete all as specified as directed.
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete.
Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed.
Surface dressing n.exc 15 cm deep and getting out soft/loose soil all as specified and directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for foundation, or for man holes etc., n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil.
M&L for plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete.
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exc 25 cm back side of wall complete all as specified.
Removing excavated material not exc 50 m and depositing where directed (soils) at a level not exc. 1.5 mts above the starting point.
M&L Reinforced cement concrete Nominal mix Type B1 1:2:4 (using 20 mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete.
M&L Reinforced cement concrete Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregates) as in Columns pillars, post and struts
M&L for Reinforced cement concrete Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified.
M&L for Precast renforced cement concrete 1:2:4, type B1 using 20 mm graded stone aggregate as in cover slab with plain fair faces inclduding setting in CM 1:4 complete all as specified and directed.
M&L for flat form work to sides of rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work vertical or to batter .
M&L for form work to sides of pillars,posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for form work to sides and soffits of roof beam, beam haunchings, girders, bressummers, lintels ,cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc., flat fair finished surfaces .
M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hopping for columns,hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia confirming to TMT bars complete all as specified.
M&L for ditto but 5 mm and over upto and including10 mm dia as in stirrups
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified.
M& L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for handing or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing Fe 410-W (Gde E-250)complete all as specified and directed
S&F Mild steel, plain black sheet 1.25mm thick in wall cladding, steel gates & similar work, cut to size, holes punched; including round headed screws, clout nails or rivets & fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
S&F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts post and struts in fencing including cutting tops to shape as directed , drillling holes, notching for wire etc, flet ironfillets (for securing wire mesh etc.) including all necessary drilling, bolting etc and similar work conforming to Fe-290 Gde E- 165
S&F for stainless steel (grade 304) railing made of hollow tubes, channels, plates etc, including embedded in cement concrete 1:3:6 to floors and welding, grinding ,buffing, polishing and making curvature(wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories like SS ball caps ,floor caps etc complete all as specified and as directed.
S&F for stainless steel (grade 304) chain including necessary welding at joints, grinding to SS railing etc including taking down old UNSV SS chain etc all as specified and as directed.
S&F for Fibre glass reinforced coloured translucent semi-corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc.
S & F in repair Galvanised 2 strand, steel barbed wire 2.24 mm dia, barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as specified and directed (each line wire to be measured)
S&F in repair re-inforced punched concertina coil of 600 mm dia (chrome razer or blade wire) with barbed tape of 0.50 mm thick galvanised steel steel sheet or core wire of dia 2.5mm of high tensile steel wire including galvanised mild steel staple/clips for tying at crossing etc complete all as specified.
M&L for brick work with flyash bricks, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level).all as specified and directed.
M&L for plain cement concrete type-C2 1:3:6 (40mm garaded agg.) in surface channel and drains complete all as specified and directed
Extra for forming fair finished drain or channel 40 cm inner girth in cement concrete, using extra cement, incl forms, moulds, mitred / stopped ends etc, complete all as specified and directed.
M& L Rendering in CM (1:4) 15 mm thick on fair faces of brick/ concrete surfaces finished even and smooth without using extra cement incorporating integral water proofing compound.
M & L for hard core of gauge n exc 63mm, deposited spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface.
M&L 100 mm thick PCC 1:4:8 tybe D-2 using 40mm stone aggregate as in sub base complete all as specified.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-35 Grade complete all as specified and directed.
M&L for Sand (M Sand) filling under interlocking tiles or in foundations, spread and levelled including watering and consolidation complete.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete.dust, etcwashing down with water to remove dust, etc
S&F Factory made machine pressed Chequered cement concrete colour tiles 30 cm X 30 cm X22 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified.
M&L for PCC 1:3:6 typeC1 using 20mm gradded aggregate as in coping,cills ,string courses,apex stone,bed plates,kerbs etc. and necessary formwork all as specified.
Providing edge moulding 18-20 mm thick stone (any description) of counters vanities etc, including machine polishing to edge to give high gloss finish etc. complete to granite stone any description all as specified
M & L for stainless steel letter, arrow of size of height exc 250mm and n.exc 300 mm of sectional area not less 900 Sqmm, fixed to any surface including necessary fixing arrangements with chemical /adhesive including screwing with stainless steel screws etc., complete all as specified and as directed.
M&L Preparation of newly plastered surfaces of wall and applying two coat of Cement Base Paint of approved colour and shade by accepting officers over and including a coat of alkali resistant primer as per manufacturers instructions complete all as specified and directed
S&F in repair of monoblock submersible 3 phase, 415 volts 50 cycle A/C supply with suction bends 5 H P Pump should be of standard make and conforming to IS:8034 or any other relevant standard etc completed all as specified and as directed. (Make-Kirloskar/crompton)
M & L for developing lawn with Bermuda grass including necessary earth work, excavation planting to a depth of 10cm in all types of soil, removal of all construction debris, filling with 7.5cm thick black soil which is free from stone, pebble weeds, debris etc and 2.5 cm thick garden soil and manure mix with proporation 3:1, removal of surplus soil, all construction debris, weeds to a distance of n.exc 50m and levelling ground, applying of soil pesticides, transplanting of Bermuda grass at a spacing 3'', routing, watering etc complete all as directed.
M&L for developing trees/plants by digging pits given in notes below and filling with soil obtained from that location 50% of height and balance with garden soil mixed with manure 3:1 ratio and planting trees of height above ground level, removal of surplus soil, all construction debris, weeds to a distance n.exc. 50 m, applying soil pesticides, routing, watering etc. complete including bamboo spike for holding the plant in position and filling soil mixture of garden soil and manure in ratio (3:1). NOTE: 1. The garden soil and mixture mix to be filled in pits only to be measured under this item. 2. The foundation pit shall be of size 0.45 x 0.45 x 0.60 m. 3. Cost of plant shall be paid seperately on supply only.
Filling soil mixture of garden soil and manure (3:1) Note: The garden soil and manure mix to be filled in pits only will be measured under this item.
Palm Tree(4' ht)
UGAOO Spider plant (1' ht)
Bougan Villa(1' ht)
Taking down carefully old copper/alluminium point, wiring (light, fan, socket or power) complete, including fitting such as switches, ceiling roses, pendants, regulator socket tube light fitting of any type, Bulk head fitting etc segregation serviceable fitting/fixture and keep them safe custody for reuse and removing materials from the site and making good disturbed surface of walls&floors etc as per existing specification complete all as directed
Taking down old unserviceable main switch, DB's/RCBOs/MCCB/Sheet Metal Enclosures including MCBs & wooden/GI/MS sheet board etc and removing materials from the site of work complete all as directed
M&L for point wiring complete with stranded copper conductor1.5 sqmm single core (nominal area ) PVC insulated and unsheathed cable 650 volts grade drawn in and including medium duty concealed in PVC concealed conduit conforming to IS and ISI marked not less than 19 mm dia with 1.6mm thick concealed pressed steel terminal boxes with plate and framecover for rquired module including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable in same conduit as earth wire to the common earth and connecting to earth dolly all as specified for
(a) One light point/bell point/one fan/exhanust fan controlled by one,one way switch.
(b) For one 5 pin, socket outlet 5/6 amp on independent board with other switches
(c) For one 3 pin socket outlet 5/6 amp on same board
M&L for point wiring complete with stranded copper conductor 4 sqmm single core (nominal area ) PVC insulated and unsheathed cable 650 volts grade drawn in and including medium duty concealed in PVC concealed conduit conforming to IS and ISI marked not less than 19 mm dia with 1.6mm thick concealed pressed steel terminal boxes with plate and framecover for rquired module including single core stranded copper conductor 2.5 sqmm PVC insulated unsheathed cable in same conduit as earth wire to the common earth and connecting to earth dolly all as specified for one 6 pin socket outlet two in one 16/6 amps on an independent board.
M&L for switch modular type single pole one way 6 amps complete all as directed by Engr - in - charge.
M&L switch socket combination 2 in 1, 6 Amp modular Type 5 pin multipurpose suitable for independent board complete all as specified by Engr-in-Charge
M&L socket outlet 2 in 1,3/5 pin 6 Amp modular type multipurpose suitable for same board complete all as specified by Engr-in-Charge
M&L switch socket combination 2 in 1, 5 pin multipurpose 16 A , modular type.
S&F in replacement of tube light fitting 1X20 w,LED Batten wall mounted with alumunium housing and integrated electronic driver .
S&F in replacement of tube light fitting 1X10 w,LED Batten wall mounted with alumunium housing and integrated electronic driver .
S&F in replaceent of MCB DB sheet enclosure load line SPN 240V with 200 Amp suitable Size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic double door complete confirming to IP 43 with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed :
S&F MCBs SP 240 volt, 6 to 32 Amps, C series, 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A)
S&F MCBs SPN 240 volt, 40 to 63 Amps, C series, 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A)
S&F electronic type modular , 120 watt -2 modul fan regulator . Make : Anchor/Surya/Havells odulardular
M&L ceiling rose , single phase /PVC /Polycarboante isolated body.
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less thatn 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers GI earth wire with protected by 15mm dia light grade GI pipe and other end connected to earth testing point or main controlling switch as directed incl funnel with watering pipe 20mm bore light grade GI pipe, wire mess , charcol and common salt, concrete earth pit in PCC (1:3:6) type C1 cast iron frame cover , including necessary excavation, earth work in soft/loose soil and disposal of soil to a distance not exc 50mtr and necessary testing complete all as shown in electrical plate No 3 of MES schedule Part I and testing all as directed.
S&F Higly efficient LED Bullbs of 15 W
S &F for LED light fittings 1X15 watts bulkhead luminaires including LED light driver holderconnectingup with 3 core flexible copper conductor cable ofsuitable size complete as per SSR
S& F lamp holder ,PVC/POLYCARBONATE Type with back plate suitable for batten fittings
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments138.pdf
Tender Documents • 0.62 MB
BOQ_842633.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid