| 1 | 1₹42.7 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹46.6 L+₹2.6 L (5.97%)Rejected-AOC | 2 | Rejected-AOC L2 BIDDER | |
| 3 | 3₹52.5 L+₹8.6 L (19.5%)Rejected-AOC 91 2 MITRA PARA ROAD NAIHATI DIST NORTH 24 PARGANAS PIN 743 165 WB | NAIHATI | NORTH 24 PARGANAS | WB | 743165 | 3 | Rejected-AOC L3 BIDDER | |
| 4 | 4₹54.6 L+₹10.6 L (24.2%)Rejected-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | 4 | Rejected-AOC L4 BIDDER | |
| 5 | 5₹56.1 L+₹12.2 L (27.8%)Rejected-AOC | 5 | Rejected-AOC L5 BIDDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
30 Aug 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD
COMPREHENSIVE MAINT OF FLOOR ROOF CEILING COLUMNS JOINERY CHAJJA FAINS FACIAS LEAKAGE SEEPAGE PLASTERING DOOR WINDOW VENTILATORS GRILLS GUARDS BARS PLUMBING STRUCTURAL REPAIRS SMART PERIODICAL SERVICES SEWAGE LINE SEPTIC TANK
2023_MES_612983_1
8296/23-24/GE(N)/KOL/ /E8 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
COSSIPORE
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹94,000
Yes
20 Oct 2023
9 Aug 2023
31 Aug 2023
10 Aug 2023
30 Aug 2023
23 Aug 2023
Amount
Taking down/ dismantling loose/ damaged concrete including plaster of any description and in any position from RCC structures like chajja, fins, roof ceiling,louvers, parapet, column, beam, and of lintel by hammering with wooden mallets carefully chipping off the old concrete surface with necessary scaffolding upto 24mtr height including cutting of rusted reinforcement if so required and disposal of old debris to outside the premises complete all as specified and as directed.
Cleaning the existing surface of concrete and reinforcements as obtained after execution of item No. 01 here in before by wire brush including scrapping & cleaning with emery paper or by air blasting or sand blasting including foreign matrials, loose concrete/ aggregates etc. and washing down with water as required complete all as specified and directed.
Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending lapping etc as required and welding with existing bar complete all as specified and as directed
Material and labour for TMT bars 6 to 8mm bar, cut to length, bent to shape required, including cranking, bending, lapping etc as required and welding with existing bar complete all as specified and as directed.
Material and labour for TMT deformed bar or twisted bars upto 10mm dia as in stirrups cut to lenth bent to shape required including cranking ,bending etc and lapping ,welding as directed to the existing one complete all as specified and as directed.
M&L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm complete all as specified and directed.
Supply and application of Epoxy Zinc rich primer on the steel surface by brush the primer shall have a minimium specific gravity 1.75, minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel 1.5N/mm2 including cleaning and removing loose concrete from steel surface complete all as specified and directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-30 to the effected beam, column etc. The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 30 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength of 5N/mm2 @ 28days and complete all as specified and directed.
Supply, mixing and application of two component structural grade polymer modified reinstatement mortar, where local spalling has taken place or shuttering is not possible . The mortar can be applyied in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength of 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength of 24 N/mm2, minimum tensile strength of 3.5N/mm2, minimium flexural strength of 6.5N/mm2 complete all as specified and directed.
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished concrete surfaces complete all as specified and as directed.
M&L for use and waste of formwork to sides of sides and soffits of beams, lintels, floors etc. for rough finished concrete surfaces complete all as specified and as directed.
M&L for use and waste of formwork to parapet, RCC wardrobe and similar items for rough finished concrete surfaces complete all as specified and as directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works n.exc. 200mm thick etc for rough finished concrete surfaces complete all as specified and as directed
M&L for use and waste of formwork to fins, facia, louvers. parapet, chajja etc for rough finished concrete surfaces complete all as specified and as directed
Material and labour for 5 mm thick plastering in CM (1:3) on concrete surfaces as in sides of column, lintel, beam, chajja, facia, railing, RCC wardrobe etc including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for 20mm thick plaster in cement mortar (1:4) in two layers, i.e 10mm thick in each layer, top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall finished the surface fair and even complete all as specified and as directed. Note :- WPC shall be measured and paid separately.
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
Supply only water proofing liquid admixture for cement mortar complete all as specified and directed.
Material and labour for rendering 5mm thick in cement mortar (1:3) on concrete surfaces in ceiling, finished the surface even and smooth without using extra cement complete all as specified and as directed.
Demolition of reinforced cement concrete of roofs, floors, staircases, landing, chajjas and similar suspended works in ground floors beams (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition of reinforced cement concrete of roofs, floors (other than ground floors) beams, staircases, landing, chajjas and similar suspended works (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Material and labour for RCC 1:1.5:3 type A1 (using 20mm graded stone aggregate) as in fins, fascias, louvres, parapets,and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and as directed. Note : Reinforcement and formwork shall be measured and paid separately.
M&L for reinforced cement concrete M-25 (design mix) as in chajjas and like complete all as specified and directed. Note : Reinforcement and formwork shall be measured and paid separately.
Material and labour for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
All as per item No. 25 above but in ceiling complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified & directed.
M&L for preparation and applying wall care putty 1.5mm thick and applying two coats of oil bound distemper over a coat of alkali resistant primer to wall to new plastered surfaces complete all as specified and as directed.
Material and labour for complete removal of existing treatment of old plastered surfaces of wall including washing, rubbing down and stopping of old treatement and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified & directed.
Material and labour for complete removal of existing treatment of old plastered surfaces of wall including washing, rubbing down and stopping of old treatement and applying two coats of oil bound distemper over a coat alkali resistant primer and finishing the existing surface with 1.5mm thick wall putty etc complete all as specified and as directed.
Material and labour for preparation of old treated plastered surfaces of wall and applying one coat of white wash complete all as specified and as directed.
All as per item No. 31 above but in ceiling complete all as specified and directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed.
Dismantling of old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing and rubbish off the premises complete all as specified and as directed.
Material and labour for Light shade Vitrified tiles 10mm thick (square/rectangular) polished, area of each tiles n.exc. 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 20mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Material and labour for Light shade Vitrified tiles 10mm thick (square/rectangular) polished, area of each tiles n.exc. 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
Material and labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n.exc. 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Material and labour for glazed ceramic colour tiles (300x200) x7mm thick in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n.exc. 15 cm thickness below or above ground level complete all as specified and directed.
Material and labour for 75mm thick PCC type D2 (1:4:8) (using 40mm garded stone aggragate) as in sub base of floors etc complete all as specified and as directed.
Material and labour for (300x300) x25 mm thick PCC designer Pre-polished tiles (Factory make and approved size) as in floors, set & jointed in neat cement slurry and pointed in coloured cement with pigment over and including 20mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Dismantling wall and ceiling board ( fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets etc. complete all as specified and directed.
Supply and fix Anodised aluminium snap grid frame work size of grid 605mmx605mm for false ceiling including GI hangers 6mm dia GI wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as per manufacturers instruction complete all as specified and directed.
Supply and fix of 6mm thick high pressure steam cured non asbestos fibre cement designer ceiling board of size to suit grid mould (605 x 605mm as specified above) and fix in grid mould with necessary fixing arrangement as complete all as specified and directed.
Supply and fix in repair UPVC (SWR) pipe 110 mm bore,single socketed, in any length with rubber ring joints fixed to walls with and including PVC clip complete all as specified and directed.
Supply and fix in repair UPVC(SWR) bend/shoe 110 mm dia complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections, segregating serviceable pipe for reuse complete all as specified and as directed.
All as per item No. 49 above but 20mm dia complete all as specified and directed.
Supply and fix 15mm bore medium grade galvanized steel tubes with all fittings and fixed to wall or in floors etc complete all as specified and as directed.
All as per item No. 51 above but 20mm dia complete all as specified and directed.
Fixing only serviceable 15mm GI pipe obtained from item No. 49 above after cleaning complete all as specified and directed.
Fixing only serviceable 20mm GI pipe obtained from item No. 50 above after cleaning complete all as specified and directed.
Supply and fix in repair bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix in repair angular stop cock of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and as directed
Supply and fix in repair pillar cock of 15mm bore, cast copper alloy with capstan heads fancy type, chromium plated screwed down, high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed
Supply and fix in repair 10 litre capacity PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern including PVC connections 15mm size with PTMT nuts and washer both side of length 450mm complete all as specified and as directed.
Supply and fix health faucet (ABS body) with 8mm dia 1 meter long flexible tube and wall hook for fixing in 15 mm dia pipe complete all as specified and as directed.
Supply and fix chromium plated two ways bib cock with wall flange for fixing in 15 mm dia pipe complete all as specified and as directed.
Supply and fix in repairs vitreous China wash basin white flat back, size 630 x 400 mm including PTMT waste coupling 32mm dia (min wt 45 gm), 15mm bore PTMT pillar tap,chain and plug and porcelain stopper etc. complete all as specified and as directed.
Supply and fix in repair Brass chromium plated Tubular Towel Rail , 20mm dia, D type, 600mm long between flange fixed with chromium plated brass screws complete all as specified and as directed.
Supply and fix in repairs PVC connection 15mm size with PTMT nuts of length 600 complete all as specified and as directed.
S & F in repairs Rotational moulded polyethylene water storage tanks multi-layered (cylinderical vertical with closed top) 1000 Ltr Capacity, hoisted and fixed in position complete all as specified and directed.
All as per item No.64 above but 2000 Ltr capacity complete all as specified and directed.
Supply and fix in repairs 20mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
Supply and fixing in repair Gun-metal, globe or gate valves size 20 mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and fix 3mm thick sheet glass, ordinary quality and glazing each pane fixed to steel frame (fixed with oil putty and clips)/ wooden frame (fixed with 2nd class hard wood beads) including hacking out old broken glass from metal frame/ wooden frame complete all as specified and directed.
Supply and fix 3mm thick frosted glass, ordinary quality and glazing in each pane fixed to steel frame (fixed with oil putty and clips)/ wooden frame (fixed with Iind cl hard wood beads) including hacking out old broken glass from metal frame/ wooden frame complete all as specified and as directed.
Supply and fix in repairs stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples complete all as specified and as directed.
Taking down old unserviceable steel window/ ventilator of any description including guard bar ,peg stay and handle complete all as specified and as directed.
Supply and fix powder coated anodised sliding aluminium window shutters for glazed/ gauged, aluminium section weighing 0.55kg/m including necessary joining cleats, roller rubber neoprene packing/ gasket,etc complete all as specified and directed.
Supply and fix powder coated aluminium frame for doors, windows, ventilators (including 2/3 track) with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Supply and fix 4mm thick sheet glass ordinary quality, glazing with aluminium beads in square/ rectangular exceeding 0.5 Sqm in each pane fixed to aluminium frame complete all as specified and as directed.
Supply and fix rolled mild steel Fe-410-w (grade E-250) quality A framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and as directed.
Supply and fix stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to new steel surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and as directed.
Demolition of cement concrete of any description including any treatment there to and in any position provided as in roof padding, roof curb etc complete all as specified and as directed. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of old debris/retrieved material to outside the premises or as directed by the Engineer-in-Charge.
Material and labour for providing plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately.
Material and labour for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment :- (a) Applying bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified and directed. (b) Applying APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced (4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified and directed.
Repair, maintenance and servicing of packaged type AC unit of capacity 5.5 ton including taking out existing packaged type AC unit carefully by disconnecting existing electrical connection, removing aside, packing and cleaning with blower & soap solution making dust free to the system, tightening all nuts, bolts, screws, oiling blower motor, checking of all electrical connection, checking for leakage etc and re-fixing the AC in existing place properly including all spare parts complete all as specified and directed.
Material and labour for taking down window type Air Conditioner of upto 2 TR,cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, Servicing. greasing,replacing of spares required, and refixing at same location with proper rectification of leakage and commissioning , etc complete all as specified and directed. Existing makes of AC:- LG / Samsung / Voltas / Videocon/As per existing. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
Dismantling covers of out-door and in-door units of split type Air Conditioner of capacity upto 2.0TR, cleaning completely the condenser coil and cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water, Servicing. greasing,replacing of spares required, re-fixing the covers with proper rectification, in same position complete all as specified and directed. Existing makes:- LG / Samsung / Voltas / Videocon/As per existing Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
Material and labour for taking down water cooler of upto 150 ltr,cleaning by water , thoroughly, cleaning by caustic and re-washing with plain water, Servicing. greasing,replacing of spares required, and refixing at same location with proper rectification of leakage and commissioning , etc complete all as specified and directed. Existing makes of AC:- LG / Samsung / Voltas / Videocon/As per existing. Notes:- (i) The spares listed herein after shall be measured and paid as supply only. The spares incorporated shall be of existing make / suitable for the make of AC (ii) Filling of gas shall be measured and paid seperately, under supply only. (iii) Cost of any other spares / minor spares, not specified here in after, and the spares like nut bolts washers etc shall be deemed to be included in the unit rate quoted.
M&L, in repair, for Jointing capillary tubes filter strainer by brazing, cleaning / flushing whole the system, checking any leakage and make good including testing 350 PSI complete for Window type AC of capacity upto 2.0 TR complete all as specified and directed.
All as per item No. 85 above but, Split type AC of capacity of capacity upto 2.0 TR complete all as specified and directed.
All as per item No. 85 above but, Water cooler of capacity upto 150 ltrs complete all as specified and directed.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using supper enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Window type AC of capacity upto 2 TR complete all as specified and directed. Notes:- (i) The unit rate quoted shall be deemed to including for rewinding also.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using supper enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Split type AC of capacity upto 2.0 TR complete all as specified and directed. Notes:- (i) The unit rate quoted shall be deemed to including for rewinding also.
Dismantling of blower fan motor cutting burnt coils and taking out from the stator, cleaning the stator using petrol, rewinding using supper enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for Water Coolers of capacity upto150 litres complete all as specified and directed. Notes:-(i) The unit rate quoted shall be deemed to including for rewinding. .
Repair body and base of water cooler including providing plain MS Sheet of existing gauge / thickness and angle iron of existing thickness and size including necessary welding / brazing repair of leakage in water tank of water cooler, by arc welding after necessary leak testing,, including preparing the steel and iron surface and spray painting with synthetic enamel paint, glossy finish / shop finish, as directed by the Engineer- In- Charge,etc complete, of capacity upto150 litre complete all as specified and directed.
Supply and fixing, Running capacitor 10-40 mfd for 1.5/1.0/2.0 TR capacity window type/split type Air Conditioner complete all as specified and directed.
All as per item No. 92 above but, Running Capacitor 4 mfd complete all as specified and directed.
All as per item No. 92 above but, Capillary Tube (copper) as per existing size complete all as specified and directed.
All as per item No. 92 above but, Filter strainer complete all as specified and directed.
All as per item No. 92 above but, Starting relay complete all as specified and directed.
All as per item No. 92 above but, Air filter made of plastic frame and nylon net complete all as specified and directed.
All as per item No. 92 above but,Thermostat switch make complete all as specified and directed.
All as per item No. 92 above but, Contactor relay for split type AC complete all as specified and directed.
Supply and fix, starting capacitor 45/ 50 Mfd + 6 MFD upto 2 ton split type AC complete all as specified and directed. (Make : SARADA / UNIVERSAL / Usha / Copco / HPL / L&T / Existing make)
Supply and fix Blower motor for window type AC1.5 Ton capacity complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
All as per item No. 102 above but, Blower motor for window type AC 2 Ton capacity complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
All as per item No. 102 above but Blower motor for Split type AC upto 2 Ton capacity complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc).
Supply and fix in repair, Front grill for, Window type AC of capacity 1.5 TR complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, Front grill for, Window type AC of capacity 2 TR complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, PCB Board for split type, of capacity 1.0 TR AC complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, PCB Board for split type, of capacity 1.5 TR AC complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, PCB Board for split type, of capacity 2.0 TR AC complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply only Rubber bushing for blower motor of suitable and existing capacity AC complete all as specified and directed.
Supply and fix in repair, Swing motor for split type AC of capacity upto 2.0 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair, Swing motor for window type AC of capacity 2.0 TR complete all as specified and directed. Make:-(as per existing make).
Supply and fix in repair, Display assembly for spilit type AC of capacity 2.0 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair, Display assembly for WINDOW type AC of capacity 2TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair, Sensor for Indoor unit of Split type AC, of capacity Upto 2.0 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair, Service line charging valve 5/8'' (Brass) complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair, Liquid line valve 1/4'' (Brass) complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair, PCB Board for window type AC upto 2 .0 TR complete all as specified and directed. Make:- (as per existing make of Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fix in repair, condenser coil of copper for split type AC, of capacity 1.5 TR complete all as specified and directed. Make:- (as per existing make)
Supply and fix in repair, condenser coil of copper for split type AC, of capacity 2.0 TR complete all as specified and directed. Make:-(as per existing make)
Supply and fix in repair, condenser fan for AC of 1.0 TR/1.5 TR / 2.0 TR complete all as specified and directed. Make:- (as per existing make)
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC casing-caping surface typecomplete all as specified and directed. Note:- 3 runs of cable, 1 run of casing-caping shall be measured and paid as one unit i.e Rm.
Supply and fixing in repair rotary sealed unit Compressor for window/split AC of 1.5 Ton capacity
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6 sqmm as earth continuity conductor drawn through PVC casing-caping surface type complete all as specified and directed. Note:- 3 runs of cable, 1 run of casing-caping shall be measured and paid as one unit i.e Rm. Make of cable:- MESCAB / POLYCAB / HAVELLS / KEI / FINOLEX. Make for casing Caping:- Plaza / Presto Plast / Precision/ M/S AGK Industries
Supply and fixing in repair rotary sealed unit Compressor for window/split AC of 2 Ton capacity complete all as specified and directed.
Supply and fixing in repair Water cooler compressor capacity above 40 and upto 150ltrs complete all as specified and directed.
Supply and laying in repair refrigerant line copper tubing of size 3/8 " with clamping on wall surface or concealed with both the ends connection complete all as specified and directed.
All as per item Ser No 127 ( here - in - before) but of size 1/4 " complete all as specified and directed.
All as per item Ser No 127 ( here - in - before) but of size 1/2 " complete all as specified and directed.
S & F in repair foam insulation/ keniform for copper tubing of size 1/2" and 1/4'' dia complete all as specified and directed.
S&F in repair flexible drain pipe for split type AC complete all as specified and directed.
Supply and fixing in replacement, Push type tap copper alloy chromium plated 15 mm bore suitable for upto150 ltrs capacity water cooler complete all as specified and directed.
All as per item No. 132 but, Rubber lining for top cover gasket of capacity upto 150 litre Water Cooler complete all as specified and directed.
Supply only, Starting relay suitable for 5/8 HP motor of water cooler complete all as specified and directed.
Supply only Starting capacitor 80/100 mfd for water cooler complete all as specified and directed.
Supply only Thermostat complete all as specified and directed.
Supply and fix in repair, Float valve Brass with fly nut, of dia / bore 15 mm , etc complete screwed as per existing complete all as specified and directed.
Supply only, Over load protector complete all as specified and directed.
Supply only Capilary tube as per existing size (Copper) complete all as specified and directed.
Supply only Blower motor as per existing complete all as specified and directed.
Supply only CP Basin tray complete all as specified and directed.
Supply only Running capacitor 15 mfd complete all as specified and directed.
Supply and charging refrigeration gas R-22 for Split/window AC confirm with N2 pressure testing and flushing the system with liquid nytrozen, dehydration and evacuation the system complete all as specified and directed. Make: Mafron or equivalent .
Dismantling, shifting and refixing of split type AC of capacity 1.5 to 2.0 TR including proper arrangement to keep outer unit (Angle iron with nut bolt) safely without gas leakage, in the unit complete all as specified and directed.
S & F in repair for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt complete all as specified and directed. Make: Havells/Legrand/L&T / Indoasian / HPL / Standard).
Material and labour for cutting holes in brick wall for fixing of window type Air Conditioner including removal of rubbish from the site of work within 50 m distance including necessary, second class hard wood, wooden frame work not less than 2" by 2" thick and size as per AC model including plastering 10 mm thick in CM 1:6, side walls in cement mortar 1:6 and white wash / distemper complete, to match the existing surface, including preparation of new wooden surfaces and applying 2 coats of synthetic enamel paint, first quality, over a coat of pink primer, etc complete all as directed. Make of paint:- Asian / Berger / Jenson & Nicholson / Berger.
Taking down out door unit of 1.5TR/2.0 TR capacity removing unserviceable AC stand/angle iron bracket fixing new AC stand/angle iron bracket in repair (including two coats of sunthetic enamel paint over a red oxide primer) fixing to the wall by foundation bolts refixing the out door unit connection the suction and discharge line complete testing and running all as directed.
Dismantling and taking out voltage stabllizer transformer unit, auto transformer varier, electric circult board, all cable connections, including repairing/replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter, PVC connector, indicator lamp, cutout, MCB complete parts along with testing commissioning and trasportation charges from site to workshop all as directed of capacity Upto 2 KVA complete all as specified and directed.
All as per item No. 148 but, 03 KVA to 5 KVA capacity complete all as specified and directed.
Supply and fixing indoor unit of split ac of capacity 1.5 TR with all accessories including taking down of old unserviceable indoor unit complete all as specified and directed.
Supply and fixing outdoor unit of split ac of capacity 1.5 TR with all accessories including taking down of old unserviceable indoor unit complete all as specified and directed.
Supply and fix modular plate with starter plug and socket AC single phase, 230 Volts, 25 Amps capacity, including metallic mounting box including taking down the old unserviceable modular plate with starter plug and socket complete all as specified and as directed. Make :Crabtree /havells/C&S/Standard or equivalent)
Supply & fixing in repair 15 Amp plug top complete with all connection, complete all as specified and as directed. MAKE:- Anchor / Cona / Bajaj / Crabtree / Havells / HPL / C&S / Standard
Supply and fixing indoor unit of split AC of capacity 2 TR with all accessories including taking down of old unserviceable indoor unit complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
Supply and fixing outdoor unit of split ac of capacity 2 TR with all accessories including taking down of old unserviceable outdoor unit complete all as specified and directed. (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
M&L for spray painting with DUCO paint, first quality, (ISI grade) white using spray machine including cleaning, washing, preparation of old painted surfaces for Window type AC's upto 2.00TR complete all as specified and directed. Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
M&L for spray painting with DUCO paint, first quality, (ISI grade) white using spray machine including cleaning, washing, preparation of old painted surfaces for Split type AC's upto 2.00TR capacity complete all as specified and directed. Make:- Asian / Berger / Jenson & Nicholson / Shalimar.
M&L for spray painting with DUCO paint, first quality, (ISI grade) white using spray machine including cleaning, washing, preparation of old painted surfaces complete all as specified and directed.
Supply and fix automatic voltage stablizer single phase 220 volt 50 hz of capacity 5 KVA complete all as specified and directed.
Supply and charging refrigeration gas R-134 for refrigrator/water cooler/deep freezer confirm with N2 pressure testing and flushing the system with liquid nytrozen, dehydration and evacuation the system complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keep aside serviceable materials for reuse including making good of the disturbed surfaces, complete all as specified and as directed.
Taking down only old u/s items such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully including making good of the disturbed surfaces, complete all as specified and as directed.
Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC casing-N- caping (medium duty) double lock type,size of casing caping as required at site but not less than 20mm with fittings and accessories pressed steel sunken terminal box in concealed made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for one light point controled by one, one way 5 Amp switch complete all as specified and as directed.
All as per Item No. 163 above but for one fan point controlled by one, one way 5 Amp switch complete all as specified and as directed.
All as per Item No. 163 above but for one 5 pin socket outlet 05 Amp on independent board complete all as specified and as directed.
All as per Item No. 163 above but for one 5 pin socket outlet 05 Amp on same board complete all as specified and as directed.
All as per Item No. 163 above but for one bell/buzzer point controlled by one push button same board with other switch or independent complete all as specified and as directed.
All as per Item No. 163 above but for one light point controlled by two 2 way switch complete all as specified and as directed.
All as per item No 163 above but for one 15 Amps socket outlet but using 2.5 sq mm,copper conductor with 1.5 sq mm,PVC insulated single core cable for earth continuity conductor complete all as specified and as directed.
M & L for concealed point wiring complete with 1.5 sq mm FRLS, PVC insulated multi standard copper conductor single core cable 1100 volts grade,drawn into non metalic PVC rigid conduit medium grade of size not less than 20mm bore and conduit accessories fixed on wall roof etc, and including provn of PVC insulated 1.5 sq mm copper conductor cable for each continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6 mm thick MS sheet concealed in wall and laminated sheet cover of 3 mm thick on top for housing the switches socket,outlet etc., for one light point controled by one, one way 5 Amp switch complete all as specified and as directed. Note :- (i) PVC conduit , making good disturbed wall surfaces including finishing with cement mortar 1:4 matching with existing shade of the painted surface are deemed to be included in the quoted rate. (ii) Cutting chases shall be measured and paid seperately.
All as per item No 170 above but for one fan point controlled by one, one way 5 Amp switch complete all as specified and as directed.
All as per item No 170 above but for one 5 pin socket outlet 05 Amp on independent board complete all as specified and as directed.
All as per item No 170 above but for one 5 pin socket outlet 05 Amp on same board complete all as specified and as directed.
All as per item No 170 above but for one bell/buzzer point controlled by one push button same board with other switch or independent complete all as specified and as directed.
All as per item No 170 above but for one light point controlled by two 2 way switch complete all as specified and as directed.
All as per item No 170 above but for one 15 Amps socket outlet but using 2.5 sq mm,copper conductor with 1.5 sq mm,PVC insulated single core cable for earth continuity conductor complete all as specified and as directed.
M&L cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cils, sunshades sheleves, lintels, etc and cutting chases for concealed water tubing or concealed conduict wiring etc and making good cutting not exc 10 cm grith complete all as specified and as directed.
Supply and fix switch piano flush button 6 Amp single pole, one way complete all as specified and as directed .
Supply and fix socket out let 5 Pin, 6 Amps flush type complete all as specified and as directed.
Supply and fix Switch socket combination 5 Pin, 6 Amp flush type complete all as specified and as directed.
Supply and fix switch socket combination 5 Pin 6/16 Amp flush type with complete all as specified and as directed.
Supply and fixing switch flush type, 6 Amps, single pole, two way complete all as specified and directed
Supply and fix lamp holder insulated body with back plate for angle/batten fittings complete all as specified and as directed.
Supply and fix ceiling rose surface bakelite, 65 x 50mm, three terminals complete all as specified and as directed.
Supply and fix bell push, flush type 6 Amps complete all as specified and as directed.
Supply and fix electronic fan regulator stepped type flush type AC 240 volt complete all as specified and as directed..
Supply and fix in replacement call bell Ding Dong, AC, 230V single pole complete all as specified and as directed.
Supply and fix lamp holder PVC polycarbonate type with cord grip cap sutiable for pendant fittings complete all as specified and as directed.
Supply & fix Modular switch, one way, 6 Amp, 1 module complete all as specified and as directed.
Supply & fix Modular switch, one way, 16 Amp, 1 module complete all as specified and as directed.
Supply & fix Modular switch 2 way, 6A, 1 Module complete all as specified and as directed.
Supply & fix Modular Bell push 6A,1 Module complete all as specified and as directed.
Supply & fix Modular socket, 6A-2/3 pin combined 2 Module complete all as specified and as directed.
Supply & fix Modular socket, 6A/16A-2/3 pin combined 2 Module complete all as specified and as directed.
Supply & fix Modular fan steep regulator, 120 watt, 2 module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame- 1 Module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame- 2 Module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame- 3 Module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame- 4 Module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame- 6 Module complete all as specified and as directed.
Supply and fix Modular white cover plate with frame- 8 Module complete all as specified and as directed.
Material and labour for sub-main wiring (Concealed type) with two run of PVC insulated, unsheathed, FRLS single core, multistranded copper conductors of size 4.0 Sq mm and one run of 4.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site and taking down old sub main wiring with conduit complete all as specified and as directed. Note:- (i)Three run of 4.0sqmm copper conductor ( for Phase,Neutral and Earth)+One run PVC conduit shall measured as one unit). (ii) Cutting chases shall be measured and paid seperately.
Material and labour for sub-main wiring (Concealed type) with two run of PVC insulated,unsheathed,FRLS single core,multistranded copper conductors of size 6.0 Sq mm and one run of 6.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site and taking down old sub main wiring with conduit complete all as specified and as directed. Note:- (i):Three run of 6.0sqmm copper conductor ( for Phase,Neutral and Earth)+One run PVC conduit shall measured as one unit). (ii) Cutting chases shall be measured and paid seperately.
Material and labour for sub-main wiring (Surface type) with two run of PVC insulated,unsheathed,FRLS single core,multistranded copper conductors of size 10.0 Sqmm and one run of 10.0 Sqmm copper conductor as continuity earth wire,drawn through and including PVC Casing Caping (medium grade) of adequate size with fittings and accessories as required at site all and taking down old sub main wiring with conduit complete all as specified and as directed. Note:- (i) :Three run of 10.0sqmm copper conductor ( for Phase,Neutral and Earth)+One run PVC Casing Caping shall measured as one unit). (ii)Cost of cutting of wall, if any, for housing of GI box and also making good the disturbed surfaces are deemed to be included in unit rate.
Supply and fix in repair powder coated sheet metal enclosure (in concealed) single pole & neutral for DBs (Double door)4 way, 240 V with 200 amps rated busbar DIN channel, neutral link & earth link superline complete all as specified and as directed. Note: (Chase cutting & make good disturb surface is included in unit rate)
All as per item No 205 here in above but for 8 way SPN DB complete all as specified and as directed.
All as per item No 205 here in above but for 12 way SPN DB complete all as specified and as directed.
Supply and fix in repair vertical TPN DB with MCCB incomer of 4 way in double door suitable for four pole MCCB (63A/100 A)as incomer including MCCB+12 modules incoming and outgoing make good of damaged surface/wall including re-connection with existing earth wire to DB complete all as specified and as directed. Note:- MCCB shall be measured and paid seperatly.
Supply and fix in repair MCCB triple pole & neutral 40-100 amps,,16 KA, with all incoming / outgoing connections suitable for fix 4 way vertical type TPN DB in double door twith proper size of aluminium lugs complete all as specified and directed.
Supply and fix in repair MCB single pole & neutral / Double Pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified and directed
Supply and fix in repair MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified and directed.
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) with Funnel for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 150mm C/C both way and two Nos lifting handle made of 8mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete and as specified in electrical plate No 3 of SSR Pt I including taking down old earthing complete all as specified and directed.
Supply and fix in repair GI wire 4.0 mm as earth continuity conductor all as specified and as directed.
Supply and fix in replacement GI pipe 15 mm bore (dia), light-grade for protection of earth electrode acomplete all as specified and as directed. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd.
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) with Funnel for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 150mm C/C both way and two Nos lifting handle made of 8mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete and as specified in electrical plate No 3 of SSR Pt I including taking down old earthing complete all as specified and directed
Supplying & fixing LED tube light fitting, 1 x 18 watt bipin holders, connector block etc. complete with aand connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible twisted twin core cable ,and fixing the light fitting to walls / roof complete all as specified & directed.
supply and fix LED light fitting mirror type high output diffuser 2 ft ,10 watt, 220 volt AC decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of sutiable size complete all as specified and directed.
Supply and fix round shape 6 watt, 220 volt , AC recessed type with high efficiency PMMA diffuser soft glare free light complete with diffuser, holder, LED lamp sutiable for roof ceiling including connecting up with three core flexible copper conductor cable of sutiable size complete all as specified and directed.
Supply and fix round shape 12 watt, 220 volt , AC recessed type with high efficiency PMMA diffuser soft glare free light complete with diffuser, holder, LED lamp sutiable for roof ceiling including connecting up with three core flexible copper conductor cable of sutiable size complete all as specified and directed.
Supply and fix LED luminaire, 600 mm x 600 mm, 40 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fix in repair LED light fitting, 1x10/1x9w bulk head luminaries, with LED lamp, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix LED lamp (B22 Base type) of 1x7 W after taking down the old unserviceable CFL/GLS lamp complete all as specified and as directed.
Supply and fixing in repair flame Proof 2x16w/ 20w LED tube light fixture WIith tube recommended for Gas / Vapor of IIA & IIB and Zone 1 and IP65 Protection complete all as specified and as directed.
Supply and fixing in repair LED light fitting 25/35 watt energy saving versatile pressure die-cast aluminium building security luminaire with suitable GI bracket complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified and as directed.
Supply and fixing in repair LED light fitting 45 watt energy saving versatile pressure die-cast aluminium building security luminaire with suitable GI bracket complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified and as directed.
All as per item no 225 here above but for 60 Watt complete all as specified and as directed.
Supply and fix LED post top lantern with post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection including 20 Watt LED lamp with all accessories and fixing in existing post complete all as specified and directed.
Repair to fan: Taking down carefully Ceiling Fans of any make, model and capacity from their existing places for replacement of bush, bearing, Capacitor, servicing i. e. lubricating / Greasing and for rewinding/ painting by dismantling the same and keep the blades, canopy, splitpin and other parts and components in safe custody and hanging / fitting on it's previous position after repair/rewinding/painting/replacement of spares etc complete all as specified and directed. Note:- i) The unit rate quoted is deemed to include for the labour element involved in replacing the spares as mentioned herein below. (ii) The spares replaced shall be measured and paid as supply only items herein below. (iii) The spares shall suit the exisiting makes of fans or as per existing make of spares, as approved by the GE. (iv) Rewinding and painting shall be measured and paid separately. Existing makes :- Bajaj, Khaitan, Usha, Himadri
All as per item No. 228 above but Exhaust Fans complete all as specified and directed.
All as per item No. 228 above but Air Circulators wall mounted Fan complete all as specified and directed.
All as per item No. 228 above but floor mounted pedestal fan complete all as specified and directed.
Supply only GM Bush for ceiling fan 1200/1400 mm sweep/ Exhaust Fan 230/300/350/450 mm sweep/or any type fan complete all as specified and directed.
Supply only Ball bearing (cat No. 6201) for ceiling Fan/Exhaust Fan / or any type fan complete all as specified and directed.
All as per item No. 233 here-in-before but cat No. 6202 complete all as specified and directed.
All as per item No. 233 here-in-before but cat No. 6203 complete all as specified and directed.
Supply only capacitor 2.5 mfd, 220 volts complete all as specified and directed. Make:Tipcon / Universal / Sarda / Usha. / C&S).
All as per item No. 236 here-in-before but 3.0/4.0 mfd complete all as specified and directed.
Supply and fix in replacement of louver shutter for 300 mm sweep exhaust fan, of existing make, made of MS sheet folded type complete all as specified and directed.
All as per item No 238 here-in-before but for 450 mm sweep exhaust fan complete all as specified and directed.
Material and labour for painting by spraying with synthetic enamel paint to Ceiling Fans / Exhaust Fans/ Air Circulators wall mounted Fans/Floor mounted pedestal Fans including Blades/Down rods/ Canopy/Stand, Casing/ Cage and all accessories after preparation of surfce including thoroughly rubbing /cleaning old rusted spot complete all as specified and as directed. Make of paint:- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for Rewinding of ceiling fans armature of 1200 mm /1400 mm sweep of any make & Model with replacing the burnt out winding by new super enameled high grade copper wire of existing gauge and number of turns and all insulating materials including heat vernishing and testing complete all as specified and directed.
All as per item No. 241 here-in-before but for exhaust fan 230mm/ 300mm sweep, single phase, 230 volts complete all as specified and directed.
All as per item No. 241 here-in-before but for exhaust fan 450 mm sweep, three phase, 230 volts complete all as specified and directed.
Supply and fix in replacement fan blades for exhaust fan of 300 mm sweep as per existing make and type complete all as specified and directed.
All as per item No. 244 here-in-before but for exhaust fan of 450 mm sweep complete all as specified and directed.
Material and labour for lathe work for worn out spindle of ceilling fan /Exhaust Fan/Air Circulators/Wall mounting Fan of any sweep , make & Model with replacing the worn out spindle by new one of existing size and materials including testing for free motion of fans complete all as specified and directed.
Material and labour in replacement of incoming twin core copper flexible wire ( not more than 45cm) of size 14/0.0076 from ceiling rose to ceiling fan / exhaust fans complete all as specified and directed.
Supply and fix in replacement 3 pin plug top 6 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and directed.
Supply and fix in replacement 5 pin plug top 16 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and directed.
Supply and fix in repair 2.5 mfd fan capacitor, 220V complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide or n exc 10 sq m on plan and n exc 1.5 m in depth for foundation etc and getting out in soft / loose soil for taking out pipe line complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and directed.
Removing excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting hard standing / road for laying of pipe, not exc 30 cms wide and not exc 30 cms deep, and getting out in soft/ loose soil etc. complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded aggregate) not exc 30 cms wide and not exc 30 cms for filling and making good to disturbed surfaces of road/ hardstanding etc. complete all as specified and directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 20 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as specified and directed.
All as per item No 256 here in before but for 25 mm bore of pipe complete all as specified and directed.
All as per item No 256 here in before but for 40 mm bore of pipe complete all as specified and directed.
All as per item No 256 here in before but for 50 mm bore of pipe complete all as specified and directed.
Relaying of old serviceable GI pipe 20mm bore obtained from serial Item No 256 here in before with spigot and socket ends in new or old position in any length, laid in trenches after cleaning of inner surface and applying with two coats of black bituminous paint (sutiable for drinking water purpose) including testing complete all as specified and directed.
All as per item no 260 here in before but for 25 mm bore obtained from serial item no 257 here in before complete all as specified and directed.
All as per item no 260 here in before but for 40 mm bore obtained from serial item no 258 here in before complete all as specified and directed.
All as per item no 260 here in before but for 50 mm bore obtained from serial item no 259 here in before complete all as specified and directed.
Supply and fixing of 20 mm bore GI tubing, medium grade with all new fittings as required complete fixed to walls and ceilings or laid in floors/ trenches including testing complete all as specified and directed.
All as per item No 264 here in before but for 25 mm bore of pipe complete all as specified and directed.
All as per item No 264 here in before but for 40 mm bore of pipe complete all as specified and directed.
All as per item No 264 here in before but for 50 mm bore of pipe complete all as specified and directed.
M&L for Minor leakage rectification work of water supply line for GI pipe of size ranging from 15 to 25mm complete within 4-6Hrs. of raised complaint complete all as specified and directed.
All as per item No. 268 above but for 40/ 50mm bore GI pipe complete all as specified and directed.
Supply and fix 20mm bore gun-metal, gate valves, with iron wheel head, screwed both ends for iron pipe and fixed after taking down old unserviceable one complete all as specified & directed. Make : Audco/Laxmi/ Uphadhyay.
All as per item No. 270 above but 25 mm bore complete all as specified and directed.
All as per item No. 270 above but 40 mm bore complete all as specified and directed.
All as per item No.270 above but 50 mm bore complete all as specified and directed.
CHOWDHURY SMALL INDUSTRIES
SENCO
MOTHER LUMIER INDUSTRIES
M/S SHEKHAR TRADING CORPORATION
RBS Builders
M/s Anil Kumar Dutta
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .