KARWAR
2 conditions · 2 needing a document upload
4.2 Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turn over of V/N or V whichever is less, where: V= Advertised value of the tender and N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit Certificates to this effect which may be an attested Certificate from the concerned department /client or Audited Balance Sheet duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Note for 4.2 : Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India. 4.3 Eligible Tenderer/s 4.3.1 The invitation for bids is open for all Tenderer/s satisfying the eligibility criteria as defined in clause No. 4.1 & 4.2 above and who are not disqualified by following sub clauses 4.3.2 and 4.3.4. 4.3.2 Tenderer, who is under a declaration of ineligibility for corrupt and fraudulent practices, shall not be eligible to bid. 4.3.3 Tenderer/s who are not eligible as per Govt. of India directives/ policies/circulars/guidelines etc. 4.3.4 Tenderer/s whose works/contracts have been rescinded on account of poor performance or any other reasons attributable to the firm in the last 3 financial years immediately preceding the current financial year and the current financial year i.e FY 2022-23, up to the date of opening of tender shall not be eligible.
4.0Eligible Eligibility Criteria: 4.1 Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender Note for Item 4.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of 500 crore and above in last 3 (three) financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered, provided the work experience certificate has been issued by a person authorized by the public listed company to issue such certificates. In case, tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificate for all payments received and copy of final /last bill paid by company in support of above work experience certificate. 4.1.1 Similar Nature of work: " All Electrical works " . 4.1.2 The following will be applicable for evaluating the technical eligibility: 4.1.2.1 The Tenderer shall submit necessary proof in the form of valid documents/completion certificates from the respective principal clients in support of their technical capability. The client's certificate should inter- alia indicate the date of award, scheduled date of completion, actual date of start and completion of similar work indicating successful completion and final value of contract as per Appendix 2 & Appendix 3. 4.1.2.2 Only those works which have been executed for the Govt/ Semi Govt./PSU and Public listed company as mentioned under Note for item no 4.1 above shall be considered. 4.1.2.3 In case of composite works involving combination of different works, even separate similar nature completed works of required value shall be considered while evaluating the eligibility criteria.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Annual Maintenance Contract for lighting arrangements provided for tunnels, stations, platforms, approach roads, circulating area and service buildings, etc. between Asnoti to Thokur stations under Karwar region on Konkan Railway route in the state of Karnataka.
KR-KW-EL-AMC-T-35-2025RT2
KR-KW-EL-AMC-T-35-2025RT2
Open
Works - General
24 Months
Navi Mumbai, Maharashtra
₹0
₹1.9 L
29 Apr 2026
7 Apr 2026
15 Apr 2026
301 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 53,76,070.37 | ||
| — | 22500.00 | — | — | ||
| Cleaning of all type and wattage of lighting fixture provided on KR route and various installations up to 10 meter height. (Once in the six month) | — | — | — | 28,19,250 | |
| — | 2500.00 | — | — | ||
| Repairing for all types of light fittings by replacing defective accessories like LED plate and Driver etc. by removing the complete fitting and refixing the same in position. | — | — | — | 4,46,750 | |
| — | 100.00 | — | — | ||
| Replacement of complete fitting with repaired/new fitting. (This includes repairing of fitting & replacement of any one or all accessories & refixing) | — | — | — | 21,360 | |
| — | 72.00 | — | — | ||
| Weekly Cleaning of Sub-station/TVCR Premises, enclosures for power panels, DG set rooms, (Includes cleaning of Toilets, Wash basins, cleaning of DG, cable trench etc.). | — | — | — | 78,292.8 | |
| — | 750.00 | — | — | ||
| Supply of paints & painting with one quote of Red-oxide and two quotes of aluminium paint of approved brand. (This includes scrapping and brushing with wire brush) of (Once in a year) i) i) Single pole/Street light poles | — | — | — | 4,96,050 | |
| — | 6.00 | — | — | ||
| Supply of paints & painting with one quote of Red-oxide and two quotes of aluminium paint of approved brand. (This includes scrapping and brushing with wire brush) of (Once in a year) ii) Double pole structure | — | — | — | 11,654.7 | |
| — | 12.00 | — | — | ||
| Supply of paints & painting with one quote of Red-oxide and two quotes of aluminium paint of approved brand. (This includes scrapping and brushing with wire brush) of (Once in a year) iii) Four pole structur | — | — | — | 62,195.64 | |
| — | 2.00 | — | — | ||
| Supply of paints & painting with one quote of Red-oxide and two quotes of aluminium paint of approved brand. (This includes scrapping and brushing with wire brush) of (Once in a year) iv) Six Pole structure | — | — | — | 25,913.08 | |
| — | 4.00 | — | — | ||
| Supply of paints & painting with one quote of Red-oxide and two quotes of aluminium paint of approved brand. (This includes scrapping and brushing with wire brush) of (Once in a year) v) Switch yard fencing | — | — | — | 25,913.08 | |
| — | 20.00 | — | — | ||
| Painting of control panel provided for lighting including removal of old panel cleaning of surface & spray painting with 1 coat of red oxide & 2 coats of enamel synthetic paint.(Once in two year ) | — | — | — | 10,597.8 | |
| — | 50.00 | — | — | ||
| Making solderless crimping type joints in feed cables of size upto 95 sqmm, 1.1 KV grade PVC insulated & PVC sheathed, multistranded unarmoured / armoured cables. Straight joints / End termination | — | — | — | 816.5 | |
| — | 200.00 | — | — | ||
| Removing/Re-laying and connecting of 1.1 KV grade PVC insulated, PVC sheathed armoured cable with Aluminium conductor size upto 95 sqmm, upto 4 core, in underground (New/fault rectification) including excavation of cable trench, laying of the cable with warning cover refilling and consolidation. (At any site in KAWR region) | — | — | — | 28,770 | |
| — | 200.00 | — | — | ||
| Removing / Relaying in cable supporting brackets & connecting of 1.1 KV grade 3/4 core size upto 95 sq.mm P V C insulated & PVC sheathed multi stranded unarmoured / armoured cables (At any site in KAWR region) | — | — | — | 3,702 | |
| — | 200.00 | — | — | ||
| Removing/Relaying of earthing conductor of various size for earthing. | — | — | — | 2,042 | |
| — | 10.00 | — | — | ||
| Checking, aligning, deburring etc. of Gang operated switch and DOF as per scope of work | — | — | — | 3,876.4 | |
| — | 26.00 | — | — | ||
| Supply of paint and painting body of oil cooled/ dry type transformer, 100 to 500 KVA rating with one quote of red of aluminium paint of approved oxide and two coats brand (This includes scraping and brushing with wire brush) | — | — | — | 67,378.48 | |
| — | 25.00 | — | — | ||
| Provision of service connection to the KRCL's load center or service building from nearest / existing KRCL's power supply source. (This includes dismantling of existing / failed service wires and stringing of new wires.) | — | — | — | 16,534.75 | |
| — | 50.00 | — | — | ||
| Provision of precast RCC Earth chambers as per IE rules This includes loading, unloading and Transportation to the KRCL's site. | — | — | — | 8,626.5 | |
| — | 20.00 | — | — | ||
| Provision of CI cable route markers/ indicators as per IE rules (LT/HT) in the ground including excavation and concreting complete with labour & all connecting material including shoring and shuttering. Size of the concrete block is about 250 x 250 x 250 mm for each cable marker | — | — | — | 7,753 | |
| — | 20.00 | — | — | ||
| Trimming of tree branches to maintain required clearance from OH lines (LT / HT) as per IE rules. | — | — | — | 10,597.8 | |
| — | 1.00 | — | — | ||
| Provision of guarding to the over head lines (LT / HT) I.e. for road / river crossing, for platform lights or in between two over head power supply lines as per IE rules. ( This includes dismantling of existing / failed guarding and stringing of new guarding) | — | — | — | 1,295.56 | |
| — | 100.00 | — | — | ||
| Supply of paints and painting of poles with one coat of Red oxide and 2 coats of Aluminium paint of approved brand (This includes scrapping and brushing with wirebrush) for platform lights pole including all MS fabricated items provided on such poles (Tubular/ pipe/RCC) but excluding PF light fittings (once in a two year) | — | — | — | 51,830 | |
| — | 100.00 | — | — | ||
| Reconditioning of earthing to improve the earth value by using necessary char-coal salt etc. including watering of earth pits. | — | — | — | 38,770 | |
| — | 5.00 | — | — | ||
| Fixing of stay sets with break insulators making use of GI wires with turn buckle and anchoring arrangement as per KRCL'S STD Drg..including excavation & concreting | — | — | — | 1,938.5 | |
| — | 20.00 | — | — | ||
| Fixing of 1.1 KV LT pin insulator with pin and Nut. | — | — | — | 530.8 | |
| — | 20.00 | — | — | ||
| Fixing of 11 KV HT Disc insulators 90 KN | — | — | — | 1,020.6 | |
| — | 4700.00 | — | — | ||
| Cleaning of ceiling fans provided at station platform, stations and service buildings | — | — | — | 1,91,854 | |
| — | 10.00 | — | — | ||
| Checking of 11KV /LT 1/2/3 Ph, 2/3/4/5/6/8 wires overhead lines & cleaning of insulators as per scope of work | — | — | — | 51,009 | |
| — | 200.00 | — | — | ||
| Repairing of driver of 24W LED fitting with own parts, labour | — | — | — | 89,564 | |
| — | 50.00 | — | — | ||
| Repairing of PCB of LED fitting for all type of wattage. | — | — | — | 45,788 | |
| — | 25.00 | — | — | ||
| Replacement of defective accessories like 50-100 W COB, 50,100,200 W PCB, driver double circuit driver etc by removing the fitting and refixing of fitting in position. This includes lowering and raising of luminary carriage. | — | — | — | 3,880.5 | |
| — | 22.00 | — | — | ||
| Labour charges for maintenance of High Mast Lighting System ( once in a year) by lowring and raising of Luminarie carridge, LED High Mast light Fitting, Maintenance of LED high mast light fitting by replacement of defective LED drivers and LED PCB panels with new LED drivers and PCB panels sealing the fitting with silicon solevant. Cleaning of Luminaries, Checking of Electrical connection of feeder pilar box. High Mast and light fitting. Greasing of gear box of High Mast. Maintenance of feeder pillar by replacing defective timer by new timer and replacement of defective contactor by new contactor and defective push button by new push button also include 1) General check up of hand hole cover & bolt, Tightening and/or replace if required. 2) Mechanical - Gear box for seal leakage transitial yoke & cables for their corrosion, Lift cable for frayed strands, Latch system repaired/ replaced as required. Checking of wire rope and greasing. 3) Cleaning test operation of lowering device and wire rope. 4) Checking of grounding system, checking & cleaning of luminaries. | — | — | — | 1,70,959.58 | |
| — | 100.00 | — | — | ||
| Dismantling/Re-fixing, wiring and connecting of twin, PVC metal clad 3 pin socket outlets with 1 No. SP MCB 5A rating in an ABS housing | — | — | — | 7,189 | |
| — | 20.00 | — | — | ||
| Dismantling / Re-erection of PUSH BUTTONS with one 'ON' and one OFF' Push button on wall & its connections. | — | — | — | 2,872.6 | |
| — | 10.00 | — | — | ||
| Dismantling / Re-erection of Switching/ control panel having timer and contactor on wall & its connections etc. | — | — | — | 7,148.2 | |
| — | 260.00 | — | — | ||
| Cleaning of 1 phase / 3 phase power sockets out lets/mobile charging sockets provided. (This includes checking & tightening of loose connections.) | — | — | — | 32,578 | |
| — | 10.00 | — | — | ||
| Concrete complete with labour and all connecting material including shoring and shutering with 1:2:4 concrete mix. | — | — | — | 45,045.4 | |
| — | 60.00 | — | — | ||
| Cleaning & checking of control panel with all accessories like push buttons, contactors, timers, wiring indication, lamps etc. including repairing / replacing at site any defective parts. (cost of parts to be paid separately) This includes replacement of rubber gaskets for panel door & locking arrangement | — | — | — | 15,896.4 | |
| — | 5.00 | — | — | ||
| Patrolling of over head line in case of line fault including replacement of insulators (HT/ LT) if any, dismantling, re-stringing or stringing of conductor, replacement of any fabricated item associated with OH line, rectification of fault and commissioning of line. | — | — | — | 13,248.7 | |
| — | 50.00 | — | — | ||
| — | — | — | 4,146 | ||
| — | 200.00 | — | — | ||
| — | — | — | 11,938 | ||
| — | 300.00 | — | — | ||
| — | — | — | 68,613 | ||
| — | 500.00 | — | — | ||
| — | — | — | 40,915 | ||
| — | 300.00 | — | — | ||
| — | — | — | 1,62,360 | ||
| — | 120.00 | — | — | ||
| — | — | — | 48,708 | ||
| — | 300.00 | — | — | ||
| — | — | — | 54,120 | ||
| — | 50.00 | — | — | ||
| Hiring, laying, manning and repairing of LED flood light 200W focusing on Indian flag and maintenance (during Aug-15 and Jan-26 for Karwar, Murdeshwar and Udupi stations). | — | — | — | 11,275 | |
| — | 100.00 | — | — | ||
| Hiring of Tri-colour cloth and making Indian flag with all connecting accessories, manning and maintenance (during Aug-15 and Jan-26 for Karwar, Murdeshwar and Udupi stations). | — | — | — | 45,100 | |
| — | — | — | 23,24,051.65 | ||
| — | 5.00 | — | — | ||
| Supply of Timer type BAR-220/ 240 Volts. Timer range 0 to 10 Hrs Bhartiya cutler Hammer, L&T or similar make | — | — | — | 13,515.55 | |
| — | 1.00 | — | — | ||
| Supply of Contactor ML1 | — | — | — | 2,451.64 | |
| — | 1.00 | — | — | ||
| Supply of Contactor ML2 | — | — | — | 3,583.2 | |
| — | 10.00 | — | — | ||
| Supply of TWIN FRP / PVC clad 3 pin socket outlets with 1 No. SP MCB 5A rating in a FRP / ABS housing | — | — | — | 13,201.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tenderdocument-RT-2_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .